{"title":"Kingsman","description":"\u003cp\u003eShop Kingsman gas fireplaces, fireplace inserts and direct vent gas stoves at United Fireplaces, including the ZCVRB linear series, the Marquis MCVP42 peninsula and MCVST42 see-through models, the HBZDV clean-face fireplaces and the FDV freestanding stoves. Each product page lists the required media, venting and accessories for that exact model, taken from Kingsman's installation manuals.\u003c\/p\u003e","products":[{"product_id":"kingsman-fdv200s-direct-vent-gas-stove-fdv200s","title":"Kingsman FDV200S Direct Vent Gas Stove FDV200S","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman FDV200S is the compact model in Kingsman's freestanding direct vent gas stove range. It gives the look of a traditional stove to rooms with no chimney, such as living rooms, cottages, basements and additions, and it is approved for mobile homes, bedrooms and bed-sitting rooms. With only 6\" side and 3\" back clearances it suits tight rooms, corners at 45° and alcoves.\u003c\/p\u003e\u003cp\u003eA dual burner lights a realistic fire on the LOGF200 five-piece fibre oak log set or the LOGC200 cast split oak set, both with glowing embers, behind 5 mm heat-radiating ceramic glass and a safety screen barrier. An optional FDV200RL three-piece brick liner adds a masonry look inside.\u003c\/p\u003e\u003cp\u003eInput is 28,500 BTU\/h on natural gas and 26,000 BTU\/h on propane, with Hi\/Lo flame and heat adjustment and a fireplace efficiency of up to 68.56% (NG) and 69.89% (LP). A millivolt valve needs no house power and IPI ignition has battery backup, so it keeps heating in a power outage; E2 models include a Proflame 2 remote. It vents through the wall or roof from a 4\"\/7\" collar, and the optional F45FK fan adds circulation.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFreestanding direct vent stove\u003c\/strong\u003e: sealed combustion; outside air for the fire.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMillivolt or IPI valve\u003c\/strong\u003e: operates during a power failure with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (E2 models)\u003c\/strong\u003e: flame, fan, thermostat and smart thermostat control, with battery backup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual burner\u003c\/strong\u003e: with a realistic flame pattern.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-radiating ceramic glass\u003c\/strong\u003e: Robax or coated Neoceram, 5 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLog set\u003c\/strong\u003e: LOGF200 five-piece fibre oak log set with glowing embers (listed as required; order separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 28,500 \/ 19,500 BTU\/h natural gas; 26,000 \/ 20,000 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 66.14% MV \/ 68.56% IPI (NG); 67.47% \/ 69.89% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: mobile home approved; bedroom and bed-sitting room approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: F45FK heat activated with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall thermostat (optional)\u003c\/strong\u003e: Z2MT millivolt or Z80PT programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional, millivolt)\u003c\/strong\u003e: on\/off, thermostatic, thermostatic modulating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefractory brick liner (optional)\u003c\/strong\u003e: FDV200RL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDecorative black collar (optional)\u003c\/strong\u003e: F7DBC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDecorative black wall trim plate (optional)\u003c\/strong\u003e: F7DTP.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: kits 200DV-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eFDV200SN \/ FDV200SLP (millivolt); FDV200SNE2 \/ FDV200SLPE2 (IPI Proflame 2 with remote)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eFreestanding direct vent gas stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eNone required (freestanding). Alcove installation: at least 30\" deep, 55-1\/2\" high and 52-1\/2\" wide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eFront 36\"; sides 6\"; back 3\"; corner (45°) 3\"; top of a 90° elbow 4\"; top of horizontal pipe 2-1\/2\"; vertical venting 1\"; all other existing pipes 1\". Floor: may sit directly on carpet, tile or other combustible flooring with no added floor protection; a hearth is recommended, and installing on vinyl is at the installer's risk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e28,500 \/ 19,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e26,000 \/ 20,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e66.14% MV \/ 68.56% IPI (NG); 67.47% \/ 69.89% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic, 5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eDirect vent, 4\"\/7\" flue collar. Rigid DuraVent DirectVent Pro 4\" x 6-5\/8\" pipe with the Kingsman ZDVDKA stove adapter (horizontal or vertical termination)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eMillivolt or IPI Proflame 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eStove with dual burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eCeramic glass door (5 mm Robax or coated Neoceram)\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier (replacement part F200CSS)\u003c\/li\u003e\n\u003cli\u003eProflame 2 remote (FDV200SNE2 \/ FDV200SLPE2 only)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne log set (required for each unit): LOGF200 five-piece fibre oak log set or LOGC200 cast split oak log set, both with embers\u003c\/li\u003e\n\u003cli\u003eDirect vent pipe from the 4\"\/7\" collar: Kingsman (Z-Flex) venting components labelled for this stove, or DuraVent DirectVent Pro 4\" x 6-5\/8\" rigid pipe; BDM Pro Form, Ameri-Vent, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp direct vent systems are also approved\u003c\/li\u003e\n\u003cli\u003eZDVDKA DuraVent hard-pipe stove adapter (required with rigid DuraVent pipe)\u003c\/li\u003e\n\u003cli\u003eOne termination: FDVHSQ or FDVHT horizontal, FDVVT40 vertical, or Z47ST24 \/ Z47ST36 snorkel\u003c\/li\u003e\n\u003cli\u003eZDVFS firestop spacer (vertical runs through floors and ceilings)\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan or IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFDV200RL refractory brick liner, 3 pieces\u003c\/li\u003e\n\u003cli\u003eF45FK fan kit with variable speed control (millivolt \/ Proflame 1 models)\u003c\/li\u003e\n\u003cli\u003eF45FK2 fan kit (Proflame 2 models)\u003c\/li\u003e\n\u003cli\u003eF7DBC decorative black collar, 7\"\u003c\/li\u003e\n\u003cli\u003eF7DTP decorative black wall trim plate\u003c\/li\u003e\n\u003cli\u003eZ2MT millivolt wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable digital millivolt wall thermostat\u003c\/li\u003e\n\u003cli\u003eGFRC remote (millivolt models)\u003c\/li\u003e\n\u003cli\u003eGTRC thermostat remote (millivolt models)\u003c\/li\u003e\n\u003cli\u003eGTMRCN thermostat \/ modulating remote, natural gas (millivolt models)\u003c\/li\u003e\n\u003cli\u003eGTMRCP thermostat \/ modulating remote, propane (millivolt models)\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI models)\u003c\/li\u003e\n\u003cli\u003eOFP42SA spark assist\u003c\/li\u003e\n\u003cli\u003eZDVSSLR vinyl siding shield\u003c\/li\u003e\n\u003cli\u003eZ57STSC snorkel safety cage\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2024\/01\/200S-MAN19.pdf\"\u003eFDV200S installation and operating manual (200S-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/12\/21380-KM-B045-FDV200sENG-Dec2025-FNL1-Web.pdf\"\u003eFDV200S brochure and specifications (Dec 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (FDV200S installation and operating manual (200S-MAN19), safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.4–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eMobile home approved; approved for bedrooms and bed-sitting rooms.\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eLocation, clearances and floor (pp.10–12)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eClearances: front 36\", sides 6\", back 3\"; corner (45°) 3\"; top of a 90° elbow 4\"; horizontal pipe top 2-1\/2\" (p.10).\u003c\/li\u003e\n\u003cli\u003eAlcove: at least 30\" deep, 55-1\/2\" high and 52-1\/2\" wide (p.10).\u003c\/li\u003e\n\u003cli\u003eInstall on a hard, stable surface; carpet and tile are fine, a hearth is recommended over vinyl.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAccessories, liners and logs (pp.13–17)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eF45FK fan: variable speed control, needs a grounded 120 VAC receptacle.\u003c\/li\u003e\n\u003cli\u003eLog set: LOGF200 five-piece fibre oak log set with glowing embers (listed as required; order separately); follow the placement diagram and keep the pilot clear.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm Robax or coated Neoceram; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas, maintenance and conversion (pp.18–22)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.18).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.18).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.18).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.18). Field conversion between natural gas and propane uses Kingsman kits 200DV-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI), installed by a qualified agency (pp.19–22).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and ignition (pp.23–40)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.23–40).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.41–49)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVenting: Direct vent, 4\"\/7\" flue collar. Rigid DuraVent DirectVent Pro 4\" x 6-5\/8\" pipe with the Kingsman ZDVDKA stove adapter (horizontal or vertical termination).\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 4-1\/2 ft (stove 4\" from the wall); maximum vertical 40 ft; maximum horizontal 20 ft with one 90° elbow and 7 ft of vertical; 1\/4\" rise per 12\" of run.\u003c\/li\u003e\n\u003cli\u003eEach extra 90° elbow takes 36\" off the horizontal run and each 45° takes 18\"; propane horizontal runs need 1 ft more vertical rise.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.8).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.7).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (FDV200S installation and operating manual (200S-MAN19), p.53).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — FDV200S\u003c\/h3\u003e\n\u003ch4\u003eDoes the FDV200S need framing or a hearth?\u003c\/h4\u003e\u003cp\u003eNo framing is needed; it is a freestanding stove. In an alcove the space must be at least 30\" deep, 55-1\/2\" high and 52-1\/2\" wide. It can sit directly on carpet, tile or other combustible flooring with no added floor protection; a hearth is recommended, and vinyl flooring is at the installer's risk.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt is direct vent from a 4\"\/7\" collar, through the wall or the roof, to an FDVHSQ or FDVHT horizontal, FDVVT40 vertical, or Z47ST24 \/ Z47ST36 snorkel termination. The vertical rise can be up to 40 ft, and the horizontal run up to 20 ft with one 90° elbow and 7 ft of vertical. The shortest setup is 4-1\/2 ft vertical with the stove 4\" from the wall. Up to three 90° elbows are allowed; rigid DuraVent DirectVent Pro pipe needs the ZDVDKA adapter.\u003c\/p\u003e\n\u003ch4\u003eHow close can it sit to a wall?\u003c\/h4\u003e\u003cp\u003eClearances to combustibles are 6\" at the sides, 3\" at the back, 3\" in a 45° corner and 36\" in front, with 4\" above a 90° elbow and 2-1\/2\" above horizontal pipe.\u003c\/p\u003e\n\u003ch4\u003eCan the FDV200S be converted between natural gas and propane?\u003c\/h4\u003e\u003cp\u003eYes. Kingsman conversion kits 200DV-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI) convert it, installed by a qualified agency. Input is 28,500 \/ 19,500 BTU\/h on natural gas and 26,000 \/ 20,000 BTU\/h on propane (max\/min).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup (four AA batteries) that keeps the fire working in an outage; the optional fan does not run on battery.\u003c\/p\u003e\n\u003ch4\u003eWhat's the warranty?\u003c\/h4\u003e\u003cp\u003eKingsman's Limited Lifetime Warranty: every component is covered for parts and labour for the first year, and the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the stove. Bulbs, gasketing, glass and paint are not covered by the one-year warranty.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912046416034,"sku":"FDV200SN","price":3156.41,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912046448802,"sku":"FDV200SLP","price":3228.86,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI Proflame 2 with Remote","offer_id":50912046481570,"sku":"FDV200SNE2","price":4150.18,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI Proflame 2 with Remote","offer_id":50912046514338,"sku":"FDV200SLPE2","price":4223.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/TITAN_786413_FiberOak_LivingRoom_Jun2019-1-crop.jpg?v=1795037926"},{"product_id":"kingsman-fdv350-bay-direct-vent-gas-stove-fdv350","title":"Kingsman FDV350 Bay Direct Vent Gas Stove FDV350","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman FDV350 Bay is a freestanding direct vent gas stove with a bay-window front: heat-radiating ceramic glass on three sides gives a panoramic view of the fire from across the room. It brings a traditional stove look to living rooms, cottages, basements and additions with no chimney, and it is approved for bedrooms, bed-sitting rooms and (as a direct vent stove) mobile homes.\u003c\/p\u003e\u003cp\u003eA dual burner lights a realistic fire on the LOGF35 fibre split oak log set with embers, under a black louver. The front is completed with the F35DB black door frame and ceramic glass, and the optional F35RL brick liner adds a masonry look inside.\u003c\/p\u003e\u003cp\u003eInput is 37,000 BTU\/h on natural gas and 35,000 BTU\/h on propane, with Hi\/Lo flame and heat adjustment and a fireplace efficiency of up to 67.9% (NG) and 70.10% (LP). A millivolt valve needs no house power and IPI ignition has battery backup, so it keeps heating in a power outage; E2 models include a Proflame 2 remote. It vents through the wall or roof from a 4\"\/7\" collar, or into an existing chimney or B-vent with the F35BVC converter.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFreestanding direct vent stove\u003c\/strong\u003e: sealed combustion; outside air for the fire.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMillivolt or IPI valve\u003c\/strong\u003e: operates during a power failure with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (E2 models)\u003c\/strong\u003e: flame, fan, thermostat and smart thermostat control, with battery backup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual burner\u003c\/strong\u003e: with a realistic flame pattern.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-radiating ceramic glass\u003c\/strong\u003e: Robax or coated Neoceram, 5 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLog set\u003c\/strong\u003e: LOGF35 Fibre Split Oak log set with ember chunks (ordered separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: F350CSS black-frame safety screen, listed as required for each unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 37,000 \/ 29,000 BTU\/h natural gas; 35,000 \/ 27,000 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 66.63% MV \/ 67.9% IPI (NG); 67.64% \/ 70.10% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: mobile home approved (direct vent only); bedroom and bed-sitting room approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: F45FK heat activated with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall thermostat (optional)\u003c\/strong\u003e: Z2MT millivolt or Z80PT programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional, millivolt)\u003c\/strong\u003e: on\/off, thermostatic, thermostatic modulating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefractory brick liner (optional)\u003c\/strong\u003e: F35RL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlack door frame with ceramic glass (required, sold separately)\u003c\/strong\u003e: F35DB completes the stove front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB-vent adapter (optional)\u003c\/strong\u003e: F35BVC converts the stove to an existing 4\" B-vent or lined chimney.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: kits 350DV-CKLP \/ -CKNG (millivolt) and 350DV-CKLPI \/ -CKNGI \/ -CKLPI2 \/ -CKNGI2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eFDV350N \/ FDV350LP (millivolt); FDV350NE2 \/ FDV350LPE2 (IPI Proflame 2 with remote)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eFreestanding direct vent gas stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eNone required (freestanding). Alcove installation: at least 30\" deep, 55-1\/2\" high and 52-1\/2\" wide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer (ceramic glass on three sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eFront 36\"; sides 12\"; back 3\"; corner (45°) 3\"; top of a 90° elbow 4\"; top of horizontal pipe 2-1\/2\"; vertical venting 1\"; all other existing pipes 1\". Floor: may sit directly on carpet, tile or other combustible flooring; a hearth is recommended over luxury vinyl flooring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e37,000 \/ 29,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e35,000 \/ 27,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e66.63% MV \/ 67.9% IPI (NG); 67.64% \/ 70.10% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic, 5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eDirect vent, 4\"\/7\" flue collar. Rigid DuraVent DirectVent Pro 4\" x 6-5\/8\" pipe with the Kingsman ZDVDKA stove adapter (horizontal or vertical termination); optional 4\" B-vent with F35BVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eMillivolt or IPI Proflame 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eStove with dual burner and black louver, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eEmber chunks\u003c\/li\u003e\n\u003cli\u003eProflame 2 remote (FDV350NE2 \/ FDV350LPE2 only)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLOGF35 fibre split oak log set with embers (required for each unit)\u003c\/li\u003e\n\u003cli\u003eF35DB door frame and ceramic glass, black (required for each unit)\u003c\/li\u003e\n\u003cli\u003eF350CSS safety screen, black frame (listed by Kingsman as required for each unit)\u003c\/li\u003e\n\u003cli\u003eDirect vent pipe from the 4\"\/7\" collar: Kingsman (Z-Flex) venting components labelled for this stove, or DuraVent DirectVent Pro 4\" x 6-5\/8\" rigid pipe; BDM Pro Form, Ameri-Vent, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp direct vent systems are also approved\u003c\/li\u003e\n\u003cli\u003eZDVDKA DuraVent hard-pipe stove adapter (required with rigid DuraVent pipe)\u003c\/li\u003e\n\u003cli\u003eOne termination: FDVHSQ or FDVHT horizontal, FDVVT40 vertical, or Z47ST24 \/ Z47ST36 snorkel\u003c\/li\u003e\n\u003cli\u003eVertical installs: ZDVFS firestop spacer (required through floors and ceilings), ZDVAIS attic insulation shield and ZDV7SC storm collar\u003c\/li\u003e\n\u003cli\u003eOr, instead of direct vent pipe: F35BVC B-vent converter into an existing 4\" B-vent or lined chimney, 12 ft minimum to 60 ft maximum (not allowed in mobile homes)\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan or IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eF35RL refractory brick liner\u003c\/li\u003e\n\u003cli\u003eF45FK fan kit with variable speed control (millivolt \/ Proflame 1 models)\u003c\/li\u003e\n\u003cli\u003eF45FK2 fan kit (Proflame 2 models)\u003c\/li\u003e\n\u003cli\u003eF7DBC decorative black collar, 7\"\u003c\/li\u003e\n\u003cli\u003eF7DTP decorative black wall trim plate\u003c\/li\u003e\n\u003cli\u003eZ2MT millivolt wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable digital millivolt wall thermostat\u003c\/li\u003e\n\u003cli\u003eGFRC on\/off remote (millivolt \/ IPI)\u003c\/li\u003e\n\u003cli\u003eGTRC thermostat remote (millivolt)\u003c\/li\u003e\n\u003cli\u003eGTMRCN thermostat \/ modulating remote, natural gas (millivolt)\u003c\/li\u003e\n\u003cli\u003eGTMRCP thermostat \/ modulating remote, propane (millivolt)\u003c\/li\u003e\n\u003cli\u003eGTFRCN \/ GTFRCP thermostat \/ modulating remote with fan control (millivolt)\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI models)\u003c\/li\u003e\n\u003cli\u003eZDVSSLR vinyl siding shield\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2024\/01\/350-MAN19.pdf\"\u003eFDV350 installation and operating manual (350-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2023\/08\/18595-KM-B030-FDV350ENG-Aug2023-WEB2.pdf\"\u003eFDV350 brochure and specifications (Aug 2023)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (FDV350 installation and operating manual (350-MAN19), safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.1–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eMobile home approved (direct vent only; not when converted to B-vent); approved for bedrooms and bed-sitting rooms.\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eLocation, clearances and floor (pp.10)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eClearances: front 36\", sides 12\", back 3\"; corner (45°) 3\"; top of a 90° elbow 4\"; horizontal pipe top 2-1\/2\" (p.10).\u003c\/li\u003e\n\u003cli\u003eAlcove: at least 30\" deep, 55-1\/2\" high and 52-1\/2\" wide (p.10).\u003c\/li\u003e\n\u003cli\u003eInstall on a hard, stable surface; carpet and tile are fine, a hearth is recommended over vinyl.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAccessories, liners and logs (pp.11–15)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eF45FK fan: variable speed control, needs a grounded 120 VAC receptacle.\u003c\/li\u003e\n\u003cli\u003eLog set: LOGF35 Fibre Split Oak log set with ember chunks (ordered separately); follow the placement diagram and keep the pilot clear.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm Robax or coated Neoceram; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas, maintenance and conversion (pp.16–19)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.16).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.16).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.16).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.16). Field conversion between natural gas and propane uses Kingsman kits 350DV-CKLP \/ -CKNG (millivolt) and 350DV-CKLPI \/ -CKNGI \/ -CKLPI2 \/ -CKNGI2 (IPI) (p.17), installed by a qualified agency (pp.17–19).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and ignition (pp.20–39)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.20–39).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.40–49)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVenting: Direct vent, 4\"\/7\" flue collar. Rigid DuraVent DirectVent Pro 4\" x 6-5\/8\" pipe with the Kingsman ZDVDKA stove adapter (horizontal or vertical termination); optional 4\" B-vent with F35BVC.\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 4-1\/2 ft (stove 4\" from the wall); maximum vertical 40 ft; maximum horizontal 20 ft with one 90° elbow and 7 ft of vertical; 1\/4\" rise per 12\" of run.\u003c\/li\u003e\n\u003cli\u003eEach extra 90° elbow takes 36\" off the horizontal run and each 45° takes 18\"; propane horizontal runs need 1 ft more vertical rise.\u003c\/li\u003e\n\u003cli\u003eB-vent conversion with F35BVC into an existing 4\" B-vent or lined chimney, 12–60 ft.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.8).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.7).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (FDV350 installation and operating manual (350-MAN19), p.53).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — FDV350\u003c\/h3\u003e\n\u003ch4\u003eWhat do I need to order to complete the FDV350?\u003c\/h4\u003e\u003cp\u003eKingsman lists three parts as required for each unit: the LOGF35 fibre split oak log set with embers, the F35DB black door frame with ceramic glass, and the F350CSS black-frame safety screen. You also need the venting (or the F35BVC B-vent converter) and a 3\/8\" NPT gas supply.\u003c\/p\u003e\n\u003ch4\u003eDoes the FDV350 need framing or a hearth?\u003c\/h4\u003e\u003cp\u003eNo framing is needed; it is a freestanding stove. In an alcove the space must be at least 30\" deep, 55-1\/2\" high and 52-1\/2\" wide. It can sit directly on carpet, tile or other combustible flooring; a hearth is recommended over luxury vinyl. Clearances are 36\" in front, 12\" at the sides, 3\" at the back and 3\" in a 45° corner.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt is direct vent from a 4\"\/7\" collar to an FDVHSQ or FDVHT horizontal, FDVVT40 vertical, or Z47ST24 \/ Z47ST36 snorkel termination. The vertical rise can be up to 40 ft, and the horizontal run up to 20 ft with one 90° elbow and 7 ft of vertical; the shortest setup is 4-1\/2 ft vertical with the stove 4\" from the wall. Each extra 90° elbow takes 36\" off the horizontal run.\u003c\/p\u003e\n\u003ch4\u003eCan it vent into an existing chimney or B-vent?\u003c\/h4\u003e\u003cp\u003eYes, with the F35BVC B-vent converter: 12 ft minimum to 60 ft maximum, with at least 57-1\/4\" to the top of the elbow. A masonry clay-lined chimney needs a liner if it is wider than 5\" inside, and a wood-burning or B-vent chimney if wider than 6\". A stove converted to B-vent cannot be installed in a mobile home.\u003c\/p\u003e\n\u003ch4\u003eCan the FDV350 be converted between natural gas and propane?\u003c\/h4\u003e\u003cp\u003eYes, with Kingsman kits 350DV-CKLP \/ -CKNG (millivolt) or 350DV-CKLPI \/ -CKNGI \/ -CKLPI2 \/ -CKNGI2 (IPI), installed by a qualified agency. Input is 37,000 \/ 29,000 BTU\/h on natural gas and 35,000 \/ 27,000 BTU\/h on propane (max\/min).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in an outage; the optional fan does not run on battery.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912046678178,"sku":"FDV350N","price":2741.03,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912046710946,"sku":"FDV350LP","price":2837.63,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI Proflame 2 with Remote","offer_id":50912046743714,"sku":"FDV350NE2","price":4231.08,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI Proflame 2 with Remote","offer_id":50912046776482,"sku":"FDV350LPE2","price":4328.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/kingsman-fdv350-front.jpg?v=1795271565"},{"product_id":"kingsman-fdv451-direct-vent-gas-stove-fdv451","title":"Kingsman FDV451 Direct Vent Gas Stove FDV451","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman FDV451 is a freestanding direct vent gas stove with a traditional cast-stove look in charcoal with flat black posts. It brings real stove character to living rooms, cottages, basements and additions with no chimney, and it is approved for bedrooms, bed-sitting rooms and, as a direct vent stove, mobile homes.\u003c\/p\u003e\u003cp\u003eA dual burner lights a realistic fire on the LOGF451 five-piece cast split oak log set over lava rock and embers, or on bronze glass with optional RBCB1 cannonballs. Inside, choose an F451RLT traditional or F451RLH herringbone brick liner or an F451PL reflective porcelain liner; the F450FBL door front and F451SDSBL side doors complete the body.\u003c\/p\u003e\u003cp\u003eInput is 34,500 BTU\/h on natural gas and 31,000 BTU\/h on propane, with Hi\/Lo flame and heat adjustment and a fireplace efficiency of up to 67.72% (NG) and 74.06% (LP). A millivolt valve needs no house power and IPI ignition has battery backup, so it keeps heating in a power outage; E2 models include a Proflame 2 remote. It vents through the wall or roof from a 4\"\/7\" collar, or into an existing chimney or B-vent with the F35BVC converter.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFreestanding direct vent stove\u003c\/strong\u003e: sealed combustion; outside air for the fire.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMillivolt or IPI valve\u003c\/strong\u003e: operates during a power failure with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (E2 models)\u003c\/strong\u003e: flame, fan, thermostat and smart thermostat control, with battery backup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual burner\u003c\/strong\u003e: with a realistic flame pattern.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-radiating ceramic glass\u003c\/strong\u003e: Robax or coated Neoceram, 5 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLog set\u003c\/strong\u003e: LOGF451 oak log set (or bronze glass \/ cannonballs with the media kit).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: supplied with the F450FBL door front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 34,500 \/ 23,750 BTU\/h natural gas; 31,000 \/ 24,500 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 65.89% MV \/ 67.72% IPI (NG); 72.14% \/ 74.06% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: mobile home approved (direct vent only); bedroom and bed-sitting room approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: F45FK heat activated with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall thermostat (optional)\u003c\/strong\u003e: Z2MT millivolt or Z80PT programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional, millivolt)\u003c\/strong\u003e: on\/off, thermostatic, thermostatic modulating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLog grate (optional)\u003c\/strong\u003e: F45LG.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBronze glass media (optional, in place of logs)\u003c\/strong\u003e: Z5GC (3 bags) or MQG5C, 15 lb maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-coloured cannonballs (optional)\u003c\/strong\u003e: RBCB1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTraditional brick liner (optional)\u003c\/strong\u003e: F451RLT.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHerringbone brick liner (optional)\u003c\/strong\u003e: F451RLH.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorcelain reflective liner (optional)\u003c\/strong\u003e: F451PL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharcoal door face and vent lid (required, sold separately)\u003c\/strong\u003e: F450FBL, with flat black posts and safety screen; the vent lid must be installed before venting (manual p.18).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharcoal solid-panel side doors (required, sold separately)\u003c\/strong\u003e: F451SDSBL; side doors are listed as required for each unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDecorative black 7\" collar (optional)\u003c\/strong\u003e: F7DBC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDecorative black wall trim plate (optional)\u003c\/strong\u003e: F7DTP.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB-vent adapter (optional)\u003c\/strong\u003e: F35BVC converts the stove to an existing 4\" B-vent or lined chimney.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: kits 450DV-CKNG \/ -CKLP (millivolt) and -CKNGI \/ -CKNG2 \/ -CKLPI \/ -CKLP2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eFDV451N \/ FDV451LP (millivolt); FDV451NE2 \/ FDV451LPE2 (IPI Proflame 2 with remote)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eFreestanding direct vent gas stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eNone required (freestanding). Alcove installation: at least 48\" deep, 71-1\/2\" high and 58\" wide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eFront 36\"; sides 15-1\/2\"; back 2-1\/2\"; ceiling 71-1\/2\" from the floor; top of a 90° elbow 2\"; top of horizontal pipe 1\"; vertical venting 1\". Floor: may sit directly on carpet, tile or other combustible flooring with no added floor protection; a hearth is recommended over vinyl flooring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e34,500 \/ 23,750 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e31,000 \/ 24,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e65.89% MV \/ 67.72% IPI (NG); 72.14% \/ 74.06% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic, 5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eDirect vent, 4\"\/7\" flue collar. Rigid DuraVent DirectVent Pro 4\" x 6-5\/8\" pipe with the Kingsman ZDVDKA stove adapter (horizontal or vertical termination); optional 4\" B-vent with F35BVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eMillivolt or IPI Proflame 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eStove with dual burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eCeramic glass (5 mm Robax or coated Neoceram)\u003c\/li\u003e\n\u003cli\u003eLava rock and embers (supplied with the base unit)\u003c\/li\u003e\n\u003cli\u003eProflame 2 remote (FDV451NE2 \/ FDV451LPE2 only)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLOGF451 five-piece cast split oak log set (listed as required for each unit), or bronze glass media in its place: Z5GC (3 bags) or MQG5C, 15 lb maximum; RBCB1 cannonballs are used with 15 lb of glass\u003c\/li\u003e\n\u003cli\u003eF450FBL door front, charcoal with flat black posts: door face with safety screen and vent lid (required for each unit; the vent lid must be in place before the venting is connected)\u003c\/li\u003e\n\u003cli\u003eF451SDSBL side doors, flat black frame with charcoal solid panel (side doors are listed as required for each unit)\u003c\/li\u003e\n\u003cli\u003eDirect vent pipe from the 4\"\/7\" collar: Kingsman (Z-Flex) venting components labelled for this stove, or DuraVent DirectVent Pro \/ DirectVent Pro Concentric Flex; BDM Pro Form, Ameri-Vent, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp are also approved\u003c\/li\u003e\n\u003cli\u003eZDVDKA DuraVent hard-pipe stove adapter (required with rigid DuraVent pipe)\u003c\/li\u003e\n\u003cli\u003eOne termination: FDVHSQ or FDVHT horizontal, Z47ST24 \/ Z47ST36 snorkel, or FDVVT40 \/ Z47VT vertical\u003c\/li\u003e\n\u003cli\u003eVertical installs: ZDVFS firestop spacer (required through floors and ceilings), ZDVAIS attic insulation shield (required through attic space), ZDV7SC storm collar and a ZDVAAF, ZDVAF2 or ZDVAF3 roof flashing\u003c\/li\u003e\n\u003cli\u003eOr, instead of direct vent pipe: F35BVC B-vent converter into an existing 4\" B-vent or lined chimney, 12 ft minimum to 60 ft maximum (direct vent models only are mobile home approved)\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan or IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eF45LG log grate\u003c\/li\u003e\n\u003cli\u003eF451RLT traditional brick liner\u003c\/li\u003e\n\u003cli\u003eF451RLH herringbone brick liner\u003c\/li\u003e\n\u003cli\u003eF451PL reflective porcelain liner (one back and two side panels)\u003c\/li\u003e\n\u003cli\u003eRBCB1 multi-coloured cannonballs\u003c\/li\u003e\n\u003cli\u003eF45FK fan kit with variable speed control\u003c\/li\u003e\n\u003cli\u003eF7DBC decorative black collar, 7\"\u003c\/li\u003e\n\u003cli\u003eFV7FBT decorative brass collar, 7\"\u003c\/li\u003e\n\u003cli\u003eF7DTP decorative black wall trim plate\u003c\/li\u003e\n\u003cli\u003eZ2MT millivolt wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable digital millivolt wall thermostat\u003c\/li\u003e\n\u003cli\u003eGFRC on\/off remote (millivolt \/ IPI)\u003c\/li\u003e\n\u003cli\u003eGTRC thermostat remote (millivolt)\u003c\/li\u003e\n\u003cli\u003eGTMRCN \/ GTMRCP thermostat \/ modulating remote, natural gas \/ propane (millivolt)\u003c\/li\u003e\n\u003cli\u003eGTFRCN \/ GTFRCP thermostat \/ modulating remote with fan control (millivolt)\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI models)\u003c\/li\u003e\n\u003cli\u003eZDVSSLR vinyl siding shield\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/451-MAN19-3.pdf\"\u003eFDV451 installation and operating manual (451-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/12\/21382-KM-B087-FDV451ENG-Dec2025-FNL1-Web.pdf\"\u003eFDV451 brochure and specifications (Dec 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (FDV451 installation and operating manual (451-MAN19), safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.2–8)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eMobile home approved (direct vent only; not when converted to B-vent); approved for bedrooms and bed-sitting rooms.\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eLocation, clearances and floor (pp.9–10)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eClearances: front 36\", sides 15-1\/2\", back 2-1\/2\"; ceiling 71-1\/2\" from the floor; top of a 90° elbow 2\"; horizontal pipe top 1\"; vertical vent 1\" (p.9).\u003c\/li\u003e\n\u003cli\u003eAlcove: at least 48\" deep, 71-1\/2\" high and 58\" wide (p.9).\u003c\/li\u003e\n\u003cli\u003eInstall on a hard, stable surface; carpet and tile are fine, a hearth is recommended over vinyl.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAccessories, liners and logs (pp.11–23)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eF45FK fan: variable speed control, needs a grounded 120 VAC receptacle.\u003c\/li\u003e\n\u003cli\u003eLog set: LOGF451 oak log set (or bronze glass \/ cannonballs with the media kit); follow the placement diagram and keep the pilot clear.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm Robax or coated Neoceram; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas, maintenance and conversion (pp.38–44)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.10).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.10).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.10).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.10). Field conversion between natural gas and propane uses Kingsman kits 450DV-CKNG \/ -CKLP (millivolt) and -CKNGI \/ -CKNG2 \/ -CKLPI \/ -CKLP2 (IPI), installed by a qualified agency (pp.41–43).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and ignition (pp.24–25, 36–37, 45–59)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.24–25, 36–37, 45–59).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.60–70)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVenting: Direct vent, 4\"\/7\" flue collar. Rigid DuraVent DirectVent Pro 4\" x 6-5\/8\" pipe with the Kingsman ZDVDKA stove adapter (horizontal or vertical termination); optional 4\" B-vent with F35BVC.\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 4-1\/2 ft (stove 2-1\/2\" from the wall); maximum vertical 45 ft; maximum horizontal 20 ft with one 90° elbow and 7 ft of vertical; 1\/4\" rise per 12\" of run.\u003c\/li\u003e\n\u003cli\u003eEach extra 90° elbow takes 36\" off the horizontal run and each 45° takes 18\"; propane horizontal runs need 1 ft more vertical rise.\u003c\/li\u003e\n\u003cli\u003eB-vent conversion with F35BVC into an existing 4\" B-vent or lined chimney, 12–60 ft.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.8).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.7).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (FDV451 installation and operating manual (451-MAN19), p.76).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — FDV451\u003c\/h3\u003e\n\u003ch4\u003eWhat do I need to order to complete the FDV451?\u003c\/h4\u003e\u003cp\u003eKingsman lists the door front, side doors and log set as required for each unit: the F450FBL charcoal door front (with safety screen and vent lid), F451SDSBL side doors, and the LOGF451 log set (or bronze glass media in its place). You also need the venting, or the F35BVC B-vent converter, and a 3\/8\" NPT gas supply.\u003c\/p\u003e\n\u003ch4\u003eDoes the FDV451 need framing or a hearth?\u003c\/h4\u003e\u003cp\u003eNo framing is needed; it is a freestanding stove. Clearances are 36\" in front, 15-1\/2\" at the sides and 2-1\/2\" at the back, with the ceiling at least 71-1\/2\" above the floor. In an alcove the space must be 48\" deep, 71-1\/2\" high and 58\" wide. It can sit directly on carpet, tile or other combustible flooring; a hearth is recommended over vinyl.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt is direct vent from a 4\"\/7\" collar to an FDVHSQ or FDVHT horizontal, Z47ST24 \/ Z47ST36 snorkel, or FDVVT40 \/ Z47VT vertical termination. The vertical rise can be up to 45 ft, and the horizontal run up to 20 ft with one 90° elbow and 7 ft of vertical; the shortest setup is 4-1\/2 ft vertical with the stove 2-1\/2\" from the wall. Each extra 90° elbow takes 36\" off the horizontal run.\u003c\/p\u003e\n\u003ch4\u003eCan it vent into an existing chimney or B-vent?\u003c\/h4\u003e\u003cp\u003eYes, with the F35BVC B-vent converter, installed vertically: 12 ft minimum to 60 ft maximum, with at least 57-1\/4\" to the top of the elbow. A masonry clay-lined chimney needs a liner if it is wider than 5\" inside, and a wood-burning or B-vent chimney if wider than 6\". The chimney must not vent any other appliance, and only the direct vent version is mobile home approved.\u003c\/p\u003e\n\u003ch4\u003eCan the FDV451 be converted between natural gas and propane?\u003c\/h4\u003e\u003cp\u003eYes, with Kingsman kits 450DV-CKNG \/ -CKLP (millivolt) or -CKNGI \/ -CKNG2 \/ -CKLPI \/ -CKLP2 (IPI), installed by a qualified agency. Input is 34,500 \/ 23,750 BTU\/h on natural gas and 31,000 \/ 24,500 BTU\/h on propane (max\/min).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in an outage; the optional fan does not run on battery.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912046809250,"sku":"FDV451N","price":2621.48,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912046842018,"sku":"FDV451LP","price":2716.88,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI Proflame 2 with Remote","offer_id":50912046874786,"sku":"FDV451NE2","price":4105.5,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI Proflame 2 with Remote","offer_id":50912046907554,"sku":"FDV451LPE2","price":4203.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/FDV451-1.jpg?v=1795037981"},{"product_id":"kingsman-zcv3622-36-direct-vent-gas-fireplace-zcv3622","title":"Kingsman ZCV3622 36\" Direct Vent Gas Fireplace ZCV3622","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman ZCV3622 is a 36-inch zero-clearance direct vent gas fireplace with a traditional oak log fire, sized for bedrooms, dens, basements and smaller living rooms. It is certified for bedrooms and bed-sitting rooms and approved for manufactured homes, and it is the traditional sister of the ZCVRB3622: the same compact body, with logs instead of glass media.\u003c\/p\u003e\u003cp\u003eThe 29-3\/4\" W x 18-5\/8\" H tempered glass front shows a realistic burn across the LOGC51 five-piece oak log set (sold separately) on Kingsman's proprietary burner, framed by a porcelain reflective or metal brick liner. Input is 18,000 BTU\/h on natural gas or propane with Hi\/Lo adjustment, at a fireplace efficiency of 60.54% MV \/ 63.46% IPI (NG) and 62.09% \/ 65.09% (LP), which makes it useful zone heat for its size.\u003c\/p\u003e\u003cp\u003eA Hi\/Lo millivolt valve (no power needed) or IPI ignition with battery backup both keep the fire running in a power failure. It vents 4\"\/7\" through the wall or roof, through a 3\"\/3\" co-linear liner into an existing chimney, or with a PVH58 power vent. Wall thermostats, Proflame remotes and the Z36FK fan kit are available.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact zero-clearance direct vent\u003c\/strong\u003e: 0\" to the back, sides, floor and top standoffs; 36\" in front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt or IPI valve\u003c\/strong\u003e: works during power failures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProprietary burner\u003c\/strong\u003e: realistic burn.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: mobile home, bedroom and bed-sitting room approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTempered glass\u003c\/strong\u003e: 29-3\/4\" W x 18-5\/8\" H viewing area.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 18,000 \/ 13,000 BTU\/h natural gas; 18,000 \/ 15,000 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 60.54% MV \/ 63.46% IPI (NG); 62.09% \/ 65.09% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLOGC51 oak log set\u003c\/strong\u003e: the flame display for this model (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounds (optional)\u003c\/strong\u003e: ZCV36S1BL hearth-mount black surround (covers 39\" W x 34-1\/16\" H framing); ZCV36SWFBL flat black surround (covers 40-7\/8\" W x 37-1\/4\" H).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z36FK heat activated with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall thermostat (optional)\u003c\/strong\u003e: standard on\/off or programmable 5-day\/2-day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional)\u003c\/strong\u003e: on\/off, thermostat on\/off, thermostatic modulating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: ZCV3622PRL porcelain reflective liner; ZCV3622ML metal brick liner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH for IPI backup batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVenting flexibility\u003c\/strong\u003e: 4\"\/7\" flex or rigid, 3\"\/3\" co-linear, or PVH58 power vent.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eZCV3622N \/ ZCV3622LP (millivolt); ZCV3622NE \/ ZCV3622LPE (IPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eZero-clearance direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e36\" W x 37-1\/8\" H x 17-7\/16\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eRough-opening width and depth are not published by the manufacturer as labeled values. Framing runs flush to the standoffs at 0\" (back, sides and top); add 1\/2\" to the framing depth when framing flush with the face of the fireplace (p.13); ceiling at least 60\" above the bottom of the fireplace with the flue restrictor in, 46-1\/2\" with it removed (pp.15–16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e29-3\/4\" W x 18-5\/8\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eFront 36\"; back, sides, floor and top standoffs 0\"; ceiling at least 60\" above the bottom of the fireplace with the flue restrictor installed (46-1\/2\" with it removed); top of a 90° bend 2-1\/2\" in a 60\" enclosure (10\" with the restrictor removed at 46-1\/2\" and above, reducing 1\" for every 2\" of extra height to 2\" at 62-1\/2\"); horizontal pipe 1-1\/2\" top, 1\" sides and bottom; vertical pipe 1\" (pp.15–16); facing: combustibles up to the fireplace edge only, face covering non-combustible, combustible hearth no more than 3\" high (p.17); mantels: combustible mantel minimum height not published by the manufacturer in text form; a non-combustible mantel may extend right up to the tile lip (p.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e18,000 \/ 13,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e18,000 \/ 15,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e60.54% MV \/ 63.46% IPI (NG); 62.09% \/ 65.09% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eTempered 5 mm, with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e4\"\/7\" flex or 4\" x 6-5\/8\" rigid; 3\"\/3\" co-linear; PVH58 power vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFloor: no hearth is required; vinyl flooring needs a 12\" hearth or a 24\" raise; carpet needs a metal or wood panel (pp.12–15).\u003c\/li\u003e\n\u003cli\u003eAppliance weight: not listed in the manual text.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eTempered glass front\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLOGC51 oak log set (the flame display Kingsman lists for this model)\u003c\/li\u003e\n\u003cli\u003e4\"\/7\" direct vent pipe and termination (or a 3\"\/3\" co-linear kit or PVH58 power vent)\u003c\/li\u003e\n\u003cli\u003eNon-combustible face covering\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan or IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZCV36S1BL hearth-mount black surround (covers 39\" W x 34-1\/16\" H framing)\u003c\/li\u003e\n\u003cli\u003eZCV36SWFBL flat black surround (covers 40-7\/8\" W x 37-1\/4\" H)\u003c\/li\u003e\n\u003cli\u003eZCV3622PRL porcelain reflective liner\u003c\/li\u003e\n\u003cli\u003eZCV3622ML metal brick liner\u003c\/li\u003e\n\u003cli\u003eZ36FK fan kit\u003c\/li\u003e\n\u003cli\u003eZ2MT wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eProflame remotes (GT \/ EGT series)\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder\u003c\/li\u003e\n\u003cli\u003ePVH58 power vent\u003c\/li\u003e\n\u003cli\u003ePVH58FM flush-mount power vent\u003c\/li\u003e\n\u003cli\u003eZDVDFA DuraVent\/ICC adapter for rigid pipe\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/36ZCV-MAN19-5.pdf\"\u003eZCV3622\/ZCVRB3622 installation and operating manual (36ZCV-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2017\/03\/19717-KM-B089-ZCV3622ENG-June2024-FNL1-Web.pdf\"\u003eZCV3622 brochure and specifications (June 2024)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (ZCV3622\/ZCVRB3622 installation and operating manual (36ZCV-MAN19), safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.2–5)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for bedrooms, bed-sitting rooms and manufactured\/mobile homes where local codes allow.\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.4).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation, framing and clearances (pp.6–18)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFront 36\"; 0\" at the back, sides, floor and top standoffs; ceiling 60\" (restrictor in) or 46-1\/2\" (restrictor out) above the bottom of the fireplace.\u003c\/li\u003e\n\u003cli\u003eThe factory flue restrictor (above ZCV3622 serial #2016 \/ ZCVRB3622 #10674) must be removed for the low 33\" enclosure (p.16).\u003c\/li\u003e\n\u003cli\u003eNo hearth required; island top-vent horizontal runs up to 20 ft (p.14).\u003c\/li\u003e\n\u003cli\u003eFace covering non-combustible; combustible hearth no more than 3\" high (p.17).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAccessories, liners and media (pp.19–38)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSurrounds, liners, Z36FK fan (speed control may mount outside the firebox) and the LOGC51 log set install per the accessory pages.\u003c\/li\u003e\n\u003cli\u003eReplacement glass: 5 mm tempered, sealed with silicone rated to 500°F.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.39–49)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.39).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.39).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.39).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.39). Field conversion between natural gas and propane uses Kingsman kits 3622-CKNG \/ -CKLP \/ -CKNGI \/ -CKLPI (and RB equivalents), installed by a qualified agency (pp.44–49).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eIPI controls (pp.50–60)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.50–60).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.61–70)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: Kingsman 4\"\/7\" flex, listed 4\" x 6-5\/8\" rigid, 3\"\/3\" co-linear (12 ft minimum) or PVH58 \/ PVH58FM power vent.\u003c\/li\u003e\n\u003cli\u003eMaximum vertical 43 ft; maximum horizontal 20 ft with a 7 ft vertical; 1\/4\" rise per 12\" of run.\u003c\/li\u003e\n\u003cli\u003eUp to two 45° bends (18\" each) plus two more 90° bends (36\" each); remove the restrictor for runs under 15 ft.\u003c\/li\u003e\n\u003cli\u003ePower venting: up to 125 ft; downward runs are not allowed on millivolt models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.3).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.3).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.5).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.4).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.4).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (ZCV3622\/ZCVRB3622 installation and operating manual (36ZCV-MAN19), p.77).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — ZCV3622\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the ZCV3622 need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: framing runs flush to the standoffs with 0\" at the back, sides and top, and 0\" to the floor, with 36\" clear in front. The unit measures 36\" W × 37-1\/8\" H × 17-7\/16\" D; add 1\/2\" to the framing depth when framing flush with the face. The ceiling must be at least 60\" above the bottom of the fireplace, or 46-1\/2\" with the flue restrictor removed. No hearth is required.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 4\"\/7\" direct vent pipe (Kingsman Z-Flex flex, or 4\" x 6-5\/8\" rigid pipe with the ZDVDFA adapter), a 3\"\/3\" co-linear liner into an existing chimney (12 ft minimum, 43 ft maximum) or a PVH58 power vent (up to 125 ft). Direct vent runs go up to 43 ft vertical; horizontal runs go up to 20 ft with 7 to 20 ft of vertical, and are shorter outside that range (8 ft at 5 ft of vertical, 12 ft at 6 ft, 15 ft at 25 ft, 10 ft at 30 ft), rising 1\/4\" per foot. Propane installations need an extra 1 ft of vertical rise before going horizontal.\u003c\/p\u003e\n\u003ch4\u003eCan the ZCV3622 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It is sold in natural gas (ZCV3622N) and propane (ZCV3622LP) versions, rated 18,000 \/ 13,000 BTU\/h and 18,000 \/ 15,000 BTU\/h (max\/min). Field conversion between the two uses Kingsman kits 3622-CKNG \/ -CKLP \/ -CKNGI \/ -CKLPI.\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models keep the fire running on a battery backup; the fan does not run on battery.\u003c\/p\u003e\n\u003ch4\u003eIs a log set included?\u003c\/h4\u003e\u003cp\u003eNo. The LOGC51 five-piece oak log set is sold separately. Kingsman also lists the MQLOGC22 log set, the MQLOGC23 four-piece driftwood set and the MQRSP5 rock platform for this model.\u003c\/p\u003e\n\u003ch4\u003eCan it be installed in a bedroom?\u003c\/h4\u003e\u003cp\u003eYes. It is certified for installation in a bedroom or bed-sitting room; in Canada it must be installed with a listed millivolt thermostat. It is also approved for manufactured\/mobile homes where local codes allow.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas","offer_id":50912048513186,"sku":"ZCV3622N","price":2224.22,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50912048545954,"sku":"ZCV3622LP","price":2320.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/ZCV3622-1-1.jpg?v=1795038035"},{"product_id":"kingsman-zcvrb3622-36-linear-gas-fireplace-zcvrb3622","title":"Kingsman ZCVRB3622 36\" Linear Gas Fireplace ZCVRB3622","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman ZCVRB3622 is a 36-inch zero-clearance direct vent gas fireplace with a linear-style burner and glass media, sized for bedrooms, dens, basements and smaller living rooms. It is certified for bedrooms and bed-sitting rooms and approved for manufactured homes, and it is the contemporary sister of the ZCV3622: the same compact body, with bronze glass media instead of logs.\u003c\/p\u003e\u003cp\u003eThe 29-3\/4\" W x 16-1\/8\" H low-E tempered glass front shows a modern, ribbon-like flame over the decorative bronze ember glass that comes with it, with a porcelain reflective liner and the ULK2 two-lamp light kit available for depth and glow. Input is 17,500 BTU\/h on natural gas or propane with Hi\/Lo adjustment, at a fireplace efficiency of 61.36% MV \/ 65.82% IPI (NG) and 62.72% \/ 64.55% (LP), which makes it useful zone heat for its size.\u003c\/p\u003e\u003cp\u003eA Hi\/Lo millivolt valve (no power needed) or IPI ignition with battery backup both keep the fire running in a power failure. It vents 4\"\/7\" through the wall or roof, through a 3\"\/3\" co-linear liner into an existing chimney, or with a PVH58 power vent. Wall thermostats, Proflame remotes and the Z36FK fan kit are available.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact zero-clearance direct vent\u003c\/strong\u003e: 0\" to the back, sides, floor and top standoffs; 36\" in front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt or IPI valve\u003c\/strong\u003e: works during power failures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDecorative bronze ember glass\u003c\/strong\u003e: included with the fireplace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: mobile home, bedroom and bed-sitting room approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-E tempered glass\u003c\/strong\u003e: 29-3\/4\" W x 16-1\/8\" H viewing area.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 17,500 \/ 12,000 BTU\/h natural gas; 17,500 \/ 14,000 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 61.36% MV \/ 65.82% IPI (NG); 62.72% \/ 64.55% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounds (optional)\u003c\/strong\u003e: ZCVRB36SBL black surround trim kit (covers 36\" W x 22-1\/2\" H); ZCVRB36SSS stainless steel surround trim kit; ZCVRB36SWFBL flat black surround.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z36FK heat activated with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall thermostat (optional)\u003c\/strong\u003e: standard on\/off or programmable 5-day\/2-day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional)\u003c\/strong\u003e: on\/off, thermostat on\/off, thermostatic modulating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: Z3622PRL porcelain reflective liner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal light kit (optional)\u003c\/strong\u003e: ULK2 two-lamp universal light kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH for IPI backup batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVenting flexibility\u003c\/strong\u003e: 4\"\/7\" flex or rigid, 3\"\/3\" co-linear, or PVH58 power vent.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eZCVRB3622N \/ ZCVRB3622LP (millivolt); ZCVRB3622NE \/ ZCVRB3622LPE (IPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eZero-clearance direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e36\" W x 37-1\/8\" H x 17-7\/16\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eRough-opening width and depth are not published by the manufacturer as labeled values. Framing runs flush to the standoffs at 0\" (back, sides and top); add 1\/2\" to the framing depth when framing flush with the face of the fireplace (p.13); ceiling at least 60\" above the bottom of the fireplace with the flue restrictor in, 46-1\/2\" with it removed (pp.15–16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e29-3\/4\" W x 16-1\/8\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eFront 36\"; back, sides, floor and top standoffs 0\"; ceiling at least 60\" above the bottom of the fireplace with the flue restrictor installed (46-1\/2\" with it removed); top of a 90° bend 2-1\/2\" in a 60\" enclosure (10\" with the restrictor removed at 46-1\/2\" and above, reducing 1\" for every 2\" of extra height to 2\" at 62-1\/2\"); horizontal pipe 1-1\/2\" top, 1\" sides and bottom; vertical pipe 1\" (pp.15–16); facing: combustibles up to the fireplace edge only, face covering non-combustible, combustible hearth no more than 3\" high (p.17); mantels: combustible mantel minimum height not published by the manufacturer in text form; a non-combustible mantel may extend right up to the tile lip (p.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e17,500 \/ 12,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e17,500 \/ 14,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e61.36% MV \/ 65.82% IPI (NG); 62.72% \/ 64.55% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eLow-E tempered 5 mm, with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e4\"\/7\" flex or 4\" x 6-5\/8\" rigid; 3\"\/3\" co-linear; PVH58 power vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFloor: no hearth is required; vinyl flooring needs a 12\" hearth or a 24\" raise; carpet needs a metal or wood panel (pp.12–15).\u003c\/li\u003e\n\u003cli\u003eAppliance weight: not listed in the manual text.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eLow-E tempered glass front\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier\u003c\/li\u003e\n\u003cli\u003eDecorative bronze ember glass\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4\"\/7\" direct vent pipe and termination (or a 3\"\/3\" co-linear kit or PVH58 power vent)\u003c\/li\u003e\n\u003cli\u003eNon-combustible face covering\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan or IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZCVRB36SBL black surround trim kit (covers 36\" W x 22-1\/2\" H)\u003c\/li\u003e\n\u003cli\u003eZCVRB36SSS stainless steel surround trim kit\u003c\/li\u003e\n\u003cli\u003eZCVRB36SWFBL flat black surround\u003c\/li\u003e\n\u003cli\u003eZ3622PRL porcelain reflective liner\u003c\/li\u003e\n\u003cli\u003eRBCB1 multi-coloured cannonballs\u003c\/li\u003e\n\u003cli\u003eULK2 light kit\u003c\/li\u003e\n\u003cli\u003eZ36FK fan kit\u003c\/li\u003e\n\u003cli\u003eZ2MT wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eProflame remotes (GT \/ EGT series)\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder\u003c\/li\u003e\n\u003cli\u003ePVH58 power vent\u003c\/li\u003e\n\u003cli\u003ePVH58FM flush-mount power vent\u003c\/li\u003e\n\u003cli\u003eZDVDFA DuraVent\/ICC adapter for rigid pipe\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/36ZCV-MAN19-4.pdf\"\u003eZCV3622\/ZCVRB3622 installation and operating manual (36ZCV-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2017\/03\/19717-KM-B091-ZCVRB3622ENG-June2024-FNL1-Web.pdf\"\u003eZCVRB3622 brochure and specifications (June 2024)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (ZCV3622\/ZCVRB3622 installation and operating manual (36ZCV-MAN19), safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.2–5)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for bedrooms, bed-sitting rooms and manufactured\/mobile homes where local codes allow.\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.4).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation, framing and clearances (pp.6–18)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFront 36\"; 0\" at the back, sides, floor and top standoffs; ceiling 60\" (restrictor in) or 46-1\/2\" (restrictor out) above the bottom of the fireplace.\u003c\/li\u003e\n\u003cli\u003eThe factory flue restrictor (above ZCV3622 serial #2016 \/ ZCVRB3622 #10674) must be removed for the low 33\" enclosure (p.16).\u003c\/li\u003e\n\u003cli\u003eNo hearth required; island top-vent horizontal runs up to 20 ft (p.14).\u003c\/li\u003e\n\u003cli\u003eFace covering non-combustible; combustible hearth no more than 3\" high (p.17).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAccessories, liners and media (pp.19–38)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSurrounds, liners, Z36FK fan (speed control may mount outside the firebox) and the ULK2 light kit install per the accessory pages.\u003c\/li\u003e\n\u003cli\u003eReplacement glass: 5 mm low-e tempered, sealed with silicone rated to 500°F.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.39–49)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.39).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.39).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.39).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.39). Field conversion between natural gas and propane uses Kingsman kits 3622-CKNG \/ -CKLP \/ -CKNGI \/ -CKLPI (and RB equivalents), installed by a qualified agency (pp.44–49).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eIPI controls (pp.50–60)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.50–60).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.61–70)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: Kingsman 4\"\/7\" flex, listed 4\" x 6-5\/8\" rigid, 3\"\/3\" co-linear (12 ft minimum) or PVH58 \/ PVH58FM power vent.\u003c\/li\u003e\n\u003cli\u003eMaximum vertical 43 ft; maximum horizontal 20 ft with a 7 ft vertical; 1\/4\" rise per 12\" of run.