{"product_id":"majestic-echelon-ii-60-fireplace-with-intellifire-echel60in-c","title":"Majestic Echelon II 60\" Linear Gas Fireplace ECHEL60IN-C","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Majestic Echelon II 60\" (ECHEL60IN-C) is a contemporary linear direct vent gas fireplace with a long, active ribbon of flame dancing over an LED-lit bed of glass. It is the single-sided member of the Echelon II series, sized for feature walls, media walls and modern great rooms.\u003c\/p\u003e\u003cp\u003eThe look is clean and frameless. You finish it with Clean Face Trim in Black, Gun Metal, New Bronze or Stainless Steel, or a Black Picture Frame Front, then choose the fire bed: the standard bronze glass, or Diamond, Onyx or Sapphire glass, Driftwood logs, a natural stone kit and reflective black glass liner panels. LED ember-bed lighting makes the glass sparkle with or without a flame, so it works as accent lighting on summer evenings too.\u003c\/p\u003e\u003cp\u003eHeat output runs from 28,000 to 50,000 BTU\/h on natural gas (20,000–37,500 BTU\/h on propane by conversion kit), and Majestic rates it for up to 2,150 sq ft. It is certified as a direct vent heater, so it can serve as real zone heat. Optional Heat-Zone (send up to 50% of the heat to another room), Heat-Out (vent up to 40% outdoors) and Passive Heat kits manage wall temperatures so a TV can go above without a mantel.\u003c\/p\u003e\u003cp\u003eIntelliFire Touch intermittent pilot ignition and the included RC400 touchscreen remote handle on\/off, flame height, lights, timer, thermostat mode (heater models), child lock and cold-climate pilot mode, with battery backup keeping the fire on during a power outage. Add the IntelliFire Wi-Fi module for app control with Amazon Alexa and Google Assistant.\u003c\/p\u003e\u003cp\u003eIt vents through Hearth \u0026amp; Home DVP direct vent pipe (top vent, horizontal or vertical, up to 63 ft total run with up to three 90° elbows), and an optional power vent lets the vent run up, down or sideways where a normal route won't work. It is approved for bedrooms and for OEM installation in manufactured homes. Compared with the Marquis II, Echelon II trades the traditional log fire for a modern linear flame and glass media at a lower price point.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear direct vent design\u003c\/strong\u003e: Single-sided linear fireplace with a 59-1\/2 x 12-1\/2 in. viewing area; sealed combustion draws outside air and vents all exhaust outdoors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED ember bed glow\u003c\/strong\u003e: LED lights under the glass media add sparkle and ambient light, with or without the flame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire bed choices\u003c\/strong\u003e: Standard bronze glass media included; optional Diamond, Onyx or Sapphire glass, Driftwood log set, natural stone kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReflective black glass liner\u003c\/strong\u003e: Optional BGK reflective ceramic glass panels multiply the flame and LED reflections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDecorative fronts\u003c\/strong\u003e: Clean Face Trim in Black, Gun Metal, New Bronze or Stainless Steel, or a Black Picture Frame Front (front required, sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelliFire Touch ignition\u003c\/strong\u003e: Intermittent pilot ignition (IPI): the pilot lights only when the fire is called for, with a selectable continuous pilot for cold climates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRC400 touchscreen remote included\u003c\/strong\u003e: On\/off, flame height, lights, timer, child lock and cold-climate mode, plus thermostat mode; factory paired.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery backup\u003c\/strong\u003e: Four AA batteries in the factory battery tray keep the fire running during a power outage (lights and fans need AC power).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart home ready\u003c\/strong\u003e: Optional IntelliFire Wi-Fi module (IFT-WFM) adds app control and voice control with Amazon Alexa and Google Assistant; optional wireless wall switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat management options\u003c\/strong\u003e: Heat-Zone, Heat-Out and Passive Heat (front, top or side discharge, ducted or non-ducted) kits move heat away from the wall above.