{"product_id":"kingsman-zcvrb72-72-linear-gas-fireplace-zcvrb72","title":"Kingsman ZCVRB72 72\" Linear Gas Fireplace ZCVRB72","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman ZCVRB72 is a 72-inch zero-clearance linear direct vent gas fireplace for homeowners who want a long, modern ribbon of flame as the focal point of a living room, great room or bedroom. It sits inside a framed chase with 0\" clearance at the back, sides and top standoffs, so it fits flush-to-wall, corner, island and room-divider layouts as well as exterior walls.\u003c\/p\u003e\u003cp\u003eThe look is clean and contemporary: a wide 73-7\/8\" x 20\" viewing area with flames dancing across decorative bronze ember glass, which ships with the fireplace. You can change the mood with multi-coloured cannonballs, alternative glass colours or Kingsman's driftwood, birch and oak linear log sets, add a porcelain reflective liner to multiply the flame, and finish the opening with a black or stainless surround or a tile-lip kit for a frameless finish.\u003c\/p\u003e\u003cp\u003eHeat output is up to 50,000 BTU\/h on natural gas or propane, with a Hi\/Lo valve that lets you turn the flame and heat down for milder days. Kingsman lists a fireplace efficiency (FE) of 53.14% MV \/ 53.64% IPI. It is certified as a vented room heater and approved for bedrooms, bed-sitting rooms and manufactured homes, so it can serve as zone heat in the room you use most.\u003c\/p\u003e\u003cp\u003eChoose millivolt ignition, which needs no house power and keeps working in a power failure, or IPI electronic ignition with battery backup. IPI models can be paired with Proflame remotes (on\/off, thermostatic, modulating and fan control), and the Proflame 2 remote on IPI PF2 models adds flame-height modulation and multi-colour LED accent lighting control. A heat-activated variable-speed fan kit and wall thermostats are optional.\u003c\/p\u003e\u003cp\u003eVenting is 5\"\/8\" (Kingsman Z-Flex 5\"\/8\" flex or listed 5\"\/8\" rigid direct vent), routed horizontally through the wall or vertically through the roof, with an optional PVH58 power vent for long or difficult runs. The chase can be left unvented, or vented with a front grill, side grills or an open top to create Kingsman's Cool Touch Wall: a vented chase runs about 40% cooler and drops the minimum mantel height from 40-1\/2\" to 28\", which also makes a TV above the fireplace practical.\u003c\/p\u003e\u003cp\u003eThe 72 is the largest fireplace in the Kingsman range, with nearly six feet of flame and the highest output of the ZCVRB family; it is the only ZCVRB with ceramic glass as standard.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear direct vent design\u003c\/strong\u003e: sealed combustion draws outside air and exhausts outdoors through 5\"\/8\" venting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance installation\u003c\/strong\u003e: 0\" to combustibles at the back, sides, floor and top standoffs; 36\" in front (manual pp.18, 26).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt valve\u003c\/strong\u003e: standard on millivolt models; operates during power failures with no electricity needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIPI electronic ignition (optional models)\u003c\/strong\u003e: intermittent pilot ignition with battery backup; a cold-climate (standing pilot) setting is available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDecorative bronze ember glass\u003c\/strong\u003e: included and required: the fireplace must not run without the glass embers on the burner and media tray.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCeramic glass front\u003c\/strong\u003e: 73-7\/8\" x 20\" viewing area.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included over the glass to reduce the risk of burns from the hot glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 50,000 BTU\/h maximum input on natural gas and propane; Hi\/Lo turndown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 53.14% MV \/ 53.64% IPI (Kingsman specification).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: mobile\/manufactured home, bedroom and bed-sitting room approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVented chase option (Cool Touch Wall)\u003c\/strong\u003e: vent the chase with grills or an open top for cooler walls and a lower 28\" mantel; minimum free area 285 sq in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure grills (optional)\u003c\/strong\u003e: VL72EG front grill (78-5\/8\" x 3-5\/8\" opening, 285 sq in); VL72EGS side grills, pair (two 15-1\/4\" x 9\" openings, 285 sq in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurround (optional)\u003c\/strong\u003e: ZCVRB72S1BL black or ZCVRB72S1SS stainless steel, covers 76-3\/4\" W x 23\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z46FK heat-activated fan with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal light kit (optional)\u003c\/strong\u003e: ULK64 four-lamp universal light kit (12 VAC halogen) for accent lighting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall thermostat (optional)\u003c\/strong\u003e: standard on\/off or programmable 5-day\/2-day models (Z2MT, Z80PT).