{"product_id":"kingsman-fdv451-direct-vent-gas-stove-fdv451","title":"Kingsman FDV451 Direct Vent Gas Stove FDV451","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman FDV451 is a freestanding direct vent gas stove with a traditional cast-stove look in charcoal with flat black posts. It brings real stove character to living rooms, cottages, basements and additions with no chimney, and it is approved for bedrooms, bed-sitting rooms and, as a direct vent stove, mobile homes.\u003c\/p\u003e\u003cp\u003eA dual burner lights a realistic fire on the LOGF451 five-piece cast split oak log set over lava rock and embers, or on bronze glass with optional RBCB1 cannonballs. Inside, choose an F451RLT traditional or F451RLH herringbone brick liner or an F451PL reflective porcelain liner; the F450FBL door front and F451SDSBL side doors complete the body.\u003c\/p\u003e\u003cp\u003eInput is 34,500 BTU\/h on natural gas and 31,000 BTU\/h on propane, with Hi\/Lo flame and heat adjustment and a fireplace efficiency of up to 67.72% (NG) and 74.06% (LP). A millivolt valve needs no house power and IPI ignition has battery backup, so it keeps heating in a power outage; E2 models include a Proflame 2 remote. It vents through the wall or roof from a 4\"\/7\" collar, or into an existing chimney or B-vent with the F35BVC converter.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFreestanding direct vent stove\u003c\/strong\u003e: sealed combustion; outside air for the fire.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMillivolt or IPI valve\u003c\/strong\u003e: operates during a power failure with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (E2 models)\u003c\/strong\u003e: flame, fan, thermostat and smart thermostat control, with battery backup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual burner\u003c\/strong\u003e: with a realistic flame pattern.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-radiating ceramic glass\u003c\/strong\u003e: Robax or coated Neoceram, 5 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLog set\u003c\/strong\u003e: LOGF451 oak log set (or bronze glass \/ cannonballs with the media kit).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: supplied with the F450FBL door front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 34,500 \/ 23,750 BTU\/h natural gas; 31,000 \/ 24,500 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 65.89% MV \/ 67.72% IPI (NG); 72.14% \/ 74.06% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: mobile home approved (direct vent only); bedroom and bed-sitting room approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: F45FK heat activated with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall thermostat (optional)\u003c\/strong\u003e: Z2MT millivolt or Z80PT programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional, millivolt)\u003c\/strong\u003e: on\/off, thermostatic, thermostatic modulating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLog grate (optional)\u003c\/strong\u003e: F45LG.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBronze glass media (optional, in place of logs)\u003c\/strong\u003e: Z5GC (3 bags) or MQG5C, 15 lb maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-coloured cannonballs (optional)\u003c\/strong\u003e: RBCB1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTraditional brick liner (optional)\u003c\/strong\u003e: F451RLT.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHerringbone brick liner (optional)\u003c\/strong\u003e: F451RLH.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorcelain reflective liner (optional)\u003c\/strong\u003e: F451PL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharcoal door face and vent lid (required, sold separately)\u003c\/strong\u003e: F450FBL, with flat black posts and safety screen; the vent lid must be installed before venting (manual p.18).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharcoal solid-panel side doors (required, sold separately)\u003c\/strong\u003e: F451SDSBL; side doors are listed as required for each unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDecorative black 7\" collar (optional)\u003c\/strong\u003e: F7DBC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDecorative black wall trim plate (optional)\u003c\/strong\u003e: F7DTP.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB-vent adapter (optional)\u003c\/strong\u003e: F35BVC converts the stove to an existing 4\" B-vent or lined chimney.