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent capable\u003c\/strong\u003e: Optional power venting allows vent runs up, down, over or under to reach more locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5 mm ceramic glass with barrier\u003c\/strong\u003e: Ceramic glass front; the required decorative barrier front reduces the risk of burns from hot glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNatural gas, propane convertible\u003c\/strong\u003e: Ships for natural gas; field convertible to propane with the model's LPK conversion kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: UL listed as a direct vent heater to CSA\/ANSI Z21.88-2019 \/ CSA 2.33-2019 (supplemental heat, not a primary heat source); approved for bedrooms and for OEM installation in manufactured homes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimited lifetime warranty\u003c\/strong\u003e: HHT limited lifetime warranty on the firebox and heat exchanger (see Warranty).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eECHEL60IN-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eMajestic Echelon II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eSingle-sided linear direct vent gas fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e70\" W x 47-3\/4\" H x 17-1\/8\" D (manual Fig. 3.1–3.3, pp.11–15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003e72-1\/4\" W x 48\" H x 18-1\/4\" D rough opening; adjust for interior sheathing (Fig. 3.8–3.9, pp.16–18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e59-1\/2\" W x 12-1\/2\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eSides 1\"; back 1\"; front 48\"; combustible floor and flooring 0\"; combustible mantel no lower than 24\" above the top edge of the opening (Fig. 3.8, p.18; Fig. 10.13, p.72)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas\u003c\/th\u003e\n\u003ctd\u003e28,000–50,000 BTU\/h (0–2,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane\u003c\/th\u003e\n\u003ctd\u003e20,000–37,500 BTU\/h with LPK-ECHEL60 conversion kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating capacity (Majestic)\u003c\/th\u003e\n\u003ctd\u003eUp to 2,150 sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eIntelliFire Touch intermittent pilot (IPI) with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRemote\u003c\/th\u003e\n\u003ctd\u003eIntelliFire Touch RC400, included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003e5 mm ceramic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMedia\u003c\/th\u003e\n\u003ctd\u003eGlass media, maximum 6 bags, one layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eHearth \u0026amp; Home DVP direct vent (top vent; horizontal or vertical); optional power vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003eUnswitched 110–120 VAC, 14-2 AWG with ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eUL listed as a direct vent heater to CSA\/ANSI Z21.88-2019 \/ CSA 2.33-2019 (supplemental heat, not a primary heat source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFinished opening with Clean Face Trim: 63-1\/8 in. wide (p.66).\u003c\/li\u003e\n\u003cli\u003eMinimum vertical vent rise before the first elbow: 18 in. (p.31).\u003c\/li\u003e\n\u003cli\u003eWall penetration framing height for a horizontal vent: 64 in. from the base of the unit (p.41); ceiling firestop opening 10 x 10 in. (p.42).\u003c\/li\u003e\n\u003cli\u003eVent clearances to combustibles on horizontal runs: 3 in. on top, 1 in. on the bottom and sides (p.40).\u003c\/li\u003e\n\u003cli\u003eExterior chase: minimum 70 in. tall (Fig. 3.16, p.26).\u003c\/li\u003e\n\u003cli\u003eWith the Passive Heat side-discharge kit: 18 in. minimum clearance to combustibles beside the discharge (Fig. 3.12).\u003c\/li\u003e\n\u003cli\u003eVinyl\/floating floors: a 12 x 12 in. minimum hearth is recommended; without a hearth keep 30 in. clear in front or raise the unit 15 in. (p.27).\u003c\/li\u003e\n\u003cli\u003eMantel heights and projections: follow the combustible mantel charts (Fig. 10.12–10.14, pp.71–72); framing closer than the minimums must be fully non-combustible.\u003c\/li\u003e\n\u003cli\u003eTV above the fireplace: see the Good Faith Guidelines (Fig. 2.4, p.9); Passive Heat needs 12 in. minimum to the TV (p.73).