{"product_id":"buck-stove-model-1127-vent-free-gas-stove-nv-11272","title":"Buck Stove Model 1127 Vent-Free Gas Heater NV C11272","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Buck Stove Model 1127 is a slim vent-free gas heater that delivers up to 25,000 BTU\/hr of quiet, steady heat for pennies an hour. At just 7 inches deep it hangs flat on the wall like a radiant panel, stands on the optional pedestal, or sits inside one of Buck's wood mantels for a traditional fireplace look.\u003c\/p\u003e\u003cp\u003eIt suits kitchens, living rooms, basements, workshops and additions that need reliable zone heat without a chimney or vent pipe. Because it is rated over 10,000 BTU\/hr, the 1127 is not for bedrooms or bathrooms.\u003c\/p\u003e\u003cp\u003eA factory-installed variable-speed blower circulates the warm air, and a manual rotary thermostat (Maxitrol modulating valve on the 1110) holds the room temperature. Ignition is a matchless piezo button and an oxygen depletion sensor (ODS) pilot shuts the burner off if fresh air runs low. Because the valve needs no electricity, the burner keeps heating during a power outage.\u003c\/p\u003e\u003cp\u003eThe Model 1127 is identical in size and shape to the Model 1110; choose the 1110 for smaller rooms and bedrooms, the 1127 for larger living areas. Each is built for one fuel, natural gas or propane, and is approved for aftermarket manufactured homes. Made by Buck Stove.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 25,000 BTU\/hr\u003c\/strong\u003e heat output (Buck rating), about 99.9% efficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVent-free\u003c\/strong\u003e: no chimney or vent needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory-installed variable-speed blower\u003c\/strong\u003e (120V).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual rotary thermostat\u003c\/strong\u003e (not remote compatible).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePiezo matchless ignition\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen depletion sensor (ODS) pilot\u003c\/strong\u003e safety shutoff (manual p.7).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree ways to install\u003c\/strong\u003e: wall mount, P12 pedestal or Buck mantel (not for use in a fireplace).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnly 7\" deep\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNatural gas or propane\u003c\/strong\u003e models (not field convertible).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAftermarket manufactured-home approved\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed to ANSI Z21.11.2\u003c\/strong\u003e unvented room heater standard (manual p.4).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eNV C11272NAT (natural gas), NV C11272LP (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat output\u003c\/th\u003e\n\u003ctd\u003eup to 25,000 BTU\/hr (manual technical data lists 11,000-27,000 BTU\/hr input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e20-1\/8\" H x 22\" W x 7\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight on P12 pedestal\u003c\/th\u003e\n\u003ctd\u003e27-1\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproximate weight\u003c\/th\u003e\n\u003ctd\u003e47 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet pressure\u003c\/th\u003e\n\u003ctd\u003eNG 5.0-10.5\" W.C.; LP 11-13\" W.C. (manual p.20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT, left side (right side possible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBlower\u003c\/th\u003e\n\u003ctd\u003e120V, 60 Hz, 0.54 A, grounded plug (manual p.33)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances\u003c\/th\u003e\n\u003ctd\u003e42\" top to ceiling, 5\" sides to walls, 7\" bottom to floor (manual p.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e99.9% (Buck)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eANSI Z21.11.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eModel 1127 vent-free heater\u003c\/li\u003e\n\u003cli\u003eFactory-installed blower\u003c\/li\u003e\n\u003cli\u003eManual rotary thermostat\u003c\/li\u003e\n\u003cli\u003eWall-mount hardware per manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired (sold separately)\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGas supply line of the fuel ordered, with an accessible shutoff valve and sediment trap\u003c\/li\u003e\n\u003cli\u003ePropane: external regulator limiting tank pressure to 13\" W.C. (manual pp.17-18)\u003c\/li\u003e\n\u003cli\u003eGrounded 120V outlet for the blower\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFA P12 pedestal (19\" W x 7\" H x 9-3\/4\" D, black)\u003c\/li\u003e\n\u003cli\u003ePA KDM1127 Deluxe mantel (37\" L x 14\" W x 34\" H; unfinished, light oak, dark oak or black)\u003c\/li\u003e\n\u003cli\u003ePA KDMC1127 Corner mantel (unfinished, light oak, dark oak or black)\u003c\/li\u003e\n\u003cli\u003ePA KDM1127PRES Prestige bookcase mantel (50-3\/4\" W x 36\" H x 13\" D)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTwo years from first purchase, parts only (manual p.45).\u003c\/li\u003e\n\u003cli\u003eImplied warranties limited to one year.