{"product_id":"infratech-w33-flush-mount-frame-18-2295-color","title":"Infratech W33 Flush Mount Frame 18-2295","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eAn Infratech flush mount frame recesses a W or WD-Series heater into the ceiling so the heater sits flush, with only a trim edge showing. It is the part Infratech specifies for recessed installations in drywall, plaster, stucco or wood ceilings, and it replaces the swivel brackets supplied with the heater. Each frame fits one heater length; choose the finish with the Color option.\u003c\/p\u003e\u003cp\u003eThe flush mount frame whip detail shows a factory-supplied 4 ft high-temperature whip for the junction-box connection; longer whips (10 to 75 ft) are sold separately.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRecessed, flush appearance for W and WD-Series heaters\u003c\/li\u003e\n\u003cli\u003eStainless steel standard; black, white and bronze (+$60); Marine-Grade 316 stainless (+$250) where offered\u003c\/li\u003e\n\u003cli\u003eConnections made in a junction box with a high-temperature whip\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003cth\u003eShip wt\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eW33\u003c\/td\u003e\n\u003ctd\u003e18-2295\u003c\/td\u003e\n\u003ctd\u003e33 in. W and WD heaters\u003c\/td\u003e\n\u003ctd\u003e18 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eW39\u003c\/td\u003e\n\u003ctd\u003e18-2300\u003c\/td\u003e\n\u003ctd\u003e39 in. W and WD heaters\u003c\/td\u003e\n\u003ctd\u003e18 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eW48\u003c\/td\u003e\n\u003ctd\u003e18-2302\u003c\/td\u003e\n\u003ctd\u003e48 in. W and WD heaters\u003c\/td\u003e\n\u003ctd\u003e22 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eW61\u003c\/td\u003e\n\u003ctd\u003e18-2305\u003c\/td\u003e\n\u003ctd\u003e61-1\/4 in. W and WD heaters\u003c\/td\u003e\n\u003ctd\u003e24 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e Flush mount frame.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRequired:\u003c\/strong\u003e A W or WD-Series heater of the matching length; framing\/rough opening per the frame drawing; installation by a licensed electrician.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOptional:\u003c\/strong\u003e Longer high-temperature whips (10-75 ft).\u003c\/p\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.infratech.com\/wp-content\/uploads\/2026\/10\/IN_18-2295-W-33-FLUSH-MOUNT-FRAME_2022-1.pdf\"\u003eW-33 Flush Mount Frame Drawing (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.infratech.com\/wp-content\/uploads\/2026\/10\/IN_18-2300-W-39-FLUSH-MOUNT-FRAME_2022.pdf\"\u003eW-39 Flush Mount Frame Drawing (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.infratech.com\/wp-content\/uploads\/2026\/10\/18-2302-48-Flush-Mount-trim-Kit-Aug.-1-2024.pdf\"\u003eW-48 Flush Mount Frame Drawing (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.infratech.com\/wp-content\/uploads\/2026\/10\/IN_18-2305-W-61-FLUSH-MOUNT-FRAME_2022.pdf\"\u003eW-61 Flush Mount Frame Drawing (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.infratech.com\/wp-content\/uploads\/2026\/10\/IN_FMF-WHIP-Detail_2022.pdf\"\u003eFlush Mount High-Temperature Whip Detail (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.infratech.com\/wp-content\/uploads\/2026\/10\/IN038_W-series_instructions_prod_jul24.pdf\"\u003eW \u0026amp; WD-Series Application\/Installation Guide (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003eInstall following Infratech's instructions and keep all heater clearances to combustibles listed in the heater installation guide. Heater wiring must be completed by a licensed electrician. Follow the manufacturer's instructions exactly; improper installation can cause fire, damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCalifornia Proposition 65 warning:\u003c\/strong\u003e This product can expose you to chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e","brand":"Infratech","offers":[{"title":"Stainless Steel","offer_id":50912404078754,"sku":"18-2295-SS","price":556.0,"currency_code":"USD","in_stock":true},{"title":"Black","offer_id":50912404111522,"sku":"18-2295-BLK","price":616.0,"currency_code":"USD","in_stock":true},{"title":"Bronze","offer_id":50912404144290,"sku":"18-2295-BR","price":616.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/infratech-18-2295-SS.png?v=1793399250","url":"https:\/\/unitedfireplaces.com\/products\/infratech-w33-flush-mount-frame-18-2295-color","provider":"United Fireplaces","version":"1.0","type":"link"}