{"product_id":"kingsman-fdv350-bay-direct-vent-gas-stove-fdv350","title":"Kingsman FDV350 Bay Direct Vent Gas Stove FDV350","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman FDV350 Bay is a freestanding direct vent gas stove with a bay-window front: heat-radiating ceramic glass on three sides gives a panoramic view of the fire from across the room. It brings a traditional stove look to living rooms, cottages, basements and additions with no chimney, and it is approved for bedrooms, bed-sitting rooms and (as a direct vent stove) mobile homes.\u003c\/p\u003e\u003cp\u003eA dual burner lights a realistic fire on the LOGF35 fibre split oak log set with embers, under a black louver. The front is completed with the F35DB black door frame and ceramic glass, and the optional F35RL brick liner adds a masonry look inside.\u003c\/p\u003e\u003cp\u003eInput is 37,000 BTU\/h on natural gas and 35,000 BTU\/h on propane, with Hi\/Lo flame and heat adjustment and a fireplace efficiency of up to 67.9% (NG) and 70.10% (LP). A millivolt valve needs no house power and IPI ignition has battery backup, so it keeps heating in a power outage; E2 models include a Proflame 2 remote. It vents through the wall or roof from a 4\"\/7\" collar, or into an existing chimney or B-vent with the F35BVC converter.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFreestanding direct vent stove\u003c\/strong\u003e: sealed combustion; outside air for the fire.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMillivolt or IPI valve\u003c\/strong\u003e: operates during a power failure with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (E2 models)\u003c\/strong\u003e: flame, fan, thermostat and smart thermostat control, with battery backup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual burner\u003c\/strong\u003e: with a realistic flame pattern.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-radiating ceramic glass\u003c\/strong\u003e: Robax or coated Neoceram, 5 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLog set\u003c\/strong\u003e: LOGF35 Fibre Split Oak log set with ember chunks (ordered separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: F350CSS black-frame safety screen, listed as required for each unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 37,000 \/ 29,000 BTU\/h natural gas; 35,000 \/ 27,000 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 66.63% MV \/ 67.9% IPI (NG); 67.64% \/ 70.10% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: mobile home approved (direct vent only); bedroom and bed-sitting room approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: F45FK heat activated with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall thermostat (optional)\u003c\/strong\u003e: Z2MT millivolt or Z80PT programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional, millivolt)\u003c\/strong\u003e: on\/off, thermostatic, thermostatic modulating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefractory brick liner (optional)\u003c\/strong\u003e: F35RL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlack door frame with ceramic glass (required, sold separately)\u003c\/strong\u003e: F35DB completes the stove front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB-vent adapter (optional)\u003c\/strong\u003e: F35BVC converts the stove to an existing 4\" B-vent or lined chimney.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: kits 350DV-CKLP \/ -CKNG (millivolt) and 350DV-CKLPI \/ -CKNGI \/ -CKLPI2 \/ -CKNGI2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eFDV350N \/ FDV350LP (millivolt); FDV350NE2 \/ FDV350LPE2 (IPI Proflame 2 with remote)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eFreestanding direct vent gas stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eNone required (freestanding). Alcove installation: at least 30\" deep, 55-1\/2\" high and 52-1\/2\" wide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer (ceramic glass on three sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eFront 36\"; sides 12\"; back 3\"; corner (45°) 3\"; top of a 90° elbow 4\"; top of horizontal pipe 2-1\/2\"; vertical venting 1\"; all other existing pipes 1\". Floor: may sit directly on carpet, tile or other combustible flooring; a hearth is recommended over luxury vinyl flooring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e37,000 \/ 29,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e35,000 \/ 27,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e66.63% MV \/ 67.9% IPI (NG); 67.64% \/ 70.10% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic, 