{"product_id":"barbara-jean-48-linear-outdoor-burner-system-ob48","title":"Barbara Jean 48\" Linear Outdoor Burner System OB48","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Barbara Jean OB48 is a 48-inch linear outdoor gas burner system, a complete certified and listed burner that you build into your own non-combustible enclosure: a custom fire table, a planter-style fire feature, a bar-height counter or a masonry surround. The burner tray measures 50 in. long by 7-1\/2 in. wide and drops into a 48-1\/2 in. by 5-3\/4 in. opening, and burners can be linked in series for longer runs.\u003c\/p\u003e\u003cp\u003eThis listing is offered with a propane manual valve with thermocouple and push-button igniter (OB48MAPT), a natural gas millivolt valve (OB48MVN), or a natural gas IPI Proflame 2 system with remote control (OB48IPN). Rated up to 80,000 BTU\/h, it throws a long, even ribbon of flame through Barbara Jean ember glass in five colors, or through driftwood, rock sets, stones or cannonballs, with HI\/LO flame adjustment.\u003c\/p\u003e\u003cp\u003eThe burner is Satin Coat steel with a high-temperature black paint finish over a zinc pretreatment for corrosion resistance. Certified for the USA and Canada as an outdoor decorative gas appliance and crafted in Canada, it suits builders and do-it-yourselfers who want a custom outdoor fire feature with a factory-listed burner.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear burner\u003c\/strong\u003e: 48-inch burner, tray 50 in. L x 7-1\/2 in. W, up to 80,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete listed system\u003c\/strong\u003e: Burner, valve, pilot and igniter are certified together to ANSI Z21.97-2017 \/ CSA 2.41-2017 for the USA and Canada.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve choices\u003c\/strong\u003e: OB48MAPT propane manual valve; OB48MVN natural gas millivolt; OB48IPN natural gas IPI Proflame 2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIPI Proflame 2\u003c\/strong\u003e: Remote on\/off, flame control and LED accent lighting control; the remote runs on 3 AAA batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHI\/LO adjustment\u003c\/strong\u003e: Every valve system offers high and low flame settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinks in series\u003c\/strong\u003e: Burners can be joined end to end (for example OB36 and OB48) for longer flame runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt for outdoors\u003c\/strong\u003e: Satin Coat steel, zinc pretreated, high-temperature black paint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedia choices\u003c\/strong\u003e: Five ember glass colors plus driftwood logs, rock sets, stones and cannonballs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlass wind guard option\u003c\/strong\u003e: OB48WG 4-piece tempered glass guard, 5-1\/2 in. high; cuts side clearance to 12 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo power needed (millivolt)\u003c\/strong\u003e: The millivolt valve generates its own power: piezo igniter and on\/off rocker switch, no outlet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel \/ MPN\u003c\/th\u003e\n\u003ctd\u003eOB48MAPT, OB48MVN, OB48IPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eBarbara Jean Collection (Kingsman)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear outdoor gas burner system, 48 in., for custom non-combustible enclosures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003eBurner tray 50 in. L x 7-1\/2 in. W (brochure B0504 and manual p.8, dimensions A x B; allow 1\/8 in. per side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eOpening in the enclosure top 48-1\/2 in. x 5-3\/4 in. (manual pp.17, 20; linked burners: add the lengths plus 1\/2 in.); non-combustible enclosure with at least 71 sq in of air openings; OBUVM2 valve box opening 17 in. W x 8-1\/4 in. H, at least 3 in. from the burner tray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e48-inch linear flame along the 50 in. burner tray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eSides of burner tray 24 in.; ends 12 in.; top of tray to ceiling 49-1\/2 in.; top of tray at least 8 in. above the floor; 12 in. with a wind guard in place; valve, switch and remote receiver at least 5 in. below the top of the tray (0 in. with the OBUVM2 valve box) (manual pp.6, 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas input\u003c\/th\u003e\n\u003ctd\u003eOB48MAPT: propane 22,500 low \/ 60,500 high BTU\/h (#40 orifice); natural gas with the included orifice 13,000 low \/ 58,000 high BTU\/h (#15)\u003cbr\u003eOB48MVN: natural gas 54,000 