{"product_id":"buck-stove-cr-18-gas-log-set-gl-cr18m","title":"Buck Stove CR18 Vent-Free Ceramic Gas Log Set GL CR18","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Buck Stove CR18 is a 18\" vent-free ceramic gas log set that turns an existing wood-burning fireplace into a clean, efficient gas fire in an afternoon. Four realistic ceramic logs sit on Buck's vent-free burner.\u003c\/p\u003e\u003cp\u003eIt fits smaller fireplace openings where a 24\" set will not, with the same Buck burner and controls as the larger CR sets.\u003c\/p\u003e\u003cp\u003eRated up to 30,000 BTU\/hr (23,000 minimum), it puts nearly all of its heat into the room, about 99% efficient, with no chimney needed in vent-free mode. Choose a millivolt valve (remote and wall-thermostat ready) or a modulating thermostatic valve (not remote compatible). Piezo ignition lights the ODS safety pilot, and the burner needs no electricity, so it keeps heating through outages.\u003c\/p\u003e\u003cp\u003eNatural gas or propane (order the fuel you have). Approved for aftermarket manufactured homes. Add the MA 19HS heat shield with blower to push more heat into the room. Made by Buck Stove.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e18\" ceramic log set\u003c\/strong\u003e with burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 30,000 BTU\/hr\u003c\/strong\u003e (23,000 min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbout 99% efficient\u003c\/strong\u003e vent-free (Buck).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChoose a millivolt valve (remote and wall-thermostat ready) or a modulating thermostatic valve (not remote compatible)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePiezo ignition\u003c\/strong\u003e and \u003cstrong\u003eODS pilot\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi-to-Lo flame control\u003c\/strong\u003e (Buck).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMillivolt versions are remote and wall-thermostat compatible\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 19HS heat shield with blower\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorks without electricity\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNatural gas or propane\u003c\/strong\u003e (not field convertible).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAftermarket manufactured-home approved\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified to ANSI Z21.11.2 and ANSI Z21.60\/CSA 2.26\u003c\/strong\u003e (vent-free or vented decorative use).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSKUs\u003c\/th\u003e\n\u003ctd\u003eGL CR18MVNAT, GL CR18MVLP, GL CR18MODNAT, GL CR18MODLP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e23,000-30,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum fireplace\u003c\/th\u003e\n\u003ctd\u003e17\" H x 25\" W front x 18\" W rear x 14\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum with 19HS heat shield\u003c\/th\u003e\n\u003ctd\u003e20\" H x 25\" W front x 23\" W rear x 19-1\/2\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas pressures\u003c\/th\u003e\n\u003ctd\u003eNG inlet 4.5-10.5\" W.C., manifold 3.5\"; LP inlet 10.5-13.0\" W.C., manifold 10.0\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT, right side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSide wall clearance\u003c\/th\u003e\n\u003ctd\u003e8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCeiling clearance\u003c\/th\u003e\n\u003ctd\u003e42\" from top of the fireplace opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003eAbout 99% (Buck)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eANSI Z21.11.2; ANSI Z21.60\/CSA 2.26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e18\" ceramic log set\u003c\/li\u003e\n\u003cli\u003eVent-free burner with valve and ODS pilot\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired (sold separately)\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eA solid-fuel masonry fireplace, a UL 127 factory-built fireplace that allows vent-free logs, or a listed ventless firebox (e.g. Buck ZCBB)\u003c\/li\u003e\n\u003cli\u003eGas supply line with shutoff valve\u003c\/li\u003e\n\u003cli\u003ePropane: external regulator limiting tank pressure to 13\" W.C.\u003c\/li\u003e\n\u003cli\u003eFireplace screen in place during operation; glass doors fully open\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePO FDC504-S SkyTech thermostatic remote, dark gray (millivolt)\u003c\/li\u003e\n\u003cli\u003ePO FDC504-A Acumen thermostatic remote, black (millivolt)\u003c\/li\u003e\n\u003cli\u003ePO 4001-A-NBS SkyTech on\/off remote, white (millivolt)\u003c\/li\u003e\n\u003cli\u003ePE 400142 white wall thermostat (millivolt)\u003c\/li\u003e\n\u003cli\u003eMA 19HS heat shield with blower (120V)\u003c\/li\u003e\n\u003cli\u003eMAPSFPC canopy (required with some mantel heights; see manual)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTwo years from first purchase on materials and components, original purchaser, parts only.\u003c\/li\u003e\n\u003cli\u003eImplied warranties limited to one year; liability limited to purchase price.\u003c\/li\u003e\n\u003cli\u003eNot covered: labor, removal\/reinstallation, transportation, service calls, painted surfaces, improper installation.\u003c\/li\u003e\n\u003cli\u003eMail the registration within 30 days of installation with dealer and installer numbers.\u003c\/li\u003e\n\u003cli\u003eSource: CR\/DX 18-24-30 and Mountaineer gas log manual (October 2023), warranty page.