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote controls (optional)\u003c\/strong\u003e: on\/off, thermostatic, thermostatic modulating, and thermostatic modulating with fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (IPI PF2 models)\u003c\/strong\u003e: flame-height modulation and multi-colour LED accent lighting control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH puts the IPI backup batteries in an accessible wall box within 16 ft of the valve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiner option\u003c\/strong\u003e: ZCVRB72PL porcelain reflective liner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedia options\u003c\/strong\u003e: RBCB1 multi-coloured cannonballs, alternative glass colours and linear log sets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 or PVH58FM power vent for extended horizontal runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: NG\/LP conversion kits available (72ZCVRB-CKLP \/ -CKNG (millivolt); 72ZCVRB-CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI)).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19 \/ CSA 2.33-19 vented gas fireplace heater; CSA 2.17-2017 (high altitude).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eZCVRB72N \/ ZCVRB72LP (millivolt); ZCVRB72NE \/ ZCVRB72LPE (IPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eZero-clearance linear direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e78-3\/4\" W x 40-5\/16\" H x 19-3\/8\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eRough-opening size not published by the manufacturer. Framing goes directly to the fold-out standoffs (0\" at the back, sides and top) and must not extend past them; minimum ceiling\/enclosure height 79\" from the bottom of the fireplace; no hearth required (manual pp.10, 17–18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e73-7\/8\" W x 20\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eFront 36\"; back, sides, top standoffs and floor 0\"; ceiling at least 79\" above the bottom of the fireplace; combustible mantel at least 40-1\/2\" above the bottom of the unit (unvented chase) or 28\" (vented chase); vent pipe: top of a 90° bend 4\", top of horizontal pipe 2\", sides and bottom of horizontal pipe 1\", vertical pipe 1\" (pp.14, 17–18, 26)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e50,000 \/ 34,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e50,000 \/ 39,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e53.14% MV \/ 53.64% IPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic, with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e5\"\/8\" (Kingsman Z-Flex 5\"\/8\" flex or listed 5\"\/8\" rigid direct vent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e120 VAC grounded receptacle for fan \/ IPI adapter; millivolt runs without power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMedia included\u003c\/th\u003e\n\u003ctd\u003eDecorative bronze ember glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum media load\u003c\/th\u003e\n\u003ctd\u003e15 lb (10 lb with logs or stones)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprovals\u003c\/th\u003e\n\u003ctd\u003eBedroom, bed-sitting room, manufactured\/mobile home\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHorizontal-vent framing height: 71\" minimum, plus 1\/4\" of rise per foot (p.17).\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing (unvented chase): at least 32-1\/2\" x 79-1\/8\"; recommended 35-3\/4\" x 80-5\/8\" (p.19).\u003c\/li\u003e\n\u003cli\u003eVented chase: minimum enclosure height 79\"; minimum free opening 285 sq in; grills within 3\/4\" of the sealed enclosure top; open top 2-3\/8\" minimum on three sides (pp.13, 21–24).\u003c\/li\u003e\n\u003cli\u003eTV above the fireplace: recommended only with a vented chase (or the recessed option); keep the TV at least 1\" from the vent grill or opening (pp.14, 25).\u003c\/li\u003e\n\u003cli\u003eAppliance weight: not listed in the manual text.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with linear burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eDecorative bronze ember glass\u003c\/li\u003e\n\u003cli\u003eCeramic glass front\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier\u003c\/li\u003e\n\u003cli\u003eNailing tabs (two per side) and standoffs\u003c\/li\u003e\n\u003cli\u003eRemovable lower face panel\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e5\"\/8\" direct vent pipe and a matching horizontal or vertical termination (Kingsman Z-Flex or a listed rigid system)\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing over the face of the fireplace in an unvented chase (minimum 32-1\/2\" x 79-1\/8\")\u003c\/li\u003e\n\u003cli\u003eFor a vented chase: VL72EG front grill, VL72EGS side grills, pair, a custom grill, or an open top meeting the minimum free area\u003c\/li\u003e\n\u003cli\u003eGas supply with a manual shutoff valve (3\/8\" NPT inlet; 1\/2\" rigid pipe or an approved flex connector such as FP15GC)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan kit or IPI models (split receptacle installed by an electrician)\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup and remote receiver\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZCVRB72S1BL black surround trim kit\u003c\/li\u003e\n\u003cli\u003eZCVRB72S1SS stainless steel surround trim kit\u003c\/li\u003e\n\u003cli\u003eZCVRB72PL porcelain reflective panel