\u003c\/li\u003e\n\u003cli\u003eUp to two 45° bends (18\" each) plus two more 90° bends (36\" each); remove the restrictor for runs under 15 ft.\u003c\/li\u003e\n\u003cli\u003ePower venting: up to 125 ft; downward runs are not allowed on millivolt models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.3).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.3).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.5).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.4).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.4).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (ZCV3622\/ZCVRB3622 installation and operating manual (36ZCV-MAN19), p.77).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — ZCVRB3622\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the ZCVRB3622 need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: framing runs flush to the standoffs with 0\" at the back, sides and top, and 0\" to the floor, with 36\" clear in front. The unit measures 36\" W × 37-1\/8\" H × 17-7\/16\" D; add 1\/2\" to the framing depth when framing flush with the face. The ceiling must be at least 60\" above the bottom of the fireplace, or 46-1\/2\" with the flue restrictor removed. No hearth is required.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 4\"\/7\" direct vent pipe (Kingsman Z-Flex flex, or 4\" x 6-5\/8\" rigid pipe with the ZDVDFA adapter), a 3\"\/3\" co-linear liner into an existing chimney (12 ft minimum, 43 ft maximum) or a PVH58 power vent (up to 125 ft). Direct vent runs go up to 43 ft vertical; horizontal runs go up to 20 ft with 7 to 20 ft of vertical, and are shorter outside that range (8 ft at 5 ft of vertical, 12 ft at 6 ft, 15 ft at 25 ft, 10 ft at 30 ft), rising 1\/4\" per foot. Propane installations need an extra 1 ft of vertical rise before going horizontal.\u003c\/p\u003e\n\u003ch4\u003eCan the ZCVRB3622 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It is sold in natural gas (ZCVRB3622N) and propane (ZCVRB3622LP) versions, rated 17,500 \/ 12,000 BTU\/h and 17,500 \/ 14,000 BTU\/h (max\/min).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models keep the fire running on a battery backup; the fan and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eIs the glass media included?\u003c\/h4\u003e\u003cp\u003eYes. Decorative bronze ember glass comes with the fireplace. Kingsman requires ember glass media on this burner: 1\/2\" Ember Glass from American Fireglass or Liquid Glass from Firegear, up to 5 lb, kept off the burner tube and pilot area.\u003c\/p\u003e\n\u003ch4\u003eCan it be installed in a bedroom?\u003c\/h4\u003e\u003cp\u003eYes. It is certified for installation in a bedroom or bed-sitting room; in Canada it must be installed with a listed millivolt thermostat. It is also approved for manufactured\/mobile homes where local codes allow.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas","offer_id":50912048578722,"sku":"ZCVRB3622N","price":2415.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50912048611490,"sku":"ZCVRB3622LP","price":2514.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/ZCVRB3622-updates-Jan2020-1-copy.jpg?v=1795038036"},{"product_id":"kingsman-zcvrb47-47-linear-gas-fireplace-zcvrb47","title":"Kingsman ZCVRB47 47\" Linear Gas Fireplace ZCVRB47","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman ZCVRB47 is a 47-inch zero-clearance linear direct vent gas fireplace and the compact size of the ZCVRB family for smaller rooms and tighter walls, with 4\"\/7\" venting like the rest of the Kingsman 4\"\/7\" range. With 0\" clearance at the back, sides and top standoffs, it fits flush-to-wall, corner, island and room-divider layouts and exterior walls.\u003c\/p\u003e\u003cp\u003eA 41-5\/8\" x 15-7\/8\" viewing area shows a long ribbon of flame over the included bronze ember glass. Cannonballs, other glass colours, driftwood, birch or oak linear logs and a porcelain reflective liner change the look. Input is up to 24,500 BTU\/h on natural gas or propane with Hi\/Lo turndown, at a fireplace efficiency of 55.26% MV \/ 57.31% IPI (NG); 55.01% MV \/ 57.10% IPI (LP). It is certified as a vented room heater and approved for bedrooms, bed-sitting rooms and manufactured homes.\u003c\/p\u003e\u003cp\u003eMillivolt models need no house power; IPI models have battery backup and pair with Proflame remotes. It vents 4\"\/7\" through the wall or roof, or with the optional PVH58 power vent. A vented chase (Kingsman's Cool Touch Wall) runs about 40% cooler and lowers the minimum mantel height from 41-7\/16\" to 39-7\/16\", which makes a TV above practical.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear direct vent design\u003c\/strong\u003e: sealed combustion draws outside air and exhausts outdoors through 4\"\/7\" venting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance installation\u003c\/strong\u003e: 0\" to combustibles at the back, sides, floor and top standoffs; 36\" in front (manual pp.18, 26).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt valve\u003c\/strong\u003e: standard on millivolt models; operates during power failures with no electricity needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIPI electronic ignition (optional models)\u003c\/strong\u003e: intermittent pilot ignition with battery backup; a cold-climate (standing pilot) setting is available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDecorative bronze ember glass\u003c\/strong\u003e: included and required: the fireplace must not run without the glass embers on the burner and media tray.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTempered glass front\u003c\/strong\u003e: 41-5\/8\" x 15-7\/8\" viewing area.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included over the glass to reduce the risk of burns from the hot glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 24,500 BTU\/h maximum input on natural gas and propane; Hi\/Lo turndown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 55.26% MV \/ 57.31% IPI (NG); 55.01% MV \/ 57.10% IPI (LP) (Kingsman specification).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: mobile\/manufactured home, bedroom and bed-sitting room approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVented chase option (Cool Touch Wall)\u003c\/strong\u003e: vent the chase with grills or an open top for cooler walls and a lower 39-7\/16\" mantel; minimum free area 105 sq in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure grills (optional)\u003c\/strong\u003e: V46EG front grill (46-3\/4\" x 2-5\/8\" opening, 122 sq in); VL60EGS side grills, pair (two 15-1\/4\" x 6-5\/8\" openings, 220 sq in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurround (optional)\u003c\/strong\u003e: ZCVRB47S1BL black or ZCVRB47S1SS stainless steel, covers 44-1\/2\" W x 18-7\/8\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z46FK heat-activated fan with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal light kit (optional)\u003c\/strong\u003e: ULK2 two-lamp universal light kit (12 VAC halogen) for accent lighting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall thermostat (optional)\u003c\/strong\u003e: standard on\/off or programmable 5-day\/2-day models (Z2MT, Z80PT).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote controls (optional)\u003c\/strong\u003e: on\/off, thermostatic, thermostatic modulating, and thermostatic modulating with fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (IPI PF2 models)\u003c\/strong\u003e: flame-height modulation and multi-colour LED accent lighting control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH puts the IPI backup batteries in an accessible wall box within 16 ft of the valve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiner option\u003c\/strong\u003e: ZCVRB47PL porcelain reflective liner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedia options\u003c\/strong\u003e: RBCB1 multi-coloured cannonballs, alternative glass colours and linear log sets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 or PVH58FM power vent for extended horizontal runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: NG\/LP conversion kits available (46ZRB-CKLP \/ -CKNG (millivolt); 46ZRB-CKLPI \/ -CKNGI and 46VRB-CKLP2 \/ -CKNG2 (IPI)).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19 \/ CSA 2.33-19 vented gas fireplace heater; CSA 2.17-2017 (high altitude).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eZCVRB47N \/ ZCVRB47LP (millivolt); ZCVRB47NE \/ ZCVRB47LPE (IPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eZero-clearance linear direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e46-5\/8\" W x 38-5\/8\" H x 17-3\/4\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eRough-opening width and depth not published by the manufacturer. Framing goes to the fold-out standoffs at 0\" (back, sides and top) and must not extend past them; header height 38-3\/4\", maximum header depth 3-3\/4\"; minimum enclosure height 70\" from the bottom of the fireplace; 52\" minimum framing height for horizontal venting, plus 1\/4\" of rise per foot; no hearth required (manual pp.10, 17–18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e41-5\/8\" W x 15-7\/8\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eFront 36\"; back, sides, floor and top standoffs 0\"; ceiling\/enclosure at least 70\" above the bottom of the fireplace; top of a 90° bend 4\"; top of horizontal pipe 1-1\/2\"; sides and bottom of horizontal pipe 1\"; vertical pipe 1\" (pp.18, 26); mantel at least 41-7\/16\" (unvented chase) or 39-7\/16\" (vented chase) above the bottom of the unit (p.14); TV above only with a vented chase or the recessed option, at least 1\" from the vent grill or opening (pp.14, 25)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e24,500 \/ 16,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e24,500 \/ 20,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e55.26% MV \/ 57.31% IPI (NG); 55.01% MV \/ 57.10% IPI (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eTempered, with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e4\"\/7\" (Kingsman Z-Flex 4\"\/7\" flex or 4\" x 6-5\/8\" rigid direct vent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e120 VAC grounded receptacle for fan \/ IPI adapter; millivolt runs without power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMedia included\u003c\/th\u003e\n\u003ctd\u003eDecorative bronze ember glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum media load\u003c\/th\u003e\n\u003ctd\u003e5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprovals\u003c\/th\u003e\n\u003ctd\u003eBedroom, bed-sitting room, manufactured\/mobile home\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNon-combustible facing (unvented chase): at least 26-7\/8\" x 47\"; recommended 30-15\/16\" x 48-1\/2\" (p.19).\u003c\/li\u003e\n\u003cli\u003eVented chase: minimum enclosure height 70\"; minimum free opening 105 sq in; grills within 2\" of the sealed enclosure top; open top 1-1\/4\" minimum on three sides (pp.13, 21–24).\u003c\/li\u003e\n\u003cli\u003eAppliance weight: not listed in the manual text.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with linear burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eDecorative bronze ember glass\u003c\/li\u003e\n\u003cli\u003eTempered glass front\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier (47ZCVCSS)\u003c\/li\u003e\n\u003cli\u003eNailing tabs (two per side) and standoffs\u003c\/li\u003e\n\u003cli\u003eRemovable lower face panel\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4\"\/7\" direct vent pipe and a matching horizontal or vertical termination (Kingsman Z-Flex or a listed rigid system)\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing over the face of the fireplace in an unvented chase (minimum 26-7\/8\" x 47\")\u003c\/li\u003e\n\u003cli\u003eFor a vented chase: V46EG front grill, VL60EGS side grills, pair, a custom grill, or an open top meeting the minimum free area\u003c\/li\u003e\n\u003cli\u003eGas supply with a manual shutoff valve (3\/8\" NPT inlet; 1\/2\" rigid pipe or an approved flex connector such as FP15GC)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan kit or IPI models (split receptacle installed by an electrician)\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup and remote receiver\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZCVRB47S1BL black surround trim kit\u003c\/li\u003e\n\u003cli\u003eZCVRB47S1SS stainless steel surround trim kit\u003c\/li\u003e\n\u003cli\u003eV47PTLK tile lip kit\u003c\/li\u003e\n\u003cli\u003eZCVRB47PL porcelain reflective panel liner\u003c\/li\u003e\n\u003cli\u003eRBCB1 multi-coloured cannonballs\u003c\/li\u003e\n\u003cli\u003eZ46FK fan kit with variable speed control\u003c\/li\u003e\n\u003cli\u003eULK2 universal light kit\u003c\/li\u003e\n\u003cli\u003eZ2MT digital wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eGTRC millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eEGTRC IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCN IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCP IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCN IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCP IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI)\u003c\/li\u003e\n\u003cli\u003ePVH58 power vent\u003c\/li\u003e\n\u003cli\u003ePVH58FM flush-mount power vent\u003c\/li\u003e\n\u003cli\u003ePVC58MV power vent control module\u003c\/li\u003e\n\u003cli\u003ePVC58IPI power vent control module\u003c\/li\u003e\n\u003cli\u003eV46EG front grill (vented chase)\u003c\/li\u003e\n\u003cli\u003eVL60EGS side grills, pair (vented chase)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/47ZCV-MAN19-11.pdf\"\u003eZCVRB47 installation and operating manual (47ZCV-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/07\/21056-KM-B102-ZCVRB47-60-72ENG-July2025-FNL1-Web.pdf\"\u003eZCVRB47\/60\/72 brochure and specifications (July 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (ZCVRB47 installation and operating manual (47ZCV-MAN19), cover and pp.5–7). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.4–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19 and CSA 2.33-19 as a vented gas fireplace heater (cover). It is not meant as a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for bedrooms and bed-sitting rooms (in Canada with a listed millivolt thermostat) and for manufactured\/mobile homes where local codes allow; manufactured-home installs need an 8 AWG copper ground to the chassis (pp.7–8).\u003c\/li\u003e\n\u003cli\u003eGas orifices are sized for 0–4,500 ft elevation (p.41).\u003c\/li\u003e\n\u003cli\u003eIndoor appliance. A covered outdoor location is allowed only for basic millivolt models without fan or lights, with a roof overhang and no operation below 32°F (p.9).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFraming, chase and clearances (pp.10–28)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMinimum ceiling\/enclosure height 70\" from the bottom of the fireplace; front clearance 36\"; 0\" at the back, sides, floor and top standoffs (pp.17–18, 26).\u003c\/li\u003e\n\u003cli\u003eFold out and screw the standoffs before installing; framing must not extend past them. No hearth is required (p.10).\u003c\/li\u003e\n\u003cli\u003eRun horizontal venting straight out the back wall above the flue with a wall thimble; no horizontal runs or offsets inside the enclosure (pp.11, 16).\u003c\/li\u003e\n\u003cli\u003eUnvented chase: non-combustible facing at least 26-7\/8\" x 47\"; mantel 41-7\/16\" above the bottom of the unit (pp.14, 19–20).\u003c\/li\u003e\n\u003cli\u003eVented chase: 105 sq in minimum free opening, minimum enclosure height 70\"; mantel 39-7\/16\"; non-combustible (required in both vented and unvented chases) (pp.14–15, 21–27).\u003c\/li\u003e\n\u003cli\u003eUse 1\/2\" minimum concrete board and self-tapping screws no longer than 2\". Granite and tile cracking or discoloration is not covered by the warranty (p.15).\u003c\/li\u003e\n\u003cli\u003eA combustible hearth may sit below the appliance opening (pp.20, 27).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eComponents, trim and liners (pp.29–40)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSurround ZCVRB47S1BL \/ ZCVRB47S1SS covers 44-1\/2\" W x 18-7\/8\" H; frames are 3\/4\" thick, with gap options of 5\/8\", 7\/8\" or 1-1\/8\", and non-combustible facing up to 1\" thick may run under it. Tile lip kit V47PTLK gives a frameless finish.\u003c\/li\u003e\n\u003cli\u003eThe Z46FK fan installs with its speed control outside the firebox; a split receptacle provides constant power inside the unit and must be installed by a qualified electrician (pp.33–34).\u003c\/li\u003e\n\u003cli\u003eNever operate with the glass door removed, cracked or broken; replacement glass must be the Kingsman part (pp.5–6, 35).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.41–49)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.41).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.41).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe (natural gas) with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC. Disconnect the appliance for pressure tests above 1\/2 psig (p.41).\u003c\/li\u003e\n\u003cli\u003eField conversion between natural gas and propane uses the Kingsman kits 46ZRB-CKLP \/ -CKNG (millivolt); 46ZRB-CKLPI \/ -CKNGI and 46VRB-CKLP2 \/ -CKNG2 (IPI), installed by a qualified agency (pp.46–48).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician; check the flame monthly.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eElectrical\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity to run. Do not wire 120 V to millivolt switches or thermostats; wall-switch wire runs are limited by gauge (e.g. 18 AWG up to 40 ft).\u003c\/li\u003e\n\u003cli\u003eThe fan kit, light kit and IPI adapter need a grounded three-prong 120 VAC receptacle; do not remove the ground prong (pp.6, 33–34).\u003c\/li\u003e\n\u003cli\u003eIPI battery backup runs the fire during a power outage on four AA batteries; fans and lights do not run on battery. Replace them before each heating season.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMedia, logs and lighting (pp.50–60)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSpread the decorative glass embers on the burner and media tray before use (maximum 5 lb); never cover the pilot, and the pilot must be visible when lighting.\u003c\/li\u003e\n\u003cli\u003eApproved options include RBCB1 cannonballs, glass colours and Kingsman linear log sets; the ULK2 light kit runs on a 12 VAC transformer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eIPI and Proflame controls (pp.61–75)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eIPI models can run in intermittent pilot mode or a cold-climate standing-pilot mode, which keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eThe Proflame 2 system has a 24-hour safety shut-off if the remote is not heard from; the WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.76–86)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: 4\"\/7\" (Kingsman Z-Flex 4\"\/7\" flex or 4\" x 6-5\/8\" rigid direct vent). Only components listed for this appliance may be used, and systems must not be mixed.\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 52\" (4'-4\"); maximum vertical 43 ft; maximum horizontal 20 ft; 1\/4\" of rise per 12\" of horizontal run (p.79).\u003c\/li\u003e\n\u003cli\u003eElbows: two 45° bends (each takes 18\" off the horizontal run) plus two more 90° bends (36\" each) (p.79).\u003c\/li\u003e\n\u003cli\u003eRestrictor: remove the flue restrictor for runs under 15 ft (p.82).\u003c\/li\u003e\n\u003cli\u003eKey terminal clearances: 12\" above grade, decks and balconies; 9\" from openable windows and doors (10,000–50,000 BTU\/h class); 18\" from a ventilated soffit; 24\" from an adjacent wall; 7 ft above public walkways; 3 ft from a gas meter or regulator; terminate at least 18\" above the roof. Keep combustibles 24\" from the hot termination cap.\u003c\/li\u003e\n\u003cli\u003ePower venting (PVH58 \/ PVH58FM) is approved for long horizontal runs; downward runs are allowed only on IPI models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use (p.5)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out during curing.\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting.\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, and do not use the fireplace if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.8).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.7).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (ZCVRB47 installation and operating manual (47ZCV-MAN19), p.91).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — ZCVRB47\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the ZCVRB47 need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: framing goes right to the fold-out standoffs with 0\" at the back, sides and top, and must not extend past them. The enclosure needs at least 70\" of height from the bottom of the fireplace, and no hearth is required. The unit measures 46-5\/8\" W × 38-5\/8\" H × 17-3\/4\" D.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 4\"\/7\" direct vent pipe (Kingsman Z-Flex 4\"\/7\" flex or 4\" x 6-5\/8\" rigid). Vertical runs go from 52\" minimum to 43 ft maximum, and horizontal runs up to 20 ft, sloped up 1\/4\" per foot. The PVH58 or PVH58FM power vent is approved for long horizontal runs.\u003c\/p\u003e\n\u003ch4\u003eCan the ZCVRB47 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It comes as ZCVRB47N \/ ZCVRB47LP (millivolt) and ZCVRB47NE \/ ZCVRB47LPE (IPI), rated 24,500 \/ 16,500 BTU\/h (max\/min) on natural gas and 24,500 \/ 20,500 BTU\/h on propane. Field conversion kits are 46ZRB-CKLP \/ -CKNG (millivolt) and 46ZRB-CKLPI \/ -CKNGI and 46VRB-CKLP2 \/ -CKNG2 (IPI).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models keep the fire running on four AA backup batteries; the fan and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eCan a TV go above it, and how high must the mantel be?\u003c\/h4\u003e\u003cp\u003eA TV above is recommended only with a vented chase (or the recessed option), kept at least 1\" from the vent grill or opening. A combustible mantel must be at least 41-7\/16\" above the bottom of the unit with an unvented chase, or 39-7\/16\" with a vented chase.\u003c\/p\u003e\n\u003ch4\u003eWhat's the warranty?\u003c\/h4\u003e\u003cp\u003eDefective components are covered for parts and labour for the first year after installation, except accent light bulbs, gasketing, glass fronts and paint. The heat exchanger, combustion chamber and burner carry a limited lifetime warranty for as long as the original owner owns the fireplace; after the first year the defective part is exchanged, and labour and freight are not covered.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912049168546,"sku":"ZCVRB47N","price":4625.93,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912049201314,"sku":"ZCVRB47LP","price":4703.21,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912049234082,"sku":"ZCVRB47NE","price":5030.45,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI","offer_id":50912049266850,"sku":"ZCVRB47LPE","price":5105.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/ZCVRB47-60-WEB-1.jpg?v=1795038111"},{"product_id":"kingsman-zcvrb60-60-linear-gas-fireplace-zcvrb60","title":"Kingsman ZCVRB60 60\" Linear Gas Fireplace ZCVRB60","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman ZCVRB60 is a 60-inch zero-clearance linear direct vent gas fireplace and the middle size of the ZCVRB family, a bigger flame picture than the 47 for large living rooms while narrower than the 72. With 0\" clearance at the back, sides and top standoffs, it fits flush-to-wall, corner, island and room-divider layouts and exterior walls.\u003c\/p\u003e\u003cp\u003eA 61-1\/8\" x 19-15\/16\" viewing area shows a long ribbon of flame over the included bronze ember glass. Cannonballs, other glass colours, driftwood, birch or oak linear logs and a porcelain reflective liner change the look. Input is up to 35,000 BTU\/h on natural gas or propane with Hi\/Lo turndown, at a fireplace efficiency of 55.27% MV \/ 56.66% IPI. It is certified as a vented room heater and approved for bedrooms, bed-sitting rooms and manufactured homes.\u003c\/p\u003e\u003cp\u003eMillivolt models need no house power; IPI models have battery backup and pair with Proflame remotes. It vents 5\"\/8\" through the wall or roof, or with the optional PVH58 power vent. A vented chase (Kingsman's Cool Touch Wall) runs about 40% cooler and lowers the minimum mantel height from 39-3\/4\" to 29-1\/2\", which makes a TV above practical.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear direct vent design\u003c\/strong\u003e: sealed combustion draws outside air and exhausts outdoors through 5\"\/8\" venting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance installation\u003c\/strong\u003e: 0\" to combustibles at the back, sides, floor and top standoffs; 36\" in front (manual pp.18, 26).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt valve\u003c\/strong\u003e: standard on millivolt models; operates during power failures with no electricity needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIPI electronic ignition (optional models)\u003c\/strong\u003e: intermittent pilot ignition with battery backup; a cold-climate (standing pilot) setting is available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDecorative bronze ember glass\u003c\/strong\u003e: included and required: the fireplace must not run without the glass embers on the burner and media tray.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTempered glass front\u003c\/strong\u003e: 61-1\/8\" x 19-15\/16\" viewing area.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included over the glass to reduce the risk of burns from the hot glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 35,000 BTU\/h maximum input on natural gas and propane; Hi\/Lo turndown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 55.27% MV \/ 56.66% IPI (Kingsman specification).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: mobile\/manufactured home, bedroom and bed-sitting room approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVented chase option (Cool Touch Wall)\u003c\/strong\u003e: vent the chase with grills or an open top for cooler walls and a lower 29-1\/2\" mantel; minimum free area 200 sq in (open top) \/ 220 sq in (grills).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure grills (optional)\u003c\/strong\u003e: VL60EG front grill (60-5\/8\" x 3-5\/8\" opening, 220 sq in); VL60EGS side grills, pair (two 15-1\/4\" x 6-5\/8\" openings, 220 sq in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurround (optional)\u003c\/strong\u003e: ZCVRB60S1BL black or ZCVRB60S1SS stainless steel, covers 64\" W x 23\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z46FK heat-activated fan with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal light kit (optional)\u003c\/strong\u003e: ULK64 four-lamp universal light kit (12 VAC halogen) for accent lighting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall thermostat (optional)\u003c\/strong\u003e: standard on\/off or programmable 5-day\/2-day models (Z2MT, Z80PT).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote controls (optional)\u003c\/strong\u003e: on\/off, thermostatic, thermostatic modulating, and thermostatic modulating with fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (IPI PF2 models)\u003c\/strong\u003e: flame-height modulation and multi-colour LED accent lighting control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH puts the IPI backup batteries in an accessible wall box within 16 ft of the valve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiner option\u003c\/strong\u003e: ZCVRB60PL porcelain reflective liner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedia options\u003c\/strong\u003e: RBCB1 multi-coloured cannonballs, alternative glass colours and linear log sets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 or PVH58FM power vent for extended horizontal runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: NG\/LP conversion kits available (60ZCVRB-CKLP \/ -CKNG (millivolt); 60ZCVRB-CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI)).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19 \/ CSA 2.33-19 vented gas fireplace heater; CSA 2.17-2017 (high altitude).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eZCVRB60N \/ ZCVRB60LP (millivolt); ZCVRB60NE \/ ZCVRB60LPE (IPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eZero-clearance linear direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e66-3\/16\" W x 39-9\/16\" H x 19-1\/4\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eRough-opening width and depth not published by the manufacturer. Framing goes to the fold-out standoffs at 0\" (back, sides and top) and must not extend past them; header height 39-3\/4\", maximum header depth 3-1\/2\"; minimum enclosure height 76\" from the bottom of the fireplace; 56\" minimum framing height for horizontal venting, plus 1\/4\" of rise per foot; no hearth required (manual pp.10, 17–18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e61-1\/8\" W x 19-15\/16\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eFront 36\"; back, sides, floor and top standoffs 0\"; ceiling\/enclosure at least 76\" above the bottom of the fireplace; top of a 90° bend 4\"; top of horizontal pipe 2\"; sides and bottom of horizontal pipe 1\"; vertical pipe 1\" (pp.18, 26); mantel at least 39-3\/4\" (unvented chase) or 29-1\/2\" (vented chase) above the bottom of the unit (p.14); TV above only with a vented chase or the recessed option, at least 1\" from the vent grill or opening (pp.14, 25)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e35,000 \/ 23,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e35,000 \/ 28,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e55.27% MV \/ 56.66% IPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eTempered, with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e5\"\/8\" (Kingsman Z-Flex 5\"\/8\" flex or listed 5\"\/8\" rigid direct vent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e120 VAC grounded receptacle for fan \/ IPI adapter; millivolt runs without power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMedia included\u003c\/th\u003e\n\u003ctd\u003eDecorative bronze ember glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum media load\u003c\/th\u003e\n\u003ctd\u003e15 lb NG \/ 10 lb LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprovals\u003c\/th\u003e\n\u003ctd\u003eBedroom, bed-sitting room, manufactured\/mobile home\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNon-combustible facing (unvented chase): at least 29-1\/2\" x 67\"; recommended 31-15\/16\" x 68-1\/2\" (p.19).\u003c\/li\u003e\n\u003cli\u003eVented chase: minimum enclosure height 76\"; minimum free opening 200 sq in (open top) \/ 220 sq in (grills); grills within 3\/4\" of the sealed enclosure top; open top 1-7\/8\" minimum on three sides (pp.13, 21–24).\u003c\/li\u003e\n\u003cli\u003eAppliance weight: not listed in the manual text.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with linear burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eDecorative bronze ember glass\u003c\/li\u003e\n\u003cli\u003eTempered glass front\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier\u003c\/li\u003e\n\u003cli\u003eNailing tabs (two per side) and standoffs\u003c\/li\u003e\n\u003cli\u003eRemovable lower face panel\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e5\"\/8\" direct vent pipe and a matching horizontal or vertical termination (Kingsman Z-Flex or a listed rigid system)\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing over the face of the fireplace in an unvented chase (minimum 29-1\/2\" x 67\")\u003c\/li\u003e\n\u003cli\u003eFor a vented chase: VL60EG front grill, VL60EGS side grills, pair, a custom grill, or an open top meeting the minimum free area\u003c\/li\u003e\n\u003cli\u003eGas supply with a manual shutoff valve (3\/8\" NPT inlet; 1\/2\" rigid pipe or an approved flex connector such as FP15GC)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan kit or IPI models (split receptacle installed by an electrician)\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup and remote receiver\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZCVRB60S1BL black surround trim kit\u003c\/li\u003e\n\u003cli\u003eZCVRB60S1SS stainless steel surround trim kit\u003c\/li\u003e\n\u003cli\u003eV60PTLK tile lip kit\u003c\/li\u003e\n\u003cli\u003eZCVRB60PL porcelain reflective panel liner\u003c\/li\u003e\n\u003cli\u003eRBCB1 multi-coloured cannonballs\u003c\/li\u003e\n\u003cli\u003eZ46FK fan kit with variable speed control\u003c\/li\u003e\n\u003cli\u003eULK64 universal light kit\u003c\/li\u003e\n\u003cli\u003eZ2MT digital wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eGTRC millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eEGTRC IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCN IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCP IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCN IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCP IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI)\u003c\/li\u003e\n\u003cli\u003ePVH58 power vent\u003c\/li\u003e\n\u003cli\u003ePVH58FM flush-mount power vent\u003c\/li\u003e\n\u003cli\u003ePVC58MV power vent control module\u003c\/li\u003e\n\u003cli\u003ePVC58IPI power vent control module\u003c\/li\u003e\n\u003cli\u003eVL60EG front grill (vented chase)\u003c\/li\u003e\n\u003cli\u003eVL60EGS side grills, pair (vented chase)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2024\/01\/60ZCV-MAN19-2.pdf\"\u003eZCVRB60 installation and operating manual (60ZCV-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/07\/21056-KM-B102-ZCVRB47-60-72ENG-July2025-FNL1-Web.pdf\"\u003eZCVRB47\/60\/72 brochure and specifications (July 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (ZCVRB60 installation and operating manual (60ZCV-MAN19), cover and pp.5–7). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.4–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19 and CSA 2.33-19 as a vented gas fireplace heater (cover). It is not meant as a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for bedrooms and bed-sitting rooms (in Canada with a listed millivolt thermostat) and for manufactured\/mobile homes where local codes allow; manufactured-home installs need an 8 AWG copper ground to the chassis (pp.7–8).\u003c\/li\u003e\n\u003cli\u003eGas orifices are sized for 0–4,500 ft elevation (p.40).\u003c\/li\u003e\n\u003cli\u003eIndoor appliance. A covered outdoor location is allowed only for basic millivolt models without fan or lights, with a roof overhang and no operation below 32°F (p.9).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFraming, chase and clearances (pp.10–28)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMinimum ceiling\/enclosure height 76\" from the bottom of the fireplace; front clearance 36\"; 0\" at the back, sides, floor and top standoffs (pp.17–18, 26).\u003c\/li\u003e\n\u003cli\u003eFold out and screw the standoffs before installing; framing must not extend past them. No hearth is required (p.10).\u003c\/li\u003e\n\u003cli\u003eRun horizontal venting straight out the back wall above the flue with a wall thimble; no horizontal runs or offsets inside the enclosure (pp.11, 16).\u003c\/li\u003e\n\u003cli\u003eUnvented chase: non-combustible facing at least 29-1\/2\" x 67\"; mantel 39-3\/4\" above the bottom of the unit (pp.14, 19–20).\u003c\/li\u003e\n\u003cli\u003eVented chase: 200 sq in (open top) \/ 220 sq in (grills) minimum free opening, minimum enclosure height 76\"; mantel 29-1\/2\"; combustible facing such as drywall is allowed in a vented chase (pp.14–15, 21–27).\u003c\/li\u003e\n\u003cli\u003eUse 1\/2\" minimum concrete board and self-tapping screws no longer than 2\". Granite and tile cracking or discoloration is not covered by the warranty (p.15).\u003c\/li\u003e\n\u003cli\u003eA combustible hearth may sit below the appliance opening (pp.20, 27).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eComponents, trim and liners (pp.29–39)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSurround ZCVRB60S1BL \/ ZCVRB60S1SS covers 64\" W x 23\" H; frames are 3\/4\" thick, with gap options of 5\/8\", 7\/8\" or 1-1\/8\", and non-combustible facing up to 1\" thick may run under it. Tile lip kit V60PTLK gives a frameless finish.\u003c\/li\u003e\n\u003cli\u003eThe Z46FK fan installs with its speed control outside the firebox; a split receptacle provides constant power inside the unit and must be installed by a qualified electrician (pp.33–34).\u003c\/li\u003e\n\u003cli\u003eNever operate with the glass door removed, cracked or broken; replacement glass must be the Kingsman part (pp.5–6, 35).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.40–48)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.40).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.40).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe (natural gas) with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC. Disconnect the appliance for pressure tests above 1\/2 psig (p.40).\u003c\/li\u003e\n\u003cli\u003eField conversion between natural gas and propane uses the Kingsman kits 60ZCVRB-CKLP \/ -CKNG (millivolt); 60ZCVRB-CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI), installed by a qualified agency (pp.45–47).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician; check the flame monthly.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eElectrical\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity to run. Do not wire 120 V to millivolt switches or thermostats; wall-switch wire runs are limited by gauge (e.g. 18 AWG up to 40 ft).\u003c\/li\u003e\n\u003cli\u003eThe fan kit, light kit and IPI adapter need a grounded three-prong 120 VAC receptacle; do not remove the ground prong (pp.6, 33–34).\u003c\/li\u003e\n\u003cli\u003eIPI battery backup runs the fire during a power outage on four AA batteries; fans and lights do not run on battery. Replace them before each heating season.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMedia, logs and lighting (pp.49–61)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSpread the decorative glass embers on the burner and media tray before use (maximum 15 lb NG \/ 10 lb LP); never cover the pilot, and the pilot must be visible when lighting.\u003c\/li\u003e\n\u003cli\u003eApproved options include RBCB1 cannonballs, glass colours and Kingsman linear log sets; the ULK64 light kit runs on a 12 VAC transformer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eIPI and Proflame controls (pp.62–76)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eIPI models can run in intermittent pilot mode or a cold-climate standing-pilot mode, which keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eThe Proflame 2 system has a 24-hour safety shut-off if the remote is not heard from; the WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.77–85)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: 5\"\/8\" (Kingsman Z-Flex 5\"\/8\" flex or listed 5\"\/8\" rigid direct vent). Only components listed for this appliance may be used, and systems must not be mixed.\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 56\"; maximum vertical 43 ft; maximum horizontal 20 ft (with an 8 ft rise; 4 ft at 43 ft vertical); 1\/4\" of rise per 12\" of horizontal run (p.80).\u003c\/li\u003e\n\u003cli\u003eElbows: up to four 45° bends (18\" each) plus two more 90° bends (36\" each) (p.80).\u003c\/li\u003e\n\u003cli\u003eRestrictor: remove the Z58VT flue restrictor for runs under 15 ft; set the air-intake plate for the vent length (pp.82–83).\u003c\/li\u003e\n\u003cli\u003eKey terminal clearances: 12\" above grade, decks and balconies; 9\" from openable windows and doors (10,000–50,000 BTU\/h class); 18\" from a ventilated soffit; 24\" from an adjacent wall; 7 ft above public walkways; 3 ft from a gas meter or regulator; terminate at least 18\" above the roof. Keep combustibles 24\" from the hot termination cap.\u003c\/li\u003e\n\u003cli\u003ePower venting (PVH58 \/ PVH58FM) is approved for long horizontal runs; downward runs are allowed only on IPI models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use (p.5)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out during curing.\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting.\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, and do not use the fireplace if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.8).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.7).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (ZCVRB60 installation and operating manual (60ZCV-MAN19), p.90).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — ZCVRB60\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the ZCVRB60 need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: framing goes right to the fold-out standoffs with 0\" at the back, sides and top, and must not extend past them. The enclosure needs at least 76\" of height from the bottom of the fireplace, and no hearth is required. The unit measures 66-3\/16\" W × 39-9\/16\" H × 19-1\/4\" D.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 5\"\/8\" direct vent pipe (Kingsman Z-Flex 5\"\/8\" flex or listed 5\"\/8\" rigid). Vertical runs go from 56\" minimum to 43 ft maximum, and horizontal runs up to 20 ft with an 8 ft rise, sloped up 1\/4\" per foot. The PVH58 or PVH58FM power vent is approved for long horizontal runs.\u003c\/p\u003e\n\u003ch4\u003eCan the ZCVRB60 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It comes as ZCVRB60N \/ ZCVRB60LP (millivolt) and ZCVRB60NE \/ ZCVRB60LPE (IPI), rated 35,000 \/ 23,000 BTU\/h (max\/min) on natural gas and 35,000 \/ 28,000 BTU\/h on propane. Field conversion kits are 60ZCVRB-CKLP \/ -CKNG (millivolt) and 60ZCVRB-CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models keep the fire running on four AA backup batteries; the fan and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eCan a TV go above it, and how high must the mantel be?\u003c\/h4\u003e\u003cp\u003eA TV above is recommended only with a vented chase (or the recessed option), kept at least 1\" from the vent grill or opening. A combustible mantel must be at least 39-3\/4\" above the bottom of the unit with an unvented chase, or 29-1\/2\" with a vented chase.\u003c\/p\u003e\n\u003ch4\u003eWhat's the warranty?\u003c\/h4\u003e\u003cp\u003eDefective components are covered for parts and labour for the first year after installation, except accent light bulbs, gasketing, glass fronts and paint. The heat exchanger, combustion chamber and burner carry a limited lifetime warranty for as long as the original owner owns the fireplace; after the first year the defective part is exchanged, and labour and freight are not covered.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912049299618,"sku":"ZCVRB60N","price":5678.87,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912049332386,"sku":"ZCVRB60LP","price":5764.61,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912049365154,"sku":"ZCVRB60NE","price":6068.9,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI","offer_id":50912049397922,"sku":"ZCVRB60LPE","price":6141.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/ZCVRB47-60-WEB-5.jpg?v=1795038112"},{"product_id":"kingsman-zcvrb72-72-linear-gas-fireplace-zcvrb72","title":"Kingsman ZCVRB72 72\" Linear Gas Fireplace ZCVRB72","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman ZCVRB72 is a 72-inch zero-clearance linear direct vent gas fireplace for homeowners who want a long, modern ribbon of flame as the focal point of a living room, great room or bedroom. It sits inside a framed chase with 0\" clearance at the back, sides and top standoffs, so it fits flush-to-wall, corner, island and room-divider layouts as well as exterior walls.\u003c\/p\u003e\u003cp\u003eThe look is clean and contemporary: a wide 73-7\/8\" x 20\" viewing area with flames dancing across decorative bronze ember glass, which ships with the fireplace. You can change the mood with multi-coloured cannonballs, alternative glass colours or Kingsman's driftwood, birch and oak linear log sets, add a porcelain reflective liner to multiply the flame, and finish the opening with a black or stainless surround or a tile-lip kit for a frameless finish.\u003c\/p\u003e\u003cp\u003eHeat output is up to 50,000 BTU\/h on natural gas or propane, with a Hi\/Lo valve that lets you turn the flame and heat down for milder days. Kingsman lists a fireplace efficiency (FE) of 53.14% MV \/ 53.64% IPI. It is certified as a vented room heater and approved for bedrooms, bed-sitting rooms and manufactured homes, so it can serve as zone heat in the room you use most.\u003c\/p\u003e\u003cp\u003eChoose millivolt ignition, which needs no house power and keeps working in a power failure, or IPI electronic ignition with battery backup. IPI models can be paired with Proflame remotes (on\/off, thermostatic, modulating and fan control), and the Proflame 2 remote on IPI PF2 models adds flame-height modulation and multi-colour LED accent lighting control. A heat-activated variable-speed fan kit and wall thermostats are optional.\u003c\/p\u003e\u003cp\u003eVenting is 5\"\/8\" (Kingsman Z-Flex 5\"\/8\" flex or listed 5\"\/8\" rigid direct vent), routed horizontally through the wall or vertically through the roof, with an optional PVH58 power vent for long or difficult runs. The chase can be left unvented, or vented with a front grill, side grills or an open top to create Kingsman's Cool Touch Wall: a vented chase runs about 40% cooler and drops the minimum mantel height from 40-1\/2\" to 28\", which also makes a TV above the fireplace practical.\u003c\/p\u003e\u003cp\u003eThe 72 is the largest fireplace in the Kingsman range, with nearly six feet of flame and the highest output of the ZCVRB family; it is the only ZCVRB with ceramic glass as standard.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear direct vent design\u003c\/strong\u003e: sealed combustion draws outside air and exhausts outdoors through 5\"\/8\" venting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance installation\u003c\/strong\u003e: 0\" to combustibles at the back, sides, floor and top standoffs; 36\" in front (manual pp.18, 26).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt valve\u003c\/strong\u003e: standard on millivolt models; operates during power failures with no electricity needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIPI electronic ignition (optional models)\u003c\/strong\u003e: intermittent pilot ignition with battery backup; a cold-climate (standing pilot) setting is available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDecorative bronze ember glass\u003c\/strong\u003e: included and required: the fireplace must not run without the glass embers on the burner and media tray.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCeramic glass front\u003c\/strong\u003e: 73-7\/8\" x 20\" viewing area.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included over the glass to reduce the risk of burns from the hot glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 50,000 BTU\/h maximum input on natural gas and propane; Hi\/Lo turndown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 53.14% MV \/ 53.64% IPI (Kingsman specification).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: mobile\/manufactured home, bedroom and bed-sitting room approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVented chase option (Cool Touch Wall)\u003c\/strong\u003e: vent the chase with grills or an open top for cooler walls and a lower 28\" mantel; minimum free area 285 sq in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure grills (optional)\u003c\/strong\u003e: VL72EG front grill (78-5\/8\" x 3-5\/8\" opening, 285 sq in); VL72EGS side grills, pair (two 15-1\/4\" x 9\" openings, 285 sq in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurround (optional)\u003c\/strong\u003e: ZCVRB72S1BL black or ZCVRB72S1SS stainless steel, covers 76-3\/4\" W x 23\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z46FK heat-activated fan with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal light kit (optional)\u003c\/strong\u003e: ULK64 four-lamp universal light kit (12 VAC halogen) for accent lighting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall thermostat (optional)\u003c\/strong\u003e: standard on\/off or programmable 5-day\/2-day models (Z2MT, Z80PT).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote controls (optional)\u003c\/strong\u003e: on\/off, thermostatic, thermostatic modulating, and thermostatic modulating with fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (IPI PF2 models)\u003c\/strong\u003e: flame-height modulation and multi-colour LED accent lighting control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH puts the IPI backup batteries in an accessible wall box within 16 ft of the valve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiner option\u003c\/strong\u003e: ZCVRB72PL porcelain reflective liner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedia options\u003c\/strong\u003e: RBCB1 multi-coloured cannonballs, alternative glass colours and linear log sets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 or PVH58FM power vent for extended horizontal runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: NG\/LP conversion kits available (72ZCVRB-CKLP \/ -CKNG (millivolt); 72ZCVRB-CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI)).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19 \/ CSA 2.33-19 vented gas fireplace heater; CSA 2.17-2017 (high altitude).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eZCVRB72N \/ ZCVRB72LP (millivolt); ZCVRB72NE \/ ZCVRB72LPE (IPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eZero-clearance linear direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e78-3\/4\" W x 40-5\/16\" H x 19-3\/8\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eRough-opening size not published by the manufacturer. Framing goes directly to the fold-out standoffs (0\" at the back, sides and top) and must not extend past them; minimum ceiling\/enclosure height 79\" from the bottom of the fireplace; no hearth required (manual pp.10, 17–18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e73-7\/8\" W x 20\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eFront 36\"; back, sides, top standoffs and floor 0\"; ceiling at least 79\" above the bottom of the fireplace; combustible mantel at least 40-1\/2\" above the bottom of the unit (unvented chase) or 28\" (vented chase); vent pipe: top of a 90° bend 4\", top of horizontal pipe 2\", sides and bottom of horizontal pipe 1\", vertical pipe 1\" (pp.14, 17–18, 26)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e50,000 \/ 34,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e50,000 \/ 39,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e53.14% MV \/ 53.64% IPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic, with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e5\"\/8\" (Kingsman Z-Flex 5\"\/8\" flex or listed 5\"\/8\" rigid direct vent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e120 VAC grounded receptacle for fan \/ IPI adapter; millivolt runs without power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMedia included\u003c\/th\u003e\n\u003ctd\u003eDecorative bronze ember glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum media load\u003c\/th\u003e\n\u003ctd\u003e15 lb (10 lb with logs or stones)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprovals\u003c\/th\u003e\n\u003ctd\u003eBedroom, bed-sitting room, manufactured\/mobile home\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHorizontal-vent framing height: 71\" minimum, plus 1\/4\" of rise per foot (p.17).\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing (unvented chase): at least 32-1\/2\" x 79-1\/8\"; recommended 35-3\/4\" x 80-5\/8\" (p.19).\u003c\/li\u003e\n\u003cli\u003eVented chase: minimum enclosure height 79\"; minimum free opening 285 sq in; grills within 3\/4\" of the sealed enclosure top; open top 2-3\/8\" minimum on three sides (pp.13, 21–24).\u003c\/li\u003e\n\u003cli\u003eTV above the fireplace: recommended only with a vented chase (or the recessed option); keep the TV at least 1\" from the vent grill or opening (pp.14, 25).\u003c\/li\u003e\n\u003cli\u003eAppliance weight: not listed in the manual text.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with linear burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eDecorative bronze ember glass\u003c\/li\u003e\n\u003cli\u003eCeramic glass front\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier\u003c\/li\u003e\n\u003cli\u003eNailing tabs (two per side) and standoffs\u003c\/li\u003e\n\u003cli\u003eRemovable lower face panel\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e5\"\/8\" direct vent pipe and a matching horizontal or vertical termination (Kingsman Z-Flex or a listed rigid system)\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing over the face of the fireplace in an unvented chase (minimum 32-1\/2\" x 79-1\/8\")\u003c\/li\u003e\n\u003cli\u003eFor a vented chase: VL72EG front grill, VL72EGS side grills, pair, a custom grill, or an open top meeting the minimum free area\u003c\/li\u003e\n\u003cli\u003eGas supply with a manual shutoff valve (3\/8\" NPT inlet; 1\/2\" rigid pipe or an approved flex connector such as FP15GC)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan kit or IPI models (split receptacle installed by an electrician)\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup and remote receiver\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZCVRB72S1BL black surround trim kit\u003c\/li\u003e\n\u003cli\u003eZCVRB72S1SS stainless steel surround trim kit\u003c\/li\u003e\n\u003cli\u003eZCVRB72PL porcelain reflective panel liner\u003c\/li\u003e\n\u003cli\u003eRBCB1 multi-coloured cannonballs\u003c\/li\u003e\n\u003cli\u003eZ46FK fan kit with variable speed control\u003c\/li\u003e\n\u003cli\u003eULK64 universal light kit\u003c\/li\u003e\n\u003cli\u003eZ2MT digital or Z80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eGTRC \/ GTMRCN \/ GTMRCP \/ GTFRCN \/ GTFRCP millivolt remotes\u003c\/li\u003e\n\u003cli\u003eEGTRC \/ EGTMRCN \/ EGTMRCP \/ EGTFRCN \/ EGTFRCP IPI Proflame remotes\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI)\u003c\/li\u003e\n\u003cli\u003ePVH58 \/ PVH58FM power vent with PVC58MV or PVC58IPI control module\u003c\/li\u003e\n\u003cli\u003eVL72EG front grill and VL72EGS side grills, pair (vented chase)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2024\/01\/72ZCV-MAN19-8.pdf\"\u003eZCVRB72 installation and operating manual (72ZCV-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/07\/21056-KM-B102-ZCVRB47-60-72ENG-July2025-FNL1-Web.pdf\"\u003eZCVRB47\/60\/72 brochure and specifications (July 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (ZCVRB72 installation and operating manual (72ZCV-MAN19), cover and pp.5–7). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.4–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19 and CSA 2.33-19 as a vented gas fireplace heater (cover). It is not meant as a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for bedrooms and bed-sitting rooms (in Canada with a listed millivolt thermostat) and for manufactured\/mobile homes where local codes allow; manufactured-home installs need an 8 AWG copper ground to the chassis (pp.7–8).\u003c\/li\u003e\n\u003cli\u003eGas orifices are sized for 0–4,500 ft elevation; installations above that need the orifice sizing confirmed (p.43).\u003c\/li\u003e\n\u003cli\u003eIndoor appliance. A covered outdoor location is allowed only for basic millivolt models without fan or lights, with a roof overhang and no operation below 32°F (p.9).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFraming, chase and clearances (pp.10–28)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMinimum ceiling\/enclosure height 79\" from the bottom of the fireplace; front clearance 36\"; 0\" at the back, sides, floor and top standoffs (pp.17–18, 26).\u003c\/li\u003e\n\u003cli\u003eFold out and screw the standoffs before installing; framing must not extend past them. No hearth is required (p.10).\u003c\/li\u003e\n\u003cli\u003eRun horizontal venting straight out the back wall above the flue with a wall thimble; no horizontal runs or offsets inside the enclosure (pp.11, 16).\u003c\/li\u003e\n\u003cli\u003eUnvented chase: non-combustible facing at least 32-1\/2\" x 79-1\/8\"; mantel 40-1\/2\" above the bottom of the unit (pp.14, 19–20).\u003c\/li\u003e\n\u003cli\u003eVented chase: 285 sq in minimum free opening, minimum enclosure height 79\"; mantel 28\"; combustible facing such as drywall is allowed in a vented chase (pp.14–15, 21–27).\u003c\/li\u003e\n\u003cli\u003eUse 1\/2\" minimum concrete board and self-tapping screws no longer than 2\". Granite and tile cracking or discoloration is not covered by the warranty (p.15).\u003c\/li\u003e\n\u003cli\u003eA combustible hearth may sit below the appliance opening (pp.20, 27).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eComponents, trim and liners (pp.29–42)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSurround ZCVRB72S1BL \/ ZCVRB72S1SS covers 76-3\/4\" W x 23\" H; frames are 3\/4\" thick, with gap options of 5\/8\", 7\/8\" or 1-1\/8\", and non-combustible facing up to 1\" thick may run under it.\u003c\/li\u003e\n\u003cli\u003eThe Z46FK fan installs with its speed control outside the firebox; a split receptacle provides constant power inside the unit and must be installed by a qualified electrician (pp.33–34).\u003c\/li\u003e\n\u003cli\u003eNever operate with the glass door removed, cracked or broken; replacement glass must be the Kingsman part (pp.5–6, 35).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.43–51)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.43).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.43).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe (natural gas) with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC. Disconnect the appliance for pressure tests above 1\/2 psig (p.43).\u003c\/li\u003e\n\u003cli\u003eField conversion between natural gas and propane uses the Kingsman kits 72ZCVRB-CKLP \/ -CKNG (millivolt); 72ZCVRB-CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI), installed by a qualified agency (pp.48–50).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician; check the flame monthly.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eElectrical\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity to run. Do not wire 120 V to millivolt switches or thermostats; wall-switch wire runs are limited by gauge (e.g. 18 AWG up to 40 ft).\u003c\/li\u003e\n\u003cli\u003eThe fan kit, light kit and IPI adapter need a grounded three-prong 120 VAC receptacle; do not remove the ground prong (pp.6, 33–34).\u003c\/li\u003e\n\u003cli\u003eIPI battery backup runs the fire during a power outage on four AA batteries; fans and lights do not run on battery. Replace them before each heating season.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMedia, logs and lighting (pp.52–63)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSpread the decorative glass embers on the burner and media tray before use (maximum 15 lb (10 lb with logs or stones)); never cover the pilot, and the pilot must be visible when lighting.\u003c\/li\u003e\n\u003cli\u003eApproved options include RBCB1 cannonballs, glass colours and Kingsman linear log sets; the ULK64 light kit runs on a 12 VAC transformer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eIPI and Proflame controls (pp.64–78)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eIPI models can run in intermittent pilot mode or a cold-climate standing-pilot mode, which keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eThe Proflame 2 system has a 24-hour safety shut-off if the remote is not heard from; the WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.79–87)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: 5\"\/8\" (Kingsman Z-Flex 5\"\/8\" flex or listed 5\"\/8\" rigid direct vent). Only components listed for this appliance may be used, and systems must not be mixed.\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 71\"; maximum vertical 43 ft; maximum horizontal 20 ft (with an 8 ft rise); 1\/4\" of rise per 12\" of horizontal run (p.82).\u003c\/li\u003e\n\u003cli\u003eElbows: up to four 45° bends (18\" each) plus two more 90° bends (36\" each) (p.82).\u003c\/li\u003e\n\u003cli\u003eRestrictor: set the flue restrictor by vent length: wide open at 15–20 ft, #1 at 25 ft, #2 at 30 ft, #3 at 35 ft, #4 at 40 ft (p.85).\u003c\/li\u003e\n\u003cli\u003eKey terminal clearances: 12\" above grade, decks and balconies; 9\" from openable windows and doors (10,000–50,000 BTU\/h class); 18\" from a ventilated soffit; 24\" from an adjacent wall; 7 ft above public walkways; 3 ft from a gas meter or regulator; terminate at least 18\" above the roof. Keep combustibles 24\" from the hot termination cap.\u003c\/li\u003e\n\u003cli\u003ePower venting (PVH58 \/ PVH58FM) is approved for long horizontal runs; downward runs are allowed only on IPI models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use (p.5)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out during curing.\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting.\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, and do not use the fireplace if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.8).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.7).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (ZCVRB72 installation and operating manual (72ZCV-MAN19), p.92).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — ZCVRB72\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the ZCVRB72 need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: framing goes right to the fold-out standoffs with 0\" clearance at the back, sides and top, and must not extend past them. The enclosure needs at least 79\" of height from the bottom of the fireplace, and no hearth is required. The unit measures 78-3\/4\" W × 40-5\/16\" H × 19-3\/8\" D.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 5\"\/8\" direct vent pipe (Kingsman Z-Flex flex or listed 5\"\/8\" rigid). Vertical runs go from 71\" minimum to 43 ft maximum, and horizontal runs up to 20 ft with an 8 ft rise, sloped up 1\/4\" per foot.\u003c\/p\u003e\n\u003ch4\u003eCan the ZCVRB72 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It comes in natural gas and propane versions at up to 50,000 BTU\/h on either fuel, and field conversion kits are available: 72ZCVRB-CKLP for millivolt models and 72ZCVRB-CKLPI or 72ZCVRB-CKLP2 for IPI models.\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models keep the fire running on four AA backup batteries; the fan and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eCan a TV go above it, and how high must the mantel be?\u003c\/h4\u003e\u003cp\u003eA TV above is recommended only with a vented chase (or the recessed option), kept at least 1\" from the vent grill or opening. A combustible mantel must be at least 40-1\/2\" above the bottom of the unit with an unvented chase, or 28\" with a vented chase.\u003c\/p\u003e\n\u003ch4\u003eWhat's the warranty?\u003c\/h4\u003e\u003cp\u003eDefective components are covered for parts and labour for the first year after installation, except accent light bulbs, gasketing, glass fronts and paint. The heat exchanger, combustion chamber and burner carry a limited lifetime warranty for as long as the original owner owns the fireplace; after the first year the defective part is exchanged, and labour and freight are not covered.