5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eDirect vent, 4\"\/7\" flue collar. Rigid DuraVent DirectVent Pro 4\" x 6-5\/8\" pipe with the Kingsman ZDVDKA stove adapter (horizontal or vertical termination); optional 4\" B-vent with F35BVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eMillivolt or IPI Proflame 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eStove with dual burner and black louver, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eEmber chunks\u003c\/li\u003e\n\u003cli\u003eProflame 2 remote (FDV350NE2 \/ FDV350LPE2 only)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLOGF35 fibre split oak log set with embers (required for each unit)\u003c\/li\u003e\n\u003cli\u003eF35DB door frame and ceramic glass, black (required for each unit)\u003c\/li\u003e\n\u003cli\u003eF350CSS safety screen, black frame (listed by Kingsman as required for each unit)\u003c\/li\u003e\n\u003cli\u003eDirect vent pipe from the 4\"\/7\" collar: Kingsman (Z-Flex) venting components labelled for this stove, or DuraVent DirectVent Pro 4\" x 6-5\/8\" rigid pipe; BDM Pro Form, Ameri-Vent, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp direct vent systems are also approved\u003c\/li\u003e\n\u003cli\u003eZDVDKA DuraVent hard-pipe stove adapter (required with rigid DuraVent pipe)\u003c\/li\u003e\n\u003cli\u003eOne termination: FDVHSQ or FDVHT horizontal, FDVVT40 vertical, or Z47ST24 \/ Z47ST36 snorkel\u003c\/li\u003e\n\u003cli\u003eVertical installs: ZDVFS firestop spacer (required through floors and ceilings), ZDVAIS attic insulation shield and ZDV7SC storm collar\u003c\/li\u003e\n\u003cli\u003eOr, instead of direct vent pipe: F35BVC B-vent converter into an existing 4\" B-vent or lined chimney, 12 ft minimum to 60 ft maximum (not allowed in mobile homes)\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan or IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eF35RL refractory brick liner\u003c\/li\u003e\n\u003cli\u003eF45FK fan kit with variable speed control (millivolt \/ Proflame 1 models)\u003c\/li\u003e\n\u003cli\u003eF45FK2 fan kit (Proflame 2 models)\u003c\/li\u003e\n\u003cli\u003eF7DBC decorative black collar, 7\"\u003c\/li\u003e\n\u003cli\u003eF7DTP decorative black wall trim plate\u003c\/li\u003e\n\u003cli\u003eZ2MT millivolt wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable digital millivolt wall thermostat\u003c\/li\u003e\n\u003cli\u003eGFRC on\/off remote (millivolt \/ IPI)\u003c\/li\u003e\n\u003cli\u003eGTRC thermostat remote (millivolt)\u003c\/li\u003e\n\u003cli\u003eGTMRCN thermostat \/ modulating remote, natural gas (millivolt)\u003c\/li\u003e\n\u003cli\u003eGTMRCP thermostat \/ modulating remote, propane (millivolt)\u003c\/li\u003e\n\u003cli\u003eGTFRCN \/ GTFRCP thermostat \/ modulating remote with fan control (millivolt)\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI models)\u003c\/li\u003e\n\u003cli\u003eZDVSSLR vinyl siding shield\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2024\/01\/350-MAN19.pdf\"\u003eFDV350 installation and operating manual (350-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2023\/08\/18595-KM-B030-FDV350ENG-Aug2023-WEB2.pdf\"\u003eFDV350 brochure and specifications (Aug 2023)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (FDV350 installation and operating manual (350-MAN19), safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.1–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eMobile home approved (direct vent only; not when converted to B-vent); approved for bedrooms and bed-sitting rooms.\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eLocation, clearances and floor (pp.10)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eClearances: front 36\", sides 12\", back 3\"; corner (45°) 3\"; top of a 90° elbow 4\"; horizontal pipe top 2-1\/2\" (p.10).\u003c\/li\u003e\n\u003cli\u003eAlcove: at least 30\" deep, 55-1\/2\" high and 52-1\/2\" wide (p.10).\u003c\/li\u003e\n\u003cli\u003eInstall on a hard, stable surface; carpet and tile are fine, a hearth is recommended over vinyl.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAccessories, liners and logs (pp.11–15)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eF45FK fan: variable speed control, needs a grounded 120 VAC receptacle.\u003c\/li\u003e\n\u003cli\u003eLog set: LOGF35 Fibre Split Oak log set with ember chunks (ordered separately); follow the placement diagram and keep the pilot clear.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm Robax or coated Neoceram; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas, maintenance and conversion (pp.16–19)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.16).