{"product_id":"infratech-30-4064","title":"Infratech Home Management Relay Panel, 4 Relay 30-4064","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Infratech Home Management relay panel connects Infratech heaters to a whole-home automation system. It accepts a 0-10 V DC control signal from systems such as Lutron, Crestron and Control4, so heaters can be scheduled, dimmed and grouped with lighting and other scenes. Each relay controls a heating zone.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e0-10 V DC input from home automation systems\u003c\/li\u003e\n\u003cli\u003eMultiple heating zones\u003c\/li\u003e\n\u003cli\u003eUL 508 listed, made in the USA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRelays\u003c\/th\u003e\n\u003ctd\u003e1 to 6 relays (larger panels by special order)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eNEMA 4\/12 with custom aluminum heat sink, terminal block and UL 489 breakers, pre-assembled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListing\u003c\/th\u003e\n\u003ctd\u003eUL 508 control panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBuilt\u003c\/th\u003e\n\u003ctd\u003eProject specific - provide the voltage and wiring requirements with the order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl input\u003c\/th\u003e\n\u003ctd\u003eRequires a 0-10 V DC signal from the home management system (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e31-40 lb by relay count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003cth\u003eRelays\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e30-4061\u003c\/td\u003e\n\u003ctd\u003e1 relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30-4062\u003c\/td\u003e\n\u003ctd\u003e2 relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30-4063\u003c\/td\u003e\n\u003ctd\u003e3 relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30-4064\u003c\/td\u003e\n\u003ctd\u003e4 relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30-4065\u003c\/td\u003e\n\u003ctd\u003e5 relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30-4066\u003c\/td\u003e\n\u003ctd\u003e6 relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eRequired:\u003c\/strong\u003e A home automation system that provides a 0-10 V DC signal; installation by a licensed electrician.\u003c\/p\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.infratech.com\/wp-content\/uploads\/2026\/10\/IN_controlssheets_homemanagement_2022.pdf\"\u003eHome Management Systems Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.infratech.com\/wp-content\/uploads\/2026\/10\/30-4062-2-RELAY-HOME-MANAGEMENT-PANEL-44-44-SAMPLE.pdf\"\u003eHome Management Sample Panel Wiring Diagram (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.infratech.com\/wp-content\/uploads\/2026\/10\/Home-Management-Relay-Panel-Placement-REV.A-05132024.pdf\"\u003eHome Management Panel Clearance Requirements (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.infratech.com\/wp-content\/uploads\/2026\/10\/IN037_Controls_dimensions_relaypanel_072823_dj.pdf\"\u003eRelay Panel Dimensions (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003eInfratech controls and accessories must be installed by a licensed electrician following Infratech's instructions and wiring diagrams, the National Electrical Code and local codes. Disconnect power before service. Non-Infratech controls or accessories may void the heater warranty. Follow the manufacturer's instructions exactly; improper installation can cause fire, damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCalifornia Proposition 65 warning:\u003c\/strong\u003e This product can expose you to chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e","brand":"Infratech","offers":[{"title":"Default Title","offer_id":50771273056418,"sku":"30-4064","price":4971.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/infratech-30-4061-product.png?v=1793459428","url":"https:\/\/unitedfireplaces.com\/products\/infratech-30-4064","provider":"United Fireplaces","version":"1.0","type":"link"}