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912049430690,"sku":"ZCVRB72N","price":10007.76,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912049463458,"sku":"ZCVRB72LP","price":10093.49,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912049496226,"sku":"ZCVRB72NE","price":10472.65,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI","offer_id":50912049528994,"sku":"ZCVRB72LPE","price":10472.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/ZCVRB47-60-WEB-6_059a1f59-b9a7-497e-a55b-e0caa7317c0e.jpg?v=1795038112"},{"product_id":"kingsman-hbzdv3624-36-direct-vent-gas-fireplace-hbzdv3624","title":"Kingsman HBZDV3624 36\" Direct Vent Gas Fireplace HBZDV3624","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman HBZDV3624 is a 36-inch zero-clearance direct vent gas fireplace with a traditional, full-depth firebox and a log fire, and the decorative 36-inch model of the HBZDV pair, with tempered glass and the lowest input; the HBZDV3628 adds ceramic glass and more output in the same size. It gives the look of a wood-burning fireplace with push-button convenience, on an interior or exterior wall, in a corner or as an island.\u003c\/p\u003e\u003cp\u003eA dual burner sends a realistic flame across the LOGC44 Burnt Oak eight-piece log set Kingsman specifies (sold separately), behind a 29-3\/4\" W x 18-5\/8\" H tempered glass front. Finish the face with louvers and the HB36GBL grill kit or the louver-free HB36CVCK Clean View kit, and add a brick or porcelain liner. Input is 24,000 BTU\/h on natural gas with Hi\/Lo adjustment, at a fireplace efficiency of 50.48% MV \/ 52.30% IPI (NG); 52.59% \/ 54.24% (LP).\u003c\/p\u003e\u003cp\u003eMillivolt and IPI models both keep running in a power failure, and a flame sensor shuts off the gas if the pilot is not sensed. It vents 4\"\/7\" through the wall or roof, or with the optional PVH58 power vent. A wall thermostat, Proflame remote or the Z36FK fan kit add control and heat circulation.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTraditional direct vent fireplace\u003c\/strong\u003e: sealed combustion with outside air for the fire; 4\"\/7\" venting horizontal or vertical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance installation\u003c\/strong\u003e: 0\" to combustibles at the back, sides, floor and top standoffs (manual p.14).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt or IPI valve\u003c\/strong\u003e: both operate during a power failure, with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual burner\u003c\/strong\u003e: with a realistic flame pattern.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePilot flame sensor\u003c\/strong\u003e: constantly monitors the pilot and provides 100% gas shut-off if the pilot is not sensed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included over the glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTempered glass\u003c\/strong\u003e: 29-3\/4\" W x 18-5\/8\" H viewing area; decorative rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 24,000 \/ 14,000 BTU\/h max\/min natural gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 50.48% MV \/ 52.30% IPI (NG); 52.59% \/ 54.24% (LP) (Kingsman specification).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLOGC44 log set\u003c\/strong\u003e: the Kingsman log set required for this fireplace (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigner Clean View Circulating Kit (optional)\u003c\/strong\u003e: HB36CVCK: no louvers required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrill kit (optional)\u003c\/strong\u003e: HB36GBL in black, for louvered installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurround (optional)\u003c\/strong\u003e: HB36SBL black, covers 35-1\/2\" H x 41-1\/8\" W on louvered units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z36FK heat-activated fan with variable speed control (120 V, 0.4 A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: HB36RLT traditional brick, HB36RLH herringbone brick or HB36PL porcelain reflective.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat (optional)\u003c\/strong\u003e: Z2MT wall-mount millivolt thermostat or Z80PT programmable thermostat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional)\u003c\/strong\u003e: thermostat on\/off, thermostatic modulating, and thermostatic modulating with fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (IPI PF2 models)\u003c\/strong\u003e: flame-height modulation and multi-colour LED accent lighting control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH keeps the IPI backup batteries in an accessible wall box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 \/ PVH58FM for extended horizontal runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: conversion kits 3624HB-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and certification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19 \/ CSA 2.33-19, CSA 2.17-2017 (high altitude); manufactured\/mobile home approved.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eNG millivolt (HBZDV3624N) and NG IPI (HBZDV3624NE) on this listing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eZero-clearance direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003eWith the Designer Clean View kit: 38-1\/16\" W x 34-11\/16\" H x 18-7\/8\" D; with louvers: 36\" W x 34-13\/16\" H x 16-7\/16\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eRough-opening dimensions are not published by the manufacturer as labeled values. Framing runs flush to the standoffs at 0\" (back, sides and top), with the ceiling at least 60\" above the bottom of the fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e29-3\/4\" W x 18-5\/8\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eBack, sides, floor and top standoffs 0\"; ceiling at least 60\" above the bottom of the fireplace; vent pipe 3-1\/2\" above a 90° bend in a 42–43\" enclosure, 2-1\/2\" over 43\"; top of horizontal pipe 1-1\/2\", sides and bottom 1\"; vertical pipe 1\" (Kingsman flex) or 1-1\/4\" (rigid) (manual p.14); front: non-combustible facing may reach the front face but must not cover the grill or door areas unless the clean view kit is used; floor: a louvered unit may sit with the combustible floor up to 1\" above the firebox bottom (up to 7\" with the clean view kit); with vinyl flooring use a 12\" hearth or raise the unit 24\"; carpet may run 1\" onto a metal or wood panel (pp.11–14); mantels: mantel figures show 31-3\/8\" and 28-1\/4\" to the floor (p.16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e24,000 \/ 14,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e22,000 \/ 15,000 BTU\/h (LP models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e50.48% MV \/ 52.30% IPI (NG); 52.59% \/ 54.24% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eTempered, with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e4\"\/7\" Kingsman flex or 4\" x 6-5\/8\" rigid direct vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFan kit\u003c\/th\u003e\n\u003ctd\u003eOptional Z36FK, 120 V 60 Hz 0.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLog set\u003c\/th\u003e\n\u003ctd\u003eLOGC44 (required, sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAppliance weight: not listed in the manual text.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with dual burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eTempered glass front\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier kit\u003c\/li\u003e\n\u003cli\u003eNailing tabs and standoffs\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLOGC44 log set (Kingsman specifies it for this model; sold separately)\u003c\/li\u003e\n\u003cli\u003e4\"\/7\" direct vent pipe and termination (Kingsman Z-Flex or a listed 4\" x 6-5\/8\" rigid system with the ZDVDFA adapter)\u003c\/li\u003e\n\u003cli\u003eEither louvers with the HB36GBL grill kit or the HB36CVCK Designer Clean View Circulating Kit to finish the face\u003c\/li\u003e\n\u003cli\u003eGas supply with a manual shutoff valve (3\/8\" NPT inlet)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan kit or IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHB36CVCK Designer Clean View Circulating Kit\u003c\/li\u003e\n\u003cli\u003eHB36GBL black grill kit\u003c\/li\u003e\n\u003cli\u003eHB36SBL black surround\u003c\/li\u003e\n\u003cli\u003eHB36RLT traditional brick liner\u003c\/li\u003e\n\u003cli\u003eHB36RLH herringbone brick liner\u003c\/li\u003e\n\u003cli\u003eHB36PL porcelain reflective liner\u003c\/li\u003e\n\u003cli\u003eZ36FK fan kit with variable speed control\u003c\/li\u003e\n\u003cli\u003eZ2MT digital wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eGTRC millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eEGTRC IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCN IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCP IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCN IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCP IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI)\u003c\/li\u003e\n\u003cli\u003ePVH58 power vent\u003c\/li\u003e\n\u003cli\u003ePVH58FM flush-mount power vent\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/36HB-MAN19.pdf\"\u003eHBZDV3624\/3628 installation and operating manual (36HB-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2017\/03\/19717-KI-B050-HBZDV3624-284224-28ENG-May2024-FNL-WEB.pdf\"\u003eKingsman brochure and specifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (HBZDV3624\/3628 installation and operating manual (36HB-MAN19), cover and safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.2–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for manufactured\/mobile homes where local codes allow (manual mobile home section).\u003c\/li\u003e\n\u003cli\u003eIndoor appliance. A covered outdoor location is allowed only for basic millivolt models without fan or lights, with a roof overhang, and needs the local authority's approval (p.10).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation, framing and clearances (pp.10–17)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e0\" clearance at the back, sides, floor and top standoffs; ceiling at least 60\" above the bottom of the fireplace.\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing may reach the front face but must not cover the grill or door areas (unless the clean view kit is used); combustible material can run flush to the standoffs; finishes near the opening must withstand 250°F.\u003c\/li\u003e\n\u003cli\u003eMantels: mantel figures show 31-3\/8\" and 28-1\/4\" to the floor (p.16).\u003c\/li\u003e\n\u003cli\u003eVinyl flooring: 12\" minimum hearth, or raise the unit 24\" (installer's risk).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAccessories, liners and logs (pp.18–22)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUse only the LOGC44 log set and follow the log-placement diagram; the pilot must stay visible and uncovered.\u003c\/li\u003e\n\u003cli\u003eFan kit Z36FK: 120 V 60 Hz 0.4 A with a wall-mounted variable speed control; never connect the 120 V fan to the millivolt valve.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm tempered; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.39–46)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.39).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.39).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.39).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.39). Field conversion between natural gas and propane uses Kingsman kits 3624HB-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI), installed by a qualified agency (pp.42–44).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and electrical (pp.47–62)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.47–62).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eDo not wire 120 V to millivolt switches or thermostats; switch-wire length is limited by wire gauge.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.63–71)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: 4\"\/7\" Kingsman flex or approved rigid systems; propane horizontal runs need at least 1 ft of vertical rise off the flue first (pp.63–71).\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 4 ft; maximum vertical 40 ft (43 ft with roof-vent systems); maximum horizontal 20 ft; 1\/4\" rise per 12\" of horizontal run.\u003c\/li\u003e\n\u003cli\u003eUp to two 45° bends in the horizontal run (each takes 18\" off the allowed run) plus two more 90° bends (36\" each); remove the flue restrictor for runs under 15 ft.\u003c\/li\u003e\n\u003cli\u003eKeep the termination 24\" from obstructions and flammable materials, and never recess it into the wall; a PVH58 power vent is approved for Proflame 2 models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.7).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.7).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.9).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.8).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (HBZDV3624\/3628 installation and operating manual (36HB-MAN19), p.77).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — HBZDV3624\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the HBZDV3624 need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: framing runs flush to the standoffs with 0\" at the back, sides and top, and 0\" to the floor, with the ceiling at least 60\" above the bottom of the fireplace. The unit measures 38-1\/16\" W × 34-11\/16\" H × 18-7\/8\" D with the Designer Clean View kit, or 36\" W × 34-13\/16\" H × 16-7\/16\" D with louvers.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 4\"\/7\" direct vent pipe (Kingsman Z-Flex flex, or a listed 4\" x 6-5\/8\" rigid system with the ZDVDFA adapter). Vertical runs go from 4 ft minimum to 40 ft maximum (43 ft with roof-vent systems), and horizontal runs up to 20 ft, rising 1\/4\" per foot; propane horizontal runs need at least 1 ft of vertical rise off the flue first. A PVH58 power vent is approved for Proflame 2 models.\u003c\/p\u003e\n\u003ch4\u003eCan the HBZDV3624 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. This listing carries the natural gas millivolt (HBZDV3624N) and IPI (HBZDV3624NE) models, rated 24,000 \/ 14,000 BTU\/h (max\/min); propane models are rated 22,000 \/ 15,000 BTU\/h. Field conversion uses Kingsman kits 3624HB-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models keep the fire running on a battery backup; the fan and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eIs a log set included?\u003c\/h4\u003e\u003cp\u003eNo. The LOGC44 Burnt Oak eight-piece log set is required for this fireplace and sold separately, and it is the only log set approved for it.\u003c\/p\u003e\n\u003ch4\u003eCan it be installed in a bedroom?\u003c\/h4\u003e\u003cp\u003eYes. It is certified as a vented gas fireplace heater (CSA\/ANSI Z21.88) for installation in a bedroom or bed-sitting room; in Canada it must be installed with a listed millivolt thermostat. It is also approved for manufactured\/mobile homes where local codes allow.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912050774178,"sku":"HBZDV3624N","price":2439.15,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912050806946,"sku":"HBZDV3624NE","price":2854.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/KingsmanWebsite-Images-HBZDV3624-28-4224-28.jpg?v=1795038182"},{"product_id":"kingsman-hbzdv3628-36-direct-vent-gas-fireplace-hbzdv3628","title":"Kingsman HBZDV3628 36\" Direct Vent Gas Fireplace HBZDV3628","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman HBZDV3628 is a 36-inch zero-clearance direct vent gas fireplace with a traditional, full-depth firebox and a log fire, and the heater-rated 36-inch model of the HBZDV pair, with ceramic glass and 28,000 BTU\/h in the same footprint as the decorative 3624. It gives the look of a wood-burning fireplace with push-button convenience, on an interior or exterior wall, in a corner or as an island.\u003c\/p\u003e\u003cp\u003eA dual burner sends a realistic flame across the LOGC44 Burnt Oak eight-piece log set Kingsman specifies (sold separately), behind a 29-3\/4\" W x 18-5\/8\" H ceramic glass front. Finish the face with louvers and the HB36GBL grill kit or the louver-free HB36CVCK Clean View kit, and add a brick or porcelain liner. Input is 28,000 BTU\/h on natural gas with Hi\/Lo adjustment, at a fireplace efficiency of 60.61% MV \/ 62.69% IPI (NG); 62.48% \/ 64.16% (LP).\u003c\/p\u003e\u003cp\u003eMillivolt and IPI models both keep running in a power failure, and a flame sensor shuts off the gas if the pilot is not sensed. It vents 4\"\/7\" through the wall or roof, or with the optional PVH58 power vent. A wall thermostat, Proflame remote or the Z36FK fan kit add control and heat circulation.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTraditional direct vent fireplace\u003c\/strong\u003e: sealed combustion with outside air for the fire; 4\"\/7\" venting horizontal or vertical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance installation\u003c\/strong\u003e: 0\" to combustibles at the back, sides, floor and top standoffs (manual p.14).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt or IPI valve\u003c\/strong\u003e: both operate during a power failure, with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual burner\u003c\/strong\u003e: with a realistic flame pattern.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePilot flame sensor\u003c\/strong\u003e: constantly monitors the pilot and provides 100% gas shut-off if the pilot is not sensed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included over the glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCeramic glass\u003c\/strong\u003e: 29-3\/4\" W x 18-5\/8\" H viewing area; heater rated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 28,000 \/ 20,000 BTU\/h max\/min natural gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 60.61% MV \/ 62.69% IPI (NG); 62.48% \/ 64.16% (LP) (Kingsman specification).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLOGC44 log set\u003c\/strong\u003e: the Kingsman log set required for this fireplace (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigner Clean View Circulating Kit (optional)\u003c\/strong\u003e: HB36CVCK: no louvers required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrill kit (optional)\u003c\/strong\u003e: HB36GBL in black, for louvered installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurround (optional)\u003c\/strong\u003e: HB36SBL black, covers 35-1\/2\" H x 41-1\/8\" W on louvered units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z36FK heat-activated fan with variable speed control (120 V, 0.4 A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: HB36RLT traditional brick, HB36RLH herringbone brick or HB36PL porcelain reflective.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat (optional)\u003c\/strong\u003e: Z2MT wall-mount millivolt thermostat or Z80PT programmable thermostat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional)\u003c\/strong\u003e: thermostat on\/off, thermostatic modulating, and thermostatic modulating with fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (IPI PF2 models)\u003c\/strong\u003e: flame-height modulation and multi-colour LED accent lighting control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH keeps the IPI backup batteries in an accessible wall box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 \/ PVH58FM for extended horizontal runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: conversion kits 3624HB-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and certification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19 \/ CSA 2.33-19, CSA 2.17-2017 (high altitude); manufactured\/mobile home approved.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eNG millivolt (HBZDV3628N) and NG IPI (HBZDV3628NE) on this listing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eZero-clearance direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003eWith the Designer Clean View kit: 38-1\/16\" W x 34-11\/16\" H x 18-7\/8\" D; with louvers: 36\" W x 34-13\/16\" H x 16-7\/16\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eRough-opening dimensions are not published by the manufacturer as labeled values. Framing runs flush to the standoffs at 0\" (back, sides and top), with the ceiling at least 60\" above the bottom of the fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e29-3\/4\" W x 18-5\/8\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eBack, sides, floor and top standoffs 0\"; ceiling at least 60\" above the bottom of the fireplace; vent pipe 3-1\/2\" above a 90° bend in a 42–43\" enclosure, 2-1\/2\" over 43\"; top of horizontal pipe 1-1\/2\", sides and bottom 1\"; vertical pipe 1\" (Kingsman flex) or 1-1\/4\" (rigid) (manual p.14); front: non-combustible facing may reach the front face but must not cover the grill or door areas unless the clean view kit is used; floor: a louvered unit may sit with the combustible floor up to 1\" above the firebox bottom (up to 7\" with the clean view kit); with vinyl flooring use a 12\" hearth or raise the unit 24\"; carpet may run 1\" onto a metal or wood panel (pp.11–14); mantels: mantel figures show 31-3\/8\" and 28-1\/4\" to the floor (p.16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e28,000 \/ 20,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e26,000 \/ 19,000 BTU\/h (LP models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e60.61% MV \/ 62.69% IPI (NG); 62.48% \/ 64.16% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic, with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e4\"\/7\" Kingsman flex or 4\" x 6-5\/8\" rigid direct vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFan kit\u003c\/th\u003e\n\u003ctd\u003eOptional Z36FK, 120 V 60 Hz 0.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLog set\u003c\/th\u003e\n\u003ctd\u003eLOGC44 (required, sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAppliance weight: not listed in the manual text.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with dual burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eCeramic glass front\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier kit\u003c\/li\u003e\n\u003cli\u003eNailing tabs and standoffs\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLOGC44 log set (Kingsman specifies it for this model; sold separately)\u003c\/li\u003e\n\u003cli\u003e4\"\/7\" direct vent pipe and termination (Kingsman Z-Flex or a listed 4\" x 6-5\/8\" rigid system with the ZDVDFA adapter)\u003c\/li\u003e\n\u003cli\u003eEither louvers with the HB36GBL grill kit or the HB36CVCK Designer Clean View Circulating Kit to finish the face\u003c\/li\u003e\n\u003cli\u003eGas supply with a manual shutoff valve (3\/8\" NPT inlet)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan kit or IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHB36CVCK Designer Clean View Circulating Kit\u003c\/li\u003e\n\u003cli\u003eHB36GBL black grill kit\u003c\/li\u003e\n\u003cli\u003eHB36SBL black surround\u003c\/li\u003e\n\u003cli\u003eHB36RLT traditional brick liner\u003c\/li\u003e\n\u003cli\u003eHB36RLH herringbone brick liner\u003c\/li\u003e\n\u003cli\u003eHB36PL porcelain reflective liner\u003c\/li\u003e\n\u003cli\u003eZ36FK fan kit with variable speed control\u003c\/li\u003e\n\u003cli\u003eZ2MT digital wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eGTRC millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eEGTRC IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCN IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCP IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCN IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCP IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI)\u003c\/li\u003e\n\u003cli\u003ePVH58 power vent\u003c\/li\u003e\n\u003cli\u003ePVH58FM flush-mount power vent\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/36HB-MAN19.pdf\"\u003eHBZDV3624\/3628 installation and operating manual (36HB-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2017\/03\/19717-KI-B050-HBZDV3624-284224-28ENG-May2024-FNL-WEB.pdf\"\u003eKingsman brochure and specifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (HBZDV3624\/3628 installation and operating manual (36HB-MAN19), cover and safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.2–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for manufactured\/mobile homes where local codes allow (manual mobile home section).\u003c\/li\u003e\n\u003cli\u003eIndoor appliance. A covered outdoor location is allowed only for basic millivolt models without fan or lights, with a roof overhang, and needs the local authority's approval (p.10).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation, framing and clearances (pp.10–17)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e0\" clearance at the back, sides, floor and top standoffs; ceiling at least 60\" above the bottom of the fireplace.\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing may reach the front face but must not cover the grill or door areas (unless the clean view kit is used); combustible material can run flush to the standoffs; finishes near the opening must withstand 250°F.\u003c\/li\u003e\n\u003cli\u003eMantels: mantel figures show 31-3\/8\" and 28-1\/4\" to the floor (p.16).\u003c\/li\u003e\n\u003cli\u003eVinyl flooring: 12\" minimum hearth, or raise the unit 24\" (installer's risk).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAccessories, liners and logs (pp.18–22)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUse only the LOGC44 log set and follow the log-placement diagram; the pilot must stay visible and uncovered.\u003c\/li\u003e\n\u003cli\u003eFan kit Z36FK: 120 V 60 Hz 0.4 A with a wall-mounted variable speed control; never connect the 120 V fan to the millivolt valve.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm Robax or Neoceram ceramic; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.39–46)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.39).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.39).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.39).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.39). Field conversion between natural gas and propane uses Kingsman kits 3624HB-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI), installed by a qualified agency (pp.42–44).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and electrical (pp.47–62)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.47–62).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eDo not wire 120 V to millivolt switches or thermostats; switch-wire length is limited by wire gauge.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.63–71)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: 4\"\/7\" Kingsman flex or approved rigid systems; propane horizontal runs need at least 1 ft of vertical rise off the flue first (pp.63–71).\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 4 ft; maximum vertical 40 ft (43 ft with roof-vent systems); maximum horizontal 20 ft; 1\/4\" rise per 12\" of horizontal run.\u003c\/li\u003e\n\u003cli\u003eUp to two 45° bends in the horizontal run (each takes 18\" off the allowed run) plus two more 90° bends (36\" each); remove the flue restrictor for runs under 15 ft.\u003c\/li\u003e\n\u003cli\u003eKeep the termination 24\" from obstructions and flammable materials, and never recess it into the wall; a PVH58 power vent is approved for Proflame 2 models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.7).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.7).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.9).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.8).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (HBZDV3624\/3628 installation and operating manual (36HB-MAN19), p.77).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — HBZDV3628\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the HBZDV3628 need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: framing runs flush to the standoffs with 0\" at the back, sides and top, and 0\" to the floor, with the ceiling at least 60\" above the bottom of the fireplace. The unit measures 38-1\/16\" W × 34-11\/16\" H × 18-7\/8\" D with the Designer Clean View kit, or 36\" W × 34-13\/16\" H × 16-7\/16\" D with louvers.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 4\"\/7\" direct vent pipe (Kingsman Z-Flex flex, or a listed 4\" x 6-5\/8\" rigid system with the ZDVDFA adapter). Vertical runs go from 4 ft minimum to 40 ft maximum (43 ft with roof-vent systems), and horizontal runs up to 20 ft, rising 1\/4\" per foot; propane horizontal runs need at least 1 ft of vertical rise off the flue first. A PVH58 power vent is approved for Proflame 2 models.\u003c\/p\u003e\n\u003ch4\u003eCan the HBZDV3628 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. This listing carries the natural gas millivolt (HBZDV3628N) and IPI (HBZDV3628NE) models, rated 28,000 \/ 20,000 BTU\/h (max\/min); propane models are rated 26,000 \/ 19,000 BTU\/h. Field conversion uses Kingsman kits 3624HB-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models keep the fire running on a battery backup; the fan and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eIs a log set included?\u003c\/h4\u003e\u003cp\u003eNo. The LOGC44 Burnt Oak eight-piece log set is required for this fireplace and sold separately, and it is the only log set approved for it.\u003c\/p\u003e\n\u003ch4\u003eCan it be installed in a bedroom?\u003c\/h4\u003e\u003cp\u003eYes. It is certified as a vented gas fireplace heater (CSA\/ANSI Z21.88) for installation in a bedroom or bed-sitting room; in Canada it must be installed with a listed millivolt thermostat. It is also approved for manufactured\/mobile homes where local codes allow.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912050872482,"sku":"HBZDV3628N","price":3436.55,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912050905250,"sku":"HBZDV3628NE","price":3855.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/KingsmanWebsite-Images-HBZDV3628N.jpg?v=1795038183"},{"product_id":"kingsman-hbzdv4224-42-direct-vent-gas-fireplace-hbzdv4224","title":"Kingsman HBZDV4224 42\" Direct Vent Gas Fireplace HBZDV4224","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman HBZDV4224 is a 42-inch zero-clearance direct vent gas fireplace with a traditional, full-depth firebox and a log fire, and the decorative 42-inch model, with a wider fire than the 36-inch units at the same 24,000 BTU\/h input; the HBZDV4228 is the heater-rated 42-inch version. It gives the look of a wood-burning fireplace with push-button convenience, on an interior or exterior wall, in a corner or as an island.\u003c\/p\u003e\u003cp\u003eA dual burner sends a realistic flame across the LOGC44 Burnt Oak eight-piece log set Kingsman specifies (sold separately), behind a 33-3\/8\" W x 20-3\/8\" H tempered glass front. Finish the face with louvers and the HB42GBL grill kit or the louver-free HB42CVCK Clean View kit, and add a brick or porcelain liner. Input is 24,000 BTU\/h on natural gas with Hi\/Lo adjustment, at a fireplace efficiency of 55.69% MV \/ 57.81% IPI (NG); 57.03% \/ 59.09% (LP).\u003c\/p\u003e\u003cp\u003eMillivolt and IPI models both keep running in a power failure, and a flame sensor shuts off the gas if the pilot is not sensed. It vents 4\"\/7\" through the wall or roof, or with the optional PVH58 power vent. A wall thermostat, Proflame remote or the Z36FK fan kit add control and heat circulation.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTraditional direct vent fireplace\u003c\/strong\u003e: sealed combustion with outside air for the fire; 4\"\/7\" venting horizontal or vertical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance installation\u003c\/strong\u003e: 0\" to combustibles at the back, sides, floor and top standoffs (manual p.14).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt or IPI valve\u003c\/strong\u003e: both operate during a power failure, with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual burner\u003c\/strong\u003e: with a realistic flame pattern.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePilot flame sensor\u003c\/strong\u003e: constantly monitors the pilot and provides 100% gas shut-off if the pilot is not sensed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included over the glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTempered glass\u003c\/strong\u003e: 33-3\/8\" W x 20-3\/8\" H viewing area; decorative rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 24,000 \/ 14,000 BTU\/h max\/min natural gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 55.69% MV \/ 57.81% IPI (NG); 57.03% \/ 59.09% (LP) (Kingsman specification).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLOGC44 log set\u003c\/strong\u003e: the Kingsman log set required for this fireplace (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigner Clean View Circulating Kit (optional)\u003c\/strong\u003e: HB42CVCK: no louvers required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrill kit (optional)\u003c\/strong\u003e: HB42GBL in black, for louvered installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurround (optional)\u003c\/strong\u003e: HB42SBL black, covers 37-5\/8\" H x 45-1\/8\" W on louvered units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z36FK heat-activated fan with variable speed control (120 V, 0.4 A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: HB42RLT traditional brick, HB42RLH herringbone brick or HB42PL porcelain reflective.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat (optional)\u003c\/strong\u003e: Z2MT wall-mount millivolt thermostat or Z80PT programmable thermostat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional)\u003c\/strong\u003e: thermostat on\/off, thermostatic modulating, and thermostatic modulating with fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (IPI PF2 models)\u003c\/strong\u003e: flame-height modulation and multi-colour LED accent lighting control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH keeps the IPI backup batteries in an accessible wall box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 \/ PVH58FM for extended horizontal runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: conversion kits 4224\/4228HB-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and certification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19 \/ CSA 2.33-19, CSA 2.17-2017 (high altitude); manufactured\/mobile home approved.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eNG millivolt (HBZDV4224N) and NG IPI (HBZDV4224NE) on this listing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eZero-clearance direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003eWith the Designer Clean View kit: 42-1\/16\" W x 36-13\/16\" H x 18-15\/16\" D; with louvers: 41-7\/8\" W x 37\" H x 16-7\/16\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eRough-opening dimensions are not published by the manufacturer as labeled values. Framing runs flush to the standoffs at 0\" (back, sides and top), with the ceiling at least 60\" above the bottom of the fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e33-3\/8\" W x 20-3\/8\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eBack, sides, floor and top standoffs 0\"; ceiling at least 60\" above the bottom of the fireplace; vent pipe 5\" above a 90° bend in a 45–46\" enclosure, 2-1\/2\" over 46\"; top of horizontal pipe 1-1\/2\", sides and bottom 1\"; vertical pipe 1\" (Kingsman flex) or 1-1\/4\" (rigid) (manual p.14); front: non-combustible facing may reach the front face but must not cover the grill or door areas unless the clean view kit is used; floor: a louvered unit may sit with the combustible floor up to 1\" above the firebox bottom (up to 7\" with the clean view kit); with vinyl flooring use a 12\" hearth or raise the unit 24\"; carpet may run 1\" onto a metal or wood panel (pp.11–14); mantels: combustible mantel minimum height not published by the manufacturer in text form; the mantel may sit higher or lower above the top of the opening depending on its depth; a non-combustible mantel may sit at any height above the opening (except with the MQHBSW surround), and combustible objects may not sit on it unless it meets the combustible-mantel requirements (pp.16–17)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e24,000 \/ 14,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e22,000 \/ 15,000 BTU\/h (LP models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e55.69% MV \/ 57.81% IPI (NG); 57.03% \/ 59.09% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eTempered, with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e4\"\/7\" Kingsman flex or 4\" x 6-5\/8\" rigid direct vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFan kit\u003c\/th\u003e\n\u003ctd\u003eOptional Z36FK, 120 V 60 Hz 0.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLog set\u003c\/th\u003e\n\u003ctd\u003eLOGC44 (required, sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAppliance weight: not listed in the manual text.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with dual burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eTempered glass front\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier kit\u003c\/li\u003e\n\u003cli\u003eNailing tabs and standoffs\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLOGC44 log set (Kingsman specifies it for this model; sold separately)\u003c\/li\u003e\n\u003cli\u003e4\"\/7\" direct vent pipe and termination (Kingsman Z-Flex or a listed 4\" x 6-5\/8\" rigid system with the ZDVDFA adapter)\u003c\/li\u003e\n\u003cli\u003eEither louvers with the HB42GBL grill kit or the HB42CVCK Designer Clean View Circulating Kit to finish the face\u003c\/li\u003e\n\u003cli\u003eGas supply with a manual shutoff valve (3\/8\" NPT inlet)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan kit or IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHB42CVCK Designer Clean View Circulating Kit\u003c\/li\u003e\n\u003cli\u003eHB42GBL black grill kit\u003c\/li\u003e\n\u003cli\u003eHB42SBL black surround\u003c\/li\u003e\n\u003cli\u003eHB42RLT traditional brick liner\u003c\/li\u003e\n\u003cli\u003eHB42RLH herringbone brick liner\u003c\/li\u003e\n\u003cli\u003eHB42PL porcelain reflective liner\u003c\/li\u003e\n\u003cli\u003eZ36FK fan kit with variable speed control\u003c\/li\u003e\n\u003cli\u003eZ2MT digital wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eGTRC millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eEGTRC IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCN IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCP IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCN IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCP IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI)\u003c\/li\u003e\n\u003cli\u003ePVH58 power vent\u003c\/li\u003e\n\u003cli\u003ePVH58FM flush-mount power vent\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/42HB-MAN19.pdf\"\u003eHBZDV4224\/4228 installation and operating manual (42HB-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2017\/03\/19717-KI-B050-HBZDV3624-284224-28ENG-May2024-FNL-WEB.pdf\"\u003eKingsman brochure and specifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (HBZDV4224\/4228 installation and operating manual (42HB-MAN19), cover and safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.2–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for manufactured\/mobile homes where local codes allow (manual mobile home section).\u003c\/li\u003e\n\u003cli\u003eIndoor appliance. A covered outdoor location is allowed only for basic millivolt models without fan or lights, with a roof overhang, and needs the local authority's approval (p.10).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation, framing and clearances (pp.10–17)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e0\" clearance at the back, sides, floor and top standoffs; ceiling at least 60\" above the bottom of the fireplace.\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing may reach the front face but must not cover the grill or door areas (unless the clean view kit is used); combustible material can run flush to the standoffs; finishes near the opening must withstand 250°F.\u003c\/li\u003e\n\u003cli\u003eMantels: the mantel may sit higher or lower above the top of the opening depending on its depth; a non-combustible mantel may sit at any height above the opening (except with the MQHBSW surround), and combustible objects may not sit on it unless it meets the combustible-mantel requirements (pp.16–17).\u003c\/li\u003e\n\u003cli\u003eVinyl flooring: 12\" minimum hearth, or raise the unit 24\" (installer's risk).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAccessories, liners and logs (pp.18–35)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUse only the LOGC44 log set and follow the log-placement diagram; the pilot must stay visible and uncovered.\u003c\/li\u003e\n\u003cli\u003eFan kit Z36FK: 120 V 60 Hz 0.4 A with a wall-mounted variable speed control; never connect the 120 V fan to the millivolt valve.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm tempered; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.36–44)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.36).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.36).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.36).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.36). Field conversion between natural gas and propane uses Kingsman kits 4224\/4228HB-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI), installed by a qualified agency (pp.41–44).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and electrical (pp.45–59)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.45–59).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eDo not wire 120 V to millivolt switches or thermostats; switch-wire length is limited by wire gauge.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.60–68)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: 4\"\/7\" Kingsman flex or approved rigid systems; propane horizontal runs need at least 1 ft of vertical rise off the flue first (pp.60–68).\u003c\/li\u003e\n\u003cli\u003eMaximum vertical 40 ft (43 ft with flex bend systems); horizontal up to 20 ft with 7–20 ft of vertical, reducing as the vertical height increases (15 ft at 25 ft vertical, 10 ft at 30 ft, 0 at 40 ft); 4 ft maximum horizontal with the 90° bend at the flue outlet; 1\/4\" rise per 12\" of horizontal run (pp.60–68).\u003c\/li\u003e\n\u003cli\u003eUp to two 45° bends in the horizontal run (each takes 18\" off the allowed run) plus two more 90° bends (36\" each); remove the flue restrictor for runs under 15 ft.\u003c\/li\u003e\n\u003cli\u003eKeep the termination 24\" from obstructions and flammable materials, and never recess it into the wall; a PVH58 power vent is approved for Proflame 2 models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.7).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.7).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.9).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.8).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (HBZDV4224\/4228 installation and operating manual (42HB-MAN19), p.73).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — HBZDV4224\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the HBZDV4224 need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: framing runs flush to the standoffs with 0\" at the back, sides and top, and 0\" to the floor, with the ceiling at least 60\" above the bottom of the fireplace. The unit measures 42-1\/16\" W × 36-13\/16\" H × 18-15\/16\" D with the Designer Clean View kit, or 41-7\/8\" W × 37\" H × 16-7\/16\" D with louvers.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 4\"\/7\" direct vent pipe (Kingsman Z-Flex flex, or a listed 4\" x 6-5\/8\" rigid system with the ZDVDFA adapter). Vertical runs go up to 40 ft (43 ft with flex bend systems); horizontal runs go up to 20 ft with 7 to 20 ft of vertical and get shorter as the vertical grows (15 ft at 25 ft, 10 ft at 30 ft), rising 1\/4\" per foot; propane horizontal runs need at least 1 ft of vertical rise off the flue first. A PVH58 power vent is approved for Proflame 2 models.\u003c\/p\u003e\n\u003ch4\u003eCan the HBZDV4224 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. This listing carries the natural gas millivolt (HBZDV4224N) and IPI (HBZDV4224NE) models, rated 24,000 \/ 14,000 BTU\/h (max\/min); propane models are rated 22,000 \/ 15,000 BTU\/h. Field conversion uses Kingsman kits 4224\/4228HB-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models keep the fire running on a battery backup; the fan and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eIs a log set included?\u003c\/h4\u003e\u003cp\u003eNo. The LOGC44 Burnt Oak eight-piece log set is required for this fireplace and sold separately, and it is the only log set approved for it.\u003c\/p\u003e\n\u003ch4\u003eCan it be installed in a bedroom?\u003c\/h4\u003e\u003cp\u003eYes. It is certified as a vented gas fireplace heater (CSA\/ANSI Z21.88) for installation in a bedroom or bed-sitting room; in Canada it must be installed with a listed millivolt thermostat. It is also approved for manufactured\/mobile homes where local codes allow.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912050938018,"sku":"HBZDV4224N","price":2811.06,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912050970786,"sku":"HBZDV4224NE","price":3228.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/KingsmanWebsite-Images-HBZDV3624-28-4224-28_5fcc8a05-f612-4b88-9463-f7b5e5c7ae35.jpg?v=1795038183"},{"product_id":"kingsman-hbzdv4228-42-direct-vent-gas-fireplace-hbzdv4228","title":"Kingsman HBZDV4228 42\" Direct Vent Gas Fireplace HBZDV4228","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman HBZDV4228 is a 42-inch zero-clearance direct vent gas fireplace with a traditional, full-depth firebox and a log fire, and the heater-rated 42-inch model, with ceramic glass and up to 28,000 BTU\/h; the HBZDV4224 is the decorative 42-inch version. It gives the look of a wood-burning fireplace with push-button convenience, on an interior or exterior wall, in a corner or as an island.\u003c\/p\u003e\u003cp\u003eA dual burner sends a realistic flame across the LOGC44 Burnt Oak eight-piece log set Kingsman specifies (sold separately), behind a 33-3\/8\" W x 20-3\/8\" H ceramic glass front. Finish the face with louvers and the HB42GBL grill kit or the louver-free HB42CVCK Clean View kit, and add a brick or porcelain liner. Input is 28,000 BTU\/h on natural gas or 26,000 BTU\/h on propane, with Hi\/Lo adjustment, at a fireplace efficiency of 68.04% MV \/ 70.16% IPI (NG); 65.29% \/ 67.66% (LP).\u003c\/p\u003e\u003cp\u003eMillivolt and IPI models both keep running in a power failure, and a flame sensor shuts off the gas if the pilot is not sensed. It vents 4\"\/7\" through the wall or roof, or with the optional PVH58 power vent. A wall thermostat, Proflame remote or the Z36FK fan kit add control and heat circulation.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTraditional direct vent fireplace\u003c\/strong\u003e: sealed combustion with outside air for the fire; 4\"\/7\" venting horizontal or vertical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance installation\u003c\/strong\u003e: 0\" to combustibles at the back, sides, floor and top standoffs (manual p.14).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt or IPI valve\u003c\/strong\u003e: both operate during a power failure, with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual burner\u003c\/strong\u003e: with a realistic flame pattern.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePilot flame sensor\u003c\/strong\u003e: constantly monitors the pilot and provides 100% gas shut-off if the pilot is not sensed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included over the glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCeramic glass\u003c\/strong\u003e: 33-3\/8\" W x 20-3\/8\" H viewing area; heater rated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 28,000 \/ 20,000 BTU\/h max\/min natural gas; 26,000 \/ 19,000 BTU\/h propane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 68.04% MV \/ 70.16% IPI (NG); 65.29% \/ 67.66% (LP) (Kingsman specification).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLOGC44 log set\u003c\/strong\u003e: the Kingsman log set required for this fireplace (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigner Clean View Circulating Kit (optional)\u003c\/strong\u003e: HB42CVCK: no louvers required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrill kit (optional)\u003c\/strong\u003e: HB42GBL in black, for louvered installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurround (optional)\u003c\/strong\u003e: HB42SBL black, covers 37-5\/8\" H x 45-1\/8\" W on louvered units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z36FK heat-activated fan with variable speed control (120 V, 0.4 A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: HB42RLT traditional brick, HB42RLH herringbone brick or HB42PL porcelain reflective.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat (optional)\u003c\/strong\u003e: Z2MT wall-mount millivolt thermostat or Z80PT programmable thermostat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional)\u003c\/strong\u003e: thermostat on\/off, thermostatic modulating, and thermostatic modulating with fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (IPI PF2 models)\u003c\/strong\u003e: flame-height modulation and multi-colour LED accent lighting control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH keeps the IPI backup batteries in an accessible wall box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 \/ PVH58FM for extended horizontal runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: conversion kits 4224\/4228HB-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and certification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19 \/ CSA 2.33-19, CSA 2.17-2017 (high altitude); manufactured\/mobile home approved.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003enatural gas or propane, millivolt or IPI (HBZDV4228N \/ LP \/ NE \/ LPE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eZero-clearance direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003eWith the Designer Clean View kit: 42-1\/16\" W x 36-13\/16\" H x 18-15\/16\" D; with louvers: 41-7\/8\" W x 37\" H x 16-7\/16\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eRough-opening dimensions are not published by the manufacturer as labeled values. Framing runs flush to the standoffs at 0\" (back, sides and top), with the ceiling at least 60\" above the bottom of the fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e33-3\/8\" W x 20-3\/8\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eBack, sides, floor and top standoffs 0\"; ceiling at least 60\" above the bottom of the fireplace; vent pipe 5\" above a 90° bend in a 45–46\" enclosure, 2-1\/2\" over 46\"; top of horizontal pipe 1-1\/2\", sides and bottom 1\"; vertical pipe 1\" (Kingsman flex) or 1-1\/4\" (rigid) (manual p.14); front: non-combustible facing may reach the front face but must not cover the grill or door areas unless the clean view kit is used; floor: a louvered unit may sit with the combustible floor up to 1\" above the firebox bottom (up to 7\" with the clean view kit); with vinyl flooring use a 12\" hearth or raise the unit 24\"; carpet may run 1\" onto a metal or wood panel (pp.11–14); mantels: combustible mantel minimum height not published by the manufacturer in text form; the mantel may sit higher or lower above the top of the opening depending on its depth; a non-combustible mantel may sit at any height above the opening (except with the MQHBSW surround), and combustible objects may not sit on it unless it meets the combustible-mantel requirements (pp.16–17)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e28,000 \/ 20,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e26,000 \/ 19,000 BTU\/h (LP models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e68.04% MV \/ 70.16% IPI (NG); 65.29% \/ 67.66% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic, with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e4\"\/7\" Kingsman flex or 4\" x 6-5\/8\" rigid direct vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFan kit\u003c\/th\u003e\n\u003ctd\u003eOptional Z36FK, 120 V 60 Hz 0.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLog set\u003c\/th\u003e\n\u003ctd\u003eLOGC44 (required, sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAppliance weight: not listed in the manual text.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with dual burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eCeramic glass front\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier kit\u003c\/li\u003e\n\u003cli\u003eNailing tabs and standoffs\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLOGC44 log set (Kingsman specifies it for this model; sold separately)\u003c\/li\u003e\n\u003cli\u003e4\"\/7\" direct vent pipe and termination (Kingsman Z-Flex or a listed 4\" x 6-5\/8\" rigid system with the ZDVDFA adapter)\u003c\/li\u003e\n\u003cli\u003eEither louvers with the HB42GBL grill kit or the HB42CVCK Designer Clean View Circulating Kit to finish the face\u003c\/li\u003e\n\u003cli\u003eGas supply with a manual shutoff valve (3\/8\" NPT inlet)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan kit or IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHB42CVCK Designer Clean View Circulating Kit\u003c\/li\u003e\n\u003cli\u003eHB42GBL black grill kit\u003c\/li\u003e\n\u003cli\u003eHB42SBL black surround\u003c\/li\u003e\n\u003cli\u003eHB42RLT traditional brick liner\u003c\/li\u003e\n\u003cli\u003eHB42RLH herringbone brick liner\u003c\/li\u003e\n\u003cli\u003eHB42PL porcelain reflective liner\u003c\/li\u003e\n\u003cli\u003eZ36FK fan kit with variable speed control\u003c\/li\u003e\n\u003cli\u003eZ2MT digital wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eGTRC millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eEGTRC IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCN IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCP IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCN IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCP IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI)\u003c\/li\u003e\n\u003cli\u003ePVH58 power vent\u003c\/li\u003e\n\u003cli\u003ePVH58FM flush-mount power vent\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/42HB-MAN19.pdf\"\u003eHBZDV4224\/4228 installation and operating manual (42HB-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2017\/03\/19717-KI-B050-HBZDV3624-284224-28ENG-May2024-FNL-WEB.pdf\"\u003eKingsman brochure and specifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (HBZDV4224\/4228 installation and operating manual (42HB-MAN19), cover and safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.2–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for manufactured\/mobile homes where local codes allow (manual mobile home section).\u003c\/li\u003e\n\u003cli\u003eIndoor appliance. A covered outdoor location is allowed only for basic millivolt models without fan or lights, with a roof overhang, and needs the local authority's approval (p.10).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation, framing and clearances (pp.10–17)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e0\" clearance at the back, sides, floor and top standoffs; ceiling at least 60\" above the bottom of the fireplace.\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing may reach the front face but must not cover the grill or door areas (unless the clean view kit is used); combustible material can run flush to the standoffs; finishes near the opening must withstand 250°F.\u003c\/li\u003e\n\u003cli\u003eMantels: the mantel may sit higher or lower above the top of the opening depending on its depth; a non-combustible mantel may sit at any height above the opening (except with the MQHBSW surround), and combustible objects may not sit on it unless it meets the combustible-mantel requirements (pp.16–17).\u003c\/li\u003e\n\u003cli\u003eVinyl flooring: 12\" minimum hearth, or raise the unit 24\" (installer's risk).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAccessories, liners and logs (pp.18–35)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUse only the LOGC44 log set and follow the log-placement diagram; the pilot must stay visible and uncovered.\u003c\/li\u003e\n\u003cli\u003eFan kit Z36FK: 120 V 60 Hz 0.4 A with a wall-mounted variable speed control; never connect the 120 V fan to the millivolt valve.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm Robax or Neoceram ceramic; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.36–44)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.36).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.36).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.36).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.36). Field conversion between natural gas and propane uses Kingsman kits 4224\/4228HB-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI), installed by a qualified agency (pp.41–44).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and electrical (pp.45–59)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.45–59).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eDo not wire 120 V to millivolt switches or thermostats; switch-wire length is limited by wire gauge.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.60–68)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: 4\"\/7\" Kingsman flex or approved rigid systems; propane horizontal runs need at least 1 ft of vertical rise off the flue first (pp.60–68).\u003c\/li\u003e\n\u003cli\u003eMaximum vertical 40 ft (43 ft with flex bend systems); horizontal up to 20 ft with 7–20 ft of vertical, reducing as the vertical height increases (15 ft at 25 ft vertical, 10 ft at 30 ft, 0 at 40 ft); 4 ft maximum horizontal with the 90° bend at the flue outlet; 1\/4\" rise per 12\" of horizontal run (pp.60–68).\u003c\/li\u003e\n\u003cli\u003eUp to two 45° bends in the horizontal run (each takes 18\" off the allowed run) plus two more 90° bends (36\" each); remove the flue restrictor for runs under 15 ft.\u003c\/li\u003e\n\u003cli\u003eKeep the termination 24\" from obstructions and flammable materials, and never recess it into the wall; a PVH58 power vent is approved for Proflame 2 models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.7).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.7).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.9).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.8).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (HBZDV4224\/4228 installation and operating manual (42HB-MAN19), p.73).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — HBZDV4228\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the HBZDV4228 need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: framing runs flush to the standoffs with 0\" at the back, sides and top, and 0\" to the floor, with the ceiling at least 60\" above the bottom of the fireplace. The unit measures 42-1\/16\" W × 36-13\/16\" H × 18-15\/16\" D with the Designer Clean View kit, or 41-7\/8\" W × 37\" H × 16-7\/16\" D with louvers.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 4\"\/7\" direct vent pipe (Kingsman Z-Flex flex, or a listed 4\" x 6-5\/8\" rigid system with the ZDVDFA adapter). Vertical runs go up to 40 ft (43 ft with flex bend systems); horizontal runs go up to 20 ft with 7 to 20 ft of vertical and get shorter as the vertical grows (15 ft at 25 ft, 10 ft at 30 ft), rising 1\/4\" per foot; propane horizontal runs need at least 1 ft of vertical rise off the flue first. A PVH58 power vent is approved for Proflame 2 models.\u003c\/p\u003e\n\u003ch4\u003eCan the HBZDV4228 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It is sold in natural gas (HBZDV4228N millivolt, HBZDV4228NE IPI) and propane (HBZDV4228LP millivolt, HBZDV4228LPE IPI) versions. Natural gas models are rated 28,000 \/ 20,000 BTU\/h (max\/min) and propane models 26,000 \/ 19,000 BTU\/h. Field conversion between the two uses Kingsman kits 4224\/4228HB-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models keep the fire running on a battery backup; the fan and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eIs a log set included?\u003c\/h4\u003e\u003cp\u003eNo. The LOGC44 Burnt Oak eight-piece log set is required for this fireplace and sold separately, and it is the only log set approved for it.\u003c\/p\u003e\n\u003ch4\u003eCan it be installed in a bedroom?\u003c\/h4\u003e\u003cp\u003eYes. It is certified as a vented gas fireplace heater (CSA\/ANSI Z21.88) for installation in a bedroom or bed-sitting room; in Canada it must be installed with a listed millivolt thermostat. It is also approved for manufactured\/mobile homes where local codes allow.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912051953826,"sku":"HBZDV4228N","price":4243.16,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912051986594,"sku":"HBZDV4228LP","price":4315.61,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912052019362,"sku":"HBZDV4228NE","price":4657.33,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI","offer_id":50912052052130,"sku":"HBZDV4228LPE","price":4733.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/KingsmanWebsite-Images-HBZDV3624-28-4224-28_ef169121-ca45-4423-ad11-e2aa266e83d1.jpg?v=1795038229"},{"product_id":"kingsman-hbzdv4736-47-direct-vent-gas-fireplace-hbzdv4736","title":"Kingsman HBZDV4736 47\" Direct Vent Gas Fireplace HBZDV4736","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman HBZDV4736 is a 47-inch zero-clearance direct vent gas fireplace with a traditional, full-depth firebox and a log fire, and the largest model in the HBZDV family. It gives the look of a wood-burning fireplace with push-button convenience, on an interior or exterior wall, in a corner or as an island, and suits rooms where a big, tall fire is the focal point.\u003c\/p\u003e\u003cp\u003eA dual burner sends a realistic flame across the LOGF36 Fibre Split Oak seven-piece log set Kingsman specifies (sold separately), behind a 39-1\/2\" W x 26-3\/8\" H tempered glass front, the tallest view in the family. Finish the face with louvers and the HB47GBL grill kit or the louver-free HB47CVCK Clean View kit, and add a brick, herringbone or porcelain liner. Input is 40,000 BTU\/h on natural gas with Hi\/Lo adjustment, the highest in the family, at a fireplace efficiency of 60.39% MV \/ 61.88% IPI.\u003c\/p\u003e\u003cp\u003eMillivolt and IPI models both keep running in a power failure, and a flame sensor shuts off the gas if the pilot is not sensed. It vents 4\"\/7\" through the wall or roof, or with the optional PVH58 power vent. A wall thermostat, Proflame remote or the Z36FK fan kit add control and heat circulation.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTraditional direct vent fireplace\u003c\/strong\u003e: sealed combustion with outside air for the fire; 4\"\/7\" venting horizontal or vertical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance installation\u003c\/strong\u003e: 0\" to combustibles at the back, sides, floor and top standoffs (manual p.14).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt or IPI valve\u003c\/strong\u003e: both operate during a power failure, with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual burner\u003c\/strong\u003e: with a realistic flame pattern.