\u003c\/li\u003e\n\n\u003c\/ul\u003e\u003ch3\u003eProduct video\u003c\/h3\u003e\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/2ZQmVEE47Xk\" title=\"Majestic Echelon II Series Gas Fireplace\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\" loading=\"lazy\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEchelon II firebox with 5 mm ceramic glass assembly\u003c\/li\u003e\n\u003cli\u003eStandard glass media package (up to 6 bags installed) and LED ember-bed lighting\u003c\/li\u003e\n\u003cli\u003eIntelliFire Touch ignition with RC400 touchscreen remote (factory paired)\u003c\/li\u003e\n\u003cli\u003eBattery backup tray (4 AA)\u003c\/li\u003e\n\u003cli\u003eExhaust restrictor for tall vertical runs (pp.32–39)\u003c\/li\u003e\n\u003cli\u003eInstallation and owner's manuals\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFront: Clean Face Trim (Black, Gunmetal, New Bronze or Stainless) or Picture Frame Front (Black); the fireplace must not run without an approved front\u003c\/li\u003e\n\u003cli\u003eEchelon II 60 requires a direct vent (DVP, or SLP with a power vent) venting system, not included with purchase.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLPK-ECHEL60 natural gas to propane conversion kit\u003c\/li\u003e\n\u003cli\u003eBGK-60 reflective black ceramic glass liner\u003c\/li\u003e\n\u003cli\u003eAlternate glass media: GLASS-BZ, GLASS-DM, GLASS-OY, GLASS-SP (6 bags)\u003c\/li\u003e\n\u003cli\u003eLOGS-DRTWOOD-60 Driftwood log set and STONES-NATURAL stone kit\u003c\/li\u003e\n\u003cli\u003eIFT-WFM IntelliFire Wi-Fi module; IFT-RC150 wireless wall switch; BATTERY-WSK battery backup wall switch kit; IFT-RC400 replacement remote\u003c\/li\u003e\n\u003cli\u003eHeat management: HEAT-ZONE-GAS with HZLIN-ADP, HEAT-OUT-GAS, HEAT-OUT-BEK, PH-MCE with PH-FRTTRIM-60, PHFR-MCE-60 with PHTRIM-MCE-60, PH-SIDETRIM\u003c\/li\u003e\n\u003cli\u003ePower vent kits and decorative vent terminations (manual sect. 12)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/2608_980_ECHEL36486072-C_INSTALL.pdf\"\u003eEchelon II installation manual 2608-980 (Rev Z, Nov 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/2608_981_ECHEL36486072-C_OWNER.pdf\"\u003eEchelon II owner's manual and warranty 2608-981 (Rev X, Mar 2026)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/brochures\/MAJ-0011U_EchelonII_broc_2-page.pdf\"\u003eEchelon II brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Majestic requires installation and service by a qualified installer, service agency or gas supplier, following the installation manual and local codes (installation manual 2608-980, cover and p.4). If you ever smell gas, do not light any appliance, do not use electrical switches or phones in the building, leave the building and call your gas supplier from a neighbor's phone.\u003c\/p\u003e\u003ch4\u003eProduct \u0026amp; safety information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUL listed as a direct vent heater to CSA\/ANSI Z21.88-2019 \/ CSA 2.33-2019 (supplemental heat, not a primary heat source) (p.4).\u003c\/li\u003e\n\u003cli\u003eApproved for bedrooms and bed-sitting rooms, and for OEM installation in manufactured homes (p.4).\u003c\/li\u003e\n\u003cli\u003eInput ratings are for 0–2,000 ft. In the U.S. reduce input 4% per 1,000 ft above 2,000 ft; in Canada no reduction up to 4,500 ft (p.4).\u003c\/li\u003e\n\u003cli\u003eOnly 5 mm ceramic replacement glass may be used; the barrier must be installed whenever the fireplace runs (p.4).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations have additional requirements (p.6).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003ePlanning the installation\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDecide the front style (Clean Face Trim or Picture Frame), finish thickness and any heat management kit before framing; they change framing and clearances (pp.7, 63).\u003c\/li\u003e\n\u003cli\u003eWall surfaces above the opening get warm; the Good Faith wall-temperature figures help plan TV placement (pp.8–9).\u003c\/li\u003e\n\u003cli\u003eInspect the appliance and components before installing (p.10).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFraming \u0026amp; clearances\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFramed opening 72-1\/4 x 48 x 18-1\/4 in.; 0 in. to combustible flooring (pp.16–18).\u003c\/li\u003e\n\u003cli\u003eExterior chases must be insulated and sealed like an exterior wall (p.26).\u003c\/li\u003e\n\u003cli\u003eFloor protection is not required on combustible floors; see vinyl-floor guidance (p.27).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUse only Hearth \u0026amp; Home DVP vent components; do not mix brands or share the vent with another appliance (p.28).\u003c\/li\u003e\n\u003cli\u003eMaximum three 90° (or six 45°) elbows; vertical runs from 2.5 ft up to 50 ft; combined vertical plus horizontal up to 63 ft with up to 23–24 ft horizontal (pp.31–39).