{"product_id":"buck-stove-model-zcbb-36-vent-free-gas-firebox-with-mantel-nv-zcbbxl-o","title":"Buck Stove ZCBBXL 36\" Vent-Free Firebox \u0026 Logs NV ZCBBXL-O","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Buck Stove ZCBBXL 36\" is a zero-clearance vent-free firebox that lets you add a real gas fireplace almost anywhere: it needs no chimney and no hearth, and it frames into a standard wood wall cavity in new construction or a remodel.\u003c\/p\u003e\u003cp\u003eFinish the black face with tile, stone, brick or marble, raise it on a platform for a raised hearth, or use Buck's flush-mount or wooden surround kits. The design circulates warm air out of the top grille instead of losing it up a chimney.\u003c\/p\u003e\u003cp\u003eThe XL package comes complete: Buck's EmberVision 100 oak vent-free gas logs (40,000 BTU\/hr, 24\"), an on\/off remote and the blower assembly are included (Buck 2026 sheet), so it is ready to heat with a millivolt valve, piezo ignition and ODS safety pilot.\u003c\/p\u003e\u003cp\u003eVent-free logs are about 99.9% efficient and need no electricity to burn, which makes the ZCBBXL a dependable source of heat during power outages. Natural gas or propane. Approved for aftermarket manufactured homes. Made by Buck Stove.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmberVision 100 oak gas logs\u003c\/strong\u003e included (24\", 40,000 BTU\/hr max).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn\/off remote included\u003c\/strong\u003e; thermostatic remotes optional.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower assembly included\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero clearance\u003c\/strong\u003e: frames into a wood wall cavity, no chimney or hearth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMillivolt valve\u003c\/strong\u003e, piezo ignition, ODS pilot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorks in power outages\u003c\/strong\u003e (burner needs no electricity).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinish with non-combustible facing\u003c\/strong\u003e or Buck surround kits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNatural gas or propane\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAftermarket manufactured-home approved\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirebox listed to ANSI Z21.91-2017\u003c\/strong\u003e; logs to ANSI Z21.11.2.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eNV ZCBBXL-ONAT \/ NV ZCBBXL-OLP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e39-5\/16\" W x 35-1\/2\" H x 19-1\/2\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum framing\u003c\/th\u003e\n\u003ctd\u003e40-7\/8\" W x 38-1\/8\" H x 20-1\/4\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLog set\u003c\/th\u003e\n\u003ctd\u003eEmberVision 100 oak, 24\", 31,000-40,000 BTU\/hr (EV manual p.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eValve\u003c\/th\u003e\n\u003ctd\u003eSIT 820 millivolt with ODS pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRemote\u003c\/th\u003e\n\u003ctd\u003eOn\/off included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBlower\u003c\/th\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox listing\u003c\/th\u003e\n\u003ctd\u003eANSI Z21.91-2017, max 40,000 BTU\/hr heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZCBB 36\" zero-clearance vent-free firebox\u003c\/li\u003e\n\u003cli\u003eEmberVision 100 oak gas log set and burner (24\")\u003c\/li\u003e\n\u003cli\u003eOn\/off remote\u003c\/li\u003e\n\u003cli\u003eBlower assembly\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired (sold separately)\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGas supply line of the fuel ordered with shutoff valve\u003c\/li\u003e\n\u003cli\u003ePropane: external regulator limiting tank pressure to 13\" W.C.\u003c\/li\u003e\n\u003cli\u003eElectrical receptacle wired into the framing for the blower (NFPA 70)\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing materials\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePO FDC504-S SkyTech thermostatic remote, dark gray (millivolt)\u003c\/li\u003e\n\u003cli\u003ePO FDC504-A Acumen thermostatic remote, black (millivolt)\u003c\/li\u003e\n\u003cli\u003ePE 400142 white wall thermostat (millivolt)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFirebox: two years from first purchase, parts only, original purchaser (ZCBB manual p.20).\u003c\/li\u003e\n\u003cli\u003eLogs and burner: two years from first purchase on materials and components (EmberVision manual pp.32-33).\u003c\/li\u003e\n\u003cli\u003eImplied warranties limited to one year; not covered: labor, transportation, service calls, painted surfaces, improper installation.\u003c\/li\u003e\n\u003cli\u003eMail registrations within 30 days of installation.