{"product_id":"kingsman-idv26-direct-vent-gas-fireplace-insert-idv26","title":"Kingsman IDV26 Direct Vent Gas Fireplace Insert IDV26","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman IDV26 is a direct vent gas fireplace insert that turns an existing wood-burning masonry fireplace, or a listed zero-clearance factory-built wood fireplace, into a sealed, efficient gas fire. It is the wide model of the IDV insert range and suits homeowners who want real heat and push-button convenience from a fireplace they rarely use.\u003c\/p\u003e\u003cp\u003eA dual burner with glowing embers lights the LOGF27 Fibre Split Oak log set or the RSP10 glass support platform with 15 lb of bronze glass. An IDV26RL refractory brick or IDV26PRL porcelain reflective liner sets the look inside, and a black I26CV1BL, I26CV2BL or I26CV3BL Clean View front, or an I26CVPF1BL or I26CVPF2BL picture-frame Clean View, finishes the opening. Input is 28,500 BTU\/h on natural gas and 28,000 BTU\/h on propane, at a fireplace efficiency of 65.25% MV \/ 67.37% IPI (NG).\u003c\/p\u003e\u003cp\u003eHeat-radiating ceramic glass and a standard heat-activated variable-speed blower push warmth into the room. A millivolt valve needs no house power and IPI ignition has battery backup, so the fire keeps working in a power outage; E2 models include a Proflame 2 remote. It vents up the existing chimney through a 3\"\/3\" co-linear liner to an IDVVT36 cap, 12 to 40 ft vertical.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect vent fireplace insert\u003c\/strong\u003e: sealed combustion for existing masonry or listed factory-built fireplaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual burner\u003c\/strong\u003e: with glowing embers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMillivolt or IPI valve\u003c\/strong\u003e: operates during power failures, with adjustable flame control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-radiating ceramic glass\u003c\/strong\u003e: Robax or coated Neoceram, 5 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-activated blower\u003c\/strong\u003e: with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn\/off rocker switch\u003c\/strong\u003e: for simple manual operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (E2 models)\u003c\/strong\u003e: flame, fan, thermostat and smart-thermostat control; battery backup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included with the Clean View front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 28,500 \/ 19,500 BTU\/h natural gas; 28,000 \/ 23,000 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 65.25% MV \/ 67.37% IPI (NG); 66.30% \/ 68.30% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: bedroom and mobile\/manufactured home (USA) approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame display\u003c\/strong\u003e: LOGF27 Fibre Split Oak log set, or RSP10 glass support platform with 15 lb of bronze glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean View fronts\u003c\/strong\u003e: I26CV1BL, I26CV2BL or I26CV3BL Clean View front, or I26CVPF1BL \/ I26CVPF2BL picture-frame Clean View.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounds\u003c\/strong\u003e: I26S1BL slim, I26SPF1BL slim picture frame or I26SUBL universal surround.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: IDV26PRL porcelain reflective or IDV26RL refractory brick liner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRisers (optional)\u003c\/strong\u003e: I33R40 \/ I33R44 risers to fit taller openings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMantel clearance shield (optional)\u003c\/strong\u003e: I33CS lowers the minimum combustible mantel height.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall thermostat (optional)\u003c\/strong\u003e: standard on\/off or programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional, millivolt \/ PF1)\u003c\/strong\u003e: on\/off, thermostatic, thermostatic modulating and fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCo-linear venting\u003c\/strong\u003e: 3\"\/3\" through the existing chimney with the IDVFK25 flex kit and IDVVT36 termination; 12 to 40 ft vertical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: kits 26IDV-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKLP2 \/ -CKNGI \/ -CKNG2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eIDV26N \/ IDV26LP (millivolt); IDV26NE2 \/ IDV26LPE2 (IPI Proflame 2 with remote)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eDirect vent gas fireplace insert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e33\" W (components in) or 28\" W (components out) x 19-1\/2\" H x 14-1\/4\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eMinimum fireplace opening, components in: 33\" front width centred (31\" if not centred), 22\" back width, 19-1\/2\" H, 14-1\/4\" D; components out: 28\" front width, 22\" back width, 19-1\/2\" H, 14-1\/4\" D (p.12). Fits a masonry fireplace or a listed zero-clearance factory-built solid-fuel fireplace (p.