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: kits 450DV-CKNG \/ -CKLP (millivolt) and -CKNGI \/ -CKNG2 \/ -CKLPI \/ -CKLP2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eFDV451N \/ FDV451LP (millivolt); FDV451NE2 \/ FDV451LPE2 (IPI Proflame 2 with remote)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eFreestanding direct vent gas stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eNone required (freestanding). Alcove installation: at least 48\" deep, 71-1\/2\" high and 58\" wide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eFront 36\"; sides 15-1\/2\"; back 2-1\/2\"; ceiling 71-1\/2\" from the floor; top of a 90° elbow 2\"; top of horizontal pipe 1\"; vertical venting 1\". Floor: may sit directly on carpet, tile or other combustible flooring with no added floor protection; a hearth is recommended over vinyl flooring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e34,500 \/ 23,750 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e31,000 \/ 24,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e65.89% MV \/ 67.72% IPI (NG); 72.14% \/ 74.06% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic, 5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eDirect vent, 4\"\/7\" flue collar. Rigid DuraVent DirectVent Pro 4\" x 6-5\/8\" pipe with the Kingsman ZDVDKA stove adapter (horizontal or vertical termination); optional 4\" B-vent with F35BVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eMillivolt or IPI Proflame 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eStove with dual burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eCeramic glass (5 mm Robax or coated Neoceram)\u003c\/li\u003e\n\u003cli\u003eLava rock and embers (supplied with the base unit)\u003c\/li\u003e\n\u003cli\u003eProflame 2 remote (FDV451NE2 \/ FDV451LPE2 only)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLOGF451 five-piece cast split oak log set (listed as required for each unit), or bronze glass media in its place: Z5GC (3 bags) or MQG5C, 15 lb maximum; RBCB1 cannonballs are used with 15 lb of glass\u003c\/li\u003e\n\u003cli\u003eF450FBL door front, charcoal with flat black posts: door face with safety screen and vent lid (required for each unit; the vent lid must be in place before the venting is connected)\u003c\/li\u003e\n\u003cli\u003eF451SDSBL side doors, flat black frame with charcoal solid panel (side doors are listed as required for each unit)\u003c\/li\u003e\n\u003cli\u003eDirect vent pipe from the 4\"\/7\" collar: Kingsman (Z-Flex) venting components labelled for this stove, or DuraVent DirectVent Pro \/ DirectVent Pro Concentric Flex; BDM Pro Form, Ameri-Vent, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp are also approved\u003c\/li\u003e\n\u003cli\u003eZDVDKA DuraVent hard-pipe stove adapter (required with rigid DuraVent pipe)\u003c\/li\u003e\n\u003cli\u003eOne termination: FDVHSQ or FDVHT horizontal, Z47ST24 \/ Z47ST36 snorkel, or FDVVT40 \/ Z47VT vertical\u003c\/li\u003e\n\u003cli\u003eVertical installs: ZDVFS firestop spacer (required through floors and ceilings), ZDVAIS attic insulation shield (required through attic space), ZDV7SC storm collar and a ZDVAAF, ZDVAF2 or ZDVAF3 roof flashing\u003c\/li\u003e\n\u003cli\u003eOr, instead of direct vent pipe: F35BVC B-vent converter into an existing 4\" B-vent or lined chimney, 12 ft minimum to 60 ft maximum (direct vent models only are mobile home approved)\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan or IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eF45LG log grate\u003c\/li\u003e\n\u003cli\u003eF451RLT traditional brick liner\u003c\/li\u003e\n\u003cli\u003eF451RLH herringbone brick liner\u003c\/li\u003e\n\u003cli\u003eF451PL reflective porcelain liner (one back and two side panels)\u003c\/li\u003e\n\u003cli\u003eRBCB1 multi-coloured cannonballs\u003c\/li\u003e\n\u003cli\u003eF45FK fan kit with variable speed control\u003c\/li\u003e\n\u003cli\u003eF7DBC decorative black collar, 7\"\u003c\/li\u003e\n\u003cli\u003eFV7FBT decorative brass collar, 7\"\u003c\/li\u003e\n\u003cli\u003eF7DTP decorative black wall trim plate\u003c\/li\u003e\n\u003cli\u003eZ2MT millivolt wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable digital millivolt wall thermostat\u003c\/li\u003e\n\u003cli\u003eGFRC on\/off remote (millivolt \/ IPI)\u003c\/li\u003e\n\u003cli\u003eGTRC thermostat remote (millivolt)\u003c\/li\u003e\n\u003cli\u003eGTMRCN \/ GTMRCP thermostat \/ modulating remote, natural gas \/ propane (millivolt)\u003c\/li\u003e\n\u003cli\u003eGTFRCN \/ GTFRCP thermostat \/ modulating remote with fan control (millivolt)\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI models)\u003c\/li\u003e\n\u003cli\u003eZDVSSLR vinyl siding shield\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/451-MAN19-3.pdf\"\u003eFDV451 installation and operating manual (451-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/12\/21382-KM-B087-FDV451ENG-Dec2025-FNL1-Web.pdf\"\u003eFDV451 brochure and specifications (Dec 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (FDV451 installation and operating manual (451-MAN19), safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.2–8)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eMobile home approved (direct vent only; not when converted to B-vent); approved for bedrooms and bed-sitting rooms.\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eLocation, clearances and floor (pp.9–10)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eClearances: front 36\", sides 15-1\/2\", back 2-1\/2\"; ceiling 71-1\/2\" from the floor; top of a 90° elbow 2\"; horizontal pipe top 1\"; vertical vent 1\" (p.9).\u003c\/li\u003e\n\u003cli\u003eAlcove: at least 48\" deep, 71-1\/2\" high and 58\" wide (p.9).\u003c\/li\u003e\n\u003cli\u003eInstall on a hard, stable surface; carpet and tile are fine, a hearth is recommended over vinyl.