{"product_id":"american-hearth-60-boulevard-direct-vent-linear-fireplace-with-thermostat-variable-remote-dvll60bp90","title":"Empire Hearth 60\" Boulevard Direct Vent Linear Fireplace DVLL60BP90","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eEmpire Boulevard DVLL60BP90 is a 60-inch single-sided linear direct-vent gas fireplace. Electronic ignition and a multifunction remote control operate the burner, with model-specific accent lighting and optional blower control.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cp\u003eWide ceramic-glass flame presentation with an approved crushed-glass bed and a separately selected required liner.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/www.youtube.com\/embed\/C08LojhZvcY?list=PLBF1F865E22F2BCFE\"\u003eView manufacturer product video\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/www.youtube.com\/embed\/EUitatIf8Ec?list=PLis-ANPlrWPohFkMl3Fc9FgLw8yhfXus9\"\u003eView manufacturer product video\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cp\u003eMultifunction remote, ceramic glass, protective barrier screen, factory accent lighting and noncombustible board for the specified finishing areas.\u003c\/p\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cp\u003eA liner must be installed before operation: choose the DVP60LPZ bronze Ridgeback liner or DVP60LKR black porcelain liner. Retain and install the required protective barrier. Crushed glass must follow the manufacturer's placement diagram: use a single layer to mask the burner screen, approximately one square foot, with no more than seven square feet of approved 1\/4-inch crushed glass in total. Keep glass out of the recessed pilot, sensor and ignitor area. \u003c\/p\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cp\u003eOptional LS60THF logs and rocks, decorative fronts and trim, and the FBB20 dual blower do not replace the required liner or correct media placement.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNatural-gas input\u003c\/th\u003e\n\u003ctd\u003e31,000–46,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePropane input\u003c\/th\u003e\n\u003ctd\u003e32,500–42,500 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass dimensions\u003c\/th\u003e\n\u003ctd\u003e60 inches wide × 15 inches high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming opening\u003c\/th\u003e\n\u003ctd\u003e79 5\/8 inches wide × 49 3\/8 inches high × 21 1\/2 inches deep; verify finishing method and the actual appliance before framing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e5-inch inner × 8-inch outer direct vent; use a listed system and the permitted routing, rise, run and termination in the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical supply\u003c\/th\u003e\n\u003ctd\u003e120 V, 60 Hz, 1 A; right-side entrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2-inch NPT; right-side entrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003eThe installation manual provides different height and depth measurements in its specification table and dimension drawing. Confirm the dimension reference and exact supplied revision with the installer before construction. Follow the full clearance and mantel diagrams, noncombustible-board instructions, vent charts and applicable codes; the framing opening is not a substitute for those requirements.\u003c\/p\u003e\u003ch3\u003eManuals and downloads\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.empireinsider.com\/wp-content\/uploads\/2025\/10\/43147-DVLL60BP92-4-Installer.pdf\"\u003eDVLL60BP90(N,P)-4 installation manual, 43147-5-0825\u003c\/a\u003e: electrical planning on page 2, fuel ratings on page 6, accessories and conversion kits on page 7, dimensions on page 11, clearances on page 12, framing on page 20, listed vent systems on page 24, required liner on page 36 and glass placement on page 37. Use the manual matching the appliance rating-plate revision.\u003c\/p\u003e","brand":"Empire Hearth","offers":[{"title":"Propane - Multifunction Remote, Accent Light","offer_id":50604545638562,"sku":"DVLL60BP90P","price":6989.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas - Multifunction Remote, Accent Light","offer_id":50604545671330,"sku":"DVLL60BP90N","price":6989.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Empire-Hearth-60-Boulevard-Direct-Vent-Linear-Fireplace-DVLL60BP90_1689__88332.1785136121.386.513.jpg?v=1791841240","url":"https:\/\/unitedfireplaces.com\/products\/american-hearth-60-boulevard-direct-vent-linear-fireplace-with-thermostat-variable-remote-dvll60bp90","provider":"United Fireplaces","version":"1.0","type":"link"}