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePilot flame sensor\u003c\/strong\u003e: constantly monitors the pilot and provides 100% gas shut-off if the pilot is not sensed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included over the glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTempered glass\u003c\/strong\u003e: 39-1\/2\" W x 26-3\/8\" H viewing area; heater rated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 40,000 \/ 27,000 BTU\/h max\/min natural gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 60.39% MV \/ 61.88% IPI (NG); 53.79% \/ 54.9% (LP) (Kingsman specification).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLOGF36 log set\u003c\/strong\u003e: the Kingsman log set required for this fireplace (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigner Clean View Circulating Kit (optional)\u003c\/strong\u003e: HB47CVCK: no louvers required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrill kit (optional)\u003c\/strong\u003e: HB47GBL in black, for louvered installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurround (optional)\u003c\/strong\u003e: HB47SBL black.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z36FK heat-activated fan with variable speed control (120 V, 0.4 A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: HB47RLT traditional brick, HB47RLH herringbone, HB47RRH red herringbone or HB47PL porcelain reflective.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat (optional)\u003c\/strong\u003e: Z2MT wall-mount millivolt thermostat or Z80PT programmable thermostat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional)\u003c\/strong\u003e: thermostat on\/off, thermostatic modulating, and thermostatic modulating with fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (IPI PF2 models)\u003c\/strong\u003e: flame-height modulation and multi-colour LED accent lighting control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH keeps the IPI backup batteries in an accessible wall box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 \/ PVH58FM for extended horizontal runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: conversion kits 4740HB-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and certification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19 \/ CSA 2.33-19, CSA 2.17-2017 (high altitude); manufactured\/mobile home approved.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eNG millivolt (HBZDV4736N) and NG IPI (HBZDV4736NE) on this listing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eZero-clearance direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003eWith the Designer Clean View kit: 47-1\/16\" W x 43-1\/16\" H x 19-7\/16\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eRough-opening dimensions are not published by the manufacturer as labeled values. Framing runs flush to the standoffs at 0\" (back, sides and top), with the ceiling at least 60\" above the bottom of the fireplace; raise the fireplace at least 3-1\/2\" for the MQHB47SWCC surround or 2-3\/4\" for the MQHB47SWCV surround (p.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e39-1\/2\" W x 26-3\/8\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eBack, sides, floor and top standoffs 0\"; ceiling at least 60\" above the bottom of the fireplace (on an 8 ft ceiling the unit can be raised no more than 36\"); vent pipe 2-1\/2\" above a 90° bend in a 50-1\/2\" to 56-1\/2\" enclosure, 4-1\/2\" at 56-1\/2\" to 60\", 2-1\/2\" over 60\"; top of horizontal pipe 1-1\/2\", sides and bottom 1\"; vertical pipe 1\" (Kingsman flex) or 1-1\/4\" (rigid) (pp.18–19, 69); front: non-combustible facing may reach the front face but must not cover the grill or door areas unless the clean view kit is used; floor: a louvered unit may sit with the combustible floor up to 1\" above the firebox bottom, up to 7\" with the clean view kit (p.18); mantels: mantel figures show 39-9\/16\" and 36-3\/8\" to the floor (p.23); finishes near the opening must be rated for 250°F (p.24)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e40,000 \/ 27,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e36,000 \/ 30,000 BTU\/h (LP models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e60.39% MV \/ 61.88% IPI (NG); 53.79% \/ 54.9% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eTempered, with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e4\"\/7\" Kingsman flex or 4\" x 6-5\/8\" rigid direct vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFan kit\u003c\/th\u003e\n\u003ctd\u003eOptional Z36FK, 120 V 60 Hz 0.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLog set\u003c\/th\u003e\n\u003ctd\u003eLOGF36 (required, sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAppliance weight: not listed in the manual text.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with dual burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eTempered glass front\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier kit\u003c\/li\u003e\n\u003cli\u003eNailing tabs and standoffs\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLOGF36 log set (Kingsman specifies it for this model; sold separately)\u003c\/li\u003e\n\u003cli\u003e4\"\/7\" direct vent pipe and termination (Kingsman Z-Flex or a listed 4\" x 6-5\/8\" rigid system with the ZDVDFA adapter)\u003c\/li\u003e\n\u003cli\u003eEither louvers with the HB47GBL grill kit or the HB47CVCK Designer Clean View Circulating Kit to finish the face\u003c\/li\u003e\n\u003cli\u003eGas supply with a manual shutoff valve (3\/8\" NPT inlet)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan kit or IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHB47CVCK Designer Clean View Circulating Kit\u003c\/li\u003e\n\u003cli\u003eHB47GBL black grill kit\u003c\/li\u003e\n\u003cli\u003eHB47SBL black surround\u003c\/li\u003e\n\u003cli\u003eHB47RLT traditional brick liner\u003c\/li\u003e\n\u003cli\u003eHB47RLH herringbone liner\u003c\/li\u003e\n\u003cli\u003eHB47RRH red herringbone liner\u003c\/li\u003e\n\u003cli\u003eHB47PL porcelain reflective liner\u003c\/li\u003e\n\u003cli\u003eZ36FK fan kit with variable speed control\u003c\/li\u003e\n\u003cli\u003eZ2MT digital wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eGTRC millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eEGTRC IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCN IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCP IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCN IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCP IPI Proflame remote\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI)\u003c\/li\u003e\n\u003cli\u003ePVH58 power vent\u003c\/li\u003e\n\u003cli\u003ePVH58FM flush-mount power vent\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/36MQ-Man19.pdf\"\u003eHBZDV4736 installation and operating manual (36MQ-Man19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/07\/21044-KM-B099-HBZDV4736ENG-July2024-FNL1-Web.pdf\"\u003eKingsman brochure and specifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (HBZDV4736 installation and operating manual (36MQ-Man19), cover and safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.2–10)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for manufactured\/mobile homes where local codes allow (manual mobile home section).\u003c\/li\u003e\n\u003cli\u003eIndoor appliance. A covered outdoor location is allowed only for basic millivolt models without fan or lights, with a roof overhang, and needs the local authority's approval (p.10).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation, framing and clearances (pp.17–22)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e0\" clearance at the back, sides, floor and top standoffs; ceiling at least 60\" above the bottom of the fireplace.\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing may reach the front face but must not cover the grill or door areas (unless the clean view kit is used); combustible material can run flush to the standoffs; finishes near the opening must withstand 250°F.\u003c\/li\u003e\n\u003cli\u003eMantels: mantel figures for the 47HB show 39-9\/16\" and 36-3\/8\" to the floor (p.23); finishes near the opening must be rated for 250°F (p.24).\u003c\/li\u003e\n\u003cli\u003eVinyl flooring: 12\" minimum hearth, or raise the unit 24\" (installer's risk).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAccessories, liners and logs (pp.23–40)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUse only the LOGF36 log set and follow the log-placement diagram; the pilot must stay visible and uncovered.\u003c\/li\u003e\n\u003cli\u003eFan kit Z36FK: 120 V 60 Hz 0.4 A with a wall-mounted variable speed control; never connect the 120 V fan to the millivolt valve.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm tempered; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.41–49)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.41).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.41).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.41).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.41). Field conversion between natural gas and propane uses Kingsman kits 4740HB-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI), installed by a qualified agency (pp.45–48).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and electrical (pp.50–66)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.50–66).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eDo not wire 120 V to millivolt switches or thermostats; switch-wire length is limited by wire gauge.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.67–75)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: 4\"\/7\" Kingsman flex or approved rigid systems; propane horizontal runs need at least 1 ft of vertical rise off the flue first (pp.67–75).\u003c\/li\u003e\n\u003cli\u003eMaximum vertical 40 ft (43 ft for flex-pipe roof systems, p.72); horizontal up to 20 ft with 7–20 ft of vertical, less outside that range (5 ft at 4 ft vertical, 8 ft at 5 ft, 12 ft at 6 ft, 15 ft at 25 ft, 10 ft at 30 ft, 0 at 40 ft); 4 ft maximum horizontal with the 90° bend at the flue outlet; 1\/4\" rise per 12\" of horizontal run (p.70).\u003c\/li\u003e\n\u003cli\u003eUp to two 45° bends in the horizontal run (each takes 18\" off the allowed run) plus two more 90° bends (36\" each); remove the flue restrictor for runs under 15 ft.\u003c\/li\u003e\n\u003cli\u003eKeep the termination 24\" from obstructions and flammable materials, and never recess it into the wall; a PVH58 power vent is approved for Proflame 2 models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.7).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.7).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.9).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.8).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (HBZDV4736 installation and operating manual (36MQ-Man19), p.76).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — HBZDV4736\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the HBZDV4736 need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: framing runs flush to the standoffs with 0\" at the back, sides and top, and 0\" to the floor, with the ceiling at least 60\" above the bottom of the fireplace. The unit measures 47-1\/16\" W × 43-1\/16\" H × 19-7\/16\" D with the Designer Clean View kit. With the MQHB47SWCC surround the fireplace must sit at least 3-1\/2\" up, or 2-3\/4\" up with the MQHB47SWCV surround.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 4\"\/7\" direct vent pipe (Kingsman Z-Flex flex, or a listed 4\" x 6-5\/8\" rigid system with the ZDVDFA adapter). Vertical runs go up to 40 ft (43 ft for flex-pipe roof systems). Horizontal runs go up to 20 ft with 7 to 20 ft of vertical and are shorter outside that range (5 ft at 4 ft of vertical, 12 ft at 6 ft, 15 ft at 25 ft, 10 ft at 30 ft), rising 1\/4\" per foot; with the 90° bend right at the flue outlet the horizontal limit is 4 ft. A PVH58 power vent is approved for Proflame 2 models.\u003c\/p\u003e\n\u003ch4\u003eCan the HBZDV4736 run on propane?\u003c\/h4\u003e\u003cp\u003eYes, with a conversion kit. This listing carries the natural gas millivolt (HBZDV4736N) and IPI (HBZDV4736NE) models, rated 40,000 \/ 27,000 BTU\/h (max\/min). On propane the fireplace is rated 36,000 \/ 30,000 BTU\/h, and field conversion uses Kingsman kits 4740HB-CKLP \/ -CKNG (millivolt) or -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models keep the fire running on a battery backup; the fan and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eIs a log set included?\u003c\/h4\u003e\u003cp\u003eNo. The LOGF36 Fibre Split Oak seven-piece log set is required for this fireplace and sold separately, and it is the only log set approved for it.\u003c\/p\u003e\n\u003ch4\u003eCan it be installed in a bedroom?\u003c\/h4\u003e\u003cp\u003eYes. It is certified as a vented gas fireplace heater (CSA\/ANSI Z21.88) for installation in a bedroom or bed-sitting room; in Canada it must be installed with a listed millivolt thermostat. It is also approved for manufactured\/mobile homes where local codes allow.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912052084898,"sku":"HBZDV4736N","price":3708.23,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912052117666,"sku":"HBZDV4736NE","price":4124.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/HBZDV4736-Herringbone-LogF36-May2022-1.jpg?v=1795038230"},{"product_id":"kingsman-zcv34-clean-view-direct-vent-gas-fireplace-zcv34","title":"Kingsman ZCV34 Clean View Direct Vent Gas Fireplace ZCV34","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman ZCV34 is a 34-inch Designer Clean View zero-clearance direct vent gas fireplace: a traditional fire framed by a clean, louver-free face. It is the compact member of the Clean View family, sized for living rooms, family rooms, dens and bedrooms and installs flush on a wall, across a corner or in a bump-out chase.\u003c\/p\u003e\u003cp\u003eThe 28-5\/8\" W x 25-3\/8\" H tempered low-E glass shows the LOGC44 Burnt Oak log set or RBCB1 cannonballs. ZCV34RLT traditional brick, ZCV34RLH herringbone brick or ZCV34PL porcelain reflective liners set the style, and a hearth-mount or picture-frame surround or the 34ZCVTLK tile lip kit finishes the face. Input is 19,000 BTU\/h on natural gas and 18,000 BTU\/h on propane with Hi\/Lo adjustment, at a fireplace efficiency of 53.49% MV \/ 56.14% IPI (NG) and 58.67% \/ 61.17% (LP).\u003c\/p\u003e\u003cp\u003eA millivolt valve needs no house power and IPI ignition has battery backup, so both keep the fire going in a power outage. It vents 4\"\/7\" through the wall or roof, through a co-linear kit in a non-combustible chimney, or with a PVH58 power vent. Proflame remotes, wall thermostats and the Z46FK fan are available. The ZCV34H is the same fireplace with ceramic glass.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigner Clean View face\u003c\/strong\u003e: no louvers; a clean frame around the glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance direct vent\u003c\/strong\u003e: 0\" at the back, sides, floor and top standoffs; 36\" in front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt or IPI valve\u003c\/strong\u003e: operates during a power failure, with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTempered low-E glass\u003c\/strong\u003e: 28-5\/8\" W x 25-3\/8\" H viewing area.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 19,000 \/ 13,500 BTU\/h natural gas; 18,000 \/ 14,000 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 53.49% MV \/ 56.14% IPI (NG); 58.67% \/ 61.17% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame display\u003c\/strong\u003e: LOGC44 Burnt Oak log set (optional; the log holder is removed, pp.46–47) or RBCB1 cannonballs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z46FK heat-activated with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounds (optional)\u003c\/strong\u003e: ZCV34S1BL hearth-mount 3\" wide (covers 34-7\/8\" W x 30-3\/4\" H); ZCV34S1PFBL picture frame 4\" wide (covers 36-5\/6\" W x 33-3\/8\" H); ZCV34S2PFBL picture frame 1-11\/16\" wide (covers 31-1\/16\" W x 28-3\/4\" H).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTile lip kit (optional)\u003c\/strong\u003e: 34ZCVTLK for a frameless finish.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: ZCV34RLT traditional brick, ZCV34RLH herringbone brick or ZCV34PL porcelain reflective.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccent lighting (optional)\u003c\/strong\u003e: ULK2 accent light kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat (optional)\u003c\/strong\u003e: Z2MT wall-mount or Z80PT programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional)\u003c\/strong\u003e: thermostat on\/off, thermostatic modulating, thermostatic modulating with fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (IPI PF2 models)\u003c\/strong\u003e: flame-height modulation and multi-colour LED accent lighting control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVented chase option\u003c\/strong\u003e: V34EG front grill (31-3\/8\" x 3-1\/4\" opening) or V34EGS side grills (two 10-1\/4\" x 4-13\/16\" openings, both sides required); open top needs 2\" on three sides; minimum enclosure 68\".\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH for the IPI backup batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 \/ PVH58FM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: NG\/LP kits 34ZCV-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and certification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19 \/ CSA 2.33-19 heater, CSA 2.17-2017; manufactured\/mobile home approved.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eZCV34N \/ ZCV34LP (millivolt); ZCV34NE \/ ZCV34LPE (IPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eZero-clearance Clean View direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e33\" W x 36\" H x 18-1\/16\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eFramed opening 34-3\/4\" W x 38-5\/8\" H, with a 33-1\/4\" x 36-1\/8\" non-combustible area attached to the framing (non-vented chase, p.20); framing depth 18-1\/8\" for framing flush with the face of the unit, 17-5\/8\" for 1\/2\" facing flush with the face (pp.16, 21); minimum ceiling\/enclosure height from the bottom of the fireplace 48\" natural gas \/ 60\" propane (non-vented chase), 68\" (vented chase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e28-5\/8\" W x 25-3\/8\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eFront 36\"; back, sides, floor and top 0\"; top of a 90° bend 4-1\/2\"; top of horizontal pipe 1-1\/2\", sides and bottom 1\"; vertical pipe 1\" (pp.19, 27); facing: non-vented chase, all face materials non-combustible (p.20); vented chase, combustible facing allowed up to the opening (p.28); mantels: non-vented chase, 40\" (natural gas) \/ 52\" (propane) minimums from the bottom of the unit (p.18); vented chase, a combustible mantel may sit directly above the opening (p.26)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e19,000 \/ 13,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e18,000 \/ 14,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e53.49% MV \/ 56.14% IPI (NG); 58.67% \/ 61.17% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eTempered low-E, with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e4\"\/7\" flex, 4\" x 6-5\/8\" rigid, or PVH58 power vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eChase venting and floor protection\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVented chase: V34EG front grill (31-3\/8\" x 3-1\/4\" opening) or V34EGS side grills (two 10-1\/4\" x 4-13\/16\" openings, both sides required); open top needs 2\" on three sides; minimum enclosure 68\".\u003c\/li\u003e\n\u003cli\u003eFloor: no hearth is required; over carpet or another combustible floor covering use a full-width metal or wood panel; with vinyl flooring use a 12\" hearth or raise the unit 24\".\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eTempered low-E glass front\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier\u003c\/li\u003e\n\u003cli\u003eDecorative glass embers and 3\/4\" lava rock\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne media choice (required): LOGC44 Burnt Oak log set, or two 5 lb bags of Z5GC bronze glass media for the media tray (10 lb maximum, manual p.43)\u003c\/li\u003e\n\u003cli\u003e4\"\/7\" direct vent pipe and termination (Kingsman Z-Flex or listed 4\" x 6-5\/8\" rigid with the ZDVDFA adapter), or a PVH58 power vent\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing in a non-vented chase\u003c\/li\u003e\n\u003cli\u003eFor a vented chase: V34EG \/ V34EGS grills or an open top\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan or IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZCV34S1BL hearth-mount 3\" wide surround\u003c\/li\u003e\n\u003cli\u003eZCV34S1PFBL picture frame 4\" wide surround\u003c\/li\u003e\n\u003cli\u003eZCV34S2PFBL picture frame 1-11\/16\" wide surround\u003c\/li\u003e\n\u003cli\u003e34ZCVTLK tile lip kit\u003c\/li\u003e\n\u003cli\u003eZCV34RLT traditional brick\u003c\/li\u003e\n\u003cli\u003eZCV34RLH herringbone brick\u003c\/li\u003e\n\u003cli\u003eZCV34PL porcelain reflective\u003c\/li\u003e\n\u003cli\u003eRBCB1 multi-coloured cannonballs\u003c\/li\u003e\n\u003cli\u003eZ46FK fan kit\u003c\/li\u003e\n\u003cli\u003eULK2 accent light kit\u003c\/li\u003e\n\u003cli\u003eZ2MT wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eGTRC millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eEGTRC IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCN IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCP IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCN IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCP IPI remote\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder\u003c\/li\u003e\n\u003cli\u003ePVH58 power vent\u003c\/li\u003e\n\u003cli\u003ePVH58FM flush-mount power vent\u003c\/li\u003e\n\u003cli\u003eV34EG front enclosure grill\u003c\/li\u003e\n\u003cli\u003eV34EGS side enclosure grills (both sides required)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2022\/05\/34ZCV-MAN19-21.pdf\"\u003eZCV34 installation and operating manual (34ZCV-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/12\/21435-KM-B080-ZCV34-39-42ENG-Dec2025-FNL1-Web.pdf\"\u003eZCV34\/39\/42 brochure and specifications (Dec 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (ZCV34 installation and operating manual (34ZCV-MAN19), cover and safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.2–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for manufactured\/mobile homes where local codes allow (mobile home section).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.6).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFraming, chase and clearances (pp.10–28)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFront clearance 36\"; 0\" at the back, sides, floor and top; minimum ceiling\/enclosure 48\" (non-vented, natural gas) \/ 60\" (propane); 68\" with a vented chase.\u003c\/li\u003e\n\u003cli\u003eNo hearth is required.\u003c\/li\u003e\n\u003cli\u003eFacing: non-vented chase: all face materials non-combustible; framed opening 34-3\/4\" x 38-5\/8\", non-combustible area 33-1\/4\" x 36-1\/8\" (p.20); vented chase: combustible facing allowed up to the opening (p.28).\u003c\/li\u003e\n\u003cli\u003eMantels: non-vented chase: the manual shows 40\" (natural gas) \/ 52\" (propane) minimums from the bottom of the unit (p.18); vented chase: a combustible mantel may sit directly above the opening (p.26).\u003c\/li\u003e\n\u003cli\u003eVented chase: V34EG front grill (31-3\/8\" x 3-1\/4\" opening) or V34EGS side grills (two 10-1\/4\" x 4-13\/16\" openings, both sides required); open top needs 2\" on three sides; minimum enclosure 68\".\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinishing: surrounds, tile lip and doors (pp.29–42)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSurrounds: ZCV34S1BL hearth-mount 3\" wide (covers 34-7\/8\" W x 30-3\/4\" H); ZCV34S1PFBL picture frame 4\" wide (covers 36-5\/6\" W x 33-3\/8\" H); ZCV34S2PFBL picture frame 1-11\/16\" wide (covers 31-1\/16\" W x 28-3\/4\" H).\u003c\/li\u003e\n\u003cli\u003eTile lip kit 34ZCVTLK for tile or stone finished up to the opening.\u003c\/li\u003e\n\u003cli\u003eNever operate with the glass removed, cracked or broken; replacement glass must be 5 mm tempered low-E.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMedia, logs and accessories (pp.43–53)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDecorative glass embers and 3\/4\" lava rock are included; the fireplace must not run without the glass embers (two 5 lb bags of crushed glass are used, pp.2, 43–46).\u003c\/li\u003e\n\u003cli\u003eKeep the pilot visible and uncovered; use only Kingsman-listed media.\u003c\/li\u003e\n\u003cli\u003eThe Z46FK fan's speed control mounts outside the unit; a split receptacle supplies constant power and must be installed by an electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.54–64)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.54).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.54).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.54).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.54). Field conversion between natural gas and propane uses Kingsman kits 34ZCV-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI), installed by a qualified agency (pp.58–60).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and electrical (pp.65–78)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.65–78).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eDo not wire 120 V to millivolt switches or thermostats; switch-wire length is limited by gauge.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.79–90)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: 4\"\/7\" Kingsman flex, 4\" x 6-5\/8\" rigid (DuraVent with adapter) or PVH58 power vent.\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 40\" (natural gas) \/ 52\" (propane) from the bottom of the fireplace; maximum vertical 43 ft; maximum horizontal 20 ft (with a 7 ft vertical rise); 1\/4\" rise per 12\" of horizontal run.\u003c\/li\u003e\n\u003cli\u003eUp to two 45° bends in the horizontal run (18\" off the run each) plus two more 90° bends (36\" each); remove the flue restrictor for runs under 15 ft.\u003c\/li\u003e\n\u003cli\u003ePower venting: equivalent length up to 125 ft; downward runs are allowed only on IPI models without the cold-climate switch.\u003c\/li\u003e\n\u003cli\u003eKeep the termination 24\" from obstructions and flammables, terminate at least 18\" above the roof, and never recess it into the wall.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.9).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.6).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.6).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (ZCV34 installation and operating manual (34ZCV-MAN19), p.93–94).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — ZCV34\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the ZCV34 need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: 0\" at the back, sides, floor and top, with 36\" clear in front. Framing depth is 18-1\/8\" for framing flush with the face of the unit, or 17-5\/8\" with 1\/2\" facing flush with the face. In a non-vented chase the framed opening is 34-3\/4\" W x 38-5\/8\" H, and the ceiling or enclosure must be at least 48\" (natural gas) or 60\" (propane) above the bottom of the fireplace; a vented chase must be at least 68\" tall. No hearth is required.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 4\"\/7\" Kingsman flex or 4\" x 6-5\/8\" rigid direct vent pipe, a co-axial to co-linear flex kit inside a non-combustible chimney or enclosure (12 ft minimum, 43 ft maximum), or a PVH58 power vent (up to 125 ft equivalent length with up to 5 elbows). Direct vent runs go up to 43 ft vertical. Horizontal runs go up to 20 ft with 7 to 20 ft of vertical rise, and are shorter outside that range: 4 ft at the 40\" (natural gas) \/ 52\" (propane) minimum vertical, 16 ft at 6 ft, 15 ft at 25 ft and 10 ft at 30 ft, all measured from the bottom of the fireplace, with at least 1\/4\" of rise per foot of horizontal run.\u003c\/p\u003e\n\u003ch4\u003eCan the ZCV34 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It is sold in natural gas (ZCV34N, ZCV34NE) and propane (ZCV34LP, ZCV34LPE) versions, rated 19,000 \/ 13,500 BTU\/h on natural gas and 18,000 \/ 14,000 BTU\/h on propane (max\/min). Field conversion uses Kingsman kits 34ZCV-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models run on a 120 VAC adapter with a four-AA battery backup that keeps the fire working in an outage; the fan and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eIs a log set included?\u003c\/h4\u003e\u003cp\u003eNo. One media choice is required and sold separately: the LOGC44 Burnt Oak log set, or two 5 lb bags of Z5GC bronze glass media for the media tray (10 lb maximum). Decorative glass embers and 3\/4\" lava rock come with the fireplace, and RBCB1 cannonballs are an optional display.\u003c\/p\u003e\n\u003ch4\u003eCan it be installed in a bedroom?\u003c\/h4\u003e\u003cp\u003eYes. It is certified for installation in a bedroom or bed-sitting room; in Canada it must be installed with a listed millivolt thermostat. It is also approved for manufactured\/mobile homes where local codes allow.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912052838562,"sku":"ZCV34N","price":2743.44,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912052871330,"sku":"ZCV34LP","price":2844.87,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912052904098,"sku":"ZCV34NE","price":3155.2,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI","offer_id":50912052936866,"sku":"ZCV34LPE","price":3256.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Kingsman-ZCV34-PL-LOGC441500x864Feb2022-FNL.jpg?v=1795038287"},{"product_id":"kingsman-zcv34h-heater-rated-clean-view-fireplace-zcv34h","title":"Kingsman ZCV34H Heater-Rated Clean View Fireplace ZCV34H","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman ZCV34H is a 34-inch Designer Clean View zero-clearance direct vent gas fireplace: a traditional fire framed by a clean, louver-free face. It is the compact member of the Clean View family, sized for living rooms, dens and bedrooms and installs flush on a wall, across a corner or in a bump-out chase.\u003c\/p\u003e\u003cp\u003eThe 28-5\/8\" W x 25-3\/8\" H Robax or coated Neoceram ceramic glass shows the LOGC44 Burnt Oak log set or RBCB1 cannonballs. ZCV34RLT traditional brick, ZCV34RLH herringbone brick or ZCV34PL porcelain reflective liners set the style, and a hearth-mount or picture-frame surround or the 34ZCVTLK tile lip kit finishes the face. Input is 19,000 BTU\/h on natural gas and 18,000 BTU\/h on propane with Hi\/Lo adjustment, at a fireplace efficiency of 63.25% MV \/ 66.45% IPI (NG) and 66.38% \/ 69.25% (LP).\u003c\/p\u003e\u003cp\u003eA millivolt valve needs no house power and IPI ignition has battery backup, so both keep the fire going in a power outage. It vents 4\"\/7\" through the wall or roof, through a co-linear kit in a non-combustible chimney, or with a PVH58 power vent. Proflame remotes, wall thermostats and the Z46FK fan are available. The ZCV34 is the same fireplace with tempered low-E glass.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigner Clean View face\u003c\/strong\u003e: no louvers; a clean frame around the glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance direct vent\u003c\/strong\u003e: 0\" at the back, sides, floor and top standoffs; 36\" in front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt or IPI valve\u003c\/strong\u003e: operates during a power failure, with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCeramic (Robax or coated Neoceram) glass\u003c\/strong\u003e: 28-5\/8\" W x 25-3\/8\" H viewing area; heater rated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 19,000 \/ 13,500 BTU\/h natural gas; 18,000 \/ 14,000 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 63.25% MV \/ 66.45% IPI (NG); 66.38% \/ 69.25% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame display\u003c\/strong\u003e: LOGC44 Burnt Oak log set (optional; the log holder is removed, pp.46–47) or RBCB1 cannonballs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z46FK heat-activated with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounds (optional)\u003c\/strong\u003e: ZCV34S1BL hearth-mount 3\" wide (covers 34-7\/8\" W x 30-3\/4\" H); ZCV34S1PFBL picture frame 4\" wide (covers 36-5\/6\" W x 33-3\/8\" H); ZCV34S2PFBL picture frame 1-11\/16\" wide (covers 31-1\/16\" W x 28-3\/4\" H).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTile lip kit (optional)\u003c\/strong\u003e: 34ZCVTLK for a frameless finish.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: ZCV34RLT traditional brick, ZCV34RLH herringbone brick or ZCV34PL porcelain reflective.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccent lighting (optional)\u003c\/strong\u003e: ULK2 accent light kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat (optional)\u003c\/strong\u003e: Z2MT wall-mount or Z80PT programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional)\u003c\/strong\u003e: thermostat on\/off, thermostatic modulating, thermostatic modulating with fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (IPI PF2 models)\u003c\/strong\u003e: flame-height modulation and multi-colour LED accent lighting control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVented chase option\u003c\/strong\u003e: V34EG front grill (31-3\/8\" x 3-1\/4\" opening) or V34EGS side grills (two 10-1\/4\" x 4-13\/16\" openings, both sides required); open top needs 2\" on three sides; minimum enclosure 68\".\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH for the IPI backup batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 \/ PVH58FM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: NG\/LP kits 34ZCV-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and certification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19 \/ CSA 2.33-19 heater, CSA 2.17-2017; manufactured\/mobile home approved.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eZCV34NH \/ ZCV34LPH (millivolt); ZCV34NHE \/ ZCV34LPHE (IPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eZero-clearance Clean View direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e33\" W x 36\" H x 18-1\/16\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eFramed opening 34-3\/4\" W x 38-5\/8\" H, with a 33-1\/4\" x 36-1\/8\" non-combustible area attached to the framing (non-vented chase, p.20); framing depth 18-1\/8\" for framing flush with the face of the unit, 17-5\/8\" for 1\/2\" facing flush with the face (pp.16, 21); minimum ceiling\/enclosure height from the bottom of the fireplace 48\" natural gas \/ 60\" propane (non-vented chase), 68\" (vented chase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e28-5\/8\" W x 25-3\/8\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eFront 36\"; back, sides, floor and top 0\"; top of a 90° bend 4-1\/2\"; top of horizontal pipe 1-1\/2\", sides and bottom 1\"; vertical pipe 1\" (pp.19, 27); facing: non-vented chase, all face materials non-combustible (p.20); vented chase, combustible facing allowed up to the opening (p.28); mantels: non-vented chase, 40\" (natural gas) \/ 52\" (propane) minimums from the bottom of the unit (p.18); vented chase, a combustible mantel may sit directly above the opening (p.26)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e19,000 \/ 13,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e18,000 \/ 14,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e63.25% MV \/ 66.45% IPI (NG); 66.38% \/ 69.25% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic (Robax or coated Neoceram), with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e4\"\/7\" flex, 4\" x 6-5\/8\" rigid, or PVH58 power vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eChase venting and floor protection\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVented chase: V34EG front grill (31-3\/8\" x 3-1\/4\" opening) or V34EGS side grills (two 10-1\/4\" x 4-13\/16\" openings, both sides required); open top needs 2\" on three sides; minimum enclosure 68\".\u003c\/li\u003e\n\u003cli\u003eFloor: no hearth is required; over carpet or another combustible floor covering use a full-width metal or wood panel; with vinyl flooring use a 12\" hearth or raise the unit 24\".\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eCeramic (Robax or coated Neoceram) glass front\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier\u003c\/li\u003e\n\u003cli\u003eDecorative glass embers and 3\/4\" lava rock\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne media choice (required): LOGC44 Burnt Oak log set, or two 5 lb bags of Z5GC bronze glass media for the media tray (10 lb maximum, manual p.43)\u003c\/li\u003e\n\u003cli\u003e4\"\/7\" direct vent pipe and termination (Kingsman Z-Flex or listed 4\" x 6-5\/8\" rigid with the ZDVDFA adapter), or a PVH58 power vent\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing in a non-vented chase\u003c\/li\u003e\n\u003cli\u003eFor a vented chase: V34EG \/ V34EGS grills or an open top\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan or IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZCV34S1BL hearth-mount 3\" wide surround\u003c\/li\u003e\n\u003cli\u003eZCV34S1PFBL picture frame 4\" wide surround\u003c\/li\u003e\n\u003cli\u003eZCV34S2PFBL picture frame 1-11\/16\" wide surround\u003c\/li\u003e\n\u003cli\u003e34ZCVTLK tile lip kit\u003c\/li\u003e\n\u003cli\u003eZCV34RLT traditional brick\u003c\/li\u003e\n\u003cli\u003eZCV34RLH herringbone brick\u003c\/li\u003e\n\u003cli\u003eZCV34PL porcelain reflective\u003c\/li\u003e\n\u003cli\u003eRBCB1 multi-coloured cannonballs\u003c\/li\u003e\n\u003cli\u003eZ46FK fan kit\u003c\/li\u003e\n\u003cli\u003eULK2 accent light kit\u003c\/li\u003e\n\u003cli\u003eZ2MT wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eGTRC millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eEGTRC IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCN IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCP IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCN IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCP IPI remote\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder\u003c\/li\u003e\n\u003cli\u003ePVH58 power vent\u003c\/li\u003e\n\u003cli\u003ePVH58FM flush-mount power vent\u003c\/li\u003e\n\u003cli\u003eV34EG front enclosure grill\u003c\/li\u003e\n\u003cli\u003eV34EGS side enclosure grills (both sides required)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2022\/05\/34ZCV-MAN19-21.pdf\"\u003eZCV34 installation and operating manual (34ZCV-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/12\/21435-KM-B080-ZCV34-39-42ENG-Dec2025-FNL1-Web.pdf\"\u003eZCV34\/39\/42 brochure and specifications (Dec 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (ZCV34 installation and operating manual (34ZCV-MAN19), cover and safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.2–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for manufactured\/mobile homes where local codes allow (mobile home section).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.6).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFraming, chase and clearances (pp.10–28)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFront clearance 36\"; 0\" at the back, sides, floor and top; minimum ceiling\/enclosure 48\" (non-vented, natural gas) \/ 60\" (propane); 68\" with a vented chase.\u003c\/li\u003e\n\u003cli\u003eNo hearth is required.\u003c\/li\u003e\n\u003cli\u003eFacing: non-vented chase: all face materials non-combustible; framed opening 34-3\/4\" x 38-5\/8\", non-combustible area 33-1\/4\" x 36-1\/8\" (p.20); vented chase: combustible facing allowed up to the opening (p.28).\u003c\/li\u003e\n\u003cli\u003eMantels: non-vented chase: the manual shows 40\" (natural gas) \/ 52\" (propane) minimums from the bottom of the unit (p.18); vented chase: a combustible mantel may sit directly above the opening (p.26).\u003c\/li\u003e\n\u003cli\u003eVented chase: V34EG front grill (31-3\/8\" x 3-1\/4\" opening) or V34EGS side grills (two 10-1\/4\" x 4-13\/16\" openings, both sides required); open top needs 2\" on three sides; minimum enclosure 68\".\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinishing: surrounds, tile lip and doors (pp.29–42)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSurrounds: ZCV34S1BL hearth-mount 3\" wide (covers 34-7\/8\" W x 30-3\/4\" H); ZCV34S1PFBL picture frame 4\" wide (covers 36-5\/6\" W x 33-3\/8\" H); ZCV34S2PFBL picture frame 1-11\/16\" wide (covers 31-1\/16\" W x 28-3\/4\" H).\u003c\/li\u003e\n\u003cli\u003eTile lip kit 34ZCVTLK for tile or stone finished up to the opening.\u003c\/li\u003e\n\u003cli\u003eNever operate with the glass removed, cracked or broken; replacement glass must be 5 mm Robax or coated Neoceram ceramic.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMedia, logs and accessories (pp.43–53)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDecorative glass embers and 3\/4\" lava rock are included; the fireplace must not run without the glass embers (two 5 lb bags of crushed glass are used, pp.2, 43–46).\u003c\/li\u003e\n\u003cli\u003eKeep the pilot visible and uncovered; use only Kingsman-listed media.\u003c\/li\u003e\n\u003cli\u003eThe Z46FK fan's speed control mounts outside the unit; a split receptacle supplies constant power and must be installed by an electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.54–64)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.54).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.54).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.54).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.54). Field conversion between natural gas and propane uses Kingsman kits 34ZCV-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI), installed by a qualified agency (pp.58–60).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and electrical (pp.65–78)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.65–78).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eDo not wire 120 V to millivolt switches or thermostats; switch-wire length is limited by gauge.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.79–90)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: 4\"\/7\" Kingsman flex, 4\" x 6-5\/8\" rigid (DuraVent with adapter) or PVH58 power vent.\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 40\" (natural gas) \/ 52\" (propane) from the bottom of the fireplace; maximum vertical 43 ft; maximum horizontal 20 ft (with a 7 ft vertical rise); 1\/4\" rise per 12\" of horizontal run.\u003c\/li\u003e\n\u003cli\u003eUp to two 45° bends in the horizontal run (18\" off the run each) plus two more 90° bends (36\" each); remove the flue restrictor for runs under 15 ft.\u003c\/li\u003e\n\u003cli\u003ePower venting: equivalent length up to 125 ft; downward runs are allowed only on IPI models without the cold-climate switch.\u003c\/li\u003e\n\u003cli\u003eKeep the termination 24\" from obstructions and flammables, terminate at least 18\" above the roof, and never recess it into the wall.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.9).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.6).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.6).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (ZCV34 installation and operating manual (34ZCV-MAN19), p.93–94).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — ZCV34H\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the ZCV34H need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: 0\" at the back, sides, floor and top, with 36\" clear in front. Framing depth is 18-1\/8\" for framing flush with the face of the unit, or 17-5\/8\" with 1\/2\" facing flush with the face. In a non-vented chase the framed opening is 34-3\/4\" W x 38-5\/8\" H, and the ceiling or enclosure must be at least 48\" (natural gas) or 60\" (propane) above the bottom of the fireplace; a vented chase must be at least 68\" tall. No hearth is required.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 4\"\/7\" Kingsman flex or 4\" x 6-5\/8\" rigid direct vent pipe, a co-axial to co-linear flex kit inside a non-combustible chimney or enclosure (12 ft minimum, 43 ft maximum), or a PVH58 power vent (up to 125 ft equivalent length with up to 5 elbows). Direct vent runs go up to 43 ft vertical. Horizontal runs go up to 20 ft with 7 to 20 ft of vertical rise, and are shorter outside that range: 4 ft at the 40\" (natural gas) \/ 52\" (propane) minimum vertical, 16 ft at 6 ft, 15 ft at 25 ft and 10 ft at 30 ft, all measured from the bottom of the fireplace, with at least 1\/4\" of rise per foot of horizontal run.\u003c\/p\u003e\n\u003ch4\u003eCan the ZCV34H run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It is sold in natural gas (ZCV34NH, ZCV34NHE) and propane (ZCV34LPH, ZCV34LPHE) versions, rated 19,000 \/ 13,500 BTU\/h on natural gas and 18,000 \/ 14,000 BTU\/h on propane (max\/min). Field conversion uses Kingsman kits 34ZCV-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models run on a 120 VAC adapter with a four-AA battery backup that keeps the fire working in an outage; the fan and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eIs a log set included?\u003c\/h4\u003e\u003cp\u003eNo. One media choice is required and sold separately: the LOGC44 Burnt Oak log set, or two 5 lb bags of Z5GC bronze glass media for the media tray (10 lb maximum). Decorative glass embers and 3\/4\" lava rock come with the fireplace, and RBCB1 cannonballs are an optional display.\u003c\/p\u003e\n\u003ch4\u003eCan it be installed in a bedroom?\u003c\/h4\u003e\u003cp\u003eYes. It is certified for installation in a bedroom or bed-sitting room; in Canada it must be installed with a listed millivolt thermostat. It is also approved for manufactured\/mobile homes where local codes allow.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912052969634,"sku":"ZCV34NH","price":3342.36,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912053002402,"sku":"ZCV34LPH","price":3443.79,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912053035170,"sku":"ZCV34NHE","price":3754.12,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI","offer_id":50912053067938,"sku":"ZCV34LPHE","price":3855.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/ZCV34-Living-TB-LOGC441500x864March2022-FNL_7c10d80a-c127-4a60-b2b7-021fba418d4c.jpg?v=1795038288"},{"product_id":"kingsman-zcv39-clean-view-direct-vent-gas-fireplace-zcv39","title":"Kingsman ZCV39 Clean View Direct Vent Gas Fireplace ZCV39","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman ZCV39 is a 39-inch Designer Clean View zero-clearance direct vent gas fireplace: a traditional fire framed by a clean, louver-free face. It is the mid-size member of the Clean View family, sized for living rooms, family rooms and bedrooms, and installs flush on a wall, across a corner or in a bump-out chase.\u003c\/p\u003e\u003cp\u003eThe 33\" W x 28-5\/8\" H tempered glass shows the LOGF3 log set or the ZCV39GT glass tray with bronze ember glass, with RBCB1 cannonballs as an option on the tray. ZCV39RLT traditional brick, ZCV39RLH herringbone brick, ZCV39RLS stacked brick or ZCV39PL porcelain reflective liners set the style, and a hearth-mount or picture-frame surround or the ZCVTLK tile lip kit finishes the face. Input is 25,000 BTU\/h on natural gas or propane with Hi\/Lo adjustment, at a fireplace efficiency of 52.35% MV \/ 54.24% IPI.\u003c\/p\u003e\u003cp\u003eA millivolt valve needs no house power and IPI ignition has battery backup, so both keep the fire going in a power outage. It vents 4\"\/7\" through the wall or roof, through a co-linear kit, or with a PVH58 power vent. Proflame remotes, wall thermostats and the Z46FK fan are available. The ZCV39H has ceramic glass; the ZCV42 gives a bigger view.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigner Clean View face\u003c\/strong\u003e: no louvers; a clean frame around the glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance direct vent\u003c\/strong\u003e: 0\" at the back, sides, floor and top standoffs; 36\" in front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt or IPI valve\u003c\/strong\u003e: operates during a power failure, with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTempered glass\u003c\/strong\u003e: 33\" W x 28-5\/8\" H viewing area.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 25,000 \/ 16,750 BTU\/h natural gas; 25,000 \/ 20,000 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 52.35% MV \/ 54.24% IPI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame display\u003c\/strong\u003e: LOGF3 log set, ZCV39GT glass tray with bronze ember glass, RBCB1 cannonballs (glass tray required).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z46FK heat-activated with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounds (optional)\u003c\/strong\u003e: ZCV39S1BL hearth-mount 4\" wide (covers 40-5\/8\" W x 35\" H); ZCV39S1PFBL picture frame 4\" wide (covers 40-5\/8\" W x 37\" H); ZCV39S2PFBL picture frame 1-5\/8\" wide (covers 36-1\/8\" W x 32-1\/2\" H).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTile lip kit (optional)\u003c\/strong\u003e: ZCVTLK for a frameless finish.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: ZCV39RLT traditional brick, ZCV39RLH herringbone brick, ZCV39RLS stacked brick or ZCV39PL porcelain reflective.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccent lighting (optional)\u003c\/strong\u003e: ULK2 accent light kit (with the glass tray).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat (optional)\u003c\/strong\u003e: Z2MT wall-mount or Z80PT programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional)\u003c\/strong\u003e: thermostat on\/off, thermostatic modulating, thermostatic modulating with fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (IPI PF2 models)\u003c\/strong\u003e: flame-height modulation and multi-colour LED accent lighting control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVented chase option\u003c\/strong\u003e: V39EG front grill (36-1\/2\" x 3-5\/8\" opening, within 3\/4\" of the enclosure top) or V39EGS side grills (two 12-1\/2\" x 6-1\/8\" openings, both sides required); open top needs 2\" on three sides; minimum enclosure 72\".\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH for the IPI backup batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 \/ PVH58FM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: NG\/LP kits 39ZCV-CKLP, -CKNG, -CKLPI, -CKNGI, -CKLP2 and -CKNG2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and certification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19 \/ CSA 2.33-19 heater, CSA 2.17-2017; manufactured\/mobile home approved.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eZCV39N (millivolt, natural gas); ZCV39NE \/ ZCV39LPE (IPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eZero-clearance Clean View direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e39-3\/8\" W x 37-11\/16\" H x 18-7\/16\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eFraming depth 18-1\/2\" for framing flush with the face of the unit, 18\" for 1\/2\" drywall flush with the face (pp.18, 23); framed opening width and height are not published by the manufacturer as labeled values; minimum ceiling height from the bottom of the fireplace 55-1\/2\" natural gas \/ 67-1\/2\" propane (non-vented chase, pp.18, 21), minimum enclosure 72\" (vented chase, pp.23–29); recommended non-combustible facing area 39-1\/2\" x 41\" (p.22)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e33\" W x 28-5\/8\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eFront 36\"; back, sides, floor and top 0\"; top of a 90° bend 4\"; top of horizontal pipe 1-1\/2\", sides and bottom 1\"; vertical pipe 1\" (pp.21, 29, 110); facing: non-vented chase, any face material non-combustible (p.22); vented chase, combustible drywall allowed up to the opening (p.30); mantels: combustible mantel minimum heights not published by the manufacturer in text form; a combustible hearth may sit below the opening (p.28)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e25,000 \/ 16,750 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e25,000 \/ 20,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e52.35% MV \/ 54.24% IPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eTempered, with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e4\"\/7\" flex, 4\" x 6-5\/8\" rigid, or PVH58 power vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eChase venting and floor protection\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVented chase: V39EG front grill (36-1\/2\" x 3-5\/8\" opening, within 3\/4\" of the enclosure top) or V39EGS side grills (two 12-1\/2\" x 6-1\/8\" openings, both sides required); open top needs 2\" on three sides; minimum enclosure 72\".\u003c\/li\u003e\n\u003cli\u003eFloor: no hearth is required; over carpet or another combustible floor covering use a full-width metal or wood panel; with vinyl flooring use a 12\" hearth or raise the unit 24\".\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eTempered glass front\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eA flame display (one required): LOGF3 Fibre Split Oak log set, or the ZCV39GT glass tray with 15 lb (3 bags) of Z5GC bronze glass media\u003c\/li\u003e\n\u003cli\u003e4\"\/7\" direct vent pipe and termination (Kingsman Z-Flex or listed 4\" x 6-5\/8\" rigid with the ZDVDFA adapter), or a PVH58 power vent\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing in a non-vented chase\u003c\/li\u003e\n\u003cli\u003eFor a vented chase: V39EG \/ V39EGS grills or an open top\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan or IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZCV39S1BL hearth-mount 4\" wide surround\u003c\/li\u003e\n\u003cli\u003eZCV39S1PFBL picture frame 4\" wide surround\u003c\/li\u003e\n\u003cli\u003eZCV39S2PFBL picture frame 1-5\/8\" wide surround\u003c\/li\u003e\n\u003cli\u003eZCVTLK tile lip kit\u003c\/li\u003e\n\u003cli\u003eZCV39RLT traditional brick\u003c\/li\u003e\n\u003cli\u003eZCV39RLH herringbone brick\u003c\/li\u003e\n\u003cli\u003eZCV39RLS stacked brick\u003c\/li\u003e\n\u003cli\u003eZCV39PL porcelain reflective\u003c\/li\u003e\n\u003cli\u003eRBCB1 multi-coloured cannonballs\u003c\/li\u003e\n\u003cli\u003eZ46FK fan kit\u003c\/li\u003e\n\u003cli\u003eULK2 accent light kit\u003c\/li\u003e\n\u003cli\u003eZ2MT wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eGTRC millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eEGTRC IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCN IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCP IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCN IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCP IPI remote\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder\u003c\/li\u003e\n\u003cli\u003ePVH58 power vent\u003c\/li\u003e\n\u003cli\u003ePVH58FM flush-mount power vent\u003c\/li\u003e\n\u003cli\u003eV39EG front enclosure grill\u003c\/li\u003e\n\u003cli\u003eV39EGS side enclosure grills (both sides required)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/39ZCV-MAN19-16.pdf\"\u003eZCV39\/ZCV42 installation and operating manual (39ZCV-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/12\/21435-KM-B080-ZCV34-39-42ENG-Dec2025-FNL1-Web.pdf\"\u003eZCV34\/39\/42 brochure and specifications (Dec 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (ZCV39\/ZCV42 installation and operating manual (39ZCV-MAN19), cover and safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.5–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for manufactured\/mobile homes where local codes allow (mobile home section).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.6).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFraming, chase and clearances (pp.10–46)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFront clearance 36\"; 0\" at the back, sides, floor and top; minimum ceiling 55-1\/2\" (natural gas) \/ 67-1\/2\" (propane) from the bottom of the fireplace (non-vented); 72\" minimum enclosure with a vented chase.\u003c\/li\u003e\n\u003cli\u003eNo hearth is required.\u003c\/li\u003e\n\u003cli\u003eFacing: non-vented chase: any face material must be non-combustible, recommended area 39-1\/2\" x 41\" (p.22); vented chase: combustible drywall allowed up to the opening (p.30).\u003c\/li\u003e\n\u003cli\u003eMantels: combustible mantel minimum heights are not published by the manufacturer in text form; a combustible hearth may sit below the opening (p.28).\u003c\/li\u003e\n\u003cli\u003eVented chase: V39EG front grill (36-1\/2\" x 3-5\/8\" opening, within 3\/4\" of the enclosure top) or V39EGS side grills (two 12-1\/2\" x 6-1\/8\" openings, both sides required); open top needs 2\" on three sides; minimum enclosure 72\".\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinishing: surrounds, tile lip and doors (pp.47–58)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSurrounds: ZCV39S1BL hearth-mount 4\" wide (covers 40-5\/8\" W x 35\" H); ZCV39S1PFBL picture frame 4\" wide (covers 40-5\/8\" W x 37\" H); ZCV39S2PFBL picture frame 1-5\/8\" wide (covers 36-1\/8\" W x 32-1\/2\" H).\u003c\/li\u003e\n\u003cli\u003eTile lip kit ZCVTLK for tile or stone finished up to the opening.\u003c\/li\u003e\n\u003cli\u003eNever operate with the glass removed, cracked or broken; replacement glass must be tempered, at least 5 mm thick.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMedia, logs and accessories (pp.59–79)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eThe flame display is chosen separately: the LOGF3 Fibre Split Oak log set, or the ZCV39GT glass tray with bronze ember glass (pp.66–72).\u003c\/li\u003e\n\u003cli\u003eKeep the pilot visible and uncovered; use only Kingsman-listed media.\u003c\/li\u003e\n\u003cli\u003eThe Z46FK fan's speed control mounts outside the unit; a split receptacle supplies constant power and must be installed by an electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.80–90)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.82).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.82).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.82).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.82). Field conversion between natural gas and propane uses Kingsman kits 39ZCV-CKLP, -CKNG, -CKLPI, -CKNGI, -CKLP2 and -CKNG2, installed by a qualified agency (pp.86–89).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and electrical (pp.91–104)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.91–104).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eDo not wire 120 V to millivolt switches or thermostats; switch-wire length is limited by gauge.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.105–116)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: 4\"\/7\" Kingsman flex, 4\" x 6-5\/8\" rigid (DuraVent with adapter) or PVH58 power vent.\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 48\" (natural gas) \/ 60\" (propane), floor to vent centre; maximum vertical 43 ft; maximum horizontal 20 ft (with 7–20 ft of vertical rise; 12 ft at 6 ft vertical); 1\/4\" rise per 12\" of horizontal run.\u003c\/li\u003e\n\u003cli\u003eUp to two 45° bends in the horizontal run (18\" off the run each) plus two more 90° bends (36\" each); remove the flue restrictor for runs under 15 ft.\u003c\/li\u003e\n\u003cli\u003ePower venting: equivalent length up to 125 ft; downward runs are allowed only on IPI models without the cold-climate switch.\u003c\/li\u003e\n\u003cli\u003eKeep the termination 24\" from obstructions and flammables, terminate at least 18\" above the roof, and never recess it into the wall.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.9).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.6).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.6).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (ZCV39\/ZCV42 installation and operating manual (39ZCV-MAN19), p.122).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — ZCV39\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the ZCV39 need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: 0\" at the back, sides, floor and top, with 36\" clear in front. The unit measures 39-3\/8\" W x 37-11\/16\" H x 18-7\/16\" D. Framing depth is 18-1\/2\" for framing flush with the face of the unit, or 18\" with 1\/2\" drywall flush with the face. In a non-vented chase the ceiling must be at least 55-1\/2\" (natural gas) or 67-1\/2\" (propane) above the bottom of the fireplace; a vented chase must be at least 72\" tall. No hearth is required.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 4\"\/7\" Kingsman flex or 4\" x 6-5\/8\" rigid direct vent pipe, a co-linear kit (12 ft minimum, 43 ft maximum), or a PVH58 power vent (up to 125 ft plus six 90° elbows). Minimum vertical is 48\" (natural gas) or 60\" (propane) from the bottom of the fireplace, and the maximum is 43 ft. Horizontal runs go up to 20 ft with 7 to 20 ft of vertical rise, 12 ft at 6 ft of vertical, 15 ft at 25 ft and 10 ft at 30 ft, with at least 1\/4\" of rise per foot of horizontal run. Propane installations need an extra 1 ft of vertical rise before going horizontal.\u003c\/p\u003e\n\u003ch4\u003eCan the ZCV39 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It is offered here in natural gas (ZCV39N millivolt, ZCV39NE IPI) and propane IPI (ZCV39LPE) versions, rated 25,000 \/ 16,750 BTU\/h on natural gas and 25,000 \/ 20,000 BTU\/h on propane (max\/min). Field conversion uses Kingsman kits 39ZCV-CKLP, -CKNG, -CKLPI, -CKNGI, -CKLP2 and -CKNG2.\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models run on a 120 VAC adapter with a four-AA battery backup that keeps the fire working in an outage; the fan and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eIs a log set included?\u003c\/h4\u003e\u003cp\u003eNo. One flame display is required and sold separately: the LOGF3 five-piece Fibre Split Oak log set, or the ZCV39GT glass tray with 15 lb (three 5 lb bags) of Z5GC bronze glass media. RBCB1 cannonballs can be added on the glass tray.\u003c\/p\u003e\n\u003ch4\u003eCan it be installed in a bedroom?\u003c\/h4\u003e\u003cp\u003eYes. It is certified for installation in a bedroom or bed-sitting room; in Canada it must be installed with a listed millivolt thermostat. It is also approved for manufactured\/mobile homes where local codes allow.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912054313122,"sku":"ZCV39N","price":2955.96,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912054345890,"sku":"ZCV39NE","price":3367.72,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI","offer_id":50912054378658,"sku":"ZCV39LPE","price":3470.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/KingsmanWebsite-Images-ZCV343942-LogStackedBrick.jpg?v=1795038336"},{"product_id":"kingsman-zcv39h-heater-rated-clean-view-fireplace-zcv39h","title":"Kingsman ZCV39H Heater-Rated Clean View Fireplace ZCV39H","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman ZCV39H is a 39-inch Designer Clean View zero-clearance direct vent gas fireplace: a traditional fire framed by a clean, louver-free face. It is the mid-size member of the Clean View family, sized for living rooms and bedrooms, and installs flush on a wall, across a corner or in a bump-out chase.\u003c\/p\u003e\u003cp\u003eThe 33\" W x 28-5\/8\" H Robax or coated Neoceram ceramic glass shows the LOGF3 log set or the ZCV39GT glass tray with bronze ember glass. ZCV39RLT traditional brick, ZCV39RLH herringbone brick, ZCV39RLS stacked brick or ZCV39PL porcelain reflective liners set the style, and a hearth-mount or picture-frame surround or the ZCVTLK tile lip kit finishes the face. Input is 28,000 BTU\/h on natural gas and 29,000 BTU\/h on propane with Hi\/Lo adjustment, at a fireplace efficiency of 63.81% MV \/ 66.17% IPI (NG) and 66.82% \/ 68.65% (LP).