\u003c\/li\u003e\n\u003cli\u003eTermination clearances include 12 in. above grade and from opening windows\/doors, 3 ft from gas meters, 7 ft above public walkways (p.30).\u003c\/li\u003e\n\u003cli\u003eAn exhaust restrictor may be needed on vertical runs of 20–50 ft (pp.32–39).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAppliance preparation\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSet the top standoffs, install any heat management kit, then secure and level the unit (pp.43–45).\u003c\/li\u003e\n\u003cli\u003eInstall the non-combustible facing as specified (p.46).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eElectrical\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eRun unswitched 110–120 VAC with 14-2 AWG wire and ground; GFCI where codes require (p.55).\u003c\/li\u003e\n\u003cli\u003eDo not wire the junction box to a switched circuit; batteries are for emergency backup only (pp.55–57).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas inlet 5.0–10.0 in. w.c. (7.0 recommended), manifold 3.5 in. w.c.; propane inlet 11.0–13.0 in. w.c. (12.0 recommended), manifold 10.0 in. w.c. (p.59).\u003c\/li\u003e\n\u003cli\u003ePressure above 1\/2 PSIG damages the valve; 1\/2 in. NPT connection at the shutoff valve (pp.59–61).\u003c\/li\u003e\n\u003cli\u003ePropane conversion only with the certified LPK kit, by a qualified installer (p.58).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinishing\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFinishing materials must withstand 190°F; seal gaps with 300°F sealant (p.62).\u003c\/li\u003e\n\u003cli\u003eClean Face Trim: overlap fit for 0–1 in. finish, inside fit for 1–4 in.; a non-combustible hearth up to 12 in. deep only with inside fit (pp.66–68).\u003c\/li\u003e\n\u003cli\u003eFollow the mantel and wall projection charts (pp.71–73).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAppliance setup\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUse no more than 6 bags of media in a single layer; keep media off the pilot area and the right-side burner area; install logs before media (pp.75–77).\u003c\/li\u003e\n\u003cli\u003ePair the RC400 remote and install the decorative barrier front before first use (p.78).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire \u0026amp; everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: run on high 3–4 hours, cool, clean the glass, then run another 6–12 hours with windows open; a paint-curing odor is normal (owner manual).\u003c\/li\u003e\n\u003cli\u003eHot glass causes burns: never let children touch it, supervise children and use the remote child lock; media is a choking hazard (owner manual).\u003c\/li\u003e\n\u003cli\u003eHave a qualified technician inspect the fireplace at least once a year (owner manual).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eGas installation: follow local codes or, where none apply, the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e (U.S.) or the \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1 Natural Gas and Propane Installation Code\u003c\/a\u003e (Canada)\u003c\/li\u003e\n\u003cli\u003eElectrical: wire and ground to local codes or, where none apply, the \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e (U.S.) or the \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (Canada)\u003c\/li\u003e\n\u003cli\u003eManufactured (mobile) homes: OEM installation to the \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, Title 24 CFR Part 3280\u003c\/a\u003e (U.S.) or \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/2703320\/\"\u003eCAN\/CSA Z240 MH Series\u003c\/a\u003e (Canada)\u003c\/li\u003e\n\u003cli\u003eMassachusetts: installation by a licensed plumber or gas fitter under the \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003eMassachusetts fuel gas code (248 CMR)\u003c\/a\u003e; side-wall vents under 7 ft need a hard-wired CO detector with battery backup meeting \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034\u003c\/li\u003e\n\u003cli\u003eNon-combustible materials are defined by ASTM E136 (published by ASTM International)\u003c\/li\u003e\n\u003cli\u003eAttic insulation shield where the vent passes an insulated attic, per the International Fuel Gas Code (ICC)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Hearth \u0026amp; Home Technologies (HHT) Limited Lifetime Warranty, form 4021-645N (12\/23), printed in the Echelon II owner's manual 2608-981 Rev X, pp.4–5. Majestic is an HHT brand.