\u003c\/li\u003e\n\u003cli\u003eNot covered: labor, transportation, service calls, painted surfaces and improper installation.\u003c\/li\u003e\n\u003cli\u003eMail the owner registration within 30 days of installation (p.46).\u003c\/li\u003e\n\u003cli\u003eSource: Buck Model 1110\/1127 manual, January 2023, page 45.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/buckstove.com\/wp-content\/uploads\/2024\/10\/1127-Manual-1-30-2023.pdf\"\u003eModels 1110 \/ 1127 installation and owner's manual (January 2023)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation and safety\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e Improper installation, adjustment, alteration, service or maintenance can cause fire, explosion, property damage, injury or carbon-monoxide poisoning. This vent-free gas appliance must be installed and serviced by a qualified professional following the manufacturer's manual and your local codes. If you ever smell gas, do not light anything or touch electrical switches; leave and call your gas supplier.\u003c\/p\u003e\u003ch4\u003eSafety information (manual pp.3-5)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNever install in a bathroom or recreational vehicle; heaters over 10,000 BTU\/hr may not go in a bedroom or bathroom (pp.3, 5).\u003c\/li\u003e\n\u003cli\u003eNever convert to another gas; keep curtains and furniture at least 24\" from the front (p.3).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide and smoke detectors (p.3).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eRoom size and fresh air (manual pp.13-16)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eThe room must be an unconfined space: at least 50 cubic feet per 1,000 BTU\/hr of all gas appliances in the space (some areas require 70).\u003c\/li\u003e\n\u003cli\u003eExample from the manual: a 20 x 16 x 8 ft room (2,560 cu. ft.) supports up to 51,200 BTU\/hr.\u003c\/li\u003e\n\u003cli\u003eIn tighter spaces, add two permanent openings to an adjoining room or outdoors (one within 12\" of the ceiling, one within 12\" of the floor, each at least 1 sq. in. per 1,000 BTU\/hr and 100 sq. in. minimum).\u003c\/li\u003e\n\u003cli\u003eVent-free heaters add moisture to the room; poor ventilation can cause mildew.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eLocation and clearances (manual p.8)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e42\" from top of heater to ceiling; 5\" from each side to adjacent walls; 7\" from bottom to carpet, tile or other combustible floor.\u003c\/li\u003e\n\u003cli\u003eIn a garage, the pilot and burner must be at least 18\" above the floor.\u003c\/li\u003e\n\u003cli\u003eKeep the front and sides clear of drafts and obstructions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMounting (manual pp.9-12)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eWall mount: template at least 7\" above the floor.\u003c\/li\u003e\n\u003cli\u003ePedestal: secure to the floor on a flat, solid surface.\u003c\/li\u003e\n\u003cli\u003eMantel: secure with the Z-brackets; not for installation inside a fireplace.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas connection (manual pp.17-20)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e3\/8\" NPT inlet; 1\/2\" or larger black iron\/steel supply pipe or code-approved tubing.\u003c\/li\u003e\n\u003cli\u003eNatural gas inlet 5.0-10.5\" W.C., manifold 3.5\"; propane inlet 11-13\" W.C., manifold 9\".\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eElectrical (manual p.33)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eBlower 120V\/60Hz, 0.54 A, three-prong grounded plug.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eOperation (manual pp.24-30)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003ePiezo ignition with ODS pilot; run the burner fully on or off, never in between.\u003c\/li\u003e\n\u003cli\u003eDo not use for cooking or burning trash.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes or, where none apply, the \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e (manual pp.3, 13, 16).\u003c\/li\u003e\n\u003cli\u003eAlso cited: the \u003ca href=\"https:\/\/www.iccsafe.org\/\"\u003eInternational Fuel Gas Code (International Code Council)\u003c\/a\u003e (p.13).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eInstall and operate this appliance exactly as the manufacturer's instructions and local codes require. Improper installation, adjustment or maintenance can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide and benzene, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.p65warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e","brand":"Buck Stoves","offers":[{"title":"Propane","offer_id":50681050497186,"sku":"NV C11272LP","price":1125.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas","offer_id":50681050529954,"sku":"NV C11272NAT","price":1125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/buck-1110-1127-official-heater_d6e4c877-967d-4516-ba25-79bbb2579c7b.png?v=1792871347","url":"https:\/\/unitedfireplaces.com\/products\/buck-stove-model-1127-vent-free-gas-stove-nv-11272","provider":"United Fireplaces","version":"1.0","type":"link"}