\u003c\/p\u003e\u003cp\u003eA millivolt valve needs no house power and IPI ignition has battery backup, so both keep the fire going in a power outage. It vents 4\"\/7\" through the wall or roof, through a co-linear kit, or with a PVH58 power vent. Proflame remotes, wall thermostats and the Z46FK fan are available. The ZCV39 is the same fireplace with tempered glass.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigner Clean View face\u003c\/strong\u003e: no louvers; a clean frame around the glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance direct vent\u003c\/strong\u003e: 0\" at the back, sides, floor and top standoffs; 36\" in front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt or IPI valve\u003c\/strong\u003e: operates during a power failure, with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCeramic glass\u003c\/strong\u003e: 33\" W x 28-5\/8\" H viewing area; heater rated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 28,000 \/ 19,000 BTU\/h natural gas; 29,000 \/ 23,000 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 63.81% MV \/ 66.17% IPI (NG); 66.82% \/ 68.65% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame display\u003c\/strong\u003e: LOGF3 log set, ZCV39GT glass tray with bronze ember glass, RBCB1 cannonballs (glass tray required).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z46FK heat-activated with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounds (optional)\u003c\/strong\u003e: ZCV39S1BL hearth-mount 4\" wide (covers 40-5\/8\" W x 35\" H); ZCV39S1PFBL picture frame 4\" wide (covers 40-5\/8\" W x 37\" H); ZCV39S2PFBL picture frame 1-5\/8\" wide (covers 36-1\/8\" W x 32-1\/2\" H).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTile lip kit (optional)\u003c\/strong\u003e: ZCVTLK for a frameless finish.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: ZCV39RLT traditional brick, ZCV39RLH herringbone brick, ZCV39RLS stacked brick or ZCV39PL porcelain reflective.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccent lighting (optional)\u003c\/strong\u003e: ULK2 accent light kit (with the glass tray).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat (optional)\u003c\/strong\u003e: Z2MT wall-mount or Z80PT programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional)\u003c\/strong\u003e: thermostat on\/off, thermostatic modulating, thermostatic modulating with fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (IPI PF2 models)\u003c\/strong\u003e: flame-height modulation and multi-colour LED accent lighting control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVented chase option\u003c\/strong\u003e: V39EG front grill (36-1\/2\" x 3-5\/8\" opening, within 3\/4\" of the enclosure top) or V39EGS side grills (two 12-1\/2\" x 6-1\/8\" openings, both sides required); open top needs 2\" on three sides; minimum enclosure 72\".\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH for the IPI backup batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 \/ PVH58FM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: NG\/LP kits 39ZCV-CKLPH, -CKNGH, -CKLPHI, -CKNGHI, -CKLPH2 and -CKNGH2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and certification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19 \/ CSA 2.33-19 heater, CSA 2.17-2017; manufactured\/mobile home approved.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eZCV39NH \/ ZCV39LPH (millivolt); ZCV39NHE \/ ZCV39LPHE (IPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eZero-clearance Clean View direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e39-3\/8\" W x 37-11\/16\" H x 18-7\/16\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eFraming depth 18-1\/2\" for framing flush with the face of the unit, 18\" for 1\/2\" drywall flush with the face (pp.18, 23); framed opening width and height are not published by the manufacturer as labeled values; minimum ceiling height from the bottom of the fireplace 55-1\/2\" natural gas \/ 67-1\/2\" propane (non-vented chase, pp.18, 21), minimum enclosure 72\" (vented chase, pp.23–29); recommended non-combustible facing area 39-1\/2\" x 41\" (p.22)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e33\" W x 28-5\/8\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eFront 36\"; back, sides, floor and top 0\"; top of a 90° bend 4\"; top of horizontal pipe 1-1\/2\", sides and bottom 1\"; vertical pipe 1\" (pp.21, 29, 110); facing: non-vented chase, any face material non-combustible (p.22); vented chase, combustible drywall allowed up to the opening (p.30); mantels: combustible mantel minimum heights not published by the manufacturer in text form; a combustible hearth may sit below the opening (p.28)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e28,000 \/ 19,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e29,000 \/ 23,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e63.81% MV \/ 66.17% IPI (NG); 66.82% \/ 68.65% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic, with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e4\"\/7\" flex, 4\" x 6-5\/8\" rigid, or PVH58 power vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eChase venting and floor protection\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVented chase: V39EG front grill (36-1\/2\" x 3-5\/8\" opening, within 3\/4\" of the enclosure top) or V39EGS side grills (two 12-1\/2\" x 6-1\/8\" openings, both sides required); open top needs 2\" on three sides; minimum enclosure 72\".\u003c\/li\u003e\n\u003cli\u003eFloor: no hearth is required; over carpet or another combustible floor covering use a full-width metal or wood panel; with vinyl flooring use a 12\" hearth or raise the unit 24\".\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eCeramic glass front\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eA flame display (one required): LOGF3 Fibre Split Oak log set, or the ZCV39GT glass tray with 15 lb (3 bags) of Z5GC bronze glass media\u003c\/li\u003e\n\u003cli\u003e4\"\/7\" direct vent pipe and termination (Kingsman Z-Flex or listed 4\" x 6-5\/8\" rigid with the ZDVDFA adapter), or a PVH58 power vent\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing in a non-vented chase\u003c\/li\u003e\n\u003cli\u003eFor a vented chase: V39EG \/ V39EGS grills or an open top\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan or IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZCV39S1BL hearth-mount 4\" wide surround\u003c\/li\u003e\n\u003cli\u003eZCV39S1PFBL picture frame 4\" wide surround\u003c\/li\u003e\n\u003cli\u003eZCV39S2PFBL picture frame 1-5\/8\" wide surround\u003c\/li\u003e\n\u003cli\u003eZCVTLK tile lip kit\u003c\/li\u003e\n\u003cli\u003eZCV39RLT traditional brick\u003c\/li\u003e\n\u003cli\u003eZCV39RLH herringbone brick\u003c\/li\u003e\n\u003cli\u003eZCV39RLS stacked brick\u003c\/li\u003e\n\u003cli\u003eZCV39PL porcelain reflective\u003c\/li\u003e\n\u003cli\u003eRBCB1 multi-coloured cannonballs\u003c\/li\u003e\n\u003cli\u003eZ46FK fan kit\u003c\/li\u003e\n\u003cli\u003eULK2 accent light kit\u003c\/li\u003e\n\u003cli\u003eZ2MT wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eGTRC millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eEGTRC IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCN IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCP IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCN IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCP IPI remote\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder\u003c\/li\u003e\n\u003cli\u003ePVH58 power vent\u003c\/li\u003e\n\u003cli\u003ePVH58FM flush-mount power vent\u003c\/li\u003e\n\u003cli\u003eV39EG front enclosure grill\u003c\/li\u003e\n\u003cli\u003eV39EGS side enclosure grills (both sides required)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/39ZCV-MAN19-16.pdf\"\u003eZCV39\/ZCV42 installation and operating manual (39ZCV-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/12\/21435-KM-B080-ZCV34-39-42ENG-Dec2025-FNL1-Web.pdf\"\u003eZCV34\/39\/42 brochure and specifications (Dec 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (ZCV39\/ZCV42 installation and operating manual (39ZCV-MAN19), cover and safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.5–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for manufactured\/mobile homes where local codes allow (mobile home section).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.6).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFraming, chase and clearances (pp.10–46)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFront clearance 36\"; 0\" at the back, sides, floor and top; minimum ceiling 55-1\/2\" (natural gas) \/ 67-1\/2\" (propane) from the bottom of the fireplace (non-vented); 72\" minimum enclosure with a vented chase.\u003c\/li\u003e\n\u003cli\u003eNo hearth is required.\u003c\/li\u003e\n\u003cli\u003eFacing: non-vented chase: any face material must be non-combustible, recommended area 39-1\/2\" x 41\" (p.22); vented chase: combustible drywall allowed up to the opening (p.30).\u003c\/li\u003e\n\u003cli\u003eMantels: combustible mantel minimum heights are not published by the manufacturer in text form; a combustible hearth may sit below the opening (p.28).\u003c\/li\u003e\n\u003cli\u003eVented chase: V39EG front grill (36-1\/2\" x 3-5\/8\" opening, within 3\/4\" of the enclosure top) or V39EGS side grills (two 12-1\/2\" x 6-1\/8\" openings, both sides required); open top needs 2\" on three sides; minimum enclosure 72\".\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinishing: surrounds, tile lip and doors (pp.47–58)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSurrounds: ZCV39S1BL hearth-mount 4\" wide (covers 40-5\/8\" W x 35\" H); ZCV39S1PFBL picture frame 4\" wide (covers 40-5\/8\" W x 37\" H); ZCV39S2PFBL picture frame 1-5\/8\" wide (covers 36-1\/8\" W x 32-1\/2\" H).\u003c\/li\u003e\n\u003cli\u003eTile lip kit ZCVTLK for tile or stone finished up to the opening.\u003c\/li\u003e\n\u003cli\u003eNever operate with the glass removed, cracked or broken; replacement glass must be 5 mm Robax or coated Neoceram ceramic.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMedia, logs and accessories (pp.59–79)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eThe flame display is chosen separately: the LOGF3 Fibre Split Oak log set, or the ZCV39GT glass tray with bronze ember glass (pp.66–72).\u003c\/li\u003e\n\u003cli\u003eKeep the pilot visible and uncovered; use only Kingsman-listed media.\u003c\/li\u003e\n\u003cli\u003eThe Z46FK fan's speed control mounts outside the unit; a split receptacle supplies constant power and must be installed by an electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.80–90)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.82).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.82).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.82).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.82). Field conversion between natural gas and propane uses Kingsman kits 39ZCV-CKLPH, -CKNGH, -CKLPHI, -CKNGHI, -CKLPH2 and -CKNGH2, installed by a qualified agency (pp.86–89).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and electrical (pp.91–104)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.91–104).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eDo not wire 120 V to millivolt switches or thermostats; switch-wire length is limited by gauge.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.105–116)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: 4\"\/7\" Kingsman flex, 4\" x 6-5\/8\" rigid (DuraVent with adapter) or PVH58 power vent.\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 48\" (natural gas) \/ 60\" (propane), floor to vent centre; maximum vertical 43 ft; maximum horizontal 20 ft (with 7–20 ft of vertical rise; 12 ft at 6 ft vertical); 1\/4\" rise per 12\" of horizontal run.\u003c\/li\u003e\n\u003cli\u003eUp to two 45° bends in the horizontal run (18\" off the run each) plus two more 90° bends (36\" each); remove the flue restrictor for runs under 15 ft.\u003c\/li\u003e\n\u003cli\u003ePower venting: equivalent length up to 125 ft; downward runs are allowed only on IPI models without the cold-climate switch.\u003c\/li\u003e\n\u003cli\u003eKeep the termination 24\" from obstructions and flammables, terminate at least 18\" above the roof, and never recess it into the wall.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.9).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.6).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.6).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (ZCV39\/ZCV42 installation and operating manual (39ZCV-MAN19), p.122).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — ZCV39H\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the ZCV39H need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: 0\" at the back, sides, floor and top, with 36\" clear in front. The unit measures 39-3\/8\" W x 37-11\/16\" H x 18-7\/16\" D. Framing depth is 18-1\/2\" for framing flush with the face of the unit, or 18\" with 1\/2\" drywall flush with the face. In a non-vented chase the ceiling must be at least 55-1\/2\" (natural gas) or 67-1\/2\" (propane) above the bottom of the fireplace; a vented chase must be at least 72\" tall. No hearth is required.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 4\"\/7\" Kingsman flex or 4\" x 6-5\/8\" rigid direct vent pipe, a co-linear kit (12 ft minimum, 43 ft maximum), or a PVH58 power vent (up to 125 ft plus six 90° elbows). Minimum vertical is 48\" (natural gas) or 60\" (propane) from the bottom of the fireplace, and the maximum is 43 ft. Horizontal runs go up to 20 ft with 7 to 20 ft of vertical rise, 12 ft at 6 ft of vertical, 15 ft at 25 ft and 10 ft at 30 ft, with at least 1\/4\" of rise per foot of horizontal run. Propane installations need an extra 1 ft of vertical rise before going horizontal.\u003c\/p\u003e\n\u003ch4\u003eCan the ZCV39H run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It is offered here in natural gas (ZCV39NH millivolt, ZCV39NHE IPI) and propane (ZCV39LPH millivolt, ZCV39LPHE IPI) versions, rated 28,000 \/ 19,000 BTU\/h on natural gas and 29,000 \/ 23,000 BTU\/h on propane (max\/min). Field conversion uses Kingsman kits 39ZCV-CKLPH, -CKNGH, -CKLPHI, -CKNGHI, -CKLPH2 and -CKNGH2.\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models run on a 120 VAC adapter with a four-AA battery backup that keeps the fire working in an outage; the fan and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eIs a log set included?\u003c\/h4\u003e\u003cp\u003eNo. One flame display is required and sold separately: the LOGF3 five-piece Fibre Split Oak log set, or the ZCV39GT glass tray with 15 lb (three 5 lb bags) of Z5GC bronze glass media. RBCB1 cannonballs can be added on the glass tray.\u003c\/p\u003e\n\u003ch4\u003eCan it be installed in a bedroom?\u003c\/h4\u003e\u003cp\u003eYes. It is certified for installation in a bedroom or bed-sitting room; in Canada it must be installed with a listed millivolt thermostat. It is also approved for manufactured\/mobile homes where local codes allow.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912054411426,"sku":"ZCV39NH","price":3883.32,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912054444194,"sku":"ZCV39LPH","price":3987.17,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912054476962,"sku":"ZCV39NHE","price":4298.7,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI","offer_id":50912054509730,"sku":"ZCV39LPHE","price":4402.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/KingsmanWebsite-Images-ZCV343942-LogTraditionalBrick_f98b8f7a-61b4-4f53-a887-1f959e5e2236.jpg?v=1795038337"},{"product_id":"kingsman-zcv42-clean-view-direct-vent-gas-fireplace-zcv42","title":"Kingsman ZCV42 Clean View Direct Vent Gas Fireplace ZCV42","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman ZCV42 is a 42-inch Designer Clean View zero-clearance direct vent gas fireplace: a traditional fire framed by a clean, louver-free face. It is the largest member of the Clean View family, sized for living rooms, family rooms and bedrooms, and installs flush on a wall, across a corner or in a bump-out chase.\u003c\/p\u003e\u003cp\u003eThe 37-1\/8\" W x 31-3\/4\" H tempered glass shows the LOGF3 log set or the ZCV42GT glass tray with bronze ember glass, with RBCB1 cannonballs as an option on the tray. ZCV42RLT traditional brick, ZCV42RLH herringbone brick, ZCV42RLS stacked brick or ZCV42PL porcelain reflective liners set the style, and a hearth-mount or picture-frame surround or the ZCVTLK tile lip kit finishes the face. Input is 25,000 BTU\/h on natural gas or propane with Hi\/Lo adjustment, at a fireplace efficiency of 52.86% MV \/ 54.95% IPI.\u003c\/p\u003e\u003cp\u003eA millivolt valve needs no house power and IPI ignition has battery backup, so both keep the fire going in a power outage. It vents 4\"\/7\" through the wall or roof, through a co-linear kit, or with a PVH58 power vent. Proflame remotes, wall thermostats and the Z46FK fan are available. The ZCV42H is the same fireplace with ceramic glass.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigner Clean View face\u003c\/strong\u003e: no louvers; a clean frame around the glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance direct vent\u003c\/strong\u003e: 0\" at the back, sides, floor and top standoffs; 36\" in front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt or IPI valve\u003c\/strong\u003e: operates during a power failure, with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTempered glass\u003c\/strong\u003e: 37-1\/8\" W x 31-3\/4\" H viewing area.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 25,000 \/ 16,500 BTU\/h natural gas; 25,000 \/ 19,500 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 52.86% MV \/ 54.95% IPI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame display\u003c\/strong\u003e: LOGF3 log set, ZCV42GT glass tray with bronze ember glass, RBCB1 cannonballs (glass tray required).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z46FK heat-activated with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounds (optional)\u003c\/strong\u003e: ZCV42S1BL hearth-mount 4\" wide (covers 44-11\/16\" W x 38-1\/8\" H); ZCV42S1PFBL picture frame 4\" wide (covers 44-11\/16\" W x 40-1\/8\" H); ZCV42S2PFBL picture frame 1-5\/8\" wide (covers 40-3\/16\" W x 35-5\/8\" H).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTile lip kit (optional)\u003c\/strong\u003e: ZCVTLK for a frameless finish.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: ZCV42RLT traditional brick, ZCV42RLH herringbone brick, ZCV42RLS stacked brick or ZCV42PL porcelain reflective.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccent lighting (optional)\u003c\/strong\u003e: ULK2 accent light kit (with the glass tray).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat (optional)\u003c\/strong\u003e: Z2MT wall-mount or Z80PT programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional)\u003c\/strong\u003e: thermostat on\/off, thermostatic modulating, thermostatic modulating with fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (IPI PF2 models)\u003c\/strong\u003e: flame-height modulation and multi-colour LED accent lighting control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVented chase option\u003c\/strong\u003e: V39EG front grill (36-1\/2\" x 3-5\/8\" opening, within 3\/4\" of the enclosure top) or V39EGS side grills (two 12-1\/2\" x 6-1\/8\" openings, both sides required); open top needs 2\" on three sides; minimum enclosure 72\".\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH for the IPI backup batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 \/ PVH58FM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: NG\/LP kits 42ZCV-CKLP, -CKNG, -CKLPI, -CKNGI, -CKLP2 and -CKNG2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and certification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19 \/ CSA 2.33-19 heater, CSA 2.17-2017; manufactured\/mobile home approved.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eZCV42N \/ ZCV42LP (millivolt); ZCV42NE \/ ZCV42LPE (IPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eZero-clearance Clean View direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e42-7\/16\" W x 40-7\/8\" H x 18-7\/16\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eFraming depth 18-1\/2\" for framing flush with the face of the unit, 18\" for 1\/2\" drywall flush with the face (pp.33, 38); framed opening width and height are not published by the manufacturer as labeled values; minimum ceiling height from the bottom of the fireplace 59-1\/2\" natural gas \/ 71-1\/2\" propane (non-vented chase, p.36), minimum enclosure 72\" (vented chase, pp.38–44); recommended non-combustible facing area 42-5\/8\" x 44\" (p.37)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e37-1\/8\" W x 31-3\/4\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eFront 36\"; back, sides, floor and top 0\"; top of a 90° bend 3-1\/2\"; top of horizontal pipe 1-1\/2\", sides and bottom 1\"; vertical pipe 1\" (pp.36, 44); facing: non-vented chase, any face material non-combustible (p.37); vented chase, combustible drywall allowed up to the opening (p.45); mantels: combustible mantel minimum heights not published by the manufacturer in text form; a combustible hearth may sit below the opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e25,000 \/ 16,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e25,000 \/ 19,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e52.86% MV \/ 54.95% IPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eTempered, with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e4\"\/7\" flex, 4\" x 6-5\/8\" rigid, or PVH58 power vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eChase venting and floor protection\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVented chase: V39EG front grill (36-1\/2\" x 3-5\/8\" opening, within 3\/4\" of the enclosure top) or V39EGS side grills (two 12-1\/2\" x 6-1\/8\" openings, both sides required); open top needs 2\" on three sides; minimum enclosure 72\".\u003c\/li\u003e\n\u003cli\u003eFloor: no hearth is required; over carpet or another combustible floor covering use a full-width metal or wood panel; with vinyl flooring use a 12\" hearth or raise the unit 24\".\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eTempered glass front\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eA flame display (one required): LOGF3 Fibre Split Oak log set, or the ZCV42GT glass tray with 20 lb (4 bags) of Z5GC bronze glass media\u003c\/li\u003e\n\u003cli\u003e4\"\/7\" direct vent pipe and termination (Kingsman Z-Flex or listed 4\" x 6-5\/8\" rigid with the ZDVDFA adapter), or a PVH58 power vent\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing in a non-vented chase\u003c\/li\u003e\n\u003cli\u003eFor a vented chase: V39EG \/ V39EGS grills or an open top\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan or IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZCV42S1BL hearth-mount 4\" wide surround\u003c\/li\u003e\n\u003cli\u003eZCV42S1PFBL picture frame 4\" wide surround\u003c\/li\u003e\n\u003cli\u003eZCV42S2PFBL picture frame 1-5\/8\" wide surround\u003c\/li\u003e\n\u003cli\u003eZCVTLK tile lip kit\u003c\/li\u003e\n\u003cli\u003eZCV42RLT traditional brick\u003c\/li\u003e\n\u003cli\u003eZCV42RLH herringbone brick\u003c\/li\u003e\n\u003cli\u003eZCV42RLS stacked brick\u003c\/li\u003e\n\u003cli\u003eZCV42PL porcelain reflective\u003c\/li\u003e\n\u003cli\u003eRBCB1 multi-coloured cannonballs\u003c\/li\u003e\n\u003cli\u003eZ46FK fan kit\u003c\/li\u003e\n\u003cli\u003eULK2 accent light kit\u003c\/li\u003e\n\u003cli\u003eZ2MT wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eGTRC millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eEGTRC IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCN IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCP IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCN IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCP IPI remote\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder\u003c\/li\u003e\n\u003cli\u003ePVH58 power vent\u003c\/li\u003e\n\u003cli\u003ePVH58FM flush-mount power vent\u003c\/li\u003e\n\u003cli\u003eV39EG front enclosure grill\u003c\/li\u003e\n\u003cli\u003eV39EGS side enclosure grills (both sides required)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/39ZCV-MAN19-16.pdf\"\u003eZCV39\/ZCV42 installation and operating manual (39ZCV-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/12\/21435-KM-B080-ZCV34-39-42ENG-Dec2025-FNL1-Web.pdf\"\u003eZCV34\/39\/42 brochure and specifications (Dec 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (ZCV39\/ZCV42 installation and operating manual (39ZCV-MAN19), cover and safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.5–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for manufactured\/mobile homes where local codes allow (mobile home section).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.6).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFraming, chase and clearances (pp.10–46)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFront clearance 36\"; 0\" at the back, sides, floor and top; minimum ceiling 59-1\/2\" (natural gas) \/ 71-1\/2\" (propane) from the bottom of the fireplace (non-vented); 72\" minimum enclosure with a vented chase.\u003c\/li\u003e\n\u003cli\u003eNo hearth is required.\u003c\/li\u003e\n\u003cli\u003eFacing: non-vented chase: any face material must be non-combustible, recommended area 42-5\/8\" x 44\" (p.37); vented chase: combustible drywall allowed up to the opening (p.45).\u003c\/li\u003e\n\u003cli\u003eMantels: combustible mantel minimum heights are not published by the manufacturer in text form; a combustible hearth may sit below the opening.\u003c\/li\u003e\n\u003cli\u003eVented chase: V39EG front grill (36-1\/2\" x 3-5\/8\" opening, within 3\/4\" of the enclosure top) or V39EGS side grills (two 12-1\/2\" x 6-1\/8\" openings, both sides required); open top needs 2\" on three sides; minimum enclosure 72\".\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinishing: surrounds, tile lip and doors (pp.47–58)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSurrounds: ZCV42S1BL hearth-mount 4\" wide (covers 44-11\/16\" W x 38-1\/8\" H); ZCV42S1PFBL picture frame 4\" wide (covers 44-11\/16\" W x 40-1\/8\" H); ZCV42S2PFBL picture frame 1-5\/8\" wide (covers 40-3\/16\" W x 35-5\/8\" H).\u003c\/li\u003e\n\u003cli\u003eTile lip kit ZCVTLK for tile or stone finished up to the opening.\u003c\/li\u003e\n\u003cli\u003eNever operate with the glass removed, cracked or broken; replacement glass must be tempered, at least 5 mm thick.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMedia, logs and accessories (pp.59–79)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eThe flame display is chosen separately: the LOGF3 Fibre Split Oak log set, or the ZCV42GT glass tray with bronze ember glass (pp.66–72).\u003c\/li\u003e\n\u003cli\u003eKeep the pilot visible and uncovered; use only Kingsman-listed media.\u003c\/li\u003e\n\u003cli\u003eThe Z46FK fan's speed control mounts outside the unit; a split receptacle supplies constant power and must be installed by an electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.80–90)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.82).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.82).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.82).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.82). Field conversion between natural gas and propane uses Kingsman kits 42ZCV-CKLP, -CKNG, -CKLPI, -CKNGI, -CKLP2 and -CKNG2, installed by a qualified agency (pp.86–89).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and electrical (pp.91–104)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.91–104).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eDo not wire 120 V to millivolt switches or thermostats; switch-wire length is limited by gauge.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.105–116)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: 4\"\/7\" Kingsman flex, 4\" x 6-5\/8\" rigid (DuraVent with adapter) or PVH58 power vent.\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 52-1\/2\" (natural gas) \/ 64-1\/2\" (propane), floor to vent centre; maximum vertical 43 ft; maximum horizontal 20 ft (with 7–20 ft of vertical rise; 12 ft at 6 ft vertical); 1\/4\" rise per 12\" of horizontal run.\u003c\/li\u003e\n\u003cli\u003eUp to two 45° bends in the horizontal run (18\" off the run each) plus two more 90° bends (36\" each); remove the flue restrictor for runs under 15 ft.\u003c\/li\u003e\n\u003cli\u003ePower venting: equivalent length up to 125 ft; downward runs are allowed only on IPI models without the cold-climate switch.\u003c\/li\u003e\n\u003cli\u003eKeep the termination 24\" from obstructions and flammables, terminate at least 18\" above the roof, and never recess it into the wall.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.9).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.6).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.6).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (ZCV39\/ZCV42 installation and operating manual (39ZCV-MAN19), p.122).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — ZCV42\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the ZCV42 need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: 0\" at the back, sides, floor and top, with 36\" clear in front. The unit measures 42-7\/16\" W x 40-7\/8\" H x 18-7\/16\" D. Framing depth is 18-1\/2\" for framing flush with the face of the unit, or 18\" with 1\/2\" drywall flush with the face. In a non-vented chase the ceiling must be at least 59-1\/2\" (natural gas) or 71-1\/2\" (propane) above the bottom of the fireplace; a vented chase must be at least 72\" tall. No hearth is required.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 4\"\/7\" Kingsman flex or 4\" x 6-5\/8\" rigid direct vent pipe, a co-linear kit (12 ft minimum, 43 ft maximum), or a PVH58 power vent (up to 125 ft plus six 90° elbows). Minimum vertical is 52-1\/2\" (natural gas) or 64-1\/2\" (propane) from the bottom of the fireplace, and the maximum is 43 ft. Horizontal runs go up to 20 ft with 7 to 20 ft of vertical rise, 12 ft at 6 ft of vertical, 15 ft at 25 ft and 10 ft at 30 ft, with at least 1\/4\" of rise per foot of horizontal run. Propane installations need an extra 1 ft of vertical rise before going horizontal.\u003c\/p\u003e\n\u003ch4\u003eCan the ZCV42 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It is offered here in natural gas (ZCV42N millivolt, ZCV42NE IPI) and propane (ZCV42LP millivolt, ZCV42LPE IPI) versions, rated 25,000 \/ 16,500 BTU\/h on natural gas and 25,000 \/ 19,500 BTU\/h on propane (max\/min). Field conversion uses Kingsman kits 42ZCV-CKLP, -CKNG, -CKLPI, -CKNGI, -CKLP2 and -CKNG2.\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models run on a 120 VAC adapter with a four-AA battery backup that keeps the fire working in an outage; the fan and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eIs a log set included?\u003c\/h4\u003e\u003cp\u003eNo. One flame display is required and sold separately: the LOGF3 five-piece Fibre Split Oak log set, or the ZCV42GT glass tray with 20 lb (four 5 lb bags) of Z5GC bronze glass media. RBCB1 cannonballs can be added on the glass tray.\u003c\/p\u003e\n\u003ch4\u003eCan it be installed in a bedroom?\u003c\/h4\u003e\u003cp\u003eYes. It is certified for installation in a bedroom or bed-sitting room; in Canada it must be installed with a listed millivolt thermostat. It is also approved for manufactured\/mobile homes where local codes allow.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912055197858,"sku":"ZCV42N","price":3314.59,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912055230626,"sku":"ZCV42LP","price":3419.64,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912055263394,"sku":"ZCV42NE","price":3731.18,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI","offer_id":50912055296162,"sku":"ZCV42LPE","price":3835.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/KingsmanWebsite-Images-ZCV343942-LogTraditionalBrick_d5db4282-c77a-4fd9-a2a0-a7949b99f555.jpg?v=1795038385"},{"product_id":"kingsman-zcv42h-heater-rated-clean-view-fireplace-zcv42h","title":"Kingsman ZCV42H Heater-Rated Clean View Fireplace ZCV42H","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman ZCV42H is a 42-inch Designer Clean View zero-clearance direct vent gas fireplace: a traditional fire framed by a clean, louver-free face. It is the largest member of the Clean View family, sized for living rooms and bedrooms, and installs flush on a wall, across a corner or in a bump-out chase.\u003c\/p\u003e\u003cp\u003eThe 37-1\/8\" W x 31-3\/4\" H Robax or coated Neoceram ceramic glass shows the LOGF3 log set or the ZCV42GT glass tray with bronze ember glass. ZCV42RLT traditional brick, ZCV42RLH herringbone brick, ZCV42RLS stacked brick or ZCV42PL porcelain reflective liners set the style, and a hearth-mount or picture-frame surround or the ZCVTLK tile lip kit finishes the face. Input is 29,500 BTU\/h on natural gas and 29,000 BTU\/h on propane with Hi\/Lo adjustment, at a fireplace efficiency of 64.53% MV \/ 66.48% IPI (NG) and 66.65% \/ 68.77% (LP).\u003c\/p\u003e\u003cp\u003eA millivolt valve needs no house power and IPI ignition has battery backup, so both keep the fire going in a power outage. It vents 4\"\/7\" through the wall or roof, through a co-linear kit, or with a PVH58 power vent. Proflame remotes, wall thermostats and the Z46FK fan are available. The ZCV42 is the same fireplace with tempered glass.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigner Clean View face\u003c\/strong\u003e: no louvers; a clean frame around the glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance direct vent\u003c\/strong\u003e: 0\" at the back, sides, floor and top standoffs; 36\" in front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt or IPI valve\u003c\/strong\u003e: operates during a power failure, with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCeramic glass\u003c\/strong\u003e: 37-1\/8\" W x 31-3\/4\" H viewing area; heater rated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 29,500 \/ 20,000 BTU\/h natural gas; 29,000 \/ 23,000 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 64.53% MV \/ 66.48% IPI (NG); 66.65% \/ 68.77% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame display\u003c\/strong\u003e: LOGF3 log set, ZCV42GT glass tray with bronze ember glass, RBCB1 cannonballs (glass tray required).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z46FK heat-activated with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounds (optional)\u003c\/strong\u003e: ZCV42S1BL hearth-mount 4\" wide (covers 44-11\/16\" W x 38-1\/8\" H); ZCV42S1PFBL picture frame 4\" wide (covers 44-11\/16\" W x 40-1\/8\" H); ZCV42S2PFBL picture frame 1-5\/8\" wide (covers 40-3\/16\" W x 35-5\/8\" H).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTile lip kit (optional)\u003c\/strong\u003e: ZCVTLK for a frameless finish.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: ZCV42RLT traditional brick, ZCV42RLH herringbone brick, ZCV42RLS stacked brick or ZCV42PL porcelain reflective.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccent lighting (optional)\u003c\/strong\u003e: ULK2 accent light kit (with the glass tray).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat (optional)\u003c\/strong\u003e: Z2MT wall-mount or Z80PT programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional)\u003c\/strong\u003e: thermostat on\/off, thermostatic modulating, thermostatic modulating with fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (IPI PF2 models)\u003c\/strong\u003e: flame-height modulation and multi-colour LED accent lighting control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVented chase option\u003c\/strong\u003e: V39EG front grill (36-1\/2\" x 3-5\/8\" opening, within 3\/4\" of the enclosure top) or V39EGS side grills (two 12-1\/2\" x 6-1\/8\" openings, both sides required); open top needs 2\" on three sides; minimum enclosure 72\".\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH for the IPI backup batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 \/ PVH58FM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: NG\/LP kits 42ZCV-CKLPH, -CKNGH, -CKLPHI, -CKNGHI, -CKLPH2 and -CKNGH2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals and certification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19 \/ CSA 2.33-19 heater, CSA 2.17-2017; manufactured\/mobile home approved.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eZCV42NH \/ ZCV42LPH (millivolt); ZCV42NHE \/ ZCV42LPHE (IPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eZero-clearance Clean View direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e42-7\/16\" W x 40-7\/8\" H x 18-7\/16\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eFraming depth 18-1\/2\" for framing flush with the face of the unit, 18\" for 1\/2\" drywall flush with the face (pp.33, 38); framed opening width and height are not published by the manufacturer as labeled values; minimum ceiling height from the bottom of the fireplace 59-1\/2\" natural gas \/ 71-1\/2\" propane (non-vented chase, p.36), minimum enclosure 72\" (vented chase, pp.38–44); recommended non-combustible facing area 42-5\/8\" x 44\" (p.37)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e37-1\/8\" W x 31-3\/4\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eFront 36\"; back, sides, floor and top 0\"; top of a 90° bend 3-1\/2\"; top of horizontal pipe 1-1\/2\", sides and bottom 1\"; vertical pipe 1\" (pp.36, 44); facing: non-vented chase, any face material non-combustible (p.37); vented chase, combustible drywall allowed up to the opening (p.45); mantels: combustible mantel minimum heights not published by the manufacturer in text form; a combustible hearth may sit below the opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e29,500 \/ 20,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e29,000 \/ 23,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e64.53% MV \/ 66.48% IPI (NG); 66.65% \/ 68.77% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic, with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e4\"\/7\" flex, 4\" x 6-5\/8\" rigid, or PVH58 power vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eChase venting and floor protection\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVented chase: V39EG front grill (36-1\/2\" x 3-5\/8\" opening, within 3\/4\" of the enclosure top) or V39EGS side grills (two 12-1\/2\" x 6-1\/8\" openings, both sides required); open top needs 2\" on three sides; minimum enclosure 72\".\u003c\/li\u003e\n\u003cli\u003eFloor: no hearth is required; over carpet or another combustible floor covering use a full-width metal or wood panel; with vinyl flooring use a 12\" hearth or raise the unit 24\".\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eCeramic glass front\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eA flame display (one required): LOGF3 Fibre Split Oak log set, or the ZCV42GT glass tray with 20 lb (4 bags) of Z5GC bronze glass media\u003c\/li\u003e\n\u003cli\u003e4\"\/7\" direct vent pipe and termination (Kingsman Z-Flex or listed 4\" x 6-5\/8\" rigid with the ZDVDFA adapter), or a PVH58 power vent\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing in a non-vented chase\u003c\/li\u003e\n\u003cli\u003eFor a vented chase: V39EG \/ V39EGS grills or an open top\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for the fan or IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZCV42S1BL hearth-mount 4\" wide surround\u003c\/li\u003e\n\u003cli\u003eZCV42S1PFBL picture frame 4\" wide surround\u003c\/li\u003e\n\u003cli\u003eZCV42S2PFBL picture frame 1-5\/8\" wide surround\u003c\/li\u003e\n\u003cli\u003eZCVTLK tile lip kit\u003c\/li\u003e\n\u003cli\u003eZCV42RLT traditional brick\u003c\/li\u003e\n\u003cli\u003eZCV42RLH herringbone brick\u003c\/li\u003e\n\u003cli\u003eZCV42RLS stacked brick\u003c\/li\u003e\n\u003cli\u003eZCV42PL porcelain reflective\u003c\/li\u003e\n\u003cli\u003eRBCB1 multi-coloured cannonballs\u003c\/li\u003e\n\u003cli\u003eZ46FK fan kit\u003c\/li\u003e\n\u003cli\u003eULK2 accent light kit\u003c\/li\u003e\n\u003cli\u003eZ2MT wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eGTRC millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTMRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCN millivolt remote\u003c\/li\u003e\n\u003cli\u003eGTFRCP millivolt remote\u003c\/li\u003e\n\u003cli\u003eEGTRC IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCN IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTMRCP IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCN IPI remote\u003c\/li\u003e\n\u003cli\u003eEGTFRCP IPI remote\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder\u003c\/li\u003e\n\u003cli\u003ePVH58 power vent\u003c\/li\u003e\n\u003cli\u003ePVH58FM flush-mount power vent\u003c\/li\u003e\n\u003cli\u003eV39EG front enclosure grill\u003c\/li\u003e\n\u003cli\u003eV39EGS side enclosure grills (both sides required)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/39ZCV-MAN19-16.pdf\"\u003eZCV39\/ZCV42 installation and operating manual (39ZCV-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/12\/21435-KM-B080-ZCV34-39-42ENG-Dec2025-FNL1-Web.pdf\"\u003eZCV34\/39\/42 brochure and specifications (Dec 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (ZCV39\/ZCV42 installation and operating manual (39ZCV-MAN19), cover and safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.5–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for manufactured\/mobile homes where local codes allow (mobile home section).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.6).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFraming, chase and clearances (pp.10–46)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFront clearance 36\"; 0\" at the back, sides, floor and top; minimum ceiling 59-1\/2\" (natural gas) \/ 71-1\/2\" (propane) from the bottom of the fireplace (non-vented); 72\" minimum enclosure with a vented chase.\u003c\/li\u003e\n\u003cli\u003eNo hearth is required.\u003c\/li\u003e\n\u003cli\u003eFacing: non-vented chase: any face material must be non-combustible, recommended area 42-5\/8\" x 44\" (p.37); vented chase: combustible drywall allowed up to the opening (p.45).\u003c\/li\u003e\n\u003cli\u003eMantels: combustible mantel minimum heights are not published by the manufacturer in text form; a combustible hearth may sit below the opening.\u003c\/li\u003e\n\u003cli\u003eVented chase: V39EG front grill (36-1\/2\" x 3-5\/8\" opening, within 3\/4\" of the enclosure top) or V39EGS side grills (two 12-1\/2\" x 6-1\/8\" openings, both sides required); open top needs 2\" on three sides; minimum enclosure 72\".\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinishing: surrounds, tile lip and doors (pp.47–58)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSurrounds: ZCV42S1BL hearth-mount 4\" wide (covers 44-11\/16\" W x 38-1\/8\" H); ZCV42S1PFBL picture frame 4\" wide (covers 44-11\/16\" W x 40-1\/8\" H); ZCV42S2PFBL picture frame 1-5\/8\" wide (covers 40-3\/16\" W x 35-5\/8\" H).\u003c\/li\u003e\n\u003cli\u003eTile lip kit ZCVTLK for tile or stone finished up to the opening.\u003c\/li\u003e\n\u003cli\u003eNever operate with the glass removed, cracked or broken; replacement glass must be 5 mm Robax or coated Neoceram ceramic.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMedia, logs and accessories (pp.59–79)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eThe flame display is chosen separately: the LOGF3 Fibre Split Oak log set, or the ZCV42GT glass tray with bronze ember glass (pp.66–72).\u003c\/li\u003e\n\u003cli\u003eKeep the pilot visible and uncovered; use only Kingsman-listed media.\u003c\/li\u003e\n\u003cli\u003eThe Z46FK fan's speed control mounts outside the unit; a split receptacle supplies constant power and must be installed by an electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.80–90)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.82).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.82).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.82).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.82). Field conversion between natural gas and propane uses Kingsman kits 42ZCV-CKLPH, -CKNGH, -CKLPHI, -CKNGHI, -CKLPH2 and -CKNGH2, installed by a qualified agency (pp.86–89).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and electrical (pp.91–104)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.91–104).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eDo not wire 120 V to millivolt switches or thermostats; switch-wire length is limited by gauge.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.105–116)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: 4\"\/7\" Kingsman flex, 4\" x 6-5\/8\" rigid (DuraVent with adapter) or PVH58 power vent.\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 52-1\/2\" (natural gas) \/ 64-1\/2\" (propane), floor to vent centre; maximum vertical 43 ft; maximum horizontal 20 ft (with 7–20 ft of vertical rise; 12 ft at 6 ft vertical); 1\/4\" rise per 12\" of horizontal run.\u003c\/li\u003e\n\u003cli\u003eUp to two 45° bends in the horizontal run (18\" off the run each) plus two more 90° bends (36\" each); remove the flue restrictor for runs under 15 ft.\u003c\/li\u003e\n\u003cli\u003ePower venting: equivalent length up to 125 ft; downward runs are allowed only on IPI models without the cold-climate switch.\u003c\/li\u003e\n\u003cli\u003eKeep the termination 24\" from obstructions and flammables, terminate at least 18\" above the roof, and never recess it into the wall.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.9).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.6).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.6).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (ZCV39\/ZCV42 installation and operating manual (39ZCV-MAN19), p.122).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — ZCV42H\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the ZCV42H need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: 0\" at the back, sides, floor and top, with 36\" clear in front. The unit measures 42-7\/16\" W x 40-7\/8\" H x 18-7\/16\" D. Framing depth is 18-1\/2\" for framing flush with the face of the unit, or 18\" with 1\/2\" drywall flush with the face. In a non-vented chase the ceiling must be at least 59-1\/2\" (natural gas) or 71-1\/2\" (propane) above the bottom of the fireplace; a vented chase must be at least 72\" tall. No hearth is required.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 4\"\/7\" Kingsman flex or 4\" x 6-5\/8\" rigid direct vent pipe, a co-linear kit (12 ft minimum, 43 ft maximum), or a PVH58 power vent (up to 125 ft plus six 90° elbows). Minimum vertical is 52-1\/2\" (natural gas) or 64-1\/2\" (propane) from the bottom of the fireplace, and the maximum is 43 ft. Horizontal runs go up to 20 ft with 7 to 20 ft of vertical rise, 12 ft at 6 ft of vertical, 15 ft at 25 ft and 10 ft at 30 ft, with at least 1\/4\" of rise per foot of horizontal run. Propane installations need an extra 1 ft of vertical rise before going horizontal.\u003c\/p\u003e\n\u003ch4\u003eCan the ZCV42H run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It is offered here in natural gas (ZCV42NH millivolt, ZCV42NHE IPI) and propane (ZCV42LPH millivolt, ZCV42LPHE IPI) versions, rated 29,500 \/ 20,000 BTU\/h on natural gas and 29,000 \/ 23,000 BTU\/h on propane (max\/min). Field conversion uses Kingsman kits 42ZCV-CKLPH, -CKNGH, -CKLPHI, -CKNGHI, -CKLPH2 and -CKNGH2.\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models run on a 120 VAC adapter with a four-AA battery backup that keeps the fire working in an outage; the fan and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eIs a log set included?\u003c\/h4\u003e\u003cp\u003eNo. One flame display is required and sold separately: the LOGF3 five-piece Fibre Split Oak log set, or the ZCV42GT glass tray with 20 lb (four 5 lb bags) of Z5GC bronze glass media. RBCB1 cannonballs can be added on the glass tray.\u003c\/p\u003e\n\u003ch4\u003eCan it be installed in a bedroom?\u003c\/h4\u003e\u003cp\u003eYes. It is certified for installation in a bedroom or bed-sitting room; in Canada it must be installed with a listed millivolt thermostat. It is also approved for manufactured\/mobile homes where local codes allow.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912055328930,"sku":"ZCV42NH","price":4732.19,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912055361698,"sku":"ZCV42LPH","price":4834.83,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912055394466,"sku":"ZCV42NHE","price":5145.16,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI","offer_id":50912055427234,"sku":"ZCV42LPHE","price":5247.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/KingsmanWebsite-Images-ZCV343942-LogStackedBrick_e97a0bdb-155b-4729-931e-1e7c33053d9e.jpg?v=1795038386"},{"product_id":"kingsman-mcvp42-peninsula-direct-vent-gas-fireplace-mcvp42","title":"Kingsman MCVP42 Peninsula Direct Vent Gas Fireplace MCVP42","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman MCVP42 is a 42-inch three-sided peninsula direct vent gas fireplace from Kingsman's multi-sided Clean View range. Its glass wraps the front and both ends, so the fire can anchor the end of a half-wall or room divider and be enjoyed from three directions.\u003c\/p\u003e\u003cp\u003eIt is a dedicated Clean View appliance: no louvers, just a clean frame around the glass. Choose the flame display: the M42LOG4 eight-piece oak set on the M42LG log grate (natural gas), or the MP42GT glass tray with bronze ember glass, multi-coloured cannonballs or the M42LOG3 six-piece driftwood set. Traditional brick or porcelain reflective liners and ULK3 accent lighting (with the glass tray) complete the look.\u003c\/p\u003e\u003cp\u003eInput is 30,250 BTU\/h on natural gas and 28,500 BTU\/h on propane with Hi\/Lo adjustment, and Kingsman lists a fireplace efficiency (FE) of 53.00% MV \/ 54.63% IPI (NG); 53.82% \/ 55.32% (LP). This model uses tempered glass and is the value choice of the pair.\u003c\/p\u003e\u003cp\u003eA millivolt valve (no house power needed) or IPI electronic ignition with battery backup both keep the fire going during a power failure. Wall thermostats and Proflame remotes, including thermostatic, modulating and light\/fan-control versions, are available.\u003c\/p\u003e\u003cp\u003eVenting is 5\"\/8\" direct vent (Kingsman Z-Flex 5\"\/8\" or a listed rigid system), horizontal or vertical, with PVH58 power vent compatibility for long runs.\u003c\/p\u003e\u003cp\u003eThe MCVP42 peninsula is the right pick when the fireplace ends a wall or divider; for a fire between two rooms, see the MCVST42 see-through.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Clean View appliance\u003c\/strong\u003e: three-sided peninsula design with no louvers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect vent\u003c\/strong\u003e: sealed combustion, 5\"\/8\" venting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt or IPI valve\u003c\/strong\u003e: operates during a power failure with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTempered glass\u003c\/strong\u003e: heater rated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 30,250 \/ 21,000 BTU\/h natural gas; 28,500 \/ 23,000 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 53.00% MV \/ 54.63% IPI (NG); 53.82% \/ 55.32% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlass tray (optional)\u003c\/strong\u003e: MP42GT for bronze glass media, cannonballs and the driftwood log set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLog sets (optional)\u003c\/strong\u003e: M42LOG4 oak 8-piece (with the M42LG log grate, natural gas only) or M42LOG3 driftwood 6-piece (with the glass tray).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccent lighting (optional)\u003c\/strong\u003e: ULK3 two-lamp light kit, used with the glass tray.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: MP42PL porcelain reflective or MP42RLT traditional brick.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTile lip kit (optional)\u003c\/strong\u003e: 42MCVP-TLK.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat (optional)\u003c\/strong\u003e: Z2MT wall-mount millivolt or Z80PT programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional)\u003c\/strong\u003e: thermostat on\/off, thermostatic modulating, and modulating with light control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH for the IPI backup batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 \/ PVH58FM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: kits 42MP-CKLP \/ -CKNG (millivolt) and 42MP-CKLPI \/ -CKLP2 \/ -CKNGI \/ -CKNG2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eMCVP42N \/ MCVP42LP (millivolt); MCVP42NE (IPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eMulti-sided (three-sided peninsula) direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e43-1\/16\" W x 42-1\/4\" H x 24-1\/2\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer as labeled values. Framing goes to the standoffs (0\" back and top) with the enclosure ceiling at least 61\" above the bottom of the fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer as labeled values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e24\" in front and at the open sides; back and top standoffs 0\"; floor 0\"; ceiling at least 61\" above the bottom of the fireplace; 90° bend in the enclosure 2\"; vertical pipe 1\"; horizontal pipe 1-1\/2\" top, 1\" sides and bottom (manual p.17); combustible mantel may begin 11-3\/16\" above the top of the opening, adjacent wall at least 1-1\/2\" from the standoff (p.16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e30,250 \/ 21,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e28,500 \/ 23,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e53.00% MV \/ 54.63% IPI (NG); 53.82% \/ 55.32% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eTempered, with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e5\"\/8\" direct vent, flex or rigid; PVH58 power vent compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFacing: face materials must be non-combustible; drywall may sit flush with the top, and side facing attaches to the standoffs only (pp.11, 14).\u003c\/li\u003e\n\u003cli\u003eFloor: no hearth is required; with vinyl flooring use a 12\" hearth or raise the unit 24\"; carpet needs a metal or wood panel.\u003c\/li\u003e\n\u003cli\u003eAppliance weight: not listed in the manual text.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eTempered glass on all viewing sides\u003c\/li\u003e\n\u003cli\u003eSafety screen barriers\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eA flame display: M42LG log grate with M42LOG4 oak logs (natural gas), or the MP42GT glass tray with 10 lb (2 bags) of Z5GC bronze glass media, RBCB1 cannonballs or M42LOG3 driftwood logs\u003c\/li\u003e\n\u003cli\u003e5\"\/8\" direct vent pipe and termination (Kingsman Z-Flex 5\"\/8\" or a listed rigid system with the Z58DFA adapter where required)\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e42MVB258 pilot shield for the glass tray and log grate\u003c\/li\u003e\n\u003cli\u003eULK3 light kit\u003c\/li\u003e\n\u003cli\u003eMP42PL porcelain reflective\u003c\/li\u003e\n\u003cli\u003eMP42RLT traditional brick\u003c\/li\u003e\n\u003cli\u003e42MCVP-TLK tile lip kit\u003c\/li\u003e\n\u003cli\u003eZ2MT \/ Z80PT wall thermostats\u003c\/li\u003e\n\u003cli\u003eProflame remotes (GT \/ EGT series)\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder\u003c\/li\u003e\n\u003cli\u003ePVH58 \/ PVH58FM power vent\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/42MCVP-MAN19.pdf\"\u003eMCVP42 installation and operating manual (42MCVP-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2017\/03\/19717-KM-B084-MCVP42ENG-June2024-FNL1-Web.pdf\"\u003eMCVP42 brochure and specifications (June 2024)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (MCVP42 installation and operating manual (42MCVP-MAN19), information chapter). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.4–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for manufactured\/mobile homes where local codes allow (information chapter).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation, framing and clearances (pp.10–39)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eClearances: 24\" in front and at the open sides; 0\" at the back and top standoffs and floor; ceiling at least 61\".\u003c\/li\u003e\n\u003cli\u003eHorizontal vent framing: 55\" (natural gas) \/ 79\" (propane) from the bottom of the fireplace to the vent centre.\u003c\/li\u003e\n\u003cli\u003eFacing: face materials must be non-combustible; drywall may sit flush with the top, and side facing attaches to the standoffs only (pp.11, 14).\u003c\/li\u003e\n\u003cli\u003eMantel: a combustible mantel may begin 11-3\/16\" above the top of the opening; adjacent wall at least 1-1\/2\" from the standoff (p.16).\u003c\/li\u003e\n\u003cli\u003eNo hearth is required; vinyl flooring needs a 12\" hearth or a 24\" raise.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMedia, liners and accessories (pp.10–39)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eGlass tray MP42GT (not used with the brick liner on the MCVP42) or the M42LG log grate, which includes two grates, lava rock, embers and wool.\u003c\/li\u003e\n\u003cli\u003eUse only the log set approved for the grate or tray you choose, and keep the pilot uncovered.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm tempered, sealed with silicone rated to 500°F; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas and maintenance (pp.40–51)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.42).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.42).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.42).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.42). Field conversion between natural gas and propane uses Kingsman kits 42MP-CKLP \/ -CKNG (millivolt) and 42MP-CKLPI \/ -CKLP2 \/ -CKNGI \/ -CKNG2 (IPI), installed by a qualified agency (pp.47–49).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eProflame controls (pp.52–65)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.52–65).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eDo not wire 120 V to millivolt switches or thermostats; switch-wire length is limited by gauge (e.g. 18 AWG up to 40 ft).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.66–76)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: Kingsman Z-Flex 5\"\/8\" or approved 5\"\/8\" direct vent systems (e.g. MG-DuraVent, Selkirk Direct-Temp); a 9\" round hole is needed through masonry, 12\" x 12\" framing in combustible walls.\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 55\" (natural gas) \/ 79\" (propane) from the bottom of the fireplace to the vent centre; maximum vertical 43 ft; maximum horizontal 20 ft (with 7 ft of vertical).\u003c\/li\u003e\n\u003cli\u003eUp to two 45° bends in the horizontal run (18\" each) plus two more 90° bends (36\" each); remove the restrictor for runs under 15 ft.\u003c\/li\u003e\n\u003cli\u003ePVH58 \/ PVH58FM power vent approved; downward runs are not allowed on millivolt models, and IPI models must not use the cold-climate switch with power venting.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.8).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.7).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (MCVP42 installation and operating manual (42MCVP-MAN19), p.81).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — MCVP42\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the MCVP42 need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: framing goes to the standoffs with 0\" at the back and top and 0\" to the floor, with 24\" clear in front and at the open sides. The enclosure ceiling must be at least 61\" above the bottom of the fireplace. The unit measures 43-1\/16\" W × 42-1\/4\" H × 24-1\/2\" D.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 5\"\/8\" direct vent pipe, flex or rigid. The vent needs a minimum vertical rise of 55\" (natural gas) or 79\" (propane) from the bottom of the fireplace, and runs go up to 43 ft vertical or 20 ft horizontal with 7 ft of vertical. It is also compatible with the PVH58 power vent.\u003c\/p\u003e\n\u003ch4\u003eCan the MCVP42 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It comes as MCVP42N \/ MCVP42LP (millivolt) and MCVP42NE (IPI), rated 30,250 \/ 21,000 BTU\/h (max\/min) on natural gas and 28,500 \/ 23,000 BTU\/h on propane. Field conversion kits are 42MP-CKLP (millivolt) or 42MP-CKLPI \/ 42MP-CKLP2 (IPI).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models keep the fire running on four AA backup batteries; the fans and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eWhat's the warranty?\u003c\/h4\u003e\u003cp\u003eDefective components are covered for parts and labour for the first year after installation, except accent light bulbs, gasketing, glass fronts and paint. The heat exchanger, combustion chamber and burner carry a limited lifetime warranty for as long as the original owner owns the fireplace; after the first year the defective part is exchanged, and labour and freight are not covered.\u003c\/p\u003e\n\u003ch4\u003eHow high must a mantel be?\u003c\/h4\u003e\u003cp\u003eA combustible mantel may begin 11-3\/16\" above the top of the opening, and an adjacent wall must be at least 1-1\/2\" from the standoff.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912056377506,"sku":"MCVP42N","price":6159.46,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912056410274,"sku":"MCVP42LP","price":6260.89,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912056443042,"sku":"MCVP42NE","price":6572.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/MCVP42-1.jpg?v=1795038436"},{"product_id":"kingsman-mcvp42h-heater-rated-peninsula-fireplace-mcvp42h","title":"Kingsman MCVP42H Heater-Rated Peninsula Fireplace MCVP42H","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman MCVP42H is a 42-inch three-sided peninsula direct vent gas fireplace from Kingsman's multi-sided Clean View range. Its glass wraps the front and both ends, so the fire can anchor the end of a half-wall or room divider and be enjoyed from three directions.\u003c\/p\u003e\u003cp\u003eIt is a dedicated Clean View appliance: no louvers, just a clean frame around the glass. Choose the flame display: the M42LOG4 eight-piece oak set on the M42LG log grate (natural gas), or the MP42GT glass tray with bronze ember glass, multi-coloured cannonballs or the M42LOG3 six-piece driftwood set. Traditional brick or porcelain reflective liners and ULK3 accent lighting (with the glass tray) complete the look.\u003c\/p\u003e\u003cp\u003eInput is 31,250 BTU\/h on natural gas and 29,000 BTU\/h on propane with Hi\/Lo adjustment, and Kingsman lists a fireplace efficiency (FE) of 64.55% MV \/ 66.49% IPI (NG); 65.66% \/ 67.42% (LP). This H model uses ceramic glass and is the heater-rated, higher-efficiency choice.\u003c\/p\u003e\u003cp\u003eA millivolt valve (no house power needed) or IPI electronic ignition with battery backup both keep the fire going during a power failure. Wall thermostats and Proflame remotes, including thermostatic, modulating and light\/fan-control versions, are available.\u003c\/p\u003e\u003cp\u003eVenting is 5\"\/8\" direct vent (Kingsman Z-Flex 5\"\/8\" or a listed rigid system), horizontal or vertical, with PVH58 power vent compatibility for long runs.\u003c\/p\u003e\u003cp\u003eThe MCVP42 peninsula is the right pick when the fireplace ends a wall or divider; for a fire between two rooms, see the MCVST42 see-through.