low \/ 80,000 high BTU\/h (#14 orifice); propane by kit 61,000 low \/ 80,000 high BTU\/h (#37)\u003cbr\u003eOB48IPN: natural gas 54,000 low \/ 80,000 high BTU\/h (#14 orifice); propane by kit 61,000 low \/ 80,000 high BTU\/h (#37)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eMAPT: manual valve with thermocouple, push-button igniter (one AAA battery, not included); MVN: millivolt valve, piezo igniter, on\/off rocker switch on the valve; IPN: IPI Proflame 2 intermittent pilot with remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eNone: outdoor decorative appliance for open-air use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8 in. NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply pressure\u003c\/th\u003e\n\u003ctd\u003eManual valve: natural gas 7 in. w.c.; propane 10 in. w.c.\u003cbr\u003eMillivolt \/ IPI: natural gas 5.5 in. min, 7 in. normal, 10 in. max (manifold 1.6 in. low, 3.5 in. high); propane 11 in. min and normal, 13 in. max (manifold 6.3 in. low, 10 in. high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003eIPN: AC power to the Proflame 2 IFC module through the supplied power cord harness, grounded three-prong plug into an outdoor GFI-protected outlet; no battery backup is available. MAPT and MVN: none\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass media\u003c\/th\u003e\n\u003ctd\u003e5 bags x 5 lb (25 lb; 5 lb per foot of burner), no more than 1 in. above the burner tray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eOrifices rated 0-4,500 ft; above 4,500 ft derate 4% per 1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eANSI Z21.97-2017 \/ CSA 2.41-2017 outdoor decorative gas appliance (USA and Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e48-inch linear burner tray with pilot assembly and pilot shield\u003c\/li\u003e\n\u003cli\u003eOB48MAPT: manual valve with regulator and 10 ft hose, thermocouple, push-button igniter with wire and sparker, brass orifice for natural gas conversion (manual p.10)\u003c\/li\u003e\n\u003cli\u003eOB48MVN: millivolt valve system with orifice and pilot assembly, piezo igniter with wire and sparker, on\/off rocker switch installed on the valve (manual p.13)\u003c\/li\u003e\n\u003cli\u003eOB48IPN: IPI Proflame 2 valve, IFC module, power cord harness and remote control, with LED lights (manual p.50)\u003c\/li\u003e\n\u003cli\u003eInstallation and operating manual 24OB-MAN17\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEmber glass or other Barbara Jean media: 5 bags of 5 lb (25 lb)\u003c\/li\u003e\n\u003cli\u003eNon-combustible enclosure with a 48-1\/2 in. x 5-3\/4 in. burner opening, at least 71 sq in of air openings and drainage\u003c\/li\u003e\n\u003cli\u003eGas supply: natural gas line, or a propane cylinder built to DOT or CAN\/CSA-B339 with an overfilling prevention device\u003c\/li\u003e\n\u003cli\u003eOne AAA battery for the MAPT push-button igniter (not included)\u003c\/li\u003e\n\u003cli\u003eOutdoor GFI-protected electrical outlet for the IPN Proflame 2 module, and 3 AAA batteries for the remote\u003c\/li\u003e\n\u003cli\u003eTo run a natural gas burner on propane: LP conversion kit 48OB-CKLP (millivolt) or 48OB-CKLP2 (IPI)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEmber glass, 5 lb bags: MQG5ZG zircon glacier ice, MQG5A cobalt blue, MQG5B black, MQG5C bronze, MQG5W white\u003c\/li\u003e\n\u003cli\u003eOB48WG glass wind guard, 4 pieces, 5-1\/2 in. high\u003c\/li\u003e\n\u003cli\u003e48LT-LID burner lid\u003c\/li\u003e\n\u003cli\u003eOFP42SA spark assist for the millivolt valve (one AA battery, not included)\u003c\/li\u003e\n\u003cli\u003eOBUVM2 universal valve box (millivolt and IPI)\u003c\/li\u003e\n\u003cli\u003e27FP-900FF propane regulator with 5 ft hose; 24OFS-P120 regulator with 10 ft hose\u003c\/li\u003e\n\u003cli\u003eMQRBD3 driftwood log set, 5 pieces\u003c\/li\u003e\n\u003cli\u003eMQRBD4 driftwood log set, 3 pieces\u003c\/li\u003e\n\u003cli\u003eMQROCK2 contemporary rock set\u003c\/li\u003e\n\u003cli\u003eMQSTONE decorative stones\u003c\/li\u003e\n\u003cli\u003eMQSTONE10 decorative stones, 10 pieces\u003c\/li\u003e\n\u003cli\u003eRBCB1 cannonballs, 14 pieces\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eProduct video\u003c\/h3\u003e\u003cdiv class=\"uf-desc-video\" style=\"position:relative;width:100%;max-width:960px;aspect-ratio:16\/9;margin:0 0 16px\"\u003e\u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/A56tifm6sTA?rel=0\" title=\"Barbara Jean outdoor collection video\" loading=\"lazy\" style=\"position:absolute;inset:0;width:100%;height:100%;border:0;border-radius:4px\" allow=\"accelerometer; encrypted-media; gyroscope; picture-in-picture; fullscreen\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e This is an outdoor gas appliance. Improper installation, adjustment or use can cause fire, explosion or carbon-monoxide exposure. Follow manual 24OB-MAN17 exactly, keep children and pets away from hot surfaces, and use it outdoors only.