liner\u003c\/li\u003e\n\u003cli\u003eRBCB1 multi-coloured cannonballs\u003c\/li\u003e\n\u003cli\u003eZ46FK fan kit with variable speed control\u003c\/li\u003e\n\u003cli\u003eULK64 universal light kit\u003c\/li\u003e\n\u003cli\u003eZ2MT digital or Z80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eGTRC \/ GTMRCN \/ GTMRCP \/ GTFRCN \/ GTFRCP millivolt remotes\u003c\/li\u003e\n\u003cli\u003eEGTRC \/ EGTMRCN \/ EGTMRCP \/ EGTFRCN \/ EGTFRCP IPI Proflame remotes\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI)\u003c\/li\u003e\n\u003cli\u003ePVH58 \/ PVH58FM power vent with PVC58MV or PVC58IPI control module\u003c\/li\u003e\n\u003cli\u003eVL72EG front grill and VL72EGS side grills, pair (vented chase)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2024\/01\/72ZCV-MAN19-8.pdf\"\u003eZCVRB72 installation and operating manual (72ZCV-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/07\/21056-KM-B102-ZCVRB47-60-72ENG-July2025-FNL1-Web.pdf\"\u003eZCVRB47\/60\/72 brochure and specifications (July 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (ZCVRB72 installation and operating manual (72ZCV-MAN19), cover and pp.5–7). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.4–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19 and CSA 2.33-19 as a vented gas fireplace heater (cover). It is not meant as a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for bedrooms and bed-sitting rooms (in Canada with a listed millivolt thermostat) and for manufactured\/mobile homes where local codes allow; manufactured-home installs need an 8 AWG copper ground to the chassis (pp.7–8).\u003c\/li\u003e\n\u003cli\u003eGas orifices are sized for 0–4,500 ft elevation; installations above that need the orifice sizing confirmed (p.43).\u003c\/li\u003e\n\u003cli\u003eIndoor appliance. A covered outdoor location is allowed only for basic millivolt models without fan or lights, with a roof overhang and no operation below 32°F (p.9).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFraming, chase and clearances (pp.10–28)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMinimum ceiling\/enclosure height 79\" from the bottom of the fireplace; front clearance 36\"; 0\" at the back, sides, floor and top standoffs (pp.17–18, 26).\u003c\/li\u003e\n\u003cli\u003eFold out and screw the standoffs before installing; framing must not extend past them. No hearth is required (p.10).\u003c\/li\u003e\n\u003cli\u003eRun horizontal venting straight out the back wall above the flue with a wall thimble; no horizontal runs or offsets inside the enclosure (pp.11, 16).\u003c\/li\u003e\n\u003cli\u003eUnvented chase: non-combustible facing at least 32-1\/2\" x 79-1\/8\"; mantel 40-1\/2\" above the bottom of the unit (pp.14, 19–20).\u003c\/li\u003e\n\u003cli\u003eVented chase: 285 sq in minimum free opening, minimum enclosure height 79\"; mantel 28\"; combustible facing such as drywall is allowed in a vented chase (pp.14–15, 21–27).\u003c\/li\u003e\n\u003cli\u003eUse 1\/2\" minimum concrete board and self-tapping screws no longer than 2\". Granite and tile cracking or discoloration is not covered by the warranty (p.15).\u003c\/li\u003e\n\u003cli\u003eA combustible hearth may sit below the appliance opening (pp.20, 27).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eComponents, trim and liners (pp.29–42)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSurround ZCVRB72S1BL \/ ZCVRB72S1SS covers 76-3\/4\" W x 23\" H; frames are 3\/4\" thick, with gap options of 5\/8\", 7\/8\" or 1-1\/8\", and non-combustible facing up to 1\" thick may run under it.\u003c\/li\u003e\n\u003cli\u003eThe Z46FK fan installs with its speed control outside the firebox; a split receptacle provides constant power inside the unit and must be installed by a qualified electrician (pp.33–34).\u003c\/li\u003e\n\u003cli\u003eNever operate with the glass door removed, cracked or broken; replacement glass must be the Kingsman part (pp.5–6, 35).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.43–51)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.43).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.43).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe (natural gas) with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC. Disconnect the appliance for pressure tests above 1\/2 psig (p.43).\u003c\/li\u003e\n\u003cli\u003eField conversion between natural gas and propane uses the Kingsman kits 72ZCVRB-CKLP \/ -CKNG (millivolt); 72ZCVRB-CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI), installed by a qualified agency (pp.48–50).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician; check the flame monthly.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eElectrical\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity to run. Do not wire 120 V to millivolt switches or thermostats; wall-switch wire runs are limited by gauge (e.g. 18 AWG up to 40 ft).\u003c\/li\u003e\n\u003cli\u003eThe fan kit, light kit and IPI adapter need a grounded three-prong 120 VAC receptacle; do not remove the ground prong (pp.6, 33–34).\u003c\/li\u003e\n\u003cli\u003eIPI battery backup runs the fire during a power outage on four AA batteries; fans and lights do not run on battery. Replace them before each heating season.