\u003c\/li\u003e\n\u003cli\u003eSources: Buck ZCBB manual (Nov 2018) p.20; EmberVision manual (Nov 2019) pp.32-33.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/buckstove.com\/wp-content\/uploads\/2024\/10\/ZCBB-Manual-November-2018.pdf\"\u003eZCBB 36\" firebox installation manual (November 2018)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/buckstove.com\/wp-content\/uploads\/2024\/10\/EmberVision-Manual-November-2019.pdf\"\u003eEmberVision 100\/200 gas log manual (November 2019)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e Improper installation, adjustment, alteration, service or maintenance can cause fire, explosion, property damage, injury or carbon-monoxide poisoning. This vent-free gas appliance must be installed and serviced by a qualified professional following the manufacturer's manual and your local codes. If you ever smell gas, do not light anything or touch electrical switches; leave and call your gas supplier.\u003c\/p\u003e\u003ch4\u003eSafety (manual p.3)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDo not build a wood fire; do not modify or replace the factory canopy.\u003c\/li\u003e\n\u003cli\u003eKeep combustibles away; no unapproved blowers or heat exchangers.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDimensions and clearances (manual pp.6-9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e7\" from the opening to adjacent combustible side walls; 42\" from top of opening to ceiling; 24\" clear in front.\u003c\/li\u003e\n\u003cli\u003eMantel above the opening: 14\" for mantels 6\"-10\" deep, 16\" for 12\" deep.\u003c\/li\u003e\n\u003cli\u003eDo not cover or touch the black painted top or block the air outlets; only the header may rest on the top standoffs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinishing (manual p.8)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNon-combustible facings (marble, brick, tile) may overlap the black face; combustible coverings may not.\u003c\/li\u003e\n\u003cli\u003eBrick or stone needs an L-shaped steel lintel across the top.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMantels and surrounds (manual pp.9-12)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eFlush mount kit PA KDMZCBBFF or wooden surround PA KDMZCBB.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eRoom size and fresh air (manual pp.13-16)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eThe room must be an unconfined space: at least 50 cubic feet per 1,000 BTU\/hr of all gas appliances in the space (some areas require 70).\u003c\/li\u003e\n\u003cli\u003eExample from the manual: a 20 x 16 x 8 ft room (2,560 cu. ft.) supports up to 51,200 BTU\/hr.\u003c\/li\u003e\n\u003cli\u003eIn tighter spaces, add two permanent openings to an adjoining room or outdoors (one within 12\" of the ceiling, one within 12\" of the floor, each at least 1 sq. in. per 1,000 BTU\/hr and 100 sq. in. minimum).\u003c\/li\u003e\n\u003cli\u003eVent-free heaters add moisture to the room; poor ventilation can cause mildew.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBlower and wiring (manual pp.17-18)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eMA ZCBB714 needs a receptacle wired during framing; ground per the NEC.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eGas logs (EmberVision manual)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eLog input 31,000-40,000 BTU\/hr; NG inlet 4.5-10.5\" W.C., LP 10.5-13.0\" W.C.\u003c\/li\u003e\n\u003cli\u003ePlace logs and rock-wool embers exactly per the diagram; not for bedrooms or bathrooms.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local building codes; where none apply, the \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e (manual pp.3, 12, 16).\u003c\/li\u003e\n\u003cli\u003eElectrical: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e (manual pp.5, 18).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eInstall and operate this appliance exactly as the manufacturer's instructions and local codes require. Improper installation, adjustment or maintenance can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide and benzene, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.p65warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e","brand":"Buck Stoves","offers":[{"title":"Natural Gas","offer_id":50681050431650,"sku":"NV ZCBBXL-ONAT","price":2804.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50681050464418,"sku":"NV ZCBBXL-OLP","price":2804.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/model-zcbb-black.png?v=1795104190","url":"https:\/\/unitedfireplaces.com\/products\/buck-stove-model-zcbb-36-vent-free-gas-firebox-with-mantel-nv-zcbbxl-o","provider":"United Fireplaces","version":"1.0","type":"link"}