\u003c\/p\u003e\u003ch4\u003eWarnings \u0026amp; gas line installation\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFor outdoor use only; not for use in temperatures below freezing (pp.2, 5).\u003c\/li\u003e\n\u003cli\u003eNatural gas needs at least 3\/8 in. iron pipe from the meter and at least 4.5 in. w.c.; connect through the left-side or bottom knockout with a union for service (p.5).\u003c\/li\u003e\n\u003cli\u003eLeak-test every joint with soap solution, never an open flame (p.5).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eLocating your appliance \u0026amp; clearances\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eAllowed: walls on all sides with no overhead cover (96 sq ft minimum and a permanent ground-level opening); an overhead cover with no more than two side walls; or three side walls with at least 30% of the perimeter permanently open (p.6).\u003c\/li\u003e\n\u003cli\u003eScreened porch: at least 96 sq ft with two sides fully open, or screened walls with at least 64 sq ft of screen and 78 in. wall height (p.6).\u003c\/li\u003e\n\u003cli\u003eClearances: 24 in. from the sides and 12 in. from the ends of the burner tray, 49-1\/2 in. to a ceiling, tray top at least 8 in. above the floor; 12 in. with a wind guard (p.6).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBurner systems for custom applications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBurners may be connected in series; only one ON\/OFF device may be used on the appliance (p.8).\u003c\/li\u003e\n\u003cli\u003eValve, ON\/OFF switch and remote receiver must sit at least 5 in. below the top of the burner, or 0 in. inside the OBUVM2 valve box (pp.6, 8).\u003c\/li\u003e\n\u003cli\u003eManual valve control panel cutout: 2-7\/16 in. high x 7-1\/2 in. wide, within 12 in. of the burner orifice bracket (p.11).\u003c\/li\u003e\n\u003cli\u003eStock burner opening 48-1\/2 in. x 5-3\/4 in.; enclosure non-combustible with at least 71 sq in of air openings; gas controls supported, accessible and readily removable; do not insulate around the burner; provide drainage (pp.2, 6, 17, 20).\u003c\/li\u003e\n\u003cli\u003eOBUVM2 universal valve box: opening 17 in. W x 8-1\/4 in. H, at least 3 in. from the burner tray (p.19).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eEnclosures for LP gas supply\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUpper vents 1 sq in per lb of stored fuel and floor vents 1\/2 sq in per lb; the cylinder floor sits at least 2 in. above the ground (p.21).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGlass media, burner lids \u0026amp; wind guards\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUse 5 bags (25 lb) of Barbara Jean glass, no more than 1 in. above the burner tray; never cover the pilot (pp.17, 24).\u003c\/li\u003e\n\u003cli\u003eBurner lid 48LT-LID sits 1 in. above the burner and extends 3\/4 in. past the ends; turn the pilot knob OFF before fitting it (p.26).\u003c\/li\u003e\n\u003cli\u003eWind guards are recommended on outdoor burners and assemble from tempered glass panels and corner brackets (pp.27-28).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eKeep the burner, pilot and media clean and dry; inadequate drainage causes rust, which the warranty does not cover (pp.2, 29-30).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eLighting, gas specifications \u0026amp; conversion\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eManual valve: the push-button igniter lights the pilot; the manual valve with thermocouple sets the flame HI or LO (pp.10, 31).\u003c\/li\u003e\n\u003cli\u003eMillivolt: the piezo igniter lights the pilot and the on\/off rocker switch turns the burner on and off; the millivolt generator should read at least 325 mV (pp.32, 42).\u003c\/li\u003e\n\u003cli\u003eIPI Proflame 2: with electric power on, the ON\/OFF key on the remote lights the burner through automatic pilot ignition (p.34).\u003c\/li\u003e\n\u003cli\u003eMAPT ships for propane; to convert to natural gas, fit the supplied #15 orifice, set the air shutter to 1\/16 in. open and remove the LP hose and regulator (pp.35-36).\u003c\/li\u003e\n\u003cli\u003eNatural gas millivolt and IPI burners convert to propane with the 48OB-CKLP or 48OB-CKLP2 kit; propane air shutter fully open (pp.35-38).