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAccessories, liners and logs (pp.11–23)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eF45FK fan: variable speed control, needs a grounded 120 VAC receptacle.\u003c\/li\u003e\n\u003cli\u003eLog set: LOGF451 oak log set (or bronze glass \/ cannonballs with the media kit); follow the placement diagram and keep the pilot clear.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm Robax or coated Neoceram; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas, maintenance and conversion (pp.38–44)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.10).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.10).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.10).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.10). Field conversion between natural gas and propane uses Kingsman kits 450DV-CKNG \/ -CKLP (millivolt) and -CKNGI \/ -CKNG2 \/ -CKLPI \/ -CKLP2 (IPI), installed by a qualified agency (pp.41–43).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and ignition (pp.24–25, 36–37, 45–59)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.24–25, 36–37, 45–59).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.60–70)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVenting: Direct vent, 4\"\/7\" flue collar. Rigid DuraVent DirectVent Pro 4\" x 6-5\/8\" pipe with the Kingsman ZDVDKA stove adapter (horizontal or vertical termination); optional 4\" B-vent with F35BVC.\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 4-1\/2 ft (stove 2-1\/2\" from the wall); maximum vertical 45 ft; maximum horizontal 20 ft with one 90° elbow and 7 ft of vertical; 1\/4\" rise per 12\" of run.\u003c\/li\u003e\n\u003cli\u003eEach extra 90° elbow takes 36\" off the horizontal run and each 45° takes 18\"; propane horizontal runs need 1 ft more vertical rise.\u003c\/li\u003e\n\u003cli\u003eB-vent conversion with F35BVC into an existing 4\" B-vent or lined chimney, 12–60 ft.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.8).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.7).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (FDV451 installation and operating manual (451-MAN19), p.76).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — FDV451\u003c\/h3\u003e\n\u003ch4\u003eWhat do I need to order to complete the FDV451?\u003c\/h4\u003e\u003cp\u003eKingsman lists the door front, side doors and log set as required for each unit: the F450FBL charcoal door front (with safety screen and vent lid), F451SDSBL side doors, and the LOGF451 log set (or bronze glass media in its place). You also need the venting, or the F35BVC B-vent converter, and a 3\/8\" NPT gas supply.\u003c\/p\u003e\n\u003ch4\u003eDoes the FDV451 need framing or a hearth?\u003c\/h4\u003e\u003cp\u003eNo framing is needed; it is a freestanding stove. Clearances are 36\" in front, 15-1\/2\" at the sides and 2-1\/2\" at the back, with the ceiling at least 71-1\/2\" above the floor. In an alcove the space must be 48\" deep, 71-1\/2\" high and 58\" wide. It can sit directly on carpet, tile or other combustible flooring; a hearth is recommended over vinyl.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt is direct vent from a 4\"\/7\" collar to an FDVHSQ or FDVHT horizontal, Z47ST24 \/ Z47ST36 snorkel, or FDVVT40 \/ Z47VT vertical termination. The vertical rise can be up to 45 ft, and the horizontal run up to 20 ft with one 90° elbow and 7 ft of vertical; the shortest setup is 4-1\/2 ft vertical with the stove 2-1\/2\" from the wall. Each extra 90° elbow takes 36\" off the horizontal run.\u003c\/p\u003e\n\u003ch4\u003eCan it vent into an existing chimney or B-vent?\u003c\/h4\u003e\u003cp\u003eYes, with the F35BVC B-vent converter, installed vertically: 12 ft minimum to 60 ft maximum, with at least 57-1\/4\" to the top of the elbow. A masonry clay-lined chimney needs a liner if it is wider than 5\" inside, and a wood-burning or B-vent chimney if wider than 6\". The chimney must not vent any other appliance, and only the direct vent version is mobile home approved.\u003c\/p\u003e\n\u003ch4\u003eCan the FDV451 be converted between natural gas and propane?\u003c\/h4\u003e\u003cp\u003eYes, with Kingsman kits 450DV-CKNG \/ -CKLP (millivolt) or -CKNGI \/ -CKNG2 \/ -CKLPI \/ -CKLP2 (IPI), installed by a qualified agency. Input is 34,500 \/ 23,750 BTU\/h on natural gas and 31,000 \/ 24,500 BTU\/h on propane (max\/min).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in an outage; the optional fan does not run on battery.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912046809250,"sku":"FDV451N","price":2621.48,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912046842018,"sku":"FDV451LP","price":2716.88,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI Proflame 2 with Remote","offer_id":50912046874786,"sku":"FDV451NE2","price":4105.5,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI Proflame 2 with Remote","offer_id":50912046907554,"sku":"FDV451LPE2","price":4203.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/FDV451-1.jpg?v=1795037981","url":"https:\/\/unitedfireplaces.com\/products\/kingsman-fdv451-direct-vent-gas-stove-fdv451","provider":"United Fireplaces","version":"1.0","type":"link"}