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eInstalls inside an existing fireplace; the floor under the insert must be non-combustible, with a minimum hearth of 3\/4\" x 12-1\/2\" x 31\" W (p.34); wall coverings closer than the combustible-materials line must be non-combustible (p.34); combustible mantel 35-3\/8\" to 45-3\/8\" above the bottom of the unit as mantel depth increases (p.33), or 6-7\/8\" lower with the I33CS mantel clearance shield (p.35); leave 1\/2\" around the Clean View front so it can be removed for service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e28,500 \/ 19,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e28,000 \/ 23,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e65.25% MV \/ 67.37% IPI (NG); 66.30% \/ 68.30% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic (Robax or coated Neoceram), 5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e3\"\/3\" co-linear; IDVVT36 vertical termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eMillivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBlower\u003c\/th\u003e\n\u003ctd\u003eHeat-activated, variable speed (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eVenting and floor\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVenting: 12 ft minimum and 40 ft maximum vertical; horizontal offset up to 2 ft (p.68).\u003c\/li\u003e\n\u003cli\u003eThe floor beneath the insert must be non-combustible; keep 1\/2\" around the Clean View so it can be removed for service.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsert with dual burner and heat-activated variable-speed blower, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eCeramic glass front (Robax or coated Neoceram, 5 mm)\u003c\/li\u003e\n\u003cli\u003eProflame 2 remote (IDV26NE2 \/ IDV26LPE2 only)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne Clean View front: I26CV1BL, I26CV2BL or I26CV3BL Clean View, or I26CVPF1BL or I26CVPF2BL picture-frame Clean View (black)\u003c\/li\u003e\n\u003cli\u003eOne flame display: LOGF27 Fibre Split Oak log set, or RSP10 glass support platform with 15 lb of bronze glass\u003c\/li\u003e\n\u003cli\u003eIDVFK25 3\" flex pipe kit (two 25 ft lengths, for the 3\"\/3\" co-linear liner), or the MG DuraVent 46DVA-CL33 kit (termination cap and two 35 ft aluminium flex lengths)\u003c\/li\u003e\n\u003cli\u003eIDVVT36 3\"\/3\" co-linear vertical termination (with the IDVFK25 kit)\u003c\/li\u003e\n\u003cli\u003eIDVLCP lower chase sealant plate, sealed with red RTV silicone\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle\u003c\/li\u003e\n\u003cli\u003eA clean, sound chimney not shared with any solid-fuel appliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eI26S1BL slim surround, black\u003c\/li\u003e\n\u003cli\u003eI26SPF1BL slim picture-frame surround\u003c\/li\u003e\n\u003cli\u003eI26SUBL universal surround, black\u003c\/li\u003e\n\u003cli\u003eIDV26RL refractory brick liner\u003c\/li\u003e\n\u003cli\u003eIDV26PRL porcelain reflective panel liner\u003c\/li\u003e\n\u003cli\u003eI33R40 surround riser\u003c\/li\u003e\n\u003cli\u003eI33R44 surround riser\u003c\/li\u003e\n\u003cli\u003eI33CS mantel clearance shield\u003c\/li\u003e\n\u003cli\u003eZ2MT wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eGTRC remote (millivolt models)\u003c\/li\u003e\n\u003cli\u003eGTMRCN remote (millivolt models)\u003c\/li\u003e\n\u003cli\u003eGTMRCP remote (millivolt models)\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI models)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/26IDV-MAN19.pdf\"\u003eIDV26 installation and operating manual (26IDV-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/12\/21379-KM-B076-IDV26ENG-Nov2025-FNL1-Web.pdf\"\u003eIDV26 brochure and specifications (Nov 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (IDV26 installation and operating manual (26IDV-MAN19), safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.4–11)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for bedrooms and for manufactured\/mobile homes in the USA where local codes allow.\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFireplace requirements, dimensions and mantel (pp.12–27)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFits a masonry fireplace (leave the refractory in place) or a listed zero-clearance factory-built fireplace; minimum opening at least 33\" W x 19-1\/2\" H x 14-1\/4\" D with components in, or 28\" W with the CV2 components-out layout (pp.1, 12).\u003c\/li\u003e\n\u003cli\u003eIn a factory-built fireplace, the damper, grates, glass doors, screen rails and smoke baffle may need to be removed per the manual.\u003c\/li\u003e\n\u003cli\u003eMantel: with a Clean View front and no shield, 35-3\/8\" to 45-3\/8\" from the unit bottom depending on mantel depth (p.33); with the I33CS shield, 28-1\/2\" to 38-1\/2\" (p.35); hearth at least 3\/4\" x 12-1\/2\" x 31\" (p.34).\u003c\/li\u003e\n\u003cli\u003eNon-combustible floor beneath the insert; non-combustible facing in the area above the combustible-mantel line.