\u003c\/li\u003e\n\u003cli\u003eAll parts and material, including handles and external enameled components: 1 year parts and labor (subject to the warranty conditions and exclusions).\u003c\/li\u003e\n\u003cli\u003eElectrical components (modules, remotes and wall switches, valves, pilots, blowers, junction boxes, wire harnesses, transformers and lights, excluding bulbs): 2 years.\u003c\/li\u003e\n\u003cli\u003eCement refractory panels and glass liner panels: 2 years.\u003c\/li\u003e\n\u003cli\u003eBurners, logs and metal\/fiber refractory components of HHT-manufactured fireplaces: 10 years parts, 1 year labor.\u003c\/li\u003e\n\u003cli\u003eFirebox and heat exchanger: 20 years parts, 3 years labor.\u003c\/li\u003e\n\u003cli\u003ePurchased replacement parts and optional accessories: 1 year parts, no labor.\u003c\/li\u003e\n\u003cli\u003eWho is covered: products bought from an HHT authorized dealer or distributor. Coverage transfers to later owners while the product stays at its original installation site, but the period is not extended. Valid only in the country where the selling dealer is authorized.\u003c\/li\u003e\n\u003cli\u003eWhen coverage starts: on the date of installation (new construction: six months after the final sale invoice, and no later than 24 months after HHT ships the product).\u003c\/li\u003e\n\u003cli\u003eHow service works: warranty service is arranged through the installing dealer or distributor. Travel and parts-shipping charges are not covered.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: normal wear items (paint, gaskets, firebricks, grates, flame guides, batteries, glass discoloration), normal finish color changes, noise from normal expansion and contraction, and damage from improper installation, operation or maintenance, code violations, negative pressure or inadequate ventilation, power interruptions, unauthorized modifications, non-HHT venting or a fuel other than the one specified. HHT does not guarantee heating capacity for a given space.\u003c\/li\u003e\n\u003cli\u003eThe warranty is void if the product is over-fired, operated in a chlorine- or fluorine-contaminated atmosphere, or damaged by prolonged dampness, condensation or water from improper venting.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — ECHEL60IN-C\u003c\/h3\u003e\n\u003ch4\u003eWhat size framing does the ECHEL60IN-C need?\u003c\/h4\u003e\u003cp\u003eThe framed opening is 72-1\/4\" W × 48\" H × 18-1\/4\" D, adjusted for any interior sheathing. The fireplace itself measures 70\" W × 47-3\/4\" H × 17-1\/8\" D and needs 0\" clearance to a combustible floor.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt uses Hearth \u0026amp; Home DVP direct vent pipe off the top, run horizontally or vertically. Vertical runs go from 2.5 ft up to 50 ft, combined vertical and horizontal runs up to 63 ft, with up to three 90° elbows and at least 18\" of rise before the first elbow. An optional power vent lets the vent run up, down or sideways where a normal route won't work.\u003c\/p\u003e\n\u003ch4\u003eHow much heat does it put out?\u003c\/h4\u003e\u003cp\u003eIt is rated 28,000–50,000 BTU\/h on natural gas and 20,000–37,500 BTU\/h on propane, and Majestic rates it for up to 2,150 sq ft. It is certified as a direct vent heater for supplemental zone heat.\u003c\/p\u003e\n\u003ch4\u003eCan the ECHEL60IN-C run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It ships for natural gas and converts to propane with the LPK-ECHEL60 conversion kit, installed by a qualified installer.\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Four AA batteries in the factory battery tray keep the fire running when the power is out. The LED lights and any fans need AC power, so they stay off until power returns.\u003c\/p\u003e\n\u003ch4\u003eIs a remote included?\u003c\/h4\u003e\u003cp\u003eYes. The IntelliFire Touch RC400 touchscreen remote comes factory paired and controls on\/off, flame height, lights, timer, thermostat mode and child lock. The optional IFT-WFM Wi-Fi module adds app control and Amazon Alexa or Google Assistant voice control.\u003c\/p\u003e","brand":"Majestic","offers":[{"title":"Default Title","offer_id":50593310343330,"sku":"ECHEL60IN-C","price":8359.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Majestic-Echelon-II-60-Direct-Vent-Natural-Gas-Linear-Gas-Fireplace-ECHEL60IN-C_2086__86567.1786626063.1280.1280.jpg?v=1791682169","url":"https:\/\/unitedfireplaces.com\/products\/majestic-echelon-ii-60-fireplace-with-intellifire-echel60in-c","provider":"United Fireplaces","version":"1.0","type":"link"}