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eIPI Proflame 2 \u0026amp; LED lighting\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eConnect the grounded three-prong plug to an external GFI-protected outlet near the burner (pp.43, 46).\u003c\/li\u003e\n\u003cli\u003eThe remote uses 3 AAA batteries; the OPTION button selects LIGHT, AUX or FLAME control, and the LED kit cycles colour modes 0-22 (pp.45, 47).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eGas: local codes or, where none apply, the \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e in the USA, or CSA B149.1 (Natural Gas and Propane Installation Code) in Canada\u003c\/li\u003e\n\u003cli\u003ePropane storage and cylinders: CSA B149.2 (Propane Storage and Handling Code); cylinders built to U.S. DOT specifications or CAN\/CSA-B339\u003c\/li\u003e\n\u003cli\u003eElectrical (IPI models): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e in the USA, or CSA C22.1 (Canadian Electrical Code)\u003c\/li\u003e\n\u003cli\u003eCertification standard: ANSI Z21.97 \/ CSA 2.41 (outdoor decorative gas appliances)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBarbara Jean Collection limited warranty, manual 24OB-MAN17 p.52.\u003c\/li\u003e\n\u003cli\u003eBurner: 5 years.\u003c\/li\u003e\n\u003cli\u003eGas valves, thermocouples, igniters, lights and media: 1 year.\u003c\/li\u003e\n\u003cli\u003eCoverage area: continental USA, Alaska, Hawaii and Canada, only at the original installation site, when installed and operated per the instructions; without proof of installation the start date is the manufacture date plus 30 days.\u003c\/li\u003e\n\u003cli\u003eNot covered: scratches, dents, painted finishes, heat discoloring, corrosion, damage from abrasive or chemical cleaners, chipped porcelain or powder-coated parts, labor and freight.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/barbarajeancollection.com\/wp-content\/uploads\/2024\/08\/24OB-MAN17.pdf\"\u003eLinear Outdoor Burner and Fire Stand installation and operating manual 24OB-MAN17\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/barbarajeancollection.com\/wp-content\/uploads\/2017\/02\/18449-BJC-B0504-Burners-ENGLISH-May2023-FNL-Web.pdf\"\u003eBarbara Jean Burners brochure B0504 (May 2023)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/barbarajeancollection.com\/wp-content\/uploads\/2022\/07\/OB-Burners-Dimensions.zip\"\u003eBarbara Jean burner dimension drawings (CAD, ZIP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/barbarajeancollection.com\/warranty\"\u003eBarbara Jean warranty page\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — OB48\u003c\/h3\u003e\u003ch4\u003eWhat size opening does the OB48 need?\u003c\/h4\u003e\u003cp\u003eCut a 48-1\/2 in. by 5-3\/4 in. opening in a non-combustible enclosure top for the 50 in. by 7-1\/2 in. burner tray, and give the enclosure at least 71 sq in of air openings.\u003c\/p\u003e\u003ch4\u003eWhich gas does it use?\u003c\/h4\u003e\u003cp\u003eOB48MAPT ships for propane with a natural gas orifice included. OB48MVN and IPN are natural gas and convert to propane with the 48OB-CKLP or 48OB-CKLP2 kit.\u003c\/p\u003e\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eThe manual valve and millivolt versions need no electricity. The IPI Proflame 2 version needs AC power to its module, and Barbara Jean offers no battery backup for it.\u003c\/p\u003e\u003ch4\u003eHow much glass media do I need?\u003c\/h4\u003e\u003cp\u003e5 bags of 5 lb (25 lb), no more than 1 in. above the burner tray.\u003c\/p\u003e\u003ch4\u003eWhat clearances does it need?\u003c\/h4\u003e\u003cp\u003e24 in. from the sides and 12 in. from the ends of the burner tray, 49-1\/2 in. to a ceiling, and 12 in. with a wind guard in place.\u003c\/p\u003e\u003ch4\u003eWhat's the warranty?\u003c\/h4\u003e\u003cp\u003eThe burner is warranted for 5 years; gas valves, thermocouples, igniters, lights and media for 1 year.\u003c\/p\u003e","brand":"Barbara Jean","offers":[{"title":"Propane \/ Manual valve with thermocouple","offer_id":50912170705058,"sku":"OB48MAPT","price":914.55,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ Millivolt","offer_id":50912170737826,"sku":"OB48MVN","price":1083.6,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI Proflame 2 with remote and LED","offer_id":50912170770594,"sku":"OB48IPN","price":2542.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/burners1-2000x1075_d0d96d93-51e9-4d7b-a1ea-cb34e1de2a4b.jpg?v=1795038770","url":"https:\/\/unitedfireplaces.com\/products\/barbara-jean-48-linear-outdoor-burner-system-ob48","provider":"United Fireplaces","version":"1.0","type":"link"}