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Clean View appliance\u003c\/strong\u003e: three-sided peninsula design with no louvers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect vent\u003c\/strong\u003e: sealed combustion, 5\"\/8\" venting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt or IPI valve\u003c\/strong\u003e: operates during a power failure with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCeramic (Robax or coated Neoceram) glass\u003c\/strong\u003e: heater rated, higher efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 31,250 \/ 21,250 BTU\/h natural gas; 29,000 \/ 23,000 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 64.55% MV \/ 66.49% IPI (NG); 65.66% \/ 67.42% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlass tray (optional)\u003c\/strong\u003e: MP42GT for bronze glass media, cannonballs and the driftwood log set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLog sets (optional)\u003c\/strong\u003e: M42LOG4 oak 8-piece (with the M42LG log grate, natural gas only) or M42LOG3 driftwood 6-piece (with the glass tray).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccent lighting (optional)\u003c\/strong\u003e: ULK3 two-lamp light kit, used with the glass tray.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: MP42PL porcelain reflective or MP42RLT traditional brick.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTile lip kit (optional)\u003c\/strong\u003e: 42MCVP-TLK.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat (optional)\u003c\/strong\u003e: Z2MT wall-mount millivolt or Z80PT programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional)\u003c\/strong\u003e: thermostat on\/off, thermostatic modulating, and modulating with light control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH for the IPI backup batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 \/ PVH58FM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: kits 42MP-CKLP \/ -CKNG (millivolt) and 42MP-CKLPI \/ -CKLP2 \/ -CKNGI \/ -CKNG2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eMCVP42NH \/ MCVP42LPH (millivolt); MCVP42NHE \/ MCVP42LPHE (IPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eMulti-sided (three-sided peninsula) direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e43-1\/16\" W x 42-1\/4\" H x 24-1\/2\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer as labeled values. Framing goes to the standoffs (0\" back and top) with the enclosure ceiling at least 61\" above the bottom of the fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer as labeled values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e24\" in front and at the open sides; back and top standoffs 0\"; floor 0\"; ceiling at least 61\" above the bottom of the fireplace; 90° bend in the enclosure 2\"; vertical pipe 1\"; horizontal pipe 1-1\/2\" top, 1\" sides and bottom (manual p.17); combustible mantel may begin 11-3\/16\" above the top of the opening, adjacent wall at least 1-1\/2\" from the standoff (p.16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e31,250 \/ 21,250 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e29,000 \/ 23,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e64.55% MV \/ 66.49% IPI (NG); 65.66% \/ 67.42% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic (Robax or coated Neoceram), with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e5\"\/8\" direct vent, flex or rigid; PVH58 power vent compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFacing: face materials must be non-combustible; drywall may sit flush with the top, and side facing attaches to the standoffs only (pp.11, 14).\u003c\/li\u003e\n\u003cli\u003eFloor: no hearth is required; with vinyl flooring use a 12\" hearth or raise the unit 24\"; carpet needs a metal or wood panel.\u003c\/li\u003e\n\u003cli\u003eAppliance weight: not listed in the manual text.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eCeramic (Robax or coated Neoceram) glass on all viewing sides\u003c\/li\u003e\n\u003cli\u003eSafety screen barriers\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eA flame display: M42LG log grate with M42LOG4 oak logs (natural gas), or the MP42GT glass tray with 10 lb (2 bags) of Z5GC bronze glass media, RBCB1 cannonballs or M42LOG3 driftwood logs\u003c\/li\u003e\n\u003cli\u003e5\"\/8\" direct vent pipe and termination (Kingsman Z-Flex 5\"\/8\" or a listed rigid system with the Z58DFA adapter where required)\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for IPI models\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e42MVB258 pilot shield for the glass tray and log grate\u003c\/li\u003e\n\u003cli\u003eULK3 light kit\u003c\/li\u003e\n\u003cli\u003eMP42PL porcelain reflective\u003c\/li\u003e\n\u003cli\u003eMP42RLT traditional brick\u003c\/li\u003e\n\u003cli\u003e42MCVP-TLK tile lip kit\u003c\/li\u003e\n\u003cli\u003eZ2MT \/ Z80PT wall thermostats\u003c\/li\u003e\n\u003cli\u003eProflame remotes (GT \/ EGT series)\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder\u003c\/li\u003e\n\u003cli\u003ePVH58 \/ PVH58FM power vent\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/42MCVP-MAN19.pdf\"\u003eMCVP42 installation and operating manual (42MCVP-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2017\/03\/19717-KM-B084-MCVP42ENG-June2024-FNL1-Web.pdf\"\u003eMCVP42 brochure and specifications (June 2024)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (MCVP42 installation and operating manual (42MCVP-MAN19), information chapter). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.4–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for manufactured\/mobile homes where local codes allow (information chapter).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation, framing and clearances (pp.10–39)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eClearances: 24\" in front and at the open sides; 0\" at the back and top standoffs and floor; ceiling at least 61\".\u003c\/li\u003e\n\u003cli\u003eHorizontal vent framing: 55\" (natural gas) \/ 79\" (propane) from the bottom of the fireplace to the vent centre.\u003c\/li\u003e\n\u003cli\u003eFacing: face materials must be non-combustible; drywall may sit flush with the top, and side facing attaches to the standoffs only (pp.11, 14).\u003c\/li\u003e\n\u003cli\u003eMantel: a combustible mantel may begin 11-3\/16\" above the top of the opening; adjacent wall at least 1-1\/2\" from the standoff (p.16).\u003c\/li\u003e\n\u003cli\u003eNo hearth is required; vinyl flooring needs a 12\" hearth or a 24\" raise.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMedia, liners and accessories (pp.10–39)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eGlass tray MP42GT (not used with the brick liner on the MCVP42) or the M42LG log grate, which includes two grates, lava rock, embers and wool.\u003c\/li\u003e\n\u003cli\u003eUse only the log set approved for the grate or tray you choose, and keep the pilot uncovered.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm Robax or coated Neoceram ceramic, sealed with silicone rated to 500°F; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas and maintenance (pp.40–51)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.42).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.42).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.42).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.42). Field conversion between natural gas and propane uses Kingsman kits 42MP-CKLP \/ -CKNG (millivolt) and 42MP-CKLPI \/ -CKLP2 \/ -CKNGI \/ -CKNG2 (IPI), installed by a qualified agency (pp.47–49).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eProflame controls (pp.52–65)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.52–65).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eDo not wire 120 V to millivolt switches or thermostats; switch-wire length is limited by gauge (e.g. 18 AWG up to 40 ft).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.66–76)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: Kingsman Z-Flex 5\"\/8\" or approved 5\"\/8\" direct vent systems (e.g. MG-DuraVent, Selkirk Direct-Temp); a 9\" round hole is needed through masonry, 12\" x 12\" framing in combustible walls.\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 55\" (natural gas) \/ 79\" (propane) from the bottom of the fireplace to the vent centre; maximum vertical 43 ft; maximum horizontal 20 ft (with 7 ft of vertical).\u003c\/li\u003e\n\u003cli\u003eUp to two 45° bends in the horizontal run (18\" each) plus two more 90° bends (36\" each); remove the restrictor for runs under 15 ft.\u003c\/li\u003e\n\u003cli\u003ePVH58 \/ PVH58FM power vent approved; downward runs are not allowed on millivolt models, and IPI models must not use the cold-climate switch with power venting.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.8).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.7).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (MCVP42 installation and operating manual (42MCVP-MAN19), p.81).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — MCVP42H\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the MCVP42H need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: framing goes to the standoffs with 0\" at the back and top and 0\" to the floor, with 24\" clear in front and at the open sides. The enclosure ceiling must be at least 61\" above the bottom of the fireplace. The unit measures 43-1\/16\" W × 42-1\/4\" H × 24-1\/2\" D.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 5\"\/8\" direct vent pipe, flex or rigid. The vent needs a minimum vertical rise of 55\" (natural gas) or 79\" (propane) from the bottom of the fireplace, and runs go up to 43 ft vertical or 20 ft horizontal with 7 ft of vertical. It is also compatible with the PVH58 power vent.\u003c\/p\u003e\n\u003ch4\u003eCan the MCVP42H run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It comes as MCVP42NH \/ MCVP42LPH (millivolt) and MCVP42NHE \/ MCVP42LPHE (IPI), rated 31,250 \/ 21,250 BTU\/h (max\/min) on natural gas and 29,000 \/ 23,000 BTU\/h on propane. Field conversion kits are 42MP-CKLP (millivolt) or 42MP-CKLPI \/ 42MP-CKLP2 (IPI).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models keep the fire running on four AA backup batteries; the fans and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eWhat's the warranty?\u003c\/h4\u003e\u003cp\u003eDefective components are covered for parts and labour for the first year after installation, except accent light bulbs, gasketing, glass fronts and paint. The heat exchanger, combustion chamber and burner carry a limited lifetime warranty for as long as the original owner owns the fireplace; after the first year the defective part is exchanged, and labour and freight are not covered.\u003c\/p\u003e\n\u003ch4\u003eHow high must a mantel be?\u003c\/h4\u003e\u003cp\u003eA combustible mantel may begin 11-3\/16\" above the top of the opening, and an adjacent wall must be at least 1-1\/2\" from the standoff.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912056475810,"sku":"MCVP42NH","price":9050.21,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912056508578,"sku":"MCVP42LPH","price":9151.64,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912056541346,"sku":"MCVP42NHE","price":9463.18,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI","offer_id":50912056574114,"sku":"MCVP42LPHE","price":9565.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/MCVP42-2_c9f41c34-4d60-459f-9377-887703b026cf.jpg?v=1795038437"},{"product_id":"kingsman-mcvst42-see-through-gas-fireplace-mcvst42","title":"Kingsman MCVST42 See-Through Gas Fireplace MCVST42","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman MCVST42 is a 42-inch two-sided see-through direct vent gas fireplace from Kingsman's multi-sided Clean View range. Glass on both faces lets one fire serve two rooms, such as a living room and dining room, or a kitchen and family room.\u003c\/p\u003e\u003cp\u003eIt is a dedicated Clean View appliance: no louvers, just a clean frame around the glass. Choose the flame display: the M42LOG4 eight-piece oak set on the M42LG log grate (natural gas), or the MST42GT glass tray with bronze ember glass, multi-coloured cannonballs or the M42LOG3 six-piece driftwood set. Traditional brick or porcelain reflective liners and ULK3 accent lighting (with the glass tray) complete the look.\u003c\/p\u003e\u003cp\u003eInput is 30,250 BTU\/h on natural gas and 29,000 BTU\/h on propane with Hi\/Lo adjustment, and Kingsman lists a fireplace efficiency (FE) of 57.56% MV \/ 59.55% IPI (NG); 58.56% \/ 55.32% (LP). This model uses tempered glass and is the value choice of the pair.\u003c\/p\u003e\u003cp\u003eA millivolt valve (no house power needed) or IPI electronic ignition with battery backup both keep the fire going during a power failure. Wall thermostats and Proflame remotes, including thermostatic, modulating and light\/fan-control versions, are available.\u003c\/p\u003e\u003cp\u003eVenting is 5\"\/8\" direct vent (Kingsman Z-Flex 5\"\/8\" or a listed rigid system), horizontal or vertical, with PVH58 power vent compatibility for long runs.\u003c\/p\u003e\u003cp\u003eThe MCVST42 is the right pick for a fire shared between two rooms; for a three-sided view at the end of a wall, see the MCVP42 peninsula.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Clean View appliance\u003c\/strong\u003e: two-sided see-through design with no louvers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect vent\u003c\/strong\u003e: sealed combustion, 5\"\/8\" venting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt or IPI valve\u003c\/strong\u003e: operates during a power failure with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTempered glass\u003c\/strong\u003e: heater rated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 30,250 \/ 20,750 BTU\/h natural gas; 29,000 \/ 23,000 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 57.56% MV \/ 59.55% IPI (NG); 58.56% \/ 55.32% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlass tray (optional)\u003c\/strong\u003e: MST42GT for bronze glass media, cannonballs and the driftwood log set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLog sets (optional)\u003c\/strong\u003e: M42LOG4 oak 8-piece (with the M42LG log grate, natural gas only) or M42LOG3 driftwood 6-piece (with the glass tray).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccent lighting (optional)\u003c\/strong\u003e: ULK3 two-lamp light kit, used with the glass tray.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: MST42PL porcelain reflective or MST42RLT traditional brick.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z46FK heat activated with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounds (optional)\u003c\/strong\u003e: ZCV42S1BL hearth-mount, ZCV42S1PFBL 4\" picture frame or ZCV42S2PFBL 1-5\/8\" picture frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTile lip kit (optional)\u003c\/strong\u003e: ZCVTLK.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat (optional)\u003c\/strong\u003e: Z2MT wall-mount millivolt or Z80PT programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional)\u003c\/strong\u003e: thermostat on\/off, thermostatic modulating, and modulating with fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH for the IPI backup batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 \/ PVH58FM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: kits 42MST-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKLP2 \/ -CKNGI \/ -CKNG2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eMCVST42N \/ MCVST42LP (millivolt); MCVST42NE \/ MCVST42LPE (IPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eMulti-sided (two-sided see-through) direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e43-1\/16\" W x 51-1\/4\" H x 24-1\/4\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer as labeled values. Framing goes to the standoffs (0\" back and top) with the enclosure ceiling at least 67\" above the bottom of the fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e33-11\/16\" W x 27-3\/16\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e24\" in front (both viewing sides); back and top standoffs 0\"; floor 0\"; ceiling at least 67\" above the bottom of the fireplace; 90° bend in the enclosure 2\"; vertical pipe 1\"; horizontal pipe 1-1\/2\" top, 1\" sides and bottom (manual p.28); combustible mantel may begin 12-5\/8\" above the top of the opening, adjacent wall at least 1-1\/2\" from the standoff (p.27)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e30,250 \/ 20,750 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e29,000 \/ 23,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e57.56% MV \/ 59.55% IPI (NG); 58.56% \/ 55.32% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eTempered, with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e5\"\/8\" direct vent, flex or rigid; PVH58 power vent compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFacing: face materials must be non-combustible; concrete board recommended 44\" x 53\"; a recessed combustible wall may sit no more than 3\" above the header (p.14).\u003c\/li\u003e\n\u003cli\u003eFloor: no hearth is required; with vinyl flooring use a 12\" hearth or raise the unit 24\"; carpet needs a metal or wood panel.\u003c\/li\u003e\n\u003cli\u003eAppliance weight: not listed in the manual text.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eTempered glass on all viewing sides\u003c\/li\u003e\n\u003cli\u003eSafety screen barriers\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eA flame display: M42LG log grate with M42LOG4 oak logs (natural gas), or the MST42GT glass tray with 10 lb (2 bags) of Z5GC bronze glass media, RBCB1 cannonballs or M42LOG3 driftwood logs\u003c\/li\u003e\n\u003cli\u003e5\"\/8\" direct vent pipe and termination (Kingsman Z-Flex 5\"\/8\" or a listed rigid system with the Z58DFA adapter where required)\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for IPI models and the fan kit\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e42MVB258 pilot shield for the glass tray and log grate\u003c\/li\u003e\n\u003cli\u003eULK3 light kit\u003c\/li\u003e\n\u003cli\u003eMST42PL porcelain reflective\u003c\/li\u003e\n\u003cli\u003eMST42RLT traditional brick\u003c\/li\u003e\n\u003cli\u003eZCV42S1BL hearth-mount\u003c\/li\u003e\n\u003cli\u003eZCV42S1PFBL 4\" picture frame\u003c\/li\u003e\n\u003cli\u003eZCV42S2PFBL 1-5\/8\" picture frame\u003c\/li\u003e\n\u003cli\u003eZ46FK fan kit\u003c\/li\u003e\n\u003cli\u003eZCVTLK tile lip kit\u003c\/li\u003e\n\u003cli\u003eZ2MT \/ Z80PT wall thermostats\u003c\/li\u003e\n\u003cli\u003eProflame remotes (GT \/ EGT series)\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder\u003c\/li\u003e\n\u003cli\u003ePVH58 \/ PVH58FM power vent\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/42MCVST-MAN19-8.pdf\"\u003eMCVST42 installation and operating manual (42MCVST-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2017\/03\/19717-KM-B085-MCVST42ENG-June2024-FNL1-Web-1.pdf\"\u003eMCVST42 brochure and specifications (June 2024)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (MCVST42 installation and operating manual (42MCVST-MAN19), information chapter). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.2–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for manufactured\/mobile homes where local codes allow (information chapter).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation, framing and clearances (pp.10–28)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eClearances: 24\" in front (both viewing sides); 0\" at the back and top standoffs and floor; ceiling at least 67\".\u003c\/li\u003e\n\u003cli\u003eHorizontal vent framing: 58-1\/2\" (natural gas) \/ 70-1\/2\" (propane) from the bottom of the fireplace, plus 1\/4\" per foot of rise.\u003c\/li\u003e\n\u003cli\u003eFacing: face materials must be non-combustible; concrete board recommended 44\" x 53\"; a recessed combustible wall may sit no more than 3\" above the header (p.14).\u003c\/li\u003e\n\u003cli\u003eMantel: a combustible mantel may begin 12-5\/8\" above the top of the opening; adjacent wall at least 1-1\/2\" from the standoff (p.27).\u003c\/li\u003e\n\u003cli\u003eNo hearth is required; vinyl flooring needs a 12\" hearth or a 24\" raise.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMedia, liners and accessories (pp.29–60)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eGlass tray MST42GT (not used with the brick liner on the MCVP42) or the M42LG log grate, which includes two grates, lava rock, embers and wool.\u003c\/li\u003e\n\u003cli\u003eUse only the log set approved for the grate or tray you choose, and keep the pilot uncovered.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm tempered, sealed with silicone rated to 500°F; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas and maintenance (pp.29–60)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.52).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.52).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.52).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.52). Field conversion between natural gas and propane uses Kingsman kits 42MST-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKLP2 \/ -CKNGI \/ -CKNG2 (IPI), installed by a qualified agency (pp.57–59).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eProflame controls (pp.61–75)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.61–75).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eDo not wire 120 V to millivolt switches or thermostats; switch-wire length is limited by gauge (e.g. 18 AWG up to 40 ft).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.76–84)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: Kingsman Z-Flex 5\"\/8\" or approved 5\"\/8\" direct vent systems (e.g. MG-DuraVent, Selkirk Direct-Temp); a 9\" round hole is needed through masonry, 12\" x 12\" framing in combustible walls.\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 58-1\/2\" (natural gas) \/ 70-1\/2\" (propane) from the bottom of the fireplace, plus 1\/4\" per foot of rise; maximum vertical 43 ft; maximum horizontal 20 ft (with 7 ft of vertical). Run limits follow the sibling MCVP42 manual's 5\"\/8\" table.\u003c\/li\u003e\n\u003cli\u003eUp to two 45° bends in the horizontal run (18\" each) plus two more 90° bends (36\" each); remove the restrictor for runs under 15 ft.\u003c\/li\u003e\n\u003cli\u003ePVH58 \/ PVH58FM power vent approved; downward runs are not allowed on millivolt models, and IPI models must not use the cold-climate switch with power venting.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.8).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.7).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (MCVST42 installation and operating manual (42MCVST-MAN19), p.89).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — MCVST42\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the MCVST42 need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: framing goes to the standoffs with 0\" at the back and top and 0\" to the floor, with 24\" clear in front of both viewing sides. The enclosure ceiling must be at least 67\" above the bottom of the fireplace. The unit measures 43-1\/16\" W × 51-1\/4\" H × 24-1\/4\" D.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 5\"\/8\" direct vent pipe, flex or rigid. The vent needs a minimum vertical rise of 58-1\/2\" (natural gas) or 70-1\/2\" (propane) from the bottom of the fireplace, and runs go up to 43 ft vertical or 20 ft horizontal with 7 ft of vertical. It is also compatible with the PVH58 power vent.\u003c\/p\u003e\n\u003ch4\u003eCan the MCVST42 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It comes as MCVST42N \/ MCVST42LP (millivolt) and MCVST42NE \/ MCVST42LPE (IPI), rated 30,250 \/ 20,750 BTU\/h (max\/min) on natural gas and 29,000 \/ 23,000 BTU\/h on propane. Field conversion kits are 42MST-CKLP (millivolt) or 42MST-CKLPI \/ 42MST-CKLP2 (IPI).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models keep the fire running on four AA backup batteries; the fans and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eWhat's the warranty?\u003c\/h4\u003e\u003cp\u003eDefective components are covered for parts and labour for the first year after installation, except accent light bulbs, gasketing, glass fronts and paint. The heat exchanger, combustion chamber and burner carry a limited lifetime warranty for as long as the original owner owns the fireplace; after the first year the defective part is exchanged, and labour and freight are not covered.\u003c\/p\u003e\n\u003ch4\u003eHow high must a mantel be?\u003c\/h4\u003e\u003cp\u003eA combustible mantel may begin 12-5\/8\" above the top of the opening, and an adjacent wall must be at least 1-1\/2\" from the standoff.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912058114210,"sku":"MCVST42N","price":6304.36,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912058146978,"sku":"MCVST42LP","price":6413.03,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912058179746,"sku":"MCVST42NE","price":6720.95,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI","offer_id":50912058212514,"sku":"MCVST42LPE","price":6851.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/MCVST42-1.jpg?v=1795038482"},{"product_id":"kingsman-mcvst42h-heater-rated-see-through-fireplace-mcvst42h","title":"Kingsman MCVST42H Heater See-Through Gas Fireplace MCVST42H","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman MCVST42H is a 42-inch two-sided see-through direct vent gas fireplace from Kingsman's multi-sided Clean View range. Glass on both faces lets one fire serve two rooms, such as a living room and dining room, or a kitchen and family room.\u003c\/p\u003e\u003cp\u003eIt is a dedicated Clean View appliance: no louvers, just a clean frame around the glass. Choose the flame display: the M42LOG4 eight-piece oak set on the M42LG log grate (natural gas), or the MST42GT glass tray with bronze ember glass, multi-coloured cannonballs or the M42LOG3 six-piece driftwood set. Traditional brick or porcelain reflective liners and ULK3 accent lighting (with the glass tray) complete the look.\u003c\/p\u003e\u003cp\u003eInput is 31,000 BTU\/h on natural gas and 29,250 BTU\/h on propane with Hi\/Lo adjustment, and Kingsman lists a fireplace efficiency (FE) of 66.45% MV \/ 68.58% IPI (NG); 67.88% \/ 70.36% (LP). This H model uses ceramic glass and is the heater-rated, higher-efficiency choice.\u003c\/p\u003e\u003cp\u003eA millivolt valve (no house power needed) or IPI electronic ignition with battery backup both keep the fire going during a power failure. Wall thermostats and Proflame remotes, including thermostatic, modulating and light\/fan-control versions, are available.\u003c\/p\u003e\u003cp\u003eVenting is 5\"\/8\" direct vent (Kingsman Z-Flex 5\"\/8\" or a listed rigid system), horizontal or vertical, with PVH58 power vent compatibility for long runs.\u003c\/p\u003e\u003cp\u003eThe MCVST42 is the right pick for a fire shared between two rooms; for a three-sided view at the end of a wall, see the MCVP42 peninsula.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Clean View appliance\u003c\/strong\u003e: two-sided see-through design with no louvers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect vent\u003c\/strong\u003e: sealed combustion, 5\"\/8\" venting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo millivolt or IPI valve\u003c\/strong\u003e: operates during a power failure with Hi\/Lo heat and flame adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCeramic (Robax or coated Neoceram) glass\u003c\/strong\u003e: heater rated, higher efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 31,000 \/ 21,000 BTU\/h natural gas; 29,250 \/ 23,000 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 66.45% MV \/ 68.58% IPI (NG); 67.88% \/ 70.36% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlass tray (optional)\u003c\/strong\u003e: MST42GT for bronze glass media, cannonballs and the driftwood log set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLog sets (optional)\u003c\/strong\u003e: M42LOG4 oak 8-piece (with the M42LG log grate, natural gas only) or M42LOG3 driftwood 6-piece (with the glass tray).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccent lighting (optional)\u003c\/strong\u003e: ULK3 two-lamp light kit, used with the glass tray.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: MST42PL porcelain reflective or MST42RLT traditional brick.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit (optional)\u003c\/strong\u003e: Z46FK heat activated with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounds (optional)\u003c\/strong\u003e: ZCV42S1BL hearth-mount, ZCV42S1PFBL 4\" picture frame or ZCV42S2PFBL 1-5\/8\" picture frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTile lip kit (optional)\u003c\/strong\u003e: ZCVTLK.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat (optional)\u003c\/strong\u003e: Z2MT wall-mount millivolt or Z80PT programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional)\u003c\/strong\u003e: thermostat on\/off, thermostatic modulating, and modulating with fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall mount battery holder (optional)\u003c\/strong\u003e: WMBH for the IPI backup batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent compatible\u003c\/strong\u003e: PVH58 \/ PVH58FM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: kits 42MST-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKLP2 \/ -CKNGI \/ -CKNG2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eMCVST42NH \/ MCVST42LPH (millivolt); MCVST42NHE \/ MCVST42LPHE (IPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eMulti-sided (two-sided see-through) direct vent gas fireplace, top vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e43-1\/16\" W x 51-1\/4\" H x 24-1\/4\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer as labeled values. Framing goes to the standoffs (0\" back and top) with the enclosure ceiling at least 67\" above the bottom of the fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e33-11\/16\" W x 27-3\/16\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e24\" in front (both viewing sides); back and top standoffs 0\"; floor 0\"; ceiling at least 67\" above the bottom of the fireplace; 90° bend in the enclosure 2\"; vertical pipe 1\"; horizontal pipe 1-1\/2\" top, 1\" sides and bottom (manual p.28); combustible mantel may begin 12-5\/8\" above the top of the opening, adjacent wall at least 1-1\/2\" from the standoff (p.27)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e31,000 \/ 21,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e29,250 \/ 23,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e66.45% MV \/ 68.58% IPI (NG); 67.88% \/ 70.36% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic (Robax or coated Neoceram), with safety screen barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e5\"\/8\" direct vent, flex or rigid; PVH58 power vent compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHi\/Lo millivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFacing: face materials must be non-combustible; concrete board recommended 44\" x 53\"; a recessed combustible wall may sit no more than 3\" above the header (p.14).\u003c\/li\u003e\n\u003cli\u003eFloor: no hearth is required; with vinyl flooring use a 12\" hearth or raise the unit 24\"; carpet needs a metal or wood panel.\u003c\/li\u003e\n\u003cli\u003eAppliance weight: not listed in the manual text.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with burner, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eCeramic (Robax or coated Neoceram) glass on all viewing sides\u003c\/li\u003e\n\u003cli\u003eSafety screen barriers\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eA flame display: M42LG log grate with M42LOG4 oak logs (natural gas), or the MST42GT glass tray with 10 lb (2 bags) of Z5GC bronze glass media, RBCB1 cannonballs or M42LOG3 driftwood logs\u003c\/li\u003e\n\u003cli\u003e5\"\/8\" direct vent pipe and termination (Kingsman Z-Flex 5\"\/8\" or a listed rigid system with the Z58DFA adapter where required)\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle for IPI models and the fan kit\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for IPI battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e42MVB258 pilot shield for the glass tray and log grate\u003c\/li\u003e\n\u003cli\u003eULK3 light kit\u003c\/li\u003e\n\u003cli\u003eMST42PL porcelain reflective\u003c\/li\u003e\n\u003cli\u003eMST42RLT traditional brick\u003c\/li\u003e\n\u003cli\u003eZCV42S1BL hearth-mount\u003c\/li\u003e\n\u003cli\u003eZCV42S1PFBL 4\" picture frame\u003c\/li\u003e\n\u003cli\u003eZCV42S2PFBL 1-5\/8\" picture frame\u003c\/li\u003e\n\u003cli\u003eZ46FK fan kit\u003c\/li\u003e\n\u003cli\u003eZCVTLK tile lip kit\u003c\/li\u003e\n\u003cli\u003eZ2MT \/ Z80PT wall thermostats\u003c\/li\u003e\n\u003cli\u003eProflame remotes (GT \/ EGT series)\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder\u003c\/li\u003e\n\u003cli\u003ePVH58 \/ PVH58FM power vent\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/42MCVST-MAN19-8.pdf\"\u003eMCVST42 installation and operating manual (42MCVST-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2017\/03\/19717-KM-B085-MCVST42ENG-June2024-FNL1-Web-1.pdf\"\u003eMCVST42 brochure and specifications (June 2024)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (MCVST42 installation and operating manual (42MCVST-MAN19), information chapter). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.2–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for manufactured\/mobile homes where local codes allow (information chapter).\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation, framing and clearances (pp.10–28)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eClearances: 24\" in front (both viewing sides); 0\" at the back and top standoffs and floor; ceiling at least 67\".\u003c\/li\u003e\n\u003cli\u003eHorizontal vent framing: 58-1\/2\" (natural gas) \/ 70-1\/2\" (propane) from the bottom of the fireplace, plus 1\/4\" per foot of rise.\u003c\/li\u003e\n\u003cli\u003eFacing: face materials must be non-combustible; concrete board recommended 44\" x 53\"; a recessed combustible wall may sit no more than 3\" above the header (p.14).\u003c\/li\u003e\n\u003cli\u003eMantel: a combustible mantel may begin 12-5\/8\" above the top of the opening; adjacent wall at least 1-1\/2\" from the standoff (p.27).\u003c\/li\u003e\n\u003cli\u003eNo hearth is required; vinyl flooring needs a 12\" hearth or a 24\" raise.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMedia, liners and accessories (pp.29–60)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eGlass tray MST42GT (not used with the brick liner on the MCVP42) or the M42LG log grate, which includes two grates, lava rock, embers and wool.\u003c\/li\u003e\n\u003cli\u003eUse only the log set approved for the grate or tray you choose, and keep the pilot uncovered.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm Robax or coated Neoceram ceramic, sealed with silicone rated to 500°F; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas and maintenance (pp.29–60)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.52).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.52).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.52).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.52). Field conversion between natural gas and propane uses Kingsman kits 42MST-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKLP2 \/ -CKNGI \/ -CKNG2 (IPI), installed by a qualified agency (pp.57–59).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eProflame controls (pp.61–75)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.61–75).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eDo not wire 120 V to millivolt switches or thermostats; switch-wire length is limited by gauge (e.g. 18 AWG up to 40 ft).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.76–84)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVent: Kingsman Z-Flex 5\"\/8\" or approved 5\"\/8\" direct vent systems (e.g. MG-DuraVent, Selkirk Direct-Temp); a 9\" round hole is needed through masonry, 12\" x 12\" framing in combustible walls.\u003c\/li\u003e\n\u003cli\u003eMinimum vertical 58-1\/2\" (natural gas) \/ 70-1\/2\" (propane) from the bottom of the fireplace, plus 1\/4\" per foot of rise; maximum vertical 43 ft; maximum horizontal 20 ft (with 7 ft of vertical). Run limits follow the sibling MCVP42 manual's 5\"\/8\" table.\u003c\/li\u003e\n\u003cli\u003eUp to two 45° bends in the horizontal run (18\" each) plus two more 90° bends (36\" each); remove the restrictor for runs under 15 ft.\u003c\/li\u003e\n\u003cli\u003ePVH58 \/ PVH58FM power vent approved; downward runs are not allowed on millivolt models, and IPI models must not use the cold-climate switch with power venting.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.8).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.7).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (MCVST42 installation and operating manual (42MCVST-MAN19), p.89).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — MCVST42H\u003c\/h3\u003e\n\u003ch4\u003eWhat framing does the MCVST42H need?\u003c\/h4\u003e\u003cp\u003eIt is a zero-clearance fireplace: framing goes to the standoffs with 0\" at the back and top and 0\" to the floor, with 24\" clear in front of both viewing sides. The enclosure ceiling must be at least 67\" above the bottom of the fireplace. The unit measures 43-1\/16\" W × 51-1\/4\" H × 24-1\/4\" D.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents off the top with 5\"\/8\" direct vent pipe, flex or rigid. The vent needs a minimum vertical rise of 58-1\/2\" (natural gas) or 70-1\/2\" (propane) from the bottom of the fireplace, and runs go up to 43 ft vertical or 20 ft horizontal with 7 ft of vertical. It is also compatible with the PVH58 power vent.\u003c\/p\u003e\n\u003ch4\u003eCan the MCVST42H run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It comes as MCVST42NH \/ MCVST42LPH (millivolt) and MCVST42NHE \/ MCVST42LPHE (IPI), rated 31,000 \/ 21,000 BTU\/h (max\/min) on natural gas and 29,250 \/ 23,000 BTU\/h on propane. Field conversion kits are 42MST-CKLP (millivolt) or 42MST-CKLPI \/ 42MST-CKLP2 (IPI).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity at all. IPI models keep the fire running on four AA backup batteries; the fans and lights do not run on battery.\u003c\/p\u003e\n\u003ch4\u003eWhat's the warranty?\u003c\/h4\u003e\u003cp\u003eDefective components are covered for parts and labour for the first year after installation, except accent light bulbs, gasketing, glass fronts and paint. The heat exchanger, combustion chamber and burner carry a limited lifetime warranty for as long as the original owner owns the fireplace; after the first year the defective part is exchanged, and labour and freight are not covered.\u003c\/p\u003e\n\u003ch4\u003eHow high must a mantel be?\u003c\/h4\u003e\u003cp\u003eA combustible mantel may begin 12-5\/8\" above the top of the opening, and an adjacent wall must be at least 1-1\/2\" from the standoff.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912058245282,"sku":"MCVST42NH","price":8965.69,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912058278050,"sku":"MCVST42LPH","price":9067.12,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912058310818,"sku":"MCVST42NHE","price":9377.45,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI","offer_id":50912058343586,"sku":"MCVST42LPHE","price":9480.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/MCVST42-2_66cfe682-316f-4d4b-bc93-5f60a2533187.jpg?v=1795038483"},{"product_id":"kingsman-idv24-direct-vent-gas-fireplace-insert-idv24","title":"Kingsman IDV24 Direct Vent Gas Fireplace Insert IDV24","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman IDV24 is the smallest insert in Kingsman's IDV direct vent range, made for small or shallow wood-burning masonry fireplaces and listed zero-clearance factory-built wood fireplaces. It turns a fireplace you rarely use into a sealed gas fire with real heat and push-button convenience.\u003c\/p\u003e\u003cp\u003eA dual burner with glowing embers lights the LOGF24OAK Split Oak log set, or glass media with optional RBCB1 cannonballs, behind a 20-13\/16\" W x 11\" H ceramic glass view. The IDV24RLT brick liner sets a traditional look inside, and the black I24CV1BL Clean View front with an I24S3827, I24SPF3829 picture-frame or I24SU4541 universal surround finishes the opening.\u003c\/p\u003e\u003cp\u003eInput is 23,500 BTU\/h on natural gas or 24,000 BTU\/h on propane, and a standard heat-activated variable-speed blower moves the heat into the room. A millivolt valve needs no house power and IPI ignition has battery backup, so the fire keeps working in a power outage; E2 models include a Proflame 2 remote. It vents up the existing chimney through a 3\"\/3\" co-linear liner, or a 2\"\/3\" liner with the I23FAK-KIT adapter for a 6\" chimney, to an IDVVT36 cap.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect vent fireplace insert\u003c\/strong\u003e: sealed combustion for existing masonry or listed factory-built fireplaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual burner\u003c\/strong\u003e: with glowing embers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMillivolt or IPI valve\u003c\/strong\u003e: operates during power failures, with adjustable flame control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-radiating ceramic glass\u003c\/strong\u003e: Robax or coated Neoceram, 5 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-activated blower\u003c\/strong\u003e: with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn\/off rocker switch\u003c\/strong\u003e: for simple manual operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (E2 models)\u003c\/strong\u003e: flame, fan, thermostat and smart-thermostat control; battery backup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included with the Clean View front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 23,500 \/ 16,500 BTU\/h natural gas; 24,000 \/ 20,000 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 53.53% MV \/ 55.58% IPI (NG); 57.51% \/ 59.24% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: bedroom and mobile\/manufactured home (USA) approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame display\u003c\/strong\u003e: LOGF24OAK Fibre Split Oak log set, or glass embers and RBCB1 cannonballs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean View fronts\u003c\/strong\u003e: I24CV1BL Clean View front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounds\u003c\/strong\u003e: I24S3827, I24SPF3829 picture frame or I24SU4541 universal surround.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: IDV24RLT traditional brick liner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRisers (optional)\u003c\/strong\u003e: I34R40 riser to fit taller openings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMantel clearance shield (optional)\u003c\/strong\u003e: I33CS lowers the minimum combustible mantel height.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall thermostat (optional)\u003c\/strong\u003e: standard on\/off or programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional, millivolt \/ PF1)\u003c\/strong\u003e: on\/off, thermostatic, thermostatic modulating and fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCo-linear venting\u003c\/strong\u003e: 3\"\/3\" (IDVFK25) or 2\"\/3\" (I23FK25) co-linear; I23FAK flue adaptor for a 6\" chimney.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: kits 24IDV-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eIDV24N \/ IDV24LP (millivolt); IDV24NE \/ IDV24LPE (IPI PF1); IDV24NE2 \/ IDV24LPE2 (IPI Proflame 2 with remote)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eDirect vent gas fireplace insert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e24-1\/4\" W x 18-1\/2\" H x 14\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eMinimum fireplace opening 24-1\/4\" front width, 19-1\/4\" back width, 18-1\/2\" H, 14\" D (pp.1, 10). Fits a masonry fireplace or a listed zero-clearance factory-built solid-fuel fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e20-13\/16\" W x 11\" H (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eInstalls inside an existing fireplace; the floor under the insert must be non-combustible, and a 12\" non-combustible area is required above the fireplace (p.14); minimum combustible mantel height at 0\", 2\", 4\", 6\", 8\" and 10\" mantel depth: 31-1\/8\", 33-1\/8\", 35-1\/8\", 37-1\/8\", 39-1\/8\" and 41-1\/8\" (p.13); the insert sits flush with the finished surround, with at least 1\/2\" left around the Clean View front so it can be removed (p.14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e23,500 \/ 16,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e24,000 \/ 20,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e53.53% MV \/ 55.58% IPI (NG); 57.51% \/ 59.24% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic (Robax or coated Neoceram), 5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e3\"\/3\" (IDVFK25) or 2\"\/3\" (I23FK25) co-linear; I23FAK flue adaptor for a 6\" chimney; IDVVT36 vertical termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eMillivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBlower\u003c\/th\u003e\n\u003ctd\u003eHeat-activated, variable speed (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eVenting and floor\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe floor beneath the insert must be non-combustible; keep 1\/2\" around the Clean View so it can be removed for service.\u003c\/li\u003e\n\u003cli\u003eVenting: 3\"\/3\" liner 12 ft minimum and 40 ft maximum vertical, horizontal offset up to 2 ft (p.52); 2\"\/3\" liner 12 ft minimum and 25 ft maximum vertical (p.55).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eProduct video\u003c\/h3\u003e\u003cdiv class=\"uf-desc-video\" style=\"position:relative;width:100%;max-width:960px;aspect-ratio:16\/9;margin:0 0 16px\"\u003e\u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/5aAFJI-JEuE?rel=0\" title=\"Kingsman IDV24 gas fireplace insert video\" loading=\"lazy\" style=\"position:absolute;inset:0;width:100%;height:100%;border:0;border-radius:4px\" allow=\"accelerometer; encrypted-media; gyroscope; picture-in-picture; fullscreen\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsert with dual burner and heat-activated variable-speed blower, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eCeramic glass front (Robax or coated Neoceram, 5 mm)\u003c\/li\u003e\n\u003cli\u003eEmbers, insulation wool and lava rock (supplied with the fireplace)\u003c\/li\u003e\n\u003cli\u003eProflame 2 remote (IDV24NE2 \/ IDV24LPE2 only)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eA Clean View front: I24CV1BL Clean View front\u003c\/li\u003e\n\u003cli\u003eOne flame display: LOGF24OAK Split Oak log set, MQLOGF24DW Driftwood log set, or two 5 lb bags of MQG5 glass media (10 lb maximum: MQG5C bronze, MQG5B black, MQG5A Azuria, MQG5W white or MQG5ZG Zircon); RBCB1 cannonballs can be added\u003c\/li\u003e\n\u003cli\u003eIDVFK25 3\" flex pipe kit (two 3\" x 25 ft lengths) for a 3\"\/3\" co-linear liner, or the I23FK25 2\"\/3\" flex venting kit (25 ft) with the I23FAK-KIT 2\"\/3\" venting adapter for a 6\" chimney\u003c\/li\u003e\n\u003cli\u003eIDVVT36 3\"\/3\" co-linear vertical termination with seal plate (required with either liner)\u003c\/li\u003e\n\u003cli\u003eIDVLCP lower chase sealant plate, sealed with red RTV silicone\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle\u003c\/li\u003e\n\u003cli\u003eA clean, sound chimney not shared with any solid-fuel appliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eI24S3827 surround, black, 37-13\/16\" x 27\"\u003c\/li\u003e\n\u003cli\u003eI24SPF3829 picture-frame surround\u003c\/li\u003e\n\u003cli\u003eI24SU4541 universal surround, black\u003c\/li\u003e\n\u003cli\u003eIDV24RLT brick liner panels\u003c\/li\u003e\n\u003cli\u003eI34R40 2-1\/2\" riser, 40\"\u003c\/li\u003e\n\u003cli\u003eI33CS mantel clearance shield\u003c\/li\u003e\n\u003cli\u003eRBCB1 cannonballs\u003c\/li\u003e\n\u003cli\u003eZ2MT digital wall thermostat (millivolt \/ PF1)\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable digital wall thermostat (millivolt \/ PF1)\u003c\/li\u003e\n\u003cli\u003eGTRC thermostat remote (millivolt models)\u003c\/li\u003e\n\u003cli\u003eGTMRCN thermostat \/ modulating remote, natural gas (millivolt models)\u003c\/li\u003e\n\u003cli\u003eGTMRCP thermostat \/ modulating remote, propane (millivolt models)\u003c\/li\u003e\n\u003cli\u003eEGTRC thermostat remote (IPI Proflame 1 models)\u003c\/li\u003e\n\u003cli\u003eEGTMRCN thermostat \/ modulating remote, natural gas (IPI Proflame 1 models)\u003c\/li\u003e\n\u003cli\u003eEGTMRCP thermostat \/ modulating remote, propane (IPI Proflame 1 models)\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI models)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2022\/09\/24IDV-MAN19-6.pdf\"\u003eIDV24 installation and operating manual (24IDV-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/12\/21378-KM-B103-IDV24-34-44ENG-Dec2025-FNL1-Web.pdf\"\u003eIDV24\/IDV34\/IDV44 brochure and specifications (Dec 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (IDV24 installation and operating manual (24IDV-MAN19), safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.2–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for bedrooms and for manufactured\/mobile homes in the USA where local codes allow.\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFireplace requirements, dimensions and mantel (pp.10–23)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFits a masonry fireplace (leave the refractory in place) or a listed zero-clearance factory-built fireplace; minimum opening factory-built opening at least 24-1\/4\" W x 18-1\/2\" H x 14\" D, back width 19-1\/4\" (pp.1, 10).\u003c\/li\u003e\n\u003cli\u003eIn a factory-built fireplace, the damper, grates, glass doors, screen rails and smoke baffle may need to be removed per the manual.\u003c\/li\u003e\n\u003cli\u003eMantel: 0\" depth: 31-1\/8\" above the unit, rising 2\" for every 2\" of mantel depth up to 41-1\/8\" at 10\" (p.13).\u003c\/li\u003e\n\u003cli\u003eNon-combustible floor beneath the insert; non-combustible facing in the area above the combustible-mantel line.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFronts, surrounds, liners and media (pp.10–23, 24–29)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFronts: I24CV1BL Clean View front. Surrounds: I24S3827, I24SPF3829 picture frame or I24SU4541 universal surround.\u003c\/li\u003e\n\u003cli\u003eMedia: LOGF24OAK Fibre Split Oak log set, or glass embers and RBCB1 cannonballs; follow the placement diagram and keep the pilot clear.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm Robax or coated Neoceram; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.30–36)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.33).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.33).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.33).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.33). Field conversion between natural gas and propane uses Kingsman kits 24IDV-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI), installed by a qualified agency (pp.30–32).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and electrical (pp.37–51)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.37–51).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eGrounded three-prong plug required for the blower; do not wire 120 V to millivolt switches.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.52–58)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCo-linear liner: 3\"\/3\" (IDVFK25) or 2\"\/3\" (I23FK25) co-linear; I23FAK flue adaptor for a 6\" chimney, Kingsman flex or MG-DuraVent; termination IDVVT36.\u003c\/li\u003e\n\u003cli\u003eVertical rise 12 ft minimum, 40 ft maximum; up to 2 ft of horizontal offset.\u003c\/li\u003e\n\u003cli\u003eThe chimney must be cleaned and inspected (professionally if it served a wood fire), must not serve a solid-fuel appliance, and needs a rain cap with the gap between chimney and liner capped.\u003c\/li\u003e\n\u003cli\u003eSeal the lower chase with the IDVLCP block-off plate.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.8).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.7).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (IDV24 installation and operating manual (24IDV-MAN19), p.58).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — IDV24\u003c\/h3\u003e\n\u003ch4\u003eWhat size fireplace opening does the IDV24 need?\u003c\/h4\u003e\u003cp\u003eThe opening must be at least 24-1\/4\" wide at the front, 19-1\/4\" wide at the back, 18-1\/2\" high and 14\" deep. It fits a masonry wood fireplace or a listed zero-clearance factory-built wood fireplace, and the floor under the insert must be non-combustible.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents up the existing chimney to an IDVVT36 vertical termination. With the IDVFK25 kit (two 3\" x 25 ft flex lengths) the 3\"\/3\" liner runs 12 ft minimum to 40 ft maximum vertical, with up to 2 ft of horizontal offset. For a 6\" chimney, the I23FK25 2\"\/3\" kit with the I23FAK-KIT adapter runs 12 ft minimum to 25 ft maximum vertical. The lower chase is sealed with the IDVLCP plate, and the chimney must not serve any solid-fuel appliance.\u003c\/p\u003e\n\u003ch4\u003eCan the IDV24 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It comes in natural gas (IDV24N millivolt, IDV24NE IPI, IDV24NE2 IPI with Proflame 2) and propane (IDV24LP, IDV24LPE, IDV24LPE2) versions. Field conversion uses Kingsman kits 24IDV-CKLP \/ -CKNG (millivolt) or -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity to run the fire. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in an outage; the blower needs house power and does not run on battery.\u003c\/p\u003e\n\u003ch4\u003eIs a remote included?\u003c\/h4\u003e\u003cp\u003eOn the IDV24NE2 and IDV24LPE2 (Proflame 2) models, yes. The other models take an optional remote: GTRC, GTMRCN or GTMRCP on millivolt models, or EGTRC, EGTMRCN or EGTMRCP on IPI Proflame 1 models. Z2MT and Z80PT wall thermostats are also available.\u003c\/p\u003e\n\u003ch4\u003eHow high must a mantel be above the IDV24?\u003c\/h4\u003e\u003cp\u003eA combustible mantel needs a minimum height of 31-1\/8\" at 0\" depth, rising 2\" for every 2\" of depth: 33-1\/8\" at 2\", 35-1\/8\" at 4\", 37-1\/8\" at 6\", 39-1\/8\" at 8\" and 41-1\/8\" at 10\". A 12\" non-combustible area is required above the fireplace.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912070205602,"sku":"IDV24N","price":2621.48,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912070238370,"sku":"IDV24LP","price":2685.48,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912070271138,"sku":"IDV24NE","price":2994.6,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI","offer_id":50912070303906,"sku":"IDV24LPE","price":3058.6,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI Proflame 2 with Remote","offer_id":50912070336674,"sku":"IDV24NE2","price":3636.99,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI Proflame 2 with Remote","offer_id":50912070369442,"sku":"IDV24LPE2","price":3722.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/IDV24-Log24OAK-Oct2022-2.jpg?v=1795038538"},{"product_id":"kingsman-idv26-direct-vent-gas-fireplace-insert-idv26","title":"Kingsman IDV26 Direct Vent Gas Fireplace Insert IDV26","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman IDV26 is a direct vent gas fireplace insert that turns an existing wood-burning masonry fireplace, or a listed zero-clearance factory-built wood fireplace, into a sealed, efficient gas fire. It is the wide model of the IDV insert range and suits homeowners who want real heat and push-button convenience from a fireplace they rarely use.\u003c\/p\u003e\u003cp\u003eA dual burner with glowing embers lights the LOGF27 Fibre Split Oak log set or the RSP10 glass support platform with 15 lb of bronze glass. An IDV26RL refractory brick or IDV26PRL porcelain reflective liner sets the look inside, and a black I26CV1BL, I26CV2BL or I26CV3BL Clean View front, or an I26CVPF1BL or I26CVPF2BL picture-frame Clean View, finishes the opening. Input is 28,500 BTU\/h on natural gas and 28,000 BTU\/h on propane, at a fireplace efficiency of 65.25% MV \/ 67.37% IPI (NG).\u003c\/p\u003e\u003cp\u003eHeat-radiating ceramic glass and a standard heat-activated variable-speed blower push warmth into the room. A millivolt valve needs no house power and IPI ignition has battery backup, so the fire keeps working in a power outage; E2 models include a Proflame 2 remote. It vents up the existing chimney through a 3\"\/3\" co-linear liner to an IDVVT36 cap, 12 to 40 ft vertical.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect vent fireplace insert\u003c\/strong\u003e: sealed combustion for existing masonry or listed factory-built fireplaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual burner\u003c\/strong\u003e: with glowing embers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMillivolt or IPI valve\u003c\/strong\u003e: operates during power failures, with adjustable flame control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-radiating ceramic glass\u003c\/strong\u003e: Robax or coated Neoceram, 5 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-activated blower\u003c\/strong\u003e: with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn\/off rocker switch\u003c\/strong\u003e: for simple manual operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (E2 models)\u003c\/strong\u003e: flame, fan, thermostat and smart-thermostat control; battery backup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included with the Clean View front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 28,500 \/ 19,500 BTU\/h natural gas; 28,000 \/ 23,000 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 65.25% MV \/ 67.37% IPI (NG); 66.30% \/ 68.30% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: bedroom and mobile\/manufactured home (USA) approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame display\u003c\/strong\u003e: LOGF27 Fibre Split Oak log set, or RSP10 glass support platform with 15 lb of bronze glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean View fronts\u003c\/strong\u003e: I26CV1BL, I26CV2BL or I26CV3BL Clean View front, or I26CVPF1BL \/ I26CVPF2BL picture-frame Clean View.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounds\u003c\/strong\u003e: I26S1BL slim, I26SPF1BL slim picture frame or I26SUBL universal surround.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: IDV26PRL porcelain reflective or IDV26RL refractory brick liner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRisers (optional)\u003c\/strong\u003e: I33R40 \/ I33R44 risers to fit taller openings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMantel clearance shield (optional)\u003c\/strong\u003e: I33CS lowers the minimum combustible mantel height.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall thermostat (optional)\u003c\/strong\u003e: standard on\/off or programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional, millivolt \/ PF1)\u003c\/strong\u003e: on\/off, thermostatic, thermostatic modulating and fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCo-linear venting\u003c\/strong\u003e: 3\"\/3\" through the existing chimney with the IDVFK25 flex kit and IDVVT36 termination; 12 to 40 ft vertical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: kits 26IDV-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKLP2 \/ -CKNGI \/ -CKNG2 (IPI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eIDV26N \/ IDV26LP (millivolt); IDV26NE2 \/ IDV26LPE2 (IPI Proflame 2 with remote)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eDirect vent gas fireplace insert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e33\" W (components in) or 28\" W (components out) x 19-1\/2\" H x 14-1\/4\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eMinimum fireplace opening, components in: 33\" front width centred (31\" if not centred), 22\" back width, 19-1\/2\" H, 14-1\/4\" D; components out: 28\" front width, 22\" back width, 19-1\/2\" H, 14-1\/4\" D (p.12). Fits a masonry fireplace or a listed zero-clearance factory-built solid-fuel fireplace (p.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eInstalls inside an existing fireplace; the floor under the insert must be non-combustible, with a minimum hearth of 3\/4\" x 12-1\/2\" x 31\" W (p.34); wall coverings closer than the combustible-materials line must be non-combustible (p.34); combustible mantel 35-3\/8\" to 45-3\/8\" above the bottom of the unit as mantel depth increases (p.33), or 6-7\/8\" lower with the I33CS mantel clearance shield (p.35); leave 1\/2\" around the Clean View front so it can be removed for service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e28,500 \/ 19,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e28,000 \/ 23,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e65.25% MV \/ 67.37% IPI (NG); 66.30% \/ 68.30% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic (Robax or coated Neoceram), 5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e3\"\/3\" co-linear; IDVVT36 vertical termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eMillivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBlower\u003c\/th\u003e\n\u003ctd\u003eHeat-activated, variable speed (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eVenting and floor\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVenting: 12 ft minimum and 40 ft maximum vertical; horizontal offset up to 2 ft (p.68).\u003c\/li\u003e\n\u003cli\u003eThe floor beneath the insert must be non-combustible; keep 1\/2\" around the Clean View so it can be removed for service.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsert with dual burner and heat-activated variable-speed blower, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eCeramic glass front (Robax or coated Neoceram, 5 mm)\u003c\/li\u003e\n\u003cli\u003eProflame 2 remote (IDV26NE2 \/ IDV26LPE2 only)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne Clean View front: I26CV1BL, I26CV2BL or I26CV3BL Clean View, or I26CVPF1BL or I26CVPF2BL picture-frame Clean View (black)\u003c\/li\u003e\n\u003cli\u003eOne flame display: LOGF27 Fibre Split Oak log set, or RSP10 glass support platform with 15 lb of bronze glass\u003c\/li\u003e\n\u003cli\u003eIDVFK25 3\" flex pipe kit (two 25 ft lengths, for the 3\"\/3\" co-linear liner), or the MG DuraVent 46DVA-CL33 kit (termination cap and two 35 ft aluminium flex lengths)\u003c\/li\u003e\n\u003cli\u003eIDVVT36 3\"\/3\" co-linear vertical termination (with the IDVFK25 kit)\u003c\/li\u003e\n\u003cli\u003eIDVLCP lower chase sealant plate, sealed with red RTV silicone\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle\u003c\/li\u003e\n\u003cli\u003eA clean, sound chimney not shared with any solid-fuel appliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eI26S1BL slim surround, black\u003c\/li\u003e\n\u003cli\u003eI26SPF1BL slim picture-frame surround\u003c\/li\u003e\n\u003cli\u003eI26SUBL universal surround, black\u003c\/li\u003e\n\u003cli\u003eIDV26RL refractory brick liner\u003c\/li\u003e\n\u003cli\u003eIDV26PRL porcelain reflective panel liner\u003c\/li\u003e\n\u003cli\u003eI33R40 surround riser\u003c\/li\u003e\n\u003cli\u003eI33R44 surround riser\u003c\/li\u003e\n\u003cli\u003eI33CS mantel clearance shield\u003c\/li\u003e\n\u003cli\u003eZ2MT wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable wall thermostat\u003c\/li\u003e\n\u003cli\u003eGTRC remote (millivolt models)\u003c\/li\u003e\n\u003cli\u003eGTMRCN remote (millivolt models)\u003c\/li\u003e\n\u003cli\u003eGTMRCP remote (millivolt models)\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI models)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/26IDV-MAN19.pdf\"\u003eIDV26 installation and operating manual (26IDV-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/12\/21379-KM-B076-IDV26ENG-Nov2025-FNL1-Web.pdf\"\u003eIDV26 brochure and specifications (Nov 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (IDV26 installation and operating manual (26IDV-MAN19), safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.4–11)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for bedrooms and for manufactured\/mobile homes in the USA where local codes allow.