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFronts, surrounds, liners and media (pp.12–27, 30–44)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFronts: I26CV1BL, I26CV2BL or I26CV3BL Clean View front, or I26CVPF1BL \/ I26CVPF2BL picture-frame Clean View. Surrounds: I26S1BL slim, I26SPF1BL slim picture frame or I26SUBL universal surround.\u003c\/li\u003e\n\u003cli\u003eMedia: LOGF27 Fibre Split Oak log set, or RSP10 glass support platform with 15 lb of bronze glass; follow the placement diagram and keep the pilot clear.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm Robax or coated Neoceram; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.45–51)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.48).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.48).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.48).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.48). Field conversion between natural gas and propane uses Kingsman kits 26IDV-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKLP2 \/ -CKNGI \/ -CKNG2 (IPI), installed by a qualified agency (pp.50–51).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and electrical (pp.51–65)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.51–65).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eGrounded three-prong plug required for the blower; do not wire 120 V to millivolt switches.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.68–73)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCo-linear liner: 3\"\/3\", Kingsman IDVFK25 flex kit with the IDVVT36 termination, or MG DuraVent kit 46DVA-CL33 (p.68).\u003c\/li\u003e\n\u003cli\u003eVertical rise 12 ft minimum, 40 ft maximum; up to 2 ft of horizontal offset.\u003c\/li\u003e\n\u003cli\u003eThe chimney must be cleaned and inspected (professionally if it served a wood fire), must not serve a solid-fuel appliance, and needs a rain cap with the gap between chimney and liner capped.\u003c\/li\u003e\n\u003cli\u003eSeal the lower chase with the IDVLCP block-off plate.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.8).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.7).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (IDV26 installation and operating manual (26IDV-MAN19), p.73).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — IDV26\u003c\/h3\u003e\n\u003ch4\u003eWhat size fireplace opening does the IDV26 need?\u003c\/h4\u003e\u003cp\u003eWith the controls inside the insert the opening must be at least 33\" wide at the front (centred; 31\" if the insert is not centred), 22\" wide at the back, 19-1\/2\" high and 14-1\/4\" deep. With the components-out layout the front width drops to 28\". It fits a masonry wood fireplace or a listed zero-clearance factory-built wood fireplace; the floor under the insert must be non-combustible.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents up the existing chimney through a 3\"\/3\" co-linear liner: the Kingsman IDVFK25 kit (two 25 ft lengths of 3\" flex) with the IDVVT36 vertical termination, or the MG DuraVent 46DVA-CL33 kit. The vertical rise is 12 ft minimum and 40 ft maximum, with up to 2 ft of horizontal offset. The lower chase is sealed with the IDVLCP plate, and the chimney must not serve any solid-fuel appliance.\u003c\/p\u003e\n\u003ch4\u003eCan the IDV26 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It is offered here in natural gas (IDV26N millivolt, IDV26NE2 IPI with Proflame 2) and propane (IDV26LP millivolt, IDV26LPE2 IPI with Proflame 2), rated 28,500 \/ 19,500 BTU\/h on natural gas and 28,000 \/ 23,000 BTU\/h on propane (max\/min). Field conversion uses Kingsman kits 26IDV-CKLP \/ -CKNG (millivolt) or -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity to run the fire. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in an outage; the blower needs house power and does not run on battery.\u003c\/p\u003e\n\u003ch4\u003eIs a remote included?\u003c\/h4\u003e\u003cp\u003eOn the IDV26NE2 and IDV26LPE2 (Proflame 2) models, yes. The millivolt IDV26N and IDV26LP take an optional GTRC, GTMRCN or GTMRCP remote, or a Z2MT or Z80PT wall thermostat.\u003c\/p\u003e\n\u003ch4\u003eHow high must a mantel be above the IDV26?\u003c\/h4\u003e\u003cp\u003eA combustible mantel must sit 35-3\/8\" to 45-3\/8\" above the bottom of the unit, higher as the mantel gets deeper. The optional I33CS mantel clearance shield lowers those heights by 6-7\/8\". A hearth of at least 3\/4\" x 12-1\/2\" x 31\" wide is required.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912070434978,"sku":"IDV26N","price":3367.72,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912070467746,"sku":"IDV26LP","price":3455.87,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI Proflame 2 with Remote","offer_id":50912070500514,"sku":"IDV26NE2","price":4421.87,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI Proflame 2 with Remote","offer_id":50912070533282,"sku":"IDV26LPE2","price":4507.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/IDV26-1.jpg?v=1795038539","url":"https:\/\/unitedfireplaces.com\/products\/kingsman-idv26-direct-vent-gas-fireplace-insert-idv26","provider":"United Fireplaces","version":"1.0","type":"link"}