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMedia, logs and lighting (pp.52–63)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSpread the decorative glass embers on the burner and media tray before use (maximum 15 lb (10 lb with logs or stones)); never cover the pilot, and the pilot must be visible when lighting.\u003c\/li\u003e\n\u003cli\u003eApproved options include RBCB1 cannonballs, glass colours and Kingsman linear log sets; the ULK64 light kit runs on a 12 VAC transformer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eIPI and Proflame controls (pp.64–78)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eIPI models can run in intermittent pilot mode or a cold-climate standing-pilot mode, which keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eThe Proflame 2 system has a 24-hour safety shut-off if the remote is not heard from; the WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.79–87)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: 5\"\/8\" (Kingsman Z-Flex 5\"\/8\" flex or listed 5\"\/8\" rigid direct vent). Only components listed for this appliance may be used, and systems must not be mixed.\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 71\"; maximum vertical 43 ft; maximum horizontal 20 ft (with an 8 ft rise); 1\/4\" of rise per 12\" of horizontal run (p.82).\u003c\/li\u003e\n\u003cli\u003eElbows: up to four 45° bends (18\" each) plus two more 90° bends (36\" each) (p.82).\u003c\/li\u003e\n\u003cli\u003eRestrictor: set the flue restrictor by vent length: wide open at 15–20 ft, #1 at 25 ft, #2 at 30 ft, #3 at 35 ft, #4 at 40 ft (p.85).\u003c\/li\u003e\n\u003cli\u003eKey terminal clearances: 12\" above grade, decks and balconies; 9\" from openable windows and doors (10,000–50,000 BTU\/h class); 18\" from a ventilated soffit; 24\" from an adjacent wall; 7 ft above public walkways; 3 ft from a gas meter or regulator; terminate at least 18\" above the roof. Keep combustibles 24\" from the hot termination cap.\u003c\/li\u003e\n\u003cli\u003ePower venting (PVH58 \/ PVH58FM) is approved for long horizontal runs; downward runs are allowed only on IPI models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use (p.5)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out during curing.\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting.\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, and do not use the fireplace if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.8).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.7).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (ZCVRB72 installation and operating manual (72ZCV-MAN19), p.92).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — ZCVRB72\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the ZCVRB72 need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: framing goes right to the fold-out standoffs with 0\" clearance at the back, sides and top, and must not extend past them. The enclosure needs at least 79\" of height from the bottom of the fireplace, and no hearth is required. The unit measures 78-3\/4\" W × 40-5\/16\" H × 19-3\/8\" D.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 5\"\/8\" direct vent pipe (Kingsman Z-Flex flex or listed 5\"\/8\" rigid). Vertical runs go from 71\" minimum to 43 ft maximum, and horizontal runs up to 20 ft with an 8 ft rise, sloped up 1\/4\" per foot.\u003c\/p\u003e\n\u003ch4\u003eCan the ZCVRB72 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It comes in natural gas and propane versions at up to 50,000 BTU\/h on either fuel, and field conversion kits are available: 72ZCVRB-CKLP for millivolt models and 72ZCVRB-CKLPI or 72ZCVRB-CKLP2 for IPI models.\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models keep the fire running on four AA backup batteries; the fan and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eCan a TV go above it, and how high must the mantel be?\u003c\/h4\u003e\u003cp\u003eA TV above is recommended only with a vented chase (or the recessed option), kept at least 1\" from the vent grill or opening. A combustible mantel must be at least 40-1\/2\" above the bottom of the unit with an unvented chase, or 28\" with a vented chase.\u003c\/p\u003e\n\u003ch4\u003eWhat's the warranty?\u003c\/h4\u003e\u003cp\u003eDefective components are covered for parts and labour for the first year after installation, except accent light bulbs, gasketing, glass fronts and paint. The heat exchanger, combustion chamber and burner carry a limited lifetime warranty for as long as the original owner owns the fireplace; after the first year the defective part is exchanged, and labour and freight are not covered.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912049430690,"sku":"ZCVRB72N","price":10007.76,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912049463458,"sku":"ZCVRB72LP","price":10093.49,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912049496226,"sku":"ZCVRB72NE","price":10472.65,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI","offer_id":50912049528994,"sku":"ZCVRB72LPE","price":10472.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/ZCVRB47-60-WEB-6_059a1f59-b9a7-497e-a55b-e0caa7317c0e.jpg?v=1795038112","url":"https:\/\/unitedfireplaces.com\/products\/kingsman-zcvrb72-72-linear-gas-fireplace-zcvrb72","provider":"United Fireplaces","version":"1.0","type":"link"}