\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFireplace requirements, dimensions and mantel (pp.12–27)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFits a masonry fireplace (leave the refractory in place) or a listed zero-clearance factory-built fireplace; minimum opening at least 33\" W x 19-1\/2\" H x 14-1\/4\" D with components in, or 28\" W with the CV2 components-out layout (pp.1, 12).\u003c\/li\u003e\n\u003cli\u003eIn a factory-built fireplace, the damper, grates, glass doors, screen rails and smoke baffle may need to be removed per the manual.\u003c\/li\u003e\n\u003cli\u003eMantel: with a Clean View front and no shield, 35-3\/8\" to 45-3\/8\" from the unit bottom depending on mantel depth (p.33); with the I33CS shield, 28-1\/2\" to 38-1\/2\" (p.35); hearth at least 3\/4\" x 12-1\/2\" x 31\" (p.34).\u003c\/li\u003e\n\u003cli\u003eNon-combustible floor beneath the insert; non-combustible facing in the area above the combustible-mantel line.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFronts, surrounds, liners and media (pp.12–27, 30–44)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFronts: I26CV1BL, I26CV2BL or I26CV3BL Clean View front, or I26CVPF1BL \/ I26CVPF2BL picture-frame Clean View. Surrounds: I26S1BL slim, I26SPF1BL slim picture frame or I26SUBL universal surround.\u003c\/li\u003e\n\u003cli\u003eMedia: LOGF27 Fibre Split Oak log set, or RSP10 glass support platform with 15 lb of bronze glass; follow the placement diagram and keep the pilot clear.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm Robax or coated Neoceram; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.45–51)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.48).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.48).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.48).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.48). Field conversion between natural gas and propane uses Kingsman kits 26IDV-CKLP \/ -CKNG (millivolt) and -CKLPI \/ -CKLP2 \/ -CKNGI \/ -CKNG2 (IPI), installed by a qualified agency (pp.50–51).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and electrical (pp.51–65)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.51–65).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eGrounded three-prong plug required for the blower; do not wire 120 V to millivolt switches.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.68–73)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCo-linear liner: 3\"\/3\", Kingsman IDVFK25 flex kit with the IDVVT36 termination, or MG DuraVent kit 46DVA-CL33 (p.68).\u003c\/li\u003e\n\u003cli\u003eVertical rise 12 ft minimum, 40 ft maximum; up to 2 ft of horizontal offset.\u003c\/li\u003e\n\u003cli\u003eThe chimney must be cleaned and inspected (professionally if it served a wood fire), must not serve a solid-fuel appliance, and needs a rain cap with the gap between chimney and liner capped.\u003c\/li\u003e\n\u003cli\u003eSeal the lower chase with the IDVLCP block-off plate.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.8).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.7).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (IDV26 installation and operating manual (26IDV-MAN19), p.73).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — IDV26\u003c\/h3\u003e\n\u003ch4\u003eWhat size fireplace opening does the IDV26 need?\u003c\/h4\u003e\u003cp\u003eWith the controls inside the insert the opening must be at least 33\" wide at the front (centred; 31\" if the insert is not centred), 22\" wide at the back, 19-1\/2\" high and 14-1\/4\" deep. With the components-out layout the front width drops to 28\". It fits a masonry wood fireplace or a listed zero-clearance factory-built wood fireplace; the floor under the insert must be non-combustible.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents up the existing chimney through a 3\"\/3\" co-linear liner: the Kingsman IDVFK25 kit (two 25 ft lengths of 3\" flex) with the IDVVT36 vertical termination, or the MG DuraVent 46DVA-CL33 kit. The vertical rise is 12 ft minimum and 40 ft maximum, with up to 2 ft of horizontal offset. The lower chase is sealed with the IDVLCP plate, and the chimney must not serve any solid-fuel appliance.\u003c\/p\u003e\n\u003ch4\u003eCan the IDV26 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It is offered here in natural gas (IDV26N millivolt, IDV26NE2 IPI with Proflame 2) and propane (IDV26LP millivolt, IDV26LPE2 IPI with Proflame 2), rated 28,500 \/ 19,500 BTU\/h on natural gas and 28,000 \/ 23,000 BTU\/h on propane (max\/min). Field conversion uses Kingsman kits 26IDV-CKLP \/ -CKNG (millivolt) or -CKLPI \/ -CKNGI \/ -CKLP2 \/ -CKNG2 (IPI).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity to run the fire. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in an outage; the blower needs house power and does not run on battery.\u003c\/p\u003e\n\u003ch4\u003eIs a remote included?\u003c\/h4\u003e\u003cp\u003eOn the IDV26NE2 and IDV26LPE2 (Proflame 2) models, yes. The millivolt IDV26N and IDV26LP take an optional GTRC, GTMRCN or GTMRCP remote, or a Z2MT or Z80PT wall thermostat.\u003c\/p\u003e\n\u003ch4\u003eHow high must a mantel be above the IDV26?\u003c\/h4\u003e\u003cp\u003eA combustible mantel must sit 35-3\/8\" to 45-3\/8\" above the bottom of the unit, higher as the mantel gets deeper. The optional I33CS mantel clearance shield lowers those heights by 6-7\/8\". A hearth of at least 3\/4\" x 12-1\/2\" x 31\" wide is required.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912070434978,"sku":"IDV26N","price":3367.72,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912070467746,"sku":"IDV26LP","price":3455.87,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI Proflame 2 with Remote","offer_id":50912070500514,"sku":"IDV26NE2","price":4421.87,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI Proflame 2 with Remote","offer_id":50912070533282,"sku":"IDV26LPE2","price":4507.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/IDV26-1.jpg?v=1795038539"},{"product_id":"kingsman-idv34-direct-vent-gas-fireplace-insert-idv34","title":"Kingsman IDV34 Direct Vent Gas Fireplace Insert IDV34","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman IDV34 is the mid-size insert in Kingsman's IDV direct vent range, made for typical masonry and listed zero-clearance factory-built wood fireplaces. It turns a fireplace you rarely use into a sealed gas fire with real heat and push-button convenience.\u003c\/p\u003e\u003cp\u003eA dual burner with glowing embers lights the LOGF35 Fibre Split Oak log set or the RSP10 glass support platform behind a 25-5\/8\" W x 14-1\/8\" H ceramic glass view. An IDV33RL refractory brick or IDV33PRL porcelain reflective liner sets the look inside, and the black I34CV1BL Clean View front, or the I34CV6BL Clean View with backer for shallower openings, finishes the face with an I34S3927BL, I34SPF4131BL picture-frame or I34SU4541BL universal surround.\u003c\/p\u003e\u003cp\u003eInput is 30,500 BTU\/h on natural gas and 28,500 BTU\/h on propane, and a standard heat-activated variable-speed blower moves the heat into the room. A millivolt valve needs no house power and IPI ignition has battery backup, so the fire keeps working in a power outage; E2 models include a Proflame 2 remote. It vents up the existing chimney through a 3\"\/3\" co-linear liner to an IDVVT36 cap, 12 to 40 ft vertical.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect vent fireplace insert\u003c\/strong\u003e: sealed combustion for existing masonry or listed factory-built fireplaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual burner\u003c\/strong\u003e: with glowing embers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMillivolt or IPI valve\u003c\/strong\u003e: operates during power failures, with adjustable flame control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-radiating ceramic glass\u003c\/strong\u003e: Robax or coated Neoceram, 5 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-activated blower\u003c\/strong\u003e: with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn\/off rocker switch\u003c\/strong\u003e: for simple manual operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (E2 models)\u003c\/strong\u003e: flame, fan, thermostat and smart-thermostat control; battery backup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included with the Clean View front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 30,500 \/ 21,250 BTU\/h natural gas; 28,500 \/ 23,100 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 62.86% MV \/ 64.73% IPI (NG); 63.63% \/ 65.63% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: bedroom and mobile\/manufactured home (USA) approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame display\u003c\/strong\u003e: LOGF35 Fibre Split Oak log set, or RSP10 platform with bronze ember glass and cannonballs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean View fronts\u003c\/strong\u003e: I34CV1BL Clean View front or I34CV6BL Clean View with backer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounds\u003c\/strong\u003e: I34S3927BL, I34SPF4131BL picture frame or I34SU4541BL universal surround.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: IDV33PRL porcelain reflective or IDV33RL refractory brick liner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRisers (optional)\u003c\/strong\u003e: I34R40 \/ I44R45 risers to fit taller openings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMantel clearance shield (optional)\u003c\/strong\u003e: I33CS lowers the minimum combustible mantel height.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall thermostat (optional)\u003c\/strong\u003e: standard on\/off or programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional, millivolt \/ PF1)\u003c\/strong\u003e: on\/off, thermostatic, thermostatic modulating and fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCo-linear venting\u003c\/strong\u003e: 3\"\/3\" co-linear (IDVFK25 kit or DuraVent 46DVA-CL33).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: kits 33IDV-CKNG \/ -CKLP \/ -CKNGI \/ -CKNG2 \/ -CKLPI \/ -CKLP2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eIDV34N \/ IDV34LP (millivolt); IDV34NE \/ IDV34LPE (IPI PF1); IDV34NE2 \/ IDV34LPE2 (IPI Proflame 2 with remote)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eDirect vent gas fireplace insert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e28-5\/8\" W x 21-1\/2\" H x 17-3\/4\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eMinimum fireplace opening with the I34CV1BL front: 28-5\/8\" front width, 21-1\/4\" back width, 21-1\/2\" H, 17-3\/4\" D; with the I34CV6BL front: 26-7\/8\" front width, 21-1\/4\" back width, 21-1\/2\" H, 15-3\/4\" D (pp.11–12). Fits a masonry fireplace or a listed zero-clearance factory-built solid-fuel fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e25-5\/8\" W x 14-1\/8\" H (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eInstalls inside an existing fireplace; the floor under the insert must be non-combustible, and a combustible hearth is allowed (p.21); minimum combustible mantel height with the I34CV1BL or I34CV6BL front at 0\", 2\", 4\", 6\" and 8\" mantel depth: 36\", 38-1\/2\", 40-1\/2\", 42-1\/2\" and 44-1\/2\", or 30\", 32\", 34\", 36\" and 38\" with the I33CS mantel clearance shield (p.15); areas marked non-combustible must use non-combustible materials only; leave 1\/2\" around the Clean View front so it can be removed for service (p.21)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e30,500 \/ 21,250 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e28,500 \/ 23,100 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e62.86% MV \/ 64.73% IPI (NG); 63.63% \/ 65.63% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic (Robax or coated Neoceram), 5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e3\"\/3\" co-linear (IDVFK25 kit or DuraVent 46DVA-CL33); IDVVT36 vertical termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eMillivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBlower\u003c\/th\u003e\n\u003ctd\u003eHeat-activated, variable speed (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eVenting and floor\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe floor beneath the insert must be non-combustible; keep 1\/2\" around the Clean View so it can be removed for service.\u003c\/li\u003e\n\u003cli\u003eVenting: 12 ft minimum and 40 ft maximum vertical; horizontal offset up to 2 ft.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsert with dual burner and heat-activated variable-speed blower, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eCeramic glass front (Robax or coated Neoceram, 5 mm)\u003c\/li\u003e\n\u003cli\u003eProflame 2 remote (IDV34NE2 \/ IDV34LPE2 only)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eA Clean View front: I34CV1BL Clean View front or I34CV6BL Clean View with backer\u003c\/li\u003e\n\u003cli\u003eA flame display: LOGF35 Fibre Split Oak log set, or RSP10 platform with bronze ember glass and cannonballs\u003c\/li\u003e\n\u003cli\u003eIDVFK25 3\" flex pipe kit (two 3\" x 25 ft lengths, for the 3\"\/3\" co-linear liner), or the DuraVent 46DVA-CL33 kit (termination cap and two 35 ft aluminium flex lengths)\u003c\/li\u003e\n\u003cli\u003eIDVVT36 3\"\/3\" co-linear vertical termination (with the IDVFK25 kit)\u003c\/li\u003e\n\u003cli\u003eIDVLCP lower chase sealant plate, sealed with red RTV silicone\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle\u003c\/li\u003e\n\u003cli\u003eA clean, sound chimney not shared with any solid-fuel appliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eI34S3927BL surround, black, 39\" W\u003c\/li\u003e\n\u003cli\u003eI34SPF4131BL picture-frame surround, 41-1\/8\" W\u003c\/li\u003e\n\u003cli\u003eI34SU4541BL universal surround, 45\" W\u003c\/li\u003e\n\u003cli\u003eIDV33RL refractory brick liner\u003c\/li\u003e\n\u003cli\u003eIDV33PRL porcelain reflective panel liner\u003c\/li\u003e\n\u003cli\u003eI34R40 riser\u003c\/li\u003e\n\u003cli\u003eI44R45 riser\u003c\/li\u003e\n\u003cli\u003eI33CS mantel clearance shield\u003c\/li\u003e\n\u003cli\u003eZ1MT millivolt wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable digital wall thermostat\u003c\/li\u003e\n\u003cli\u003eGFRC on\/off remote\u003c\/li\u003e\n\u003cli\u003eGTRC thermostat remote (millivolt models)\u003c\/li\u003e\n\u003cli\u003eGTMRCN thermostat \/ modulating remote, natural gas (millivolt models)\u003c\/li\u003e\n\u003cli\u003eGTMRCP thermostat \/ modulating remote, propane (millivolt models)\u003c\/li\u003e\n\u003cli\u003eEGTRC thermostat remote (IPI Proflame 1 models)\u003c\/li\u003e\n\u003cli\u003eEGTMRCN thermostat \/ modulating remote, natural gas (IPI Proflame 1 models)\u003c\/li\u003e\n\u003cli\u003eEGTMRCP thermostat \/ modulating remote, propane (IPI Proflame 1 models)\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI models)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/34IDV-MAN19-4.pdf\"\u003eIDV34\/IDV44 installation and operating manual (34IDV-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/12\/21378-KM-B103-IDV24-34-44ENG-Dec2025-FNL1-Web.pdf\"\u003eIDV24\/IDV34\/IDV44 brochure and specifications (Dec 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (IDV34\/IDV44 installation and operating manual (34IDV-MAN19), safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.5–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for bedrooms and for manufactured\/mobile homes in the USA where local codes allow.\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFireplace requirements, dimensions and mantel (pp.11–27)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFits a masonry fireplace (leave the refractory in place) or a listed zero-clearance factory-built fireplace; minimum opening at least 28-5\/8\" W x 21-1\/2\" H x 17-3\/4\" D (pp.11–15).\u003c\/li\u003e\n\u003cli\u003eIn a factory-built fireplace, the damper, grates, glass doors, screen rails and smoke baffle may need to be removed per the manual.\u003c\/li\u003e\n\u003cli\u003eMantel: combustible mantel at 0\" depth: 36\" with the I34CV1BL or I34CV6BL front (30\" with the I33CS shield), rising with mantel depth (pp.11–15).\u003c\/li\u003e\n\u003cli\u003eNon-combustible floor beneath the insert; non-combustible facing in the area above the combustible-mantel line.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFronts, surrounds, liners and media (pp.11–27, 28–43)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFronts: I34CV1BL Clean View front or I34CV6BL Clean View with backer. Surrounds: I34S3927BL, I34SPF4131BL picture frame or I34SU4541BL universal surround.\u003c\/li\u003e\n\u003cli\u003eMedia: LOGF35 Fibre Split Oak log set, or RSP10 platform with bronze ember glass and cannonballs; follow the placement diagram and keep the pilot clear.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm Robax or coated Neoceram; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.44–55)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.51).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.51).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.51).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.51). Field conversion between natural gas and propane uses Kingsman kits 33IDV-CKNG \/ -CKLP \/ -CKNGI \/ -CKNG2 \/ -CKLPI \/ -CKLP2, installed by a qualified agency (pp.47–50).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and electrical (pp.56–68)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.56–68).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eGrounded three-prong plug required for the blower; do not wire 120 V to millivolt switches.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.69–71)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCo-linear liner: 3\"\/3\" co-linear (IDVFK25 kit or DuraVent 46DVA-CL33), Kingsman flex or MG-DuraVent; termination IDVVT36.\u003c\/li\u003e\n\u003cli\u003eVertical rise 12 ft minimum, 40 ft maximum; up to 2 ft of horizontal offset.\u003c\/li\u003e\n\u003cli\u003eThe chimney must be cleaned and inspected (professionally if it served a wood fire), must not serve a solid-fuel appliance, and needs a rain cap with the gap between chimney and liner capped.\u003c\/li\u003e\n\u003cli\u003eSeal the lower chase with the IDVLCP block-off plate.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.8).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.7).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (IDV34\/IDV44 installation and operating manual (34IDV-MAN19), p.76).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — IDV34\u003c\/h3\u003e\n\u003ch4\u003eWhat size fireplace opening does the IDV34 need?\u003c\/h4\u003e\u003cp\u003eWith the I34CV1BL front the opening must be at least 28-5\/8\" wide at the front, 21-1\/4\" wide at the back, 21-1\/2\" high and 17-3\/4\" deep. With the I34CV6BL Clean View with backer the front width can be 26-7\/8\" and the depth 15-3\/4\". It fits a masonry wood fireplace or a listed zero-clearance factory-built wood fireplace, and the floor under the insert must be non-combustible.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eIt vents up the existing chimney through a 3\"\/3\" co-linear liner: the Kingsman IDVFK25 kit (two 3\" x 25 ft flex lengths) with the IDVVT36 vertical termination, or the DuraVent 46DVA-CL33 kit. The vertical rise is 12 ft minimum and 40 ft maximum, with up to 2 ft of horizontal run. The lower chase is sealed with the IDVLCP plate, and the chimney must not serve any solid-fuel appliance.\u003c\/p\u003e\n\u003ch4\u003eCan the IDV34 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It comes in natural gas (IDV34N millivolt, IDV34NE IPI, IDV34NE2 IPI with Proflame 2) and propane (IDV34LP, IDV34LPE, IDV34LPE2) versions. Field conversion uses Kingsman kits 33IDV-CKNG \/ -CKLP (millivolt), 33IDV-CKNGI \/ -CKLPI (IPI Proflame 1) or 33IDV-CKNG2 \/ -CKLP2 (IPI Proflame 2).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity to run the fire. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in an outage; the blower needs house power and does not run on battery.\u003c\/p\u003e\n\u003ch4\u003eIs a remote included?\u003c\/h4\u003e\u003cp\u003eOn the IDV34NE2 and IDV34LPE2 (Proflame 2) models, yes. The other models take an optional remote: GFRC, GTRC, GTMRCN or GTMRCP on millivolt models, or EGTRC, EGTMRCN or EGTMRCP on IPI Proflame 1 models. Z1MT and Z80PT wall thermostats are also available.\u003c\/p\u003e\n\u003ch4\u003eHow high must a mantel be above the IDV34?\u003c\/h4\u003e\u003cp\u003eWith the I34CV1BL or I34CV6BL front, a combustible mantel needs a minimum height of 36\" at 0\" depth, rising to 38-1\/2\", 40-1\/2\", 42-1\/2\" and 44-1\/2\" for mantels 2\", 4\", 6\" and 8\" deep. The optional I33CS mantel clearance shield lowers those to 30\", 32\", 34\", 36\" and 38\".\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912103334050,"sku":"IDV34N","price":2920.94,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912103366818,"sku":"IDV34LP","price":2994.6,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912103399586,"sku":"IDV34NE","price":3337.53,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI","offer_id":50912103432354,"sku":"IDV34LPE","price":3411.19,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI Proflame 2 with Remote","offer_id":50912103465122,"sku":"IDV34NE2","price":3972.68,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI Proflame 2 with Remote","offer_id":50912103497890,"sku":"IDV34LPE2","price":4048.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/IDV34LP-with-LOGF35.jpg?v=1795038597"},{"product_id":"kingsman-idv44-direct-vent-gas-fireplace-insert-idv44","title":"Kingsman IDV44 Direct Vent Gas Fireplace Insert IDV44","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Kingsman IDV44 is the largest insert in Kingsman's IDV direct vent range. It turns a big wood-burning masonry fireplace, or a listed zero-clearance factory-built wood fireplace, into a sealed gas fire with the highest output of the range, for homeowners who want real heat and push-button convenience from a fireplace they rarely use.\u003c\/p\u003e\u003cp\u003eA dual burner with glowing embers lights the LOGF36 Fibre Split Oak log set or the RSP10 glass support platform behind a 29-7\/8\" W x 18-3\/8\" H ceramic glass view. IDV36RLT traditional brick, IDV36RLH herringbone brick or IDV36PRL porcelain reflective liners set the look inside, and the black I44CV1BL Clean View front with an I44S4432BL, I44SPF4436BL picture-frame or I44SU4742BL universal surround finishes the opening.\u003c\/p\u003e\u003cp\u003eInput is 34,250 BTU\/h on natural gas and 30,030 BTU\/h on propane, and a standard heat-activated variable-speed blower moves the heat into the room. A millivolt valve needs no house power and IPI ignition has battery backup, so the fire keeps working in a power outage; E2 models include a Proflame 2 remote. It vents up the existing chimney through a 4\"\/3\" co-linear liner to an IDVVT43 cap.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect vent fireplace insert\u003c\/strong\u003e: sealed combustion for existing masonry or listed factory-built fireplaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual burner\u003c\/strong\u003e: with glowing embers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMillivolt or IPI valve\u003c\/strong\u003e: operates during power failures, with adjustable flame control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-radiating ceramic glass\u003c\/strong\u003e: Robax or coated Neoceram, 5 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-activated blower\u003c\/strong\u003e: with variable speed control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn\/off rocker switch\u003c\/strong\u003e: for simple manual operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame 2 remote (E2 models)\u003c\/strong\u003e: flame, fan, thermostat and smart-thermostat control; battery backup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety screen barrier\u003c\/strong\u003e: included with the Clean View front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 34,250 \/ 24,860 BTU\/h natural gas; 30,030 \/ 22,840 BTU\/h propane (max\/min).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: FE 60.18% MV \/ 61.70% IPI (NG); 60.18% \/ 61.85% (LP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: bedroom and mobile\/manufactured home (USA) approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame display\u003c\/strong\u003e: LOGF36 Fibre Split Oak log set, or RSP10 platform with bronze ember glass and cannonballs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean View fronts\u003c\/strong\u003e: I44CV1BL Clean View front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounds\u003c\/strong\u003e: I44S4432BL, I44SPF4436BL picture frame or I44SU4742BL universal surround.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiners (optional)\u003c\/strong\u003e: IDV36PRL porcelain reflective, IDV36RLT traditional brick or IDV36RLH herringbone brick liner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRisers (optional)\u003c\/strong\u003e: I33R40 (40\") or I33R45 (45\") 2-1\/2\" riser to fit taller openings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMantel clearance shield (optional)\u003c\/strong\u003e: I33CS lowers the minimum combustible mantel height.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall thermostat (optional)\u003c\/strong\u003e: standard on\/off or programmable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control (optional, millivolt \/ PF1)\u003c\/strong\u003e: on\/off, thermostatic, thermostatic modulating and fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCo-linear venting\u003c\/strong\u003e: 4\"\/3\" co-linear (I43FK25 kit or DuraVent 46DVA-CL34).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField conversion\u003c\/strong\u003e: kits 36IDV-CKNG \/ -CKLP \/ -CKNGI \/ -CKLPI and 43IDV-CKNG2 \/ -CKLP2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: CSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eIDV44N \/ IDV44LP (millivolt); IDV44NE \/ IDV44LPE (IPI PF1); IDV44NE2 \/ IDV44LPE2 (IPI Proflame 2 with remote)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eDirect vent gas fireplace insert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e32-7\/8\" W x 25-3\/4\" H x 18\" D (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eMinimum fireplace opening 32-7\/8\" front width x 25-3\/4\" H x 18\" D, for the I44CV1BL, MQ44CV2BL and MQ44CV3BL fronts (pp.16–17). Fits a masonry fireplace or a listed zero-clearance factory-built solid-fuel fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e29-7\/8\" W x 18-3\/8\" H (Kingsman specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eInstalls inside an existing fireplace; the floor under the insert must be non-combustible, and a combustible hearth is allowed (p.21); minimum combustible mantel height with the I44CV1BL front at 0\", 2\", 4\", 6\" and 8\" mantel depth: 40\", 42\", 44\", 45\" and 46\", or 34\", 36\", 38\", 40\" and 42\" with the I33CS mantel clearance shield (p.20); areas marked non-combustible must use non-combustible materials only; leave 1\/2\" around the Clean View front so it can be removed for service (p.21)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e34,250 \/ 24,860 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (max \/ min)\u003c\/th\u003e\n\u003ctd\u003e30,030 \/ 22,840 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace efficiency (FE)\u003c\/th\u003e\n\u003ctd\u003e60.18% MV \/ 61.70% IPI (NG); 60.18% \/ 61.85% (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic (Robax or coated Neoceram), 5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003e4\"\/3\" co-linear (I43FK25 kit or DuraVent 46DVA-CL34); IDVVT43 vertical termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eMillivolt or IPI with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBlower\u003c\/th\u003e\n\u003ctd\u003eHeat-activated, variable speed (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e3\/8\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eVenting and floor\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe floor beneath the insert must be non-combustible; keep 1\/2\" around the Clean View so it can be removed for service.\u003c\/li\u003e\n\u003cli\u003eVenting: 12 ft minimum and 40 ft maximum vertical; horizontal offset up to 2 ft.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsert with dual burner and heat-activated variable-speed blower, set up for the selected fuel and ignition\u003c\/li\u003e\n\u003cli\u003eCeramic glass front (Robax or coated Neoceram, 5 mm)\u003c\/li\u003e\n\u003cli\u003eProflame 2 remote (IDV44NE2 \/ IDV44LPE2 only)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eA Clean View front: I44CV1BL Clean View front\u003c\/li\u003e\n\u003cli\u003eA flame display: LOGF36 Fibre Split Oak log set, or RSP10 platform with bronze ember glass and cannonballs\u003c\/li\u003e\n\u003cli\u003eI43FK25 co-linear flex kit (one 4\" x 25 ft exhaust and one 3\" x 25 ft intake), or the DuraVent 46DVA-CL34 kit (termination cap and two 35 ft aluminium flex lengths)\u003c\/li\u003e\n\u003cli\u003eIDVVT43 4\"\/3\" co-linear vertical termination (with the I43FK25 kit)\u003c\/li\u003e\n\u003cli\u003eI43LCP lower chase sealant plate, sealed with red RTV silicone\u003c\/li\u003e\n\u003cli\u003eGas supply with manual shutoff (3\/8\" NPT)\u003c\/li\u003e\n\u003cli\u003e120 VAC grounded receptacle\u003c\/li\u003e\n\u003cli\u003eA clean, sound chimney not shared with any solid-fuel appliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eI44S4432BL surround, black, 44\" W\u003c\/li\u003e\n\u003cli\u003eI44SPF4436BL picture-frame surround, 44\" W\u003c\/li\u003e\n\u003cli\u003eI44SU4742BL universal surround, 47\" W\u003c\/li\u003e\n\u003cli\u003eIDV36RLT traditional brick liner\u003c\/li\u003e\n\u003cli\u003eIDV36RLH herringbone brick liner\u003c\/li\u003e\n\u003cli\u003eIDV36PRL porcelain reflective panel liner (3 pieces)\u003c\/li\u003e\n\u003cli\u003eI33R40 2-1\/2\" riser, 40\"\u003c\/li\u003e\n\u003cli\u003eI33R45 2-1\/2\" riser, 45\"\u003c\/li\u003e\n\u003cli\u003eI33CS mantel clearance shield\u003c\/li\u003e\n\u003cli\u003eZ1MT millivolt wall thermostat\u003c\/li\u003e\n\u003cli\u003eZ80PT programmable digital wall thermostat\u003c\/li\u003e\n\u003cli\u003eGFRC on\/off remote\u003c\/li\u003e\n\u003cli\u003eGTRC thermostat remote (millivolt models)\u003c\/li\u003e\n\u003cli\u003eGTMRCN thermostat \/ modulating remote, natural gas (millivolt models)\u003c\/li\u003e\n\u003cli\u003eGTMRCP thermostat \/ modulating remote, propane (millivolt models)\u003c\/li\u003e\n\u003cli\u003eEGTRC thermostat remote (IPI Proflame 1 models)\u003c\/li\u003e\n\u003cli\u003eEGTMRCN thermostat \/ modulating remote, natural gas (IPI Proflame 1 models)\u003c\/li\u003e\n\u003cli\u003eEGTMRCP thermostat \/ modulating remote, propane (IPI Proflame 1 models)\u003c\/li\u003e\n\u003cli\u003eWMBH wall mount battery holder (IPI models)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/34IDV-MAN19-4.pdf\"\u003eIDV34\/IDV44 installation and operating manual (34IDV-MAN19), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/12\/21378-KM-B103-IDV24-34-44ENG-Dec2025-FNL1-Web.pdf\"\u003eIDV24\/IDV34\/IDV44 brochure and specifications (Dec 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2025\/02\/20450-KM-ProductGuide-KINGSMAN-2025-Feb2025-FNL-Web.pdf\"\u003eKingsman 2025 product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (IDV34\/IDV44 installation and operating manual (34IDV-MAN19), safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information (pp.5–9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCertified to CSA\/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).\u003c\/li\u003e\n\u003cli\u003eApproved for bedrooms and for manufactured\/mobile homes in the USA where local codes allow.\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFireplace requirements, dimensions and mantel (pp.16–27)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFits a masonry fireplace (leave the refractory in place) or a listed zero-clearance factory-built fireplace; minimum opening at least 32-7\/8\" W x 25-3\/4\" H x 18\" D (pp.16–20).\u003c\/li\u003e\n\u003cli\u003eIn a factory-built fireplace, the damper, grates, glass doors, screen rails and smoke baffle may need to be removed per the manual.\u003c\/li\u003e\n\u003cli\u003eMantel: combustible mantel at 0\" depth: 40\" with the I44CV1BL front (34\" with the I33CS shield), rising with mantel depth (pp.16–20).\u003c\/li\u003e\n\u003cli\u003eNon-combustible floor beneath the insert; non-combustible facing in the area above the combustible-mantel line.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFronts, surrounds, liners and media (pp.16–27, 28–43)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFronts: I44CV1BL Clean View front. Surrounds: I44S4432BL, I44SPF4436BL picture frame or I44SU4742BL universal surround.\u003c\/li\u003e\n\u003cli\u003eMedia: LOGF36 Fibre Split Oak log set, or RSP10 platform with bronze ember glass and cannonballs; follow the placement diagram and keep the pilot clear.\u003c\/li\u003e\n\u003cli\u003eReplacement glass must be 5 mm Robax or coated Neoceram; substitute glass voids the warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (pp.44–55)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas supply 5.5\" min \/ 7\" normal \/ 9\" max w.c.; manifold 3.5\" high \/ 1.6\" low w.c. (p.51).\u003c\/li\u003e\n\u003cli\u003ePropane supply 11\" min \/ 11\" normal \/ 12\" max w.c.; manifold 10\" high \/ 6.3\" low w.c. (p.51).\u003c\/li\u003e\n\u003cli\u003e3\/8\" NPT inlet; minimum 3\/8\" iron pipe for natural gas with at least 4.5\" w.c. at the meter; 1\/2\" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1\/2 psig (p.51).\u003c\/li\u003e\n\u003cli\u003eOrifices are sized for 0–4,500 ft elevation (p.51). Field conversion between natural gas and propane uses Kingsman kits 36IDV-CKNG \/ -CKLP \/ -CKNGI \/ -CKLPI and 43IDV-CKNG2 \/ -CKLP2, installed by a qualified agency (pp.47–50).\u003c\/li\u003e\n\u003cli\u003eHave the burner, pilot and venting inspected every year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls and electrical (pp.56–68)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMillivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.56–68).\u003c\/li\u003e\n\u003cli\u003eIPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.\u003c\/li\u003e\n\u003cli\u003eProflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).\u003c\/li\u003e\n\u003cli\u003eGrounded three-prong plug required for the blower; do not wire 120 V to millivolt switches.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (pp.69–71)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCo-linear liner: 4\"\/3\" co-linear (I43FK25 kit or DuraVent 46DVA-CL34), Kingsman flex or MG-DuraVent; termination IDVVT43.\u003c\/li\u003e\n\u003cli\u003eVertical rise 12 ft minimum, 40 ft maximum; up to 2 ft of horizontal offset.\u003c\/li\u003e\n\u003cli\u003eThe chimney must be cleaned and inspected (professionally if it served a wood fire), must not serve a solid-fuel appliance, and needs a rain cap with the gap between chimney and liner capped.\u003c\/li\u003e\n\u003cli\u003eSeal the lower chase with the I43LCP block-off plate.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).\u003c\/li\u003e\n\u003cli\u003eAfter turning it off, wait at least 60 seconds before relighting (p.5).\u003c\/li\u003e\n\u003cli\u003eThe glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).\u003c\/li\u003e\n\u003cli\u003eNever burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).\u003c\/li\u003e\n\u003cli\u003eInstall carbon-monoxide detectors on every level and near bedrooms (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eElectrical work: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (p.6).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e and \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-501a-standard-development\/501a\"\u003eANSI\/NFPA 501A\u003c\/a\u003e; in Canada CAN\/CSA Z240 MH (p.8).\u003c\/li\u003e\n\u003cli\u003eCarbon-monoxide detectors (Massachusetts and recommended practice): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034 (p.7).\u003c\/li\u003e\n\u003cli\u003eMassachusetts installations follow \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003ethe Massachusetts fuel gas code (248 CMR)\u003c\/a\u003e and 527 CMR (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (IDV34\/IDV44 installation and operating manual (34IDV-MAN19), p.76).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.\u003c\/li\u003e\n\u003cli\u003eNot covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.\u003c\/li\u003e\n\u003cli\u003eProof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — IDV44\u003c\/h3\u003e\n\u003ch4\u003eWhat size fireplace opening does the IDV44 need?\u003c\/h4\u003e\u003cp\u003eThe opening must be at least 32-7\/8\" wide at the front, 25-3\/4\" high and 18\" deep. It fits a masonry wood fireplace or a listed zero-clearance factory-built wood fireplace, and the floor under the insert must be non-combustible.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use?\u003c\/h4\u003e\u003cp\u003eIt vents up the existing chimney through a 4\"\/3\" co-linear liner: the Kingsman I43FK25 kit (one 4\" x 25 ft exhaust and one 3\" x 25 ft intake flex) with the IDVVT43 vertical termination, or the DuraVent 46DVA-CL34 kit. The lower chase is sealed with the I43LCP plate, and the chimney must be clean and must not serve any solid-fuel appliance.\u003c\/p\u003e\n\u003ch4\u003eCan the IDV44 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It comes in natural gas (IDV44N millivolt, IDV44NE IPI, IDV44NE2 IPI with Proflame 2) and propane (IDV44LP, IDV44LPE, IDV44LPE2) versions. Field conversion uses Kingsman kits 36IDV-CKNG \/ -CKLP (millivolt), 36IDV-CKNGI \/ -CKLPI (IPI Proflame 1) or 43IDV-CKNG2 \/ -CKLP2 (IPI Proflame 2).\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Millivolt models need no electricity to run the fire. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in an outage; the blower needs house power and does not run on battery.\u003c\/p\u003e\n\u003ch4\u003eIs a remote included?\u003c\/h4\u003e\u003cp\u003eOn the IDV44NE2 and IDV44LPE2 (Proflame 2) models, yes. The other models take an optional remote: GFRC, GTRC, GTMRCN or GTMRCP on millivolt models, or EGTRC, EGTMRCN or EGTMRCP on IPI Proflame 1 models. Z1MT and Z80PT wall thermostats are also available.\u003c\/p\u003e\n\u003ch4\u003eHow high must a mantel be above the IDV44?\u003c\/h4\u003e\u003cp\u003eWith the I44CV1BL front, a combustible mantel needs a minimum height of 40\" at 0\" depth, rising to 42\", 44\", 45\" and 46\" for mantels 2\", 4\", 6\" and 8\" deep. The optional I33CS mantel clearance shield lowers those to 34\", 36\", 38\", 40\" and 42\".\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Natural Gas \/ Millivolt","offer_id":50912106021026,"sku":"IDV44N","price":3575.41,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50912106053794,"sku":"IDV44LP","price":3650.27,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI","offer_id":50912106086562,"sku":"IDV44NE","price":3992.0,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI","offer_id":50912106119330,"sku":"IDV44LPE","price":4064.45,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ IPI Proflame 2 with Remote","offer_id":50912106152098,"sku":"IDV44NE2","price":4625.93,"currency_code":"USD","in_stock":true},{"title":"Propane \/ IPI Proflame 2 with Remote","offer_id":50912106184866,"sku":"IDV44LPE2","price":4705.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/IDV44N-with-LOGF36-Log-Set-and-IDV36RLT-Liner.jpg?v=1795038598"},{"product_id":"kingsman-five-piece-fibre-split-oak-log-set-logf200","title":"Kingsman Five-Piece Fibre Split Oak Log Set LOGF200","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe LOGF200 is the five-piece fibre split oak log set for the Kingsman FDV200S freestanding direct vent stove. It is the log set the FDV200S needs, and it fills the stove's firebox with a classic wood-stove fire.\u003c\/p\u003e\u003cp\u003eThe logs seat on locating tabs and rest in each other's notches, so they lock into the engineered layout. Glowing ember chunks go on the front burner tube and slotted ember plate.\u003c\/p\u003e\u003cp\u003eKingsman's FDV200S best-selling package pairs the stove with this log set and the FDV200RL brick liner.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFive-piece fibre oak\u003c\/strong\u003e: five ceramic-fibre split oak logs (200S-MAN19 p.16)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotched, tab-located logs\u003c\/strong\u003e: logs seat on locating tabs and in each other's notches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlowing embers\u003c\/strong\u003e: ember chunks on the front burner tube and slotted ember plate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired for the FDV200S\u003c\/strong\u003e: listed as the FDV200S log set (price list)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eLOGF200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKingsman description\u003c\/th\u003e\n\u003ctd\u003eLog Set - Five Piece Fiber Split Oak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePieces\u003c\/th\u003e\n\u003ctd\u003e5 logs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eceramic fibre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eKingsman FDV200S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompatible fireplaces\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-fdv200s-direct-vent-gas-stove-fdv200s\"\u003eKingsman FDV200S stove\u003c\/a\u003e: required (Kingsman price list: Log Set (Required))\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eFive-piece LOGF200 fibre split oak log set\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eA Kingsman FDV200S stove\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFDV200RL refractory brick liner\u003c\/li\u003e\n\u003cli\u003eF45FK fan kit (millivolt\/PF1 models)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2024\/01\/200S-MAN19.pdf\"\u003eFDV200S installation and operating manual (200S-MAN19)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (200S-MAN19). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eUse only the media the appliance manual approves, in the quantities it lists. Parts not approved for the appliance can cause sooting, delayed ignition, property damage or injury.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eLOGC200\/LOGF200 setup (200S-MAN19 p.16)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSeat log 1 on locating tabs 1A and 1B; set log 2 with its hole over tab 2A and its long branch in the notch of log 1.\u003c\/li\u003e\n\u003cli\u003ePlace log 3 forward against tabs 3A and 3B (not on top of them); rest log 4 in the notches of logs 1 and 3; set log 5 against the second grate bar from the left.\u003c\/li\u003e\n\u003cli\u003ePlace the glowing ember chunks on the front burner tube and slotted ember plate, not on the rear burner tube.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDoor and glass (200S-MAN19 pp.4, 17)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eFit or remove the safety screen only when the stove is completely cool.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eUse, care and maintenance\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNever cover the pilot or the pilot-to-burner crossover. You should always be able to see the pilot when lighting; if you cannot, the log or media placement is wrong.\u003c\/li\u003e\n\u003cli\u003eIf sooting appears, turn the fireplace off, let it cool and reposition or remove the piece the flame is touching. Never alter the gas orifice.\u003c\/li\u003e\n\u003cli\u003eLogs, media and the glass get very hot. Only handle them when the fireplace is completely cool, and keep children and pets away from the glass.\u003c\/li\u003e\n\u003cli\u003eHave the logs, burner and pilot inspected and cleaned every year by a qualified service technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (200S-MAN19 p.7).\u003c\/li\u003e\n\u003cli\u003eAny fan or light kit wiring: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1\u003c\/a\u003e in Canada.\u003c\/li\u003e\n\u003cli\u003eManufactured-home installations follow the \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e where the appliance is approved for them.\u003c\/li\u003e\n\u003cli\u003eMassachusetts: a licensed plumber or gas fitter must install the appliance, and CO detectors are required (\u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe log set \/ media is a Kingsman component of the fireplace it is installed in. Kingsman prints its Limited Lifetime Warranty in each appliance manual (200S-MAN19 p.53).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and are done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for an appliance that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada, installed and operated following the manual and local codes. Keep your installation records; without them coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, misuse or negligence, faulty installation, unauthorized alteration, lack of maintenance, corrosive atmospheres, installation or removal costs and incidental or consequential damages.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912155697314,"sku":"LOGF200","price":368.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/logf200_lifestyle-1716494406_1797.png?v=1795048312"},{"product_id":"kingsman-fdv350-black-door-frame-with-ceramic-glass-f35db","title":"Kingsman FDV350 Black Door Frame with Ceramic Glass F35DB","description":"\u003cp\u003eThe F35DB is the black door frame with heat-radiating ceramic glass for the Kingsman FDV350 bay stove. Every FDV350 requires this door front to complete the unit; it is sold separately.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoor frame\u003c\/strong\u003e: black door frame with ceramic glass for the FDV350 bay stove\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired\u003c\/strong\u003e: the FDV350 needs this door frame (price list)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: F35DB\u003c\/li\u003e\n\u003cli\u003eKingsman price list description: Door Frame and Ceramic Glass - Black\u003c\/li\u003e\n\u003cli\u003eFinish: black, ceramic glass\u003c\/li\u003e\n\u003cli\u003eShipping weight: 15 lb\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-fdv350-bay-direct-vent-gas-stove-fdv350\"\u003eKingsman FDV350 stove\u003c\/a\u003e: required (Kingsman price list: Door Front (Required))\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDoor removal: open both side panels, pull the latch handle forward and lift the frame off (350-MAN19 p.15). Replacement glass must be Robax ceramic or coated Neoceram, 5 mm minimum.\u003c\/li\u003e\n\u003cli\u003eInstallation should be done by a qualified installer following the appliance installation manual. United Fireplaces recommends that every appliance and accessory be installed by a qualified professional installer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2024\/01\/350-MAN19.pdf\"\u003eFDV350 installation and operating manual (350-MAN19)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912156123298,"sku":"F35DB","price":937.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/kingsman-f35db-door-frame.jpg?v=1795185973"},{"product_id":"kingsman-fibre-split-oak-log-set-logf35","title":"Kingsman Fibre Split Oak Log Set LOGF35","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe LOGF35 is a fibre split oak log set for the Kingsman FDV350 bay stove and the IDV34 fireplace insert. Fibre logs are light, very durable and hold a natural split-oak colour with crisp bark detail.\u003c\/p\u003e\u003cp\u003eFour logs locate on pins in the log pan with a rear log holder, so the set goes together quickly and always lands where the flame was engineered to meet it. A bag of ember chunks spread one layer deep glows across the front burner.\u003c\/p\u003e\u003cp\u003eIt is the required log set for the FDV350 and one of the media choices for the IDV34 (the other is the RSP10 glass platform).\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFibre split oak\u003c\/strong\u003e: lightweight ceramic-fibre logs with a natural split-oak finish\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin-located\u003c\/strong\u003e: logs A to D sit on locating pins and a rear log holder for repeatable placement (350-MAN19 p.14; 34IDV-MAN19-4 p.30)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlowing ember chunks\u003c\/strong\u003e: ember bag included; spread one layer deep on the front burner and log pan\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo appliances\u003c\/strong\u003e: listed for the FDV350 stove and IDV34 insert\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eLOGF35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKingsman description\u003c\/th\u003e\n\u003ctd\u003eLog Set - Fiber Split Oak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePieces\u003c\/th\u003e\n\u003ctd\u003e4 logs, rear log holder, 4 log pins, ember chunks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eceramic fibre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eKingsman FDV350, IDV34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e12 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompatible fireplaces\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-fdv350-bay-direct-vent-gas-stove-fdv350\"\u003eKingsman FDV350 stove\u003c\/a\u003e: required (Kingsman price list: Log Set (Required))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-idv34-direct-vent-gas-fireplace-insert-idv34\"\u003eKingsman IDV34 insert\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Log Set or Glass Support (Required for Each Unit))\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLogs A, B, C and D\u003c\/li\u003e\n\u003cli\u003eRear log holder\u003c\/li\u003e\n\u003cli\u003eFour log pins\u003c\/li\u003e\n\u003cli\u003eBag of ember chunks\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eA Kingsman FDV350 stove or IDV34 insert\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eF35RL brick liner (FDV350)\u003c\/li\u003e\n\u003cli\u003eIDV33RL brick or IDV33PRL porcelain liner (IDV34)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2024\/01\/350-MAN19.pdf\"\u003eFDV350 installation and operating manual (350-MAN19)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/34IDV-MAN19-4.pdf\"\u003eIDV34 installation and operating manual (34IDV-MAN19-4)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (350-MAN19, 34IDV-MAN19-4). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eIncorrect placement can cause sooting (350-MAN19 p.14; 34IDV-MAN19-4 p.30).\u003c\/li\u003e\n\u003cli\u003eUse only the media the appliance manual approves, in the quantities it lists. Parts not approved for the appliance can cause sooting, delayed ignition, property damage or injury.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eLog installation (350-MAN19 p.14; 34IDV-MAN19-4 p.30)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eLog A: its two locating holes go over the two pins on the left of the mounting pan; log B over the two pins on the right.\u003c\/li\u003e\n\u003cli\u003eLog C: lower it just behind logs A and B, then pull it up against them; log D goes over the two pins on the left of log C.\u003c\/li\u003e\n\u003cli\u003eSpread the ember chunks on the front burner and log pan, no more than one layer deep.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBrick liner order (350-MAN19 p.13)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eIf you add the F35RL brick liner, remove the rear log holder, fit the bricks, reinstall the holder, then the logs and door.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eUse, care and maintenance\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNever cover the pilot or the pilot-to-burner crossover. You should always be able to see the pilot when lighting; if you cannot, the log or media placement is wrong.\u003c\/li\u003e\n\u003cli\u003eIf sooting appears, turn the fireplace off, let it cool and reposition or remove the piece the flame is touching. Never alter the gas orifice.\u003c\/li\u003e\n\u003cli\u003eLogs, media and the glass get very hot. Only handle them when the fireplace is completely cool, and keep children and pets away from the glass.\u003c\/li\u003e\n\u003cli\u003eHave the logs, burner and pilot inspected and cleaned every year by a qualified service technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (350-MAN19 p.7; 34IDV-MAN19-4 p.8).\u003c\/li\u003e\n\u003cli\u003eAny fan or light kit wiring: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1\u003c\/a\u003e in Canada.\u003c\/li\u003e\n\u003cli\u003eManufactured-home installations follow the \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e where the appliance is approved for them.\u003c\/li\u003e\n\u003cli\u003eMassachusetts: a licensed plumber or gas fitter must install the appliance, and CO detectors are required (\u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe log set \/ media is a Kingsman component of the fireplace it is installed in. Kingsman prints its Limited Lifetime Warranty in each appliance manual (350-MAN19 p.53; 34IDV-MAN19-4 p.76).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and are done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for an appliance that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada, installed and operated following the manual and local codes. Keep your installation records; without them coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, misuse or negligence, faulty installation, unauthorized alteration, lack of maintenance, corrosive atmospheres, installation or removal costs and incidental or consequential damages.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912156549282,"sku":"LOGF35","price":469.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/LOGF35-Fibre-Split-Oak.jpg?v=1795047799"},{"product_id":"kingsman-fdv451-door-face-vent-lid-charcoal-f450fbl","title":"Kingsman FDV451 Door Face \u0026 Vent Lid, Charcoal F450FBL","description":"\u003cp\u003eThe F450FBL door face and vent lid finishes the front and top of the Kingsman FDV451 stove in charcoal with flat black posts, and includes the safety screen. One is required for each FDV451.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoor face\u003c\/strong\u003e: charcoal door face with flat black posts, safety screen and vent lid for the FDV451\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired\u003c\/strong\u003e: the FDV451 needs a door front (price list)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: F450FBL\u003c\/li\u003e\n\u003cli\u003eKingsman price list description: Door Face \u0026amp; Vent Lid - Charcoal w\/Flat Black Posts \u0026amp; Safety Screen\u003c\/li\u003e\n\u003cli\u003eFinish: charcoal with flat black posts; safety screen included\u003c\/li\u003e\n\u003cli\u003eShipping weight: 32 lb\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-fdv451-direct-vent-gas-stove-fdv451\"\u003eKingsman FDV451 stove\u003c\/a\u003e: required (Kingsman price list: Door Fronts (Required for Each Unit))\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eF450F kit = door face with safety screen, 2 DT screws and vent lid (451-MAN19-3 p.17).\u003c\/li\u003e\n\u003cli\u003eInstallation should be done by a qualified installer following the appliance installation manual. United Fireplaces recommends that every appliance and accessory be installed by a qualified professional installer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/451-MAN19-3.pdf\"\u003eFDV451 installation and operating manual (451-MAN19-3)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912156582050,"sku":"F450FBL","price":683.45,"currency_code":"USD","in_stock":true}]},{"product_id":"kingsman-fdv451-side-doors-charcoal-solid-panel-f451sdsbl","title":"Kingsman FDV451 Side Doors, Charcoal Solid Panel F451SDSBL","description":"\u003cp\u003eThe F451SDSBL side doors are charcoal solid panels with a black frame for the sides of the Kingsman FDV451 stove. One set is required for each FDV451.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSide doors\u003c\/strong\u003e: charcoal solid side panels with black frames for the FDV451\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired\u003c\/strong\u003e: the FDV451 needs side doors (price list)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: F451SDSBL\u003c\/li\u003e\n\u003cli\u003eKingsman price list description: Charcoal Solid Panel w\/Black Frame\u003c\/li\u003e\n\u003cli\u003eFinish: charcoal solid panel, black frame\u003c\/li\u003e\n\u003cli\u003eShipping weight: 23 lb\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-fdv451-direct-vent-gas-stove-fdv451\"\u003eKingsman FDV451 stove\u003c\/a\u003e: required (Kingsman price list: Side Doors (Required for Each Unit))\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eF451SD kit = pair of side door panels with safety screens and 4 DT screws (451-MAN19-3 p.19). Do not overtighten the nuts (p.15).\u003c\/li\u003e\n\u003cli\u003eInstallation should be done by a qualified installer following the appliance installation manual. United Fireplaces recommends that every appliance and accessory be installed by a qualified professional installer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/451-MAN19-3.pdf\"\u003eFDV451 installation and operating manual (451-MAN19-3)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912156975266,"sku":"F451SDSBL","price":440.74,"currency_code":"USD","in_stock":true}]},{"product_id":"kingsman-fdv451-oak-log-set-logf451","title":"Kingsman FDV451 Oak Log Set LOGF451","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe LOGF451 is Kingsman's six-piece oak log set for the FDV451 freestanding direct vent stove. The oak logs show deep bark texture, split ends and charred edges, so the stove looks like a real wood fire the moment it lights.\u003c\/p\u003e\u003cp\u003eIt sits on the FDV451's dual burner, with the lava rock and 350 glowing embers that ship with the stove spread around the logs. Add the optional F45LG grate bar for a classic andiron look, or pair the logs with a brick or porcelain liner to finish the firebox.\u003c\/p\u003e\u003cp\u003eThe FDV451 needs one media choice: this log set, Z5GC bronze glass, or RBCB1 cannonballs with glass. Choose the LOGF451 if you want the traditional cabin-stove look.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix-piece oak set\u003c\/strong\u003e: six oak logs sized and shaped for the FDV451 firebox (451-MAN19-3 pp.27-28)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRealistic detail\u003c\/strong\u003e: bark texture, split faces and charred ends that glow with the flame\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmbers included with the stove\u003c\/strong\u003e: lava rock and 350 embers ship with the FDV451 and finish the bed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrate option\u003c\/strong\u003e: works with the optional F45LG log grate bar (p.27)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet as shown\u003c\/strong\u003e: placing each log exactly as the manual diagram shows keeps a clean flame and avoids sooting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eLOGF451\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKingsman description\u003c\/th\u003e\n\u003ctd\u003eLog Set - Oak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePieces\u003c\/th\u003e\n\u003ctd\u003e6 logs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eKingsman FDV451\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e9 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompatible fireplaces\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-fdv451-direct-vent-gas-stove-fdv451\"\u003eKingsman FDV451 stove\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Media (1 Required for Each Unit))\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eSix-piece LOGF451 oak log set (logs 1-6)\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eA Kingsman FDV451 stove (the lava rock and 350 embers come with the stove)\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eF45LG log grate\u003c\/li\u003e\n\u003cli\u003eF451RLT traditional, F451RLH herringbone brick liner or F451PL porcelain liner\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/451-MAN19-3.pdf\"\u003eFDV451 installation and operating manual (451-MAN19-3)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (451-MAN19-3). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eThe FDV451 must operate with its glass door closed; never run it with the glass removed, cracked or broken (451-MAN19-3 p.13).\u003c\/li\u003e\n\u003cli\u003eUse only the media the appliance manual approves, in the quantities it lists. Parts not approved for the appliance can cause sooting, delayed ignition, property damage or injury.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eLogs and media (pp.26-35)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003ePlace log 1 against the back wall and spread lava rock along the sides of the false bottom.\u003c\/li\u003e\n\u003cli\u003ePlace log 2, then logs 3 and 4, then logs 5 and 6 as shown in the diagrams (pp.27-28).\u003c\/li\u003e\n\u003cli\u003ePlace the 350 embers in the areas shown. The optional F45LG grate bar may be used (p.26).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDoors and glass (pp.13-20)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eRemove the glass front with the supplied latch tool only when the stove is completely cool; reinstall by engaging the bottom ledge first (pp.13-14).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eUse, care and maintenance\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNever cover the pilot or the pilot-to-burner crossover. You should always be able to see the pilot when lighting; if you cannot, the log or media placement is wrong.\u003c\/li\u003e\n\u003cli\u003eIf sooting appears, turn the fireplace off, let it cool and reposition or remove the piece the flame is touching. Never alter the gas orifice.\u003c\/li\u003e\n\u003cli\u003eLogs, media and the glass get very hot. Only handle them when the fireplace is completely cool, and keep children and pets away from the glass.\u003c\/li\u003e\n\u003cli\u003eHave the logs, burner and pilot inspected and cleaned every year by a qualified service technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (451-MAN19-3 p.5).\u003c\/li\u003e\n\u003cli\u003eAny fan or light kit wiring: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1\u003c\/a\u003e in Canada.\u003c\/li\u003e\n\u003cli\u003eManufactured-home installations follow the \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e where the appliance is approved for them.\u003c\/li\u003e\n\u003cli\u003eMassachusetts: a licensed plumber or gas fitter must install the appliance, and CO detectors are required (\u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe log set \/ media is a Kingsman component of the fireplace it is installed in. Kingsman prints its Limited Lifetime Warranty in each appliance manual (451-MAN19-3 p.76).