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/buckstove.com\/wp-content\/uploads\/2024\/10\/18-24-30-CR-DX-Mountaineer-Manual-Oct-2023.pdf\"\u003eCR\/DX 18-24-30 and Mountaineer gas log manual (October 2023)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation and safety\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e Improper installation, adjustment, alteration, service or maintenance can cause fire, explosion, property damage, injury or carbon-monoxide poisoning. This vent-free gas appliance must be installed and serviced by a qualified professional following the manufacturer's manual and your local codes. If you ever smell gas, do not light anything or touch electrical switches; leave and call your gas supplier.\u003c\/p\u003e\u003ch4\u003eSafety information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNot for bedrooms or bathrooms (over 10,000 BTU\/hr), recreational vehicles, or drafty, high-traffic areas.\u003c\/li\u003e\n\u003cli\u003eNever burn wood in the fireplace afterwards; do not place objects on the logs.\u003c\/li\u003e\n\u003cli\u003eKeep curtains and furniture at least 42\" from the front; keep fans from blowing into the fireplace.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFireplace types and preparation\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMasonry, UL 127 factory-built (if its manual allows vent-free logs) or listed ventless firebox; clean the chimney and firebox first.\u003c\/li\u003e\n\u003cli\u003eMinimum opening: 17\" H x 25\" W front x 18\" W rear x 14\" D.\u003c\/li\u003e\n\u003cli\u003ePermanently close outside air ducts and ash dumps.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eClearances\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e8\" from the sides of the opening to combustible walls; 42\" from the top of the opening to the ceiling; nothing within 24\" of the opening.\u003c\/li\u003e\n\u003cli\u003eMantel height depends on mantel depth (manual Figure 1); a MAPSFPC canopy is required unless a 10\" mantel is 36\" above the opening.\u003c\/li\u003e\n\u003cli\u003eCarpet or tile floors need a full-width metal or wood panel.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas connection and pressures\u003c\/h4\u003e\u003cul\u003e\u003cli\u003e3\/8\" NPT on the right; natural gas needs internally tinned copper tubing; leak-test with soap solution.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eLog placement and operation\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003ePlace each log and the embers exactly per the manual; wear gloves (bonded ceramic fiber).\u003c\/li\u003e\n\u003cli\u003eRun the burner fully on or fully off; do not use the shutoff to adjust heat.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHeat shield 19HS\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eOptional 19HS blower runs on 120V\/60Hz, 0.54 A; check the larger minimum fireplace size.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eRoom size and fresh air (manual Combustion and ventilation air section)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eThe room must be an unconfined space: at least 50 cubic feet per 1,000 BTU\/hr of all gas appliances in the space (some areas require 70).\u003c\/li\u003e\n\u003cli\u003eExample from the manual: a 20 x 16 x 8 ft room (2,560 cu. ft.) supports up to 51,200 BTU\/hr.\u003c\/li\u003e\n\u003cli\u003eIn tighter spaces, add two permanent openings to an adjoining room or outdoors (one within 12\" of the ceiling, one within 12\" of the floor, each at least 1 sq. in. per 1,000 BTU\/hr and 100 sq. in. minimum).\u003c\/li\u003e\n\u003cli\u003eVent-free heaters add moisture to the room; poor ventilation can cause mildew.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVented use and manufactured homes\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFor vented use, the damper must be fixed open to the minimum flue area in the manual chart.\u003c\/li\u003e\n\u003cli\u003eAftermarket, permanently located manufactured homes allowed where local codes permit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes or, where none apply, the \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eAlso cited: the \u003ca href=\"https:\/\/www.iccsafe.org\/\"\u003eInternational Fuel Gas Code (International Code Council)\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003e24 CFR Part 3280 (HUD manufactured home standards)\u003c\/a\u003e (also CAN\/CSA Z240 MH and ANSI\/NCSBCS A225.1\/NFPA 501A where applicable).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eInstall and operate this appliance exactly as the manufacturer's instructions and local codes require. Improper installation, adjustment or maintenance can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide and benzene, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.p65warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e","brand":"Buck Stoves","offers":[{"title":"Propane \/ Millivolt","offer_id":50683083063458,"sku":"GL CR18MVLP","price":812.0,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Modulating","offer_id":50683083096226,"sku":"GL CR18MODLP","price":812.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ Millivolt","offer_id":50683083128994,"sku":"GL CR18MVNAT","price":812.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ Modulating","offer_id":50683083161762,"sku":"GL CR18MODNAT","price":812.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/buck_stove_18in_cr_series_logs_modulating_white_background_2_856fa676-4d0c-4c86-83a2-a467fd7e9a97.jpg?v=1795132691","url":"https:\/\/unitedfireplaces.com\/products\/buck-stove-cr-18-gas-log-set-gl-cr18m","provider":"United Fireplaces","version":"1.0","type":"link"}