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.16).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.16).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.16). Field conversion between natural gas and propane uses Kingsman kits 350DV-CKLP \/ -CKNG (millivolt) and 350DV-CKLPI \/ -CKNGI \/ -CKLPI2 \/ -CKNGI2 (IPI) (p.17), installed by a qualified agency (pp.17–19).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and ignition (pp.20–39)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.20–39).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.40–49)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVenting: Direct vent, 4\"\/7\" flue collar. Rigid DuraVent DirectVent Pro 4\" x 6-5\/8\" pipe with the Kingsman ZDVDKA stove adapter (horizontal or vertical termination); optional 4\" B-vent with F35BVC.\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 4-1\/2 ft (stove 4\" from the wall); maximum vertical 40 ft; maximum horizontal 20 ft with one 90° elbow and 7 ft of vertical; 1\/4\" rise per 12\" of run.\u003c\/li\u003e\n\u003cli\u003eEach extra 90° elbow takes 36\" off the horizontal run and each 45° takes 18\"; propane horizontal runs need 1 ft more vertical rise.\u003c\/li\u003e\n\u003cli\u003eB-vent conversion with F35BVC into an existing 4\" B-vent or lined chimney, 12–60 ft.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.8).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.7).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (FDV350 installation and operating manual (350-MAN19), p.53).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — FDV350\u003c\/h3\u003e\n\u003ch4\u003eWhat do I need to order to complete the FDV350?\u003c\/h4\u003e\u003cp\u003eKingsman lists three parts as required for each unit: the LOGF35 fibre split oak log set with embers, the F35DB black door frame with ceramic glass, and the F350CSS black-frame safety screen. You also need the venting (or the F35BVC B-vent converter) and a 3\/8\" NPT gas supply.\u003c\/p\u003e\n\u003ch4\u003eDoes the FDV350 need framing or a hearth?\u003c\/h4\u003e\u003cp\u003eNo framing is needed; it is a freestanding stove. In an alcove the space must be at least 30\" deep, 55-1\/2\" high and 52-1\/2\" wide. It can sit directly on carpet, tile or other combustible flooring; a hearth is recommended over luxury vinyl. Clearances are 36\" in front, 12\" at the sides, 3\" at the back and 3\" in a 45° corner.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt is direct vent from a 4\"\/7\" collar to an FDVHSQ or FDVHT horizontal, FDVVT40 vertical, or Z47ST24 \/ Z47ST36 snorkel termination. The vertical rise can be up to 40 ft, and the horizontal run up to 20 ft with one 90° elbow and 7 ft of vertical; the shortest setup is 4-1\/2 ft vertical with the stove 4\" from the wall. Each extra 90° elbow takes 36\" off the horizontal run.\u003c\/p\u003e\n\u003ch4\u003eCan it vent into an existing chimney or B-vent?\u003c\/h4\u003e\u003cp\u003eYes, with the F35BVC B-vent converter: 12 ft minimum to 60 ft maximum, with at least 57-1\/4\" to the top of the elbow. A masonry clay-lined chimney needs a liner if it is wider than 5\" inside, and a wood-burning or B-vent chimney if wider than 6\". A stove converted to B-vent cannot be installed in a mobile home.\u003c\/p\u003e\n\u003ch4\u003eCan the FDV350 be converted between natural gas and propane?\u003c\/h4\u003e\u003cp\u003eYes, with Kingsman kits 350DV-CKLP \/ -CKNG (millivolt) or 350DV-CKLPI \/ -CKNGI \/ -CKLPI2 \/ -CKNGI2 (IPI), installed by a qualified agency. Input is 37,000 \/ 29,000 BTU\/h on natural gas and 35,000 \/ 27,000 BTU\/h on propane (max\/min).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in an outage; the optional fan does not run on battery.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912046678178,"sku":"FDV350N","price":2741.03,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912046710946,"sku":"FDV350LP","price":2837.63,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI Proflame 2 with Remote","offer_id":50912046743714,"sku":"FDV350NE2","price":4231.08,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI Proflame 2 with Remote","offer_id":50912046776482,"sku":"FDV350LPE2","price":4328.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/kingsman-fdv350-front.jpg?v=1795271565","url":"https:\/\/unitedfireplaces.com\/products\/kingsman-fdv350-bay-direct-vent-gas-stove-fdv350","provider":"United Fireplaces","version":"1.0","type":"link"}