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and are done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for an appliance that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada, installed and operated following the manual and local codes. Keep your installation records; without them coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, misuse or negligence, faulty installation, unauthorized alteration, lack of maintenance, corrosive atmospheres, installation or removal costs and incidental or consequential damages.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912157040802,"sku":"LOGF451","price":539.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/LOGF451-Oak-Log-Set.jpg?v=1795047800"},{"product_id":"kingsman-1-2-bronze-glass-media-5-lb-bag-z5gc","title":"Kingsman 1\/2\" Bronze Glass Media, 5 lb Bag Z5GC","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eZ5GC is Kingsman's 1\/2\" bronze decorative glass media, sold in 5 lb bags. Warm bronze glass sparkles under the flame and gives a clean, contemporary fire with no logs.\u003c\/p\u003e\u003cp\u003eIt is approved in specific Kingsman appliances, including the FDV451, ZCV34, ZCV39\/42 with glass tray, MCVP42\/MCVST42 with glass tray and the IDV24. Order the number of bags your appliance needs and never exceed its maximum glass weight.\u003c\/p\u003e\u003cp\u003eGlass is also the base for RBCB1 cannonballs and driftwood sets where the manual allows.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1\/2\" bronze glass\u003c\/strong\u003e: Kingsman decorative bronze glass (34ZCV-MAN19-21 p.43)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5 lb bags\u003c\/strong\u003e: order by the bag to reach the appliance's required amount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContemporary fire\u003c\/strong\u003e: reflects and sparkles under the flame\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase for other media\u003c\/strong\u003e: used under cannonballs and driftwood where approved\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eZ5GC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKingsman description\u003c\/th\u003e\n\u003ctd\u003eGlass Media - 1\/2\" Bronze -  5 lbs. (MAX 10 LBS. GLASS PER MANUAL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSize \/ colour\u003c\/th\u003e\n\u003ctd\u003e1\/2\" bronze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBag weight\u003c\/th\u003e\n\u003ctd\u003e5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum per appliance\u003c\/th\u003e\n\u003ctd\u003eZCV34 10 lb (p.43); ZCV39 15 lb, ZCV42 20 lb (39ZCV-MAN19-16 pp.75-77); IDV24 10 lb (24IDV-MAN19-6 p.21); FDV451 15 lb (451-MAN19-3 p.34); MCV42 glass tray per the price list 10 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompatible fireplaces\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-fdv451-direct-vent-gas-stove-fdv451\"\u003eKingsman FDV451 stove\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Media (1 Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv34-clean-view-direct-vent-gas-fireplace-zcv34\"\u003eKingsman ZCV34 fireplace\u003c\/a\u003e: one of the required choices (Kingsman price list: Choose Log Set or Glass Media Accessories)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv34h-heater-rated-clean-view-fireplace-zcv34h\"\u003eKingsman ZCV34H heater-rated fireplace\u003c\/a\u003e: one of the required choices (Kingsman price list: Choose Log Set or Glass Media)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv39-clean-view-direct-vent-gas-fireplace-zcv39\"\u003eKingsman ZCV39 fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Log Set, Rock Set, or Glass Set (One Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv39h-heater-rated-clean-view-fireplace-zcv39h\"\u003eKingsman ZCV39H heater-rated fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Log Set, Rock Set, or Glass Set (One Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv42-clean-view-direct-vent-gas-fireplace-zcv42\"\u003eKingsman ZCV42 fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Log Set, Rock Set, Or Glass Set (One Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv42h-heater-rated-clean-view-fireplace-zcv42h\"\u003eKingsman ZCV42H heater-rated fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Log Set, Rock Set, or Glass Set (One Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-mcvp42-peninsula-direct-vent-gas-fireplace-mcvp42\"\u003eKingsman MCVP42 peninsula fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Choose Log Grate \u0026amp; Log Set or Glassy Tray \u0026amp; Media (Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-mcvp42h-heater-rated-peninsula-fireplace-mcvp42h\"\u003eKingsman MCVP42H heater-rated peninsula fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Choose Log Grate \u0026amp; Log Set or Glass Tray \u0026amp; Media (Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-mcvst42-see-through-gas-fireplace-mcvst42\"\u003eKingsman MCVST42 see-through fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Choose Log Grate \u0026amp; Log Set or Glass Tray \u0026amp; Media (Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-mcvst42h-heater-rated-see-through-fireplace-mcvst42h\"\u003eKingsman MCVST42H heater-rated see-through fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Choose Log Grate \u0026amp; Log Set or Glass Tray \u0026amp; Media (Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-idv24-direct-vent-gas-fireplace-insert-idv24\"\u003eKingsman IDV24 insert\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Choose Log Set or Glass Media (Required))\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eOne 5 lb bag of Z5GC 1\/2\" bronze glass\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eAn approved Kingsman appliance; ZCV39\/42 and MCV42 need their glass tray\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRBCB1 cannonballs\u003c\/li\u003e\n\u003cli\u003eULK2 \/ ULK3 light kits (glass-tray units)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/451-MAN19-3.pdf\"\u003eFDV451 installation and operating manual (451-MAN19-3)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2022\/05\/34ZCV-MAN19-21.pdf\"\u003eZCV34 installation and operating manual (34ZCV-MAN19-21)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/39ZCV-MAN19-16.pdf\"\u003eZCV39 installation and operating manual (39ZCV-MAN19-16)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/42MCVP-MAN19.pdf\"\u003eMCVP42 installation and operating manual (42MCVP-MAN19)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/42MCVST-MAN19-8.pdf\"\u003eMCVST42 installation and operating manual (42MCVST-MAN19-8)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2022\/09\/24IDV-MAN19-6.pdf\"\u003eIDV24 installation and operating manual (24IDV-MAN19-6)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (451-MAN19-3, 34ZCV-MAN19-21, 39ZCV-MAN19-16, 42MCVP-MAN19, 42MCVST-MAN19-8, 24IDV-MAN19-6). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eUse only the media the appliance manual approves, in the quantities it lists. Parts not approved for the appliance can cause sooting, delayed ignition, property damage or injury.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eGlass media placement\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSpread the glass evenly over the burner and false bottom (or tray) without heavy overlap, which affects the flame pattern (34ZCV-MAN19-21 p.43; 24IDV-MAN19-6 p.21).\u003c\/li\u003e\n\u003cli\u003eKeep glass off the pilot area and the crossover holes; delayed ignition can occur.\u003c\/li\u003e\n\u003cli\u003eUse only factory-approved glass; other glass can alter performance and is not covered under warranty (39ZCV-MAN19-16 pp.75-77).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eUse, care and maintenance\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNever cover the pilot or the pilot-to-burner crossover. You should always be able to see the pilot when lighting; if you cannot, the log or media placement is wrong.\u003c\/li\u003e\n\u003cli\u003eIf sooting appears, turn the fireplace off, let it cool and reposition or remove the piece the flame is touching. Never alter the gas orifice.\u003c\/li\u003e\n\u003cli\u003eLogs, media and the glass get very hot. Only handle them when the fireplace is completely cool, and keep children and pets away from the glass.\u003c\/li\u003e\n\u003cli\u003eHave the logs, burner and pilot inspected and cleaned every year by a qualified service technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (451-MAN19-3 p.5; 34ZCV-MAN19-21 p.5; 39ZCV-MAN19-16 p.5-9; 42MCVP-MAN19 p.5; 42MCVST-MAN19-8 p.5; 24IDV-MAN19-6 p.7).\u003c\/li\u003e\n\u003cli\u003eAny fan or light kit wiring: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1\u003c\/a\u003e in Canada.\u003c\/li\u003e\n\u003cli\u003eManufactured-home installations follow the \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e where the appliance is approved for them.\u003c\/li\u003e\n\u003cli\u003eMassachusetts: a licensed plumber or gas fitter must install the appliance, and CO detectors are required (\u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe log set \/ media is a Kingsman component of the fireplace it is installed in. Kingsman prints its Limited Lifetime Warranty in each appliance manual (451-MAN19-3 p.76; 34ZCV-MAN19-21 p.94; 39ZCV-MAN19-16 p.122; 42MCVP-MAN19 p.81; 42MCVST-MAN19-8 p.89; 24IDV-MAN19-6 p.58).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and are done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for an appliance that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada, installed and operated following the manual and local codes. Keep your installation records; without them coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, misuse or negligence, faulty installation, unauthorized alteration, lack of maintenance, corrosive atmospheres, installation or removal costs and incidental or consequential damages.\u003c\/li\u003e\n\u003cli\u003eDiscoloration of glass media placed on the burner is not covered under warranty (24IDV-MAN19-6 p.21).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912157466786,"sku":"Z5GC","price":143.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/kingsman-1-2-bronze-glass-media-15-pounds-28.gif?v=1795048314"},{"product_id":"kingsman-multi-colored-cannonballs-rbcb1","title":"Kingsman Multi-Colored Cannonballs RBCB1","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eRBCB1 is a set of assorted-size, multi-coloured ceramic cannonballs for a modern fire. Scattered over decorative glass, the spheres catch the flame and add a sculptural, contemporary look.\u003c\/p\u003e\u003cp\u003eKingsman approves RBCB1 in specific appliances: the FDV451 stove, ZCV34\/39\/42, ZCVRB47\/60\/72, MCVP42\/MCVST42 and the IDV24. In most of these it is used together with glass media or on the glass tray, so plan the glass at the same time.\u003c\/p\u003e\u003cp\u003ePlacement is random, but never directly on burner ports or over the pilot.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssorted sizes and colours\u003c\/strong\u003e: multi-coloured ceramic cannonballs placed randomly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModern look\u003c\/strong\u003e: a sculptural alternative to logs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorks with glass\u003c\/strong\u003e: combine with MQ glass, Kingsman bronze glass, embers or lava rock where the manual allows\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide compatibility\u003c\/strong\u003e: approved in 15 Kingsman appliances (price list)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRBCB1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKingsman description\u003c\/th\u003e\n\u003ctd\u003eCannonballs - Assorted Size and Colors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContents\u003c\/th\u003e\n\u003ctd\u003eassorted cannonballs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e16.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompatible fireplaces\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-fdv451-direct-vent-gas-stove-fdv451\"\u003eKingsman FDV451 stove\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Media (1 Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcvrb47-47-linear-gas-fireplace-zcvrb47\"\u003eKingsman ZCVRB47 linear fireplace\u003c\/a\u003e: optional accessory (Kingsman price list: Optional Fireplace Accessories)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcvrb60-60-linear-gas-fireplace-zcvrb60\"\u003eKingsman ZCVRB60 linear fireplace\u003c\/a\u003e: optional accessory (Kingsman price list: Optional Fireplace Accessories)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcvrb72-72-linear-gas-fireplace-zcvrb72\"\u003eKingsman ZCVRB72 linear fireplace\u003c\/a\u003e: optional accessory (Kingsman price list: Optional Fireplace Accessories)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv34-clean-view-direct-vent-gas-fireplace-zcv34\"\u003eKingsman ZCV34 fireplace\u003c\/a\u003e: optional accessory (Kingsman price list: Optional Media Accessories)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv34h-heater-rated-clean-view-fireplace-zcv34h\"\u003eKingsman ZCV34H heater-rated fireplace\u003c\/a\u003e: one of the required choices (Kingsman price list: Choose Media Accessories)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv39-clean-view-direct-vent-gas-fireplace-zcv39\"\u003eKingsman ZCV39 fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Log Set, Rock Set, or Glass Set (One Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv39h-heater-rated-clean-view-fireplace-zcv39h\"\u003eKingsman ZCV39H heater-rated fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Log Set, Rock Set, or Glass Set (One Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv42-clean-view-direct-vent-gas-fireplace-zcv42\"\u003eKingsman ZCV42 fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Log Set, Rock Set, Or Glass Set (One Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv42h-heater-rated-clean-view-fireplace-zcv42h\"\u003eKingsman ZCV42H heater-rated fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Log Set, Rock Set, or Glass Set (One Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-mcvp42-peninsula-direct-vent-gas-fireplace-mcvp42\"\u003eKingsman MCVP42 peninsula fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Choose Log Grate \u0026amp; Log Set or Glassy Tray \u0026amp; Media (Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-mcvp42h-heater-rated-peninsula-fireplace-mcvp42h\"\u003eKingsman MCVP42H heater-rated peninsula fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Choose Log Grate \u0026amp; Log Set or Glass Tray \u0026amp; Media (Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-mcvst42-see-through-gas-fireplace-mcvst42\"\u003eKingsman MCVST42 see-through fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Choose Log Grate \u0026amp; Log Set or Glass Tray \u0026amp; Media (Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-mcvst42h-heater-rated-see-through-fireplace-mcvst42h\"\u003eKingsman MCVST42H heater-rated see-through fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Choose Log Grate \u0026amp; Log Set or Glass Tray \u0026amp; Media (Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-idv24-direct-vent-gas-fireplace-insert-idv24\"\u003eKingsman IDV24 insert\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Choose Log Set or Glass Media (Required))\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eRBCB1 assorted cannonballs\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAn approved Kingsman appliance\u003c\/li\u003e\n\u003cli\u003eGlass media \/ glass tray where the manual requires it: FDV451 must use 15 lb of glass (451-MAN19-3 p.33); ZCV39\/42 and MCV42 require the glass tray (39ZCV-MAN19-16 p.74; 42MCVP-MAN19 p.37)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZ5GC bronze glass media\u003c\/li\u003e\n\u003cli\u003eULK2 \/ ULK3 light kits (glass-tray units)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/451-MAN19-3.pdf\"\u003eFDV451 installation and operating manual (451-MAN19-3)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/47ZCV-MAN19-11.pdf\"\u003eZCVRB47 installation and operating manual (47ZCV-MAN19-11)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2024\/01\/60ZCV-MAN19-2.pdf\"\u003eZCVRB60 installation and operating manual (60ZCV-MAN19-2)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2024\/01\/72ZCV-MAN19-8.pdf\"\u003eZCVRB72 installation and operating manual (72ZCV-MAN19-8)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2022\/05\/34ZCV-MAN19-21.pdf\"\u003eZCV34 installation and operating manual (34ZCV-MAN19-21)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/39ZCV-MAN19-16.pdf\"\u003eZCV39 installation and operating manual (39ZCV-MAN19-16)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/42MCVP-MAN19.pdf\"\u003eMCVP42 installation and operating manual (42MCVP-MAN19)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/42MCVST-MAN19-8.pdf\"\u003eMCVST42 installation and operating manual (42MCVST-MAN19-8)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2022\/09\/24IDV-MAN19-6.pdf\"\u003eIDV24 installation and operating manual (24IDV-MAN19-6)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (451-MAN19-3, 47ZCV-MAN19-11, 60ZCV-MAN19-2, 72ZCV-MAN19-8, 34ZCV-MAN19-21, 39ZCV-MAN19-16, 42MCVP-MAN19, 42MCVST-MAN19-8, 24IDV-MAN19-6). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eUse only the media the appliance manual approves, in the quantities it lists. Parts not approved for the appliance can cause sooting, delayed ignition, property damage or injury.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eCannonball placement\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003ePlace randomly; do not place cannonballs directly on burner ports (451-MAN19-3 p.33; 34ZCV-MAN19-21 p.45; 24IDV-MAN19-6 p.23).\u003c\/li\u003e\n\u003cli\u003eIDV24: do not use large cannonballs; lava rock cannot go on the burner (24IDV-MAN19-6 p.23).\u003c\/li\u003e\n\u003cli\u003eThe supplied lava rock cannot be placed on the burner in the MCV42 (42MCVP-MAN19 p.37).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eUse, care and maintenance\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNever cover the pilot or the pilot-to-burner crossover. You should always be able to see the pilot when lighting; if you cannot, the log or media placement is wrong.\u003c\/li\u003e\n\u003cli\u003eIf sooting appears, turn the fireplace off, let it cool and reposition or remove the piece the flame is touching. Never alter the gas orifice.\u003c\/li\u003e\n\u003cli\u003eLogs, media and the glass get very hot. Only handle them when the fireplace is completely cool, and keep children and pets away from the glass.\u003c\/li\u003e\n\u003cli\u003eHave the logs, burner and pilot inspected and cleaned every year by a qualified service technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (451-MAN19-3 p.5; 47ZCV-MAN19-11 p.5; 60ZCV-MAN19-2 p.5; 72ZCV-MAN19-8 p.5; 34ZCV-MAN19-21 p.5; 39ZCV-MAN19-16 p.5-9; 42MCVP-MAN19 p.5; 42MCVST-MAN19-8 p.5; 24IDV-MAN19-6 p.7).\u003c\/li\u003e\n\u003cli\u003eAny fan or light kit wiring: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1\u003c\/a\u003e in Canada.\u003c\/li\u003e\n\u003cli\u003eManufactured-home installations follow the \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e where the appliance is approved for them.\u003c\/li\u003e\n\u003cli\u003eMassachusetts: a licensed plumber or gas fitter must install the appliance, and CO detectors are required (\u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe log set \/ media is a Kingsman component of the fireplace it is installed in. Kingsman prints its Limited Lifetime Warranty in each appliance manual (451-MAN19-3 p.76; 47ZCV-MAN19-11 p.91; 60ZCV-MAN19-2 p.90; 72ZCV-MAN19-8 p.92; 34ZCV-MAN19-21 p.94; 39ZCV-MAN19-16 p.122; 42MCVP-MAN19 p.81; 42MCVST-MAN19-8 p.89; 24IDV-MAN19-6 p.58).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and are done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for an appliance that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada, installed and operated following the manual and local codes. Keep your installation records; without them coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, misuse or negligence, faulty installation, unauthorized alteration, lack of maintenance, corrosive atmospheres, installation or removal costs and incidental or consequential damages.\u003c\/li\u003e\n\u003cli\u003eDiscoloration of glass media placed on the burner is not covered under warranty (24IDV-MAN19-6 p.21).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912157532322,"sku":"RBCB1","price":412.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/RBCB1-Multi-Colored-Cannonballs_3d0ada00-27b9-4b19-86e5-6e050a5a5626.jpg?v=1795047800"},{"product_id":"kingsman-zcv3622-split-oak-log-set-logc51","title":"Kingsman ZCV3622 Split Oak Log Set LOGC51","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe LOGC51 is the five-piece split oak log set made for the Kingsman ZCV3622 36\" clean view fireplace. Cast logs with split faces and bark detail sit over the burner for a cosy, traditional fire.\u003c\/p\u003e\u003cp\u003eLogs locate on the pilot shield and mount tabs, with lava rock piled around the burner tube and glowing embers along its sides and front. Log 4 has an optional raised position so you can tune the look.\u003c\/p\u003e\u003cp\u003eIt is the log set Kingsman lists for the ZCV3622 in the current price book.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFive-piece split oak\u003c\/strong\u003e: five cast logs with split-oak faces (36ZCV-MAN19-5 pp.28-29)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTab-mounted\u003c\/strong\u003e: logs locate on mount tabs A, B and C for a consistent layout\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable look\u003c\/strong\u003e: optional raised position for log 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMade for the ZCV3622\u003c\/strong\u003e: engineered around the ZCV3622 burner and pilot\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eLOGC51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKingsman description\u003c\/th\u003e\n\u003ctd\u003eLog Set - Split Oak (ZCV3622)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePieces\u003c\/th\u003e\n\u003ctd\u003e5 logs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003ecast refractory logs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eKingsman ZCV3622\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompatible fireplaces\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv3622-36-direct-vent-gas-fireplace-zcv3622\"\u003eKingsman ZCV3622 fireplace\u003c\/a\u003e: required (Kingsman price list: Log Set (Required for Each Unit))\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eFive-piece LOGC51 split oak log set\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eA Kingsman ZCV3622 fireplace (lava rock and embers per the manual)\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZCV3622ML metal brick or ZCV3622PRL porcelain liner\u003c\/li\u003e\n\u003cli\u003eVLBIT6 log bits\u003c\/li\u003e\n\u003cli\u003eZ36FK fan kit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/36ZCV-MAN19-5.pdf\"\u003eZCV3622 installation and operating manual (36ZCV-MAN19-5)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (36ZCV-MAN19-5). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eUse only the media the appliance manual approves, in the quantities it lists. Parts not approved for the appliance can cause sooting, delayed ignition, property damage or injury.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eLOGC51 placement (36ZCV-MAN19-5 pp.28-29)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eLog 1 sits on the pilot shield, left of the pilot; log 2 rests on mount tab A and over tab B.\u003c\/li\u003e\n\u003cli\u003ePile lava rock around the sides of the burner tube; log 3 sits in the centre of the burner on top of log 1; log 4 rests on mount tab C (optional raised position); log 5 sits on lava rock on the right.\u003c\/li\u003e\n\u003cli\u003ePlace glowing embers on the sides and front of the burner tube only. If mount holes are missing, holes A and C may be drilled with a 1\/4\" bit no deeper than 1\/2\"; hole B is not drilled.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDoor and glass (36ZCV-MAN19-5 p.27)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eReplacement glass is 5 mm tempered; a substitute glass voids all warranties.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eUse, care and maintenance\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNever cover the pilot or the pilot-to-burner crossover. You should always be able to see the pilot when lighting; if you cannot, the log or media placement is wrong.\u003c\/li\u003e\n\u003cli\u003eIf sooting appears, turn the fireplace off, let it cool and reposition or remove the piece the flame is touching. Never alter the gas orifice.\u003c\/li\u003e\n\u003cli\u003eLogs, media and the glass get very hot. Only handle them when the fireplace is completely cool, and keep children and pets away from the glass.\u003c\/li\u003e\n\u003cli\u003eHave the logs, burner and pilot inspected and cleaned every year by a qualified service technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (36ZCV-MAN19-5 p.7).\u003c\/li\u003e\n\u003cli\u003eAny fan or light kit wiring: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1\u003c\/a\u003e in Canada.\u003c\/li\u003e\n\u003cli\u003eManufactured-home installations follow the \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e where the appliance is approved for them.\u003c\/li\u003e\n\u003cli\u003eMassachusetts: a licensed plumber or gas fitter must install the appliance, and CO detectors are required (\u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe log set \/ media is a Kingsman component of the fireplace it is installed in. Kingsman prints its Limited Lifetime Warranty in each appliance manual (36ZCV-MAN19-5 p.77).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and are done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for an appliance that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada, installed and operated following the manual and local codes. Keep your installation records; without them coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, misuse or negligence, faulty installation, unauthorized alteration, lack of maintenance, corrosive atmospheres, installation or removal costs and incidental or consequential damages.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912157958306,"sku":"LOGC51","price":521.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/LOGC51-Oak-Log-Set.jpg?v=1795047800"},{"product_id":"kingsman-zcvrb3622-surround-trim-kit-black-zcvrb36sbl","title":"Kingsman ZCVRB3622 Surround Trim Kit, Black ZCVRB36SBL","description":"\u003cp\u003eThe ZCVRB36SBL is a 1 1\/2\" wide black surround trim kit for the Kingsman ZCVRB3622 linear fireplace. The ZCVRB3622 requires one surround, because its opening must be covered to within 1\/8\" with noncombustible material.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean finish\u003c\/strong\u003e: covers the gap between the appliance and the finished wall\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinish\u003c\/strong\u003e: black\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: ZCVRB36SBL\u003c\/li\u003e\n\u003cli\u003eKingsman price list description: Surround Trim Kit -1 1\/2” Wide - Black\u003c\/li\u003e\n\u003cli\u003eWidth 1 1\/2\", black; covers 36\" W x 22 1\/2\" H\u003c\/li\u003e\n\u003cli\u003eShipping weight: 13 lb\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcvrb3622-36-linear-gas-fireplace-zcvrb3622\"\u003eKingsman ZCVRB3622 linear fireplace\u003c\/a\u003e: optional accessory (Kingsman price list: The fireplace must be covered up to an 1\/8” of the opening with noncombustible materials.)\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSurround 36\" W x 22-7\/8\" with a 1\" thick frame, side fillers and 6 screws (36ZCV manual p.22).\u003c\/li\u003e\n\u003cli\u003eInstallation should be done by a qualified installer following the appliance installation manual. United Fireplaces recommends that every appliance and accessory be installed by a qualified professional installer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/36ZCV-MAN19-4.pdf\"\u003eZCVRB3622 installation and operating manual (36ZCV-MAN19-4)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912158384290,"sku":"ZCVRB36SBL","price":518.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/kgm-zcvrb36sbl_1-1761501072_9797.jpg?v=1795048315"},{"product_id":"kingsman-zcvrb3622-surround-trim-kit-stainless-zcvrb36sss","title":"Kingsman ZCVRB3622 Surround Trim Kit, Stainless ZCVRB36SSS","description":"\u003cp\u003eThe ZCVRB36SSS is a 1 1\/2\" wide stainless steel surround trim kit for the Kingsman ZCVRB3622 linear fireplace, which requires one surround to cover the opening to within 1\/8\".\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean finish\u003c\/strong\u003e: covers the gap between the appliance and the finished wall\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinish\u003c\/strong\u003e: stainless steel\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: ZCVRB36SSS\u003c\/li\u003e\n\u003cli\u003eKingsman price list description: Surround Trim Kit - 1 1\/2” Wide - Stainless Steel\u003c\/li\u003e\n\u003cli\u003eWidth 1 1\/2\", stainless steel; covers 36\" W x 22 1\/2\" H\u003c\/li\u003e\n\u003cli\u003eShipping weight: 10 lb\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcvrb3622-36-linear-gas-fireplace-zcvrb3622\"\u003eKingsman ZCVRB3622 linear fireplace\u003c\/a\u003e: optional accessory (Kingsman price list: The fireplace must be covered up to an 1\/8” of the opening with noncombustible materials.)\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSurround 36\" W x 22-7\/8\" with a 1\" thick frame, side fillers and 6 screws (36ZCV manual p.22).\u003c\/li\u003e\n\u003cli\u003eInstallation should be done by a qualified installer following the appliance installation manual. United Fireplaces recommends that every appliance and accessory be installed by a qualified professional installer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/36ZCV-MAN19-4.pdf\"\u003eZCVRB3622 installation and operating manual (36ZCV-MAN19-4)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912158417058,"sku":"ZCVRB36SSS","price":860.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/ZCVRB36SSS-A-12-20.jpg?v=1795048629"},{"product_id":"kingsman-zcvrb3622-flat-surround-black-zcvrb36swfbl","title":"Kingsman ZCVRB3622 Flat Surround, Black ZCVRB36SWFBL","description":"\u003cp\u003eThe ZCVRB36SWFBL flat black surround covers the full framing dimensions of the Kingsman ZCVRB3622 linear fireplace for a clean, finished face without additional wall finishing at the opening. It satisfies the ZCVRB3622's surround requirement.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean finish\u003c\/strong\u003e: covers the gap between the appliance and the finished wall\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinish\u003c\/strong\u003e: black\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: ZCVRB36SWFBL\u003c\/li\u003e\n\u003cli\u003eKingsman price list description: Flat Surround - Covers Framing Dimensions of Skyline - Clean View - Unit Must be Finished Flush to Drywall\u003c\/li\u003e\n\u003cli\u003eFlat, black; covers 45 11\/16\" W x 34 5\/8\" H\u003c\/li\u003e\n\u003cli\u003eShipping weight: 15 lb (estimated)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcvrb3622-36-linear-gas-fireplace-zcvrb3622\"\u003eKingsman ZCVRB3622 linear fireplace\u003c\/a\u003e: optional accessory (Kingsman price list: The fireplace must be covered up to an 1\/8” of the opening with noncombustible materials.)\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFlat surround frame with 2 screws; the unit is raised 1\/2\" (36ZCV manual p.21).\u003c\/li\u003e\n\u003cli\u003eInstallation should be done by a qualified installer following the appliance installation manual. United Fireplaces recommends that every appliance and accessory be installed by a qualified professional installer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/36ZCV-MAN19-4.pdf\"\u003eZCVRB3622 installation and operating manual (36ZCV-MAN19-4)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912158843042,"sku":"ZCVRB36SWFBL","price":572.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/1O5OfOOTBKDkKvJlpid43LcLKPVhaqbFF.jpg?v=1795048314"},{"product_id":"kingsman-eight-piece-burnt-oak-log-set-logc44","title":"Kingsman Eight-Piece Burnt Oak Log Set LOGC44","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe LOGC44 is an eight-piece burnt oak log set with heavy charring and deep bark relief. It is the required log set for the Kingsman HBZDV3624, HBZDV3628, HBZDV4224 and HBZDV4228 fireplaces and a media choice for the ZCV34 and ZCV34H.\u003c\/p\u003e\u003cp\u003eEight logs stack over the dual burner with glowing embers on the front burner tube and crushed rock on the firebox floor, giving a deep, layered traditional fire that looks right from any angle.\u003c\/p\u003e\u003cp\u003eIn the ZCV34 it uses the log support and ember plates supplied with the fireplace; with a porcelain or brick liner it becomes the classic Kingsman look shown in the photos.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEight-piece burnt oak\u003c\/strong\u003e: eight cast logs with charred, burnt-oak detail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLayered fire\u003c\/strong\u003e: logs build up over the dual burner for depth and height\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlowing embers\u003c\/strong\u003e: embers broken into dime and nickel sized pieces go on the front burner tube (36HB-MAN19 pp.27-29)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFive fireplaces\u003c\/strong\u003e: required for HBZDV36\/42 models and a media choice for ZCV34\/34H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eLOGC44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKingsman description\u003c\/th\u003e\n\u003ctd\u003eLog Set - Eight Piece - Burnt Oak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePieces\u003c\/th\u003e\n\u003ctd\u003e8 logs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003ecast refractory logs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eHBZDV3624, HBZDV3628, HBZDV4224, HBZDV4228, ZCV34, ZCV34H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e14 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompatible fireplaces\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-hbzdv3624-36-direct-vent-gas-fireplace-hbzdv3624\"\u003eKingsman HBZDV3624 fireplace\u003c\/a\u003e: required (Kingsman price list: Log Set (Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-hbzdv3628-36-direct-vent-gas-fireplace-hbzdv3628\"\u003eKingsman HBZDV3628 fireplace\u003c\/a\u003e: required (Kingsman price list: Log Set (Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-hbzdv4224-42-direct-vent-gas-fireplace-hbzdv4224\"\u003eKingsman HBZDV4224 fireplace\u003c\/a\u003e: required (Kingsman price list: Log Set (Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-hbzdv4228-42-direct-vent-gas-fireplace-hbzdv4228\"\u003eKingsman HBZDV4228 fireplace\u003c\/a\u003e: required (Kingsman price list: Log Set (Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv34-clean-view-direct-vent-gas-fireplace-zcv34\"\u003eKingsman ZCV34 fireplace\u003c\/a\u003e: one of the required choices (Kingsman price list: Choose Log Set or Glass Media Accessories)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv34h-heater-rated-clean-view-fireplace-zcv34h\"\u003eKingsman ZCV34H heater-rated fireplace\u003c\/a\u003e: one of the required choices (Kingsman price list: Choose Log Set or Glass Media)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eEight-piece LOGC44 burnt oak log set\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eA listed Kingsman fireplace; the ZCV34 log support, ember plates, 350 embers and 3\/4\" lava rock come with the ZCV34 (34ZCV-MAN19-21 pp.46-47)\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBrick or porcelain liner for your fireplace\u003c\/li\u003e\n\u003cli\u003eVLBIT6 log bits\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/36HB-MAN19.pdf\"\u003eHBZDV3624 installation and operating manual (36HB-MAN19)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/42HB-MAN19.pdf\"\u003eHBZDV4224 installation and operating manual (42HB-MAN19)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2022\/05\/34ZCV-MAN19-21.pdf\"\u003eZCV34 installation and operating manual (34ZCV-MAN19-21)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (36HB-MAN19, 42HB-MAN19, 34ZCV-MAN19-21). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eUse only the media the appliance manual approves, in the quantities it lists. Parts not approved for the appliance can cause sooting, delayed ignition, property damage or injury.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eHBZDV36\/42 log placement (36HB-MAN19 pp.27-29)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003ePlace logs 1 to 8 in the numbered order shown.\u003c\/li\u003e\n\u003cli\u003eEmbers go on the front burner tube only, not on the rear burner or crossover tube; crushed rock on the firebox bottom, never on the burners.\u003c\/li\u003e\n\u003cli\u003eIf the flame touching the rocks causes soot, move or remove those rocks (p.29). The 42HB-MAN19 manual has the same LOGC44 section for the HBZDV42 models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eZCV34 log placement (34ZCV-MAN19-21 pp.46-47)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBend the forked tabs of the supplied ember plates down 90 degrees and fit the log support.\u003c\/li\u003e\n\u003cli\u003ePlace the eight logs in sequence; embers cover about 50-60% of the burner tube. Remove embers if sooting occurs.\u003c\/li\u003e\n\u003cli\u003eRemove the log holder if you are not using the LOGC44.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eUse, care and maintenance\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNever cover the pilot or the pilot-to-burner crossover. You should always be able to see the pilot when lighting; if you cannot, the log or media placement is wrong.\u003c\/li\u003e\n\u003cli\u003eIf sooting appears, turn the fireplace off, let it cool and reposition or remove the piece the flame is touching. Never alter the gas orifice.\u003c\/li\u003e\n\u003cli\u003eLogs, media and the glass get very hot. Only handle them when the fireplace is completely cool, and keep children and pets away from the glass.\u003c\/li\u003e\n\u003cli\u003eHave the logs, burner and pilot inspected and cleaned every year by a qualified service technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (36HB-MAN19 p.7; 42HB-MAN19 p.7; 34ZCV-MAN19-21 p.5).\u003c\/li\u003e\n\u003cli\u003eAny fan or light kit wiring: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1\u003c\/a\u003e in Canada.\u003c\/li\u003e\n\u003cli\u003eManufactured-home installations follow the \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e where the appliance is approved for them.\u003c\/li\u003e\n\u003cli\u003eMassachusetts: a licensed plumber or gas fitter must install the appliance, and CO detectors are required (\u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe log set \/ media is a Kingsman component of the fireplace it is installed in. Kingsman prints its Limited Lifetime Warranty in each appliance manual (36HB-MAN19 p.77; 42HB-MAN19 p.73; 34ZCV-MAN19-21 p.94).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and are done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for an appliance that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada, installed and operated following the manual and local codes. Keep your installation records; without them coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, misuse or negligence, faulty installation, unauthorized alteration, lack of maintenance, corrosive atmospheres, installation or removal costs and incidental or consequential damages.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912193249442,"sku":"LOGC44","price":472.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/LOGC44-WEB.jpg?v=1795047799"},{"product_id":"kingsman-hb36-designer-clean-view-circulating-kit-hb36cvck","title":"Kingsman HB36 Designer Clean View Circulating Kit HB36CVCK","description":"\u003cp\u003eThe HB36CVCK Designer Clean View Circulating Kit gives the 36\" Kingsman HBZDV3624 and HBZDV3628 a louver-free face while still circulating warm air. Each HBZDV36 needs either this kit or the HB36GBL grill kit.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean view look\u003c\/strong\u003e: designer front that hides the louvers for a cleaner face; replaces the grill kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired choice\u003c\/strong\u003e: each HBZDV36 needs either this kit or the HB36GBL grill kit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: HB36CVCK\u003c\/li\u003e\n\u003cli\u003eKingsman price list description: Designer Clean View Circulating Kit\u003c\/li\u003e\n\u003cli\u003eUnit with kit: 38 1\/16\" W x 34 11\/16\" H x 18 7\/8\" D; framing 38 7\/16\" x 41\" x 19 1\/2\"\u003c\/li\u003e\n\u003cli\u003eShipping weight: 18 lb\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-hbzdv3624-36-direct-vent-gas-fireplace-hbzdv3624\"\u003eKingsman HBZDV3624 fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Grill Kit or Designer Clean View Kit (Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-hbzdv3628-36-direct-vent-gas-fireplace-hbzdv3628\"\u003eKingsman HBZDV3628 fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Grill Kit or Designer Clean View Kit (Required for Each Unit))\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eClearances with the Clean View kit: 36HB-MAN19 p.14.\u003c\/li\u003e\n\u003cli\u003eInstallation should be done by a qualified installer following the appliance installation manual. United Fireplaces recommends that every appliance and accessory be installed by a qualified professional installer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/36HB-MAN19.pdf\"\u003eHBZDV3624 installation and operating manual (36HB-MAN19)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912193773730,"sku":"HB36CVCK","price":524.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/kingsman-hb36cvck-1.jpg?v=1795271564"},{"product_id":"kingsman-hb36-grill-kit-black-hb36gbl","title":"Kingsman HB36 Grill Kit, Black HB36GBL","description":"\u003cp\u003eThe HB36GBL black grill kit provides the traditional louvered face for the 36\" Kingsman HBZDV3624 and HBZDV3628. Each unit needs either this grill kit or the HB36CVCK Clean View kit.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTraditional louvers\u003c\/strong\u003e: black grill kit for the upper and lower louvers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired choice\u003c\/strong\u003e: each HBZDV36 needs this grill kit or the HB36CVCK\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: HB36GBL\u003c\/li\u003e\n\u003cli\u003eKingsman price list description: Grill Kit - Black\u003c\/li\u003e\n\u003cli\u003eFinish: black\u003c\/li\u003e\n\u003cli\u003eShipping weight: 4.5 lb\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-hbzdv3624-36-direct-vent-gas-fireplace-hbzdv3624\"\u003eKingsman HBZDV3624 fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Grill Kit or Designer Clean View Kit (Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-hbzdv3628-36-direct-vent-gas-fireplace-hbzdv3628\"\u003eKingsman HBZDV3628 fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Grill Kit or Designer Clean View Kit (Required for Each Unit))\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstall as shown in 36HB-MAN19.\u003c\/li\u003e\n\u003cli\u003eInstallation should be done by a qualified installer following the appliance installation manual. United Fireplaces recommends that every appliance and accessory be installed by a qualified professional installer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/36HB-MAN19.pdf\"\u003eHBZDV3624 installation and operating manual (36HB-MAN19)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912193806498,"sku":"HB36GBL","price":132.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/kingsman-black-grill-kit-for-hb3624hb3628-direct-vent-fireplace-1760727471_1997.jpg?v=1795048270"},{"product_id":"kingsman-hb42-designer-clean-view-circulating-kit-hb42cvck","title":"Kingsman HB42 Designer Clean View Circulating Kit HB42CVCK","description":"\u003cp\u003eThe HB42CVCK Designer Clean View Circulating Kit gives the 42\" Kingsman HBZDV4224 and HBZDV4228 a louver-free face while still circulating warm air. Each HBZDV42 needs either this kit or the HB42GBL grill kit.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean view look\u003c\/strong\u003e: designer front that hides the louvers for a cleaner face; replaces the grill kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired choice\u003c\/strong\u003e: each HBZDV42 needs either this kit or the HB42GBL grill kit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: HB42CVCK\u003c\/li\u003e\n\u003cli\u003eKingsman price list description: Designer Clean View Circulating Kit\u003c\/li\u003e\n\u003cli\u003eUnit with kit: 42 1\/16\" W x 36 13\/16\" H x 18 15\/16\" D; framing 42 7\/16\" x 43\" x 19 1\/2\"\u003c\/li\u003e\n\u003cli\u003eShipping weight: 20 lb\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-hbzdv4224-42-direct-vent-gas-fireplace-hbzdv4224\"\u003eKingsman HBZDV4224 fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Grill Kit or Designer Clean View Kit (Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-hbzdv4228-42-direct-vent-gas-fireplace-hbzdv4228\"\u003eKingsman HBZDV4228 fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Grill Kit or Designer Clean View Kit (Required for Each Unit))\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eClearances with the Clean View kit: see the 42HB-MAN19 manual.\u003c\/li\u003e\n\u003cli\u003eInstallation should be done by a qualified installer following the appliance installation manual. United Fireplaces recommends that every appliance and accessory be installed by a qualified professional installer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/42HB-MAN19.pdf\"\u003eHBZDV4224 installation and operating manual (42HB-MAN19)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912193839266,"sku":"HB42CVCK","price":575.98,"currency_code":"USD","in_stock":true}]},{"product_id":"kingsman-hb42-grill-kit-black-hb42gbl","title":"Kingsman HB42 Grill Kit, Black HB42GBL","description":"\u003cp\u003eThe HB42GBL black grill kit provides the traditional louvered face for the 42\" Kingsman HBZDV4224 and HBZDV4228. Each unit needs either this grill kit or the HB42CVCK Clean View kit.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTraditional louvers\u003c\/strong\u003e: black grill kit for the upper and lower louvers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired choice\u003c\/strong\u003e: each HBZDV42 needs this grill kit or the HB42CVCK\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: HB42GBL\u003c\/li\u003e\n\u003cli\u003eKingsman price list description: Grill Kit - Black\u003c\/li\u003e\n\u003cli\u003eFinish: black\u003c\/li\u003e\n\u003cli\u003eShipping weight: 5 lb\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-hbzdv4224-42-direct-vent-gas-fireplace-hbzdv4224\"\u003eKingsman HBZDV4224 fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Grill Kit or Designer Clean View Kit (Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-hbzdv4228-42-direct-vent-gas-fireplace-hbzdv4228\"\u003eKingsman HBZDV4228 fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Grill Kit or Designer Clean View Kit (Required for Each Unit))\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstall as shown in 42HB-MAN19.\u003c\/li\u003e\n\u003cli\u003eInstallation should be done by a qualified installer following the appliance installation manual. United Fireplaces recommends that every appliance and accessory be installed by a qualified professional installer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/42HB-MAN19.pdf\"\u003eHBZDV4224 installation and operating manual (42HB-MAN19)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912193872034,"sku":"HB42GBL","price":144.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/kingsman-black-grill-kit-for-hb3624hb3628-direct-vent-fireplace-1760727471_1997_0d3e9a57-d6cd-4007-8bcb-cbd7390bf3d6.jpg?v=1795048270"},{"product_id":"kingsman-fibre-split-oak-log-set-logf36","title":"Kingsman Fibre Split Oak Log Set LOGF36","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe LOGF36 is Kingsman's seven-piece fibre split oak log set for the HBZDV4736 47\" fireplace and the IDV44 fireplace insert. Its larger logs fill the wide firebox for a full, traditional fire.\u003c\/p\u003e\u003cp\u003eLogs 1 to 7 sit on the rear log holder and placement tabs, with glowing embers on the front of the burner and lava rock on the burner pan. With a brick liner it gives the look of a real masonry hearth.\u003c\/p\u003e\u003cp\u003eIt is the required log set for the HBZDV4736 and one of the media choices for the IDV44 (the other is the RSP10 glass platform).\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeven-piece fibre oak\u003c\/strong\u003e: seven ceramic-fibre logs with split-oak detail (36MQ-Man19 p.21, p.31)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTab-located placement\u003c\/strong\u003e: logs seat on the rear holder and placement tabs for a consistent layout\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlow ember kit\u003c\/strong\u003e: embers and lava rock finish the bed (34IDV-MAN19-4 p.31)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge-firebox set\u003c\/strong\u003e: sized for the 47\" HBZDV4736 and the IDV44 insert\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eLOGF36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKingsman description\u003c\/th\u003e\n\u003ctd\u003eLog Set - Fiber Split Oak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePieces\u003c\/th\u003e\n\u003ctd\u003e7 logs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eceramic fibre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eKingsman HBZDV4736, IDV44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e12 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompatible fireplaces\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-hbzdv4736-47-direct-vent-gas-fireplace-hbzdv4736\"\u003eKingsman HBZDV4736 fireplace\u003c\/a\u003e: required (Kingsman price list: Log Set (Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-idv44-direct-vent-gas-fireplace-insert-idv44\"\u003eKingsman IDV44 insert\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Log Set or Glass Support Platform (Required for Each Unit))\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eSeven-piece LOGF36 fibre split oak log set\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eA Kingsman HBZDV4736 fireplace or IDV44 insert\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHB47RLT \/ HB47RLH \/ HB47RRH brick or HB47PL porcelain liner (HBZDV4736)\u003c\/li\u003e\n\u003cli\u003eIDV36RLT \/ IDV36RLH brick or IDV36PRL porcelain liner (IDV44)\u003c\/li\u003e\n\u003cli\u003eVLBIT6 log bits\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/36MQ-Man19.pdf\"\u003eHBZDV4736 installation and operating manual (36MQ-Man19)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/34IDV-MAN19-4.pdf\"\u003eIDV44 installation and operating manual (34IDV-MAN19-4)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (36MQ-Man19, 34IDV-MAN19-4). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eUse only the media the appliance manual approves, in the quantities it lists. Parts not approved for the appliance can cause sooting, delayed ignition, property damage or injury.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eLog placement (36MQ-Man19 p.31; 34IDV-MAN19-4 p.31)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003ePlace log 1 on the rear log holder and centre it; log 2 to the left and log 3 to the right of log 1.\u003c\/li\u003e\n\u003cli\u003eSeat the two bottom holes of logs 4 and 5 on the left and right placement tabs; log 6 goes on the mounting tab of log 2 and log 7 on the tabs of log 5.\u003c\/li\u003e\n\u003cli\u003eGlowing embers go on the front of the burner tube and ember plates; lava rock on the burner pan only, never on the burner tube.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDoor and glass (36MQ-Man19 p.30)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eTempered glass is required for the HBZDV4736; replacement glass must be 5 mm and a substitute glass voids the warranty.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eUse, care and maintenance\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNever cover the pilot or the pilot-to-burner crossover. You should always be able to see the pilot when lighting; if you cannot, the log or media placement is wrong.\u003c\/li\u003e\n\u003cli\u003eIf sooting appears, turn the fireplace off, let it cool and reposition or remove the piece the flame is touching. Never alter the gas orifice.\u003c\/li\u003e\n\u003cli\u003eLogs, media and the glass get very hot. Only handle them when the fireplace is completely cool, and keep children and pets away from the glass.\u003c\/li\u003e\n\u003cli\u003eHave the logs, burner and pilot inspected and cleaned every year by a qualified service technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (36MQ-Man19 p.8; 34IDV-MAN19-4 p.8).\u003c\/li\u003e\n\u003cli\u003eAny fan or light kit wiring: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1\u003c\/a\u003e in Canada.\u003c\/li\u003e\n\u003cli\u003eManufactured-home installations follow the \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e where the appliance is approved for them.\u003c\/li\u003e\n\u003cli\u003eMassachusetts: a licensed plumber or gas fitter must install the appliance, and CO detectors are required (\u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe log set \/ media is a Kingsman component of the fireplace it is installed in. Kingsman prints its Limited Lifetime Warranty in each appliance manual (36MQ-Man19 p.76; 34IDV-MAN19-4 p.76).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and are done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for an appliance that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada, installed and operated following the manual and local codes. Keep your installation records; without them coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, misuse or negligence, faulty installation, unauthorized alteration, lack of maintenance, corrosive atmospheres, installation or removal costs and incidental or consequential damages.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912194396322,"sku":"LOGF36","price":590.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/LOGF36-Oak-Log-Set_86383478-237c-43b3-8f18-2892ee28d8d6.jpg?v=1795047799"},{"product_id":"kingsman-hb47-designer-clean-view-circulating-kit-hb47cvck","title":"Kingsman HB47 Designer Clean View Circulating Kit HB47CVCK","description":"\u003cp\u003eThe HB47CVCK Designer Clean View Circulating Kit gives the Kingsman HBZDV4736 a louver-free face that still circulates warm air. The HBZDV4736 needs either this kit or the HB47GBL grill kit.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean view look\u003c\/strong\u003e: designer front that hides the louvers; no grill is required with this kit (36MQ-Man19 p.21)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired choice\u003c\/strong\u003e: each HBZDV4736 needs either this kit or the HB47GBL grill kit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: HB47CVCK\u003c\/li\u003e\n\u003cli\u003eKingsman price list description: Designer Clean View Circulating Kit\u003c\/li\u003e\n\u003cli\u003eUnit with kit: 48 1\/16\" W x 49\" H x 21 15\/16\" D; framing 48 3\/8\" x 49 1\/8\" x 22\"\u003c\/li\u003e\n\u003cli\u003eShipping weight: 20 lb\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-hbzdv4736-47-direct-vent-gas-fireplace-hbzdv4736\"\u003eKingsman HBZDV4736 fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Grill Kit or Designer Clean View Kit (Required for Each Unit))\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eClean View kit installation: 36MQ-Man19 p.19.\u003c\/li\u003e\n\u003cli\u003eInstallation should be done by a qualified installer following the appliance installation manual. United Fireplaces recommends that every appliance and accessory be installed by a qualified professional installer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/36MQ-Man19.pdf\"\u003eHBZDV4736 installation and operating manual (36MQ-Man19)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912194429090,"sku":"HB47CVCK","price":647.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/kingsman-hb47cvck-1.jpg?v=1795271564"},{"product_id":"kingsman-hb47-grill-kit-black-hb47gbl","title":"Kingsman HB47 Grill Kit, Black HB47GBL","description":"\u003cp\u003eThe HB47GBL black grill kit provides the louvered face for the Kingsman HBZDV4736. The fireplace needs either this grill kit or the HB47CVCK Clean View kit.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTraditional louvers\u003c\/strong\u003e: black grill kit, used instead of the HB47CVCK (36MQ-Man19 p.21)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired choice\u003c\/strong\u003e: each HBZDV4736 needs this grill kit or the HB47CVCK\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: HB47GBL\u003c\/li\u003e\n\u003cli\u003eKingsman price list description: Grill Kit ‐ Black\u003c\/li\u003e\n\u003cli\u003eFinish: black\u003c\/li\u003e\n\u003cli\u003eShipping weight: 6 lb\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-hbzdv4736-47-direct-vent-gas-fireplace-hbzdv4736\"\u003eKingsman HBZDV4736 fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Grill Kit or Designer Clean View Kit (Required for Each Unit))\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstall as shown in 36MQ-Man19.\u003c\/li\u003e\n\u003cli\u003eInstallation should be done by a qualified installer following the appliance installation manual. United Fireplaces recommends that every appliance and accessory be installed by a qualified professional installer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2019\/03\/36MQ-Man19.pdf\"\u003eHBZDV4736 installation and operating manual (36MQ-Man19)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912194461858,"sku":"HB47GBL","price":169.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/kingsman-black-grill-kit-for-hb3624hb3628-direct-vent-fireplace-1760727471_1997_e8b18add-c669-49d9-9847-934f633723e8.jpg?v=1795048270"},{"product_id":"kingsman-five-piece-fibre-split-oak-log-set-logf3","title":"Kingsman Five-Piece Fibre Split Oak Log Set LOGF3","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe LOGF3 is Kingsman's five-piece fibre split oak log set for the ZCV39 and ZCV42 clean view fireplaces (and their H heater-rated versions). It gives these large clean-face fireplaces a classic, full log fire.\u003c\/p\u003e\u003cp\u003eLogs set against the back walls and on the burner log tabs, with embers, lava rock and insulation wool on the burner. With the stacked, traditional or herringbone brick liners it creates the masonry look shown in the photos.\u003c\/p\u003e\u003cp\u003eEach ZCV39 or ZCV42 needs one media choice: this log set, or a glass tray with glass media.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFive-piece fibre oak\u003c\/strong\u003e: five ceramic-fibre logs (39ZCV-MAN19-16 p.70)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTab placement\u003c\/strong\u003e: logs 3 and 4 sit on the burner log tabs, logs 1, 2 and 5 against the back walls\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo sizes\u003c\/strong\u003e: fits both the ZCV39 and ZCV42 (and H models)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiner friendly\u003c\/strong\u003e: pairs with ZCV39\/ZCV42 brick and porcelain liners\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eLOGF3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKingsman description\u003c\/th\u003e\n\u003ctd\u003eLog Set - Five Piece - Fiber Split Oak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePieces\u003c\/th\u003e\n\u003ctd\u003e5 logs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eceramic fibre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eZCV39, ZCV39H, ZCV42, ZCV42H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e7 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompatible fireplaces\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv39-clean-view-direct-vent-gas-fireplace-zcv39\"\u003eKingsman ZCV39 fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Log Set, Rock Set, or Glass Set (One Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv39h-heater-rated-clean-view-fireplace-zcv39h\"\u003eKingsman ZCV39H heater-rated fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Log Set, Rock Set, or Glass Set (One Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv42-clean-view-direct-vent-gas-fireplace-zcv42\"\u003eKingsman ZCV42 fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Log Set, Rock Set, Or Glass Set (One Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv42h-heater-rated-clean-view-fireplace-zcv42h\"\u003eKingsman ZCV42H heater-rated fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Log Set, Rock Set, or Glass Set (One Required for Each Unit))\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eFive-piece LOGF3 fibre split oak log set\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eA Kingsman ZCV39 or ZCV42 (embers, lava rock and wool per the manual)\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZCV39\/ZCV42 brick or porcelain liners\u003c\/li\u003e\n\u003cli\u003eZ46FK fan kit\u003c\/li\u003e\n\u003cli\u003eVLBIT6 log bits\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/39ZCV-MAN19-16.pdf\"\u003eZCV39 installation and operating manual (39ZCV-MAN19-16)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (39ZCV-MAN19-16). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.\u003c\/p\u003e\u003ch4\u003eProduct and safety information\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eUse only the media the appliance manual approves, in the quantities it lists. Parts not approved for the appliance can cause sooting, delayed ignition, property damage or injury.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eLog C3\/F3 placement (39ZCV-MAN19-16 p.70)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSet the primary air opening to 1\/8\" for natural gas.\u003c\/li\u003e\n\u003cli\u003eLogs 1 and 5 against the back walls, log 2 against the left back wall, logs 3 and 4 on the burner log tabs.\u003c\/li\u003e\n\u003cli\u003eSpread embers, lava rock and insulation wool as shown; keep the pilot clear.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eLiners (39ZCV-MAN19-16 pp.63-65)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eFit any brick or porcelain liner before the logs.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eUse, care and maintenance\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNever cover the pilot or the pilot-to-burner crossover. You should always be able to see the pilot when lighting; if you cannot, the log or media placement is wrong.\u003c\/li\u003e\n\u003cli\u003eIf sooting appears, turn the fireplace off, let it cool and reposition or remove the piece the flame is touching. Never alter the gas orifice.\u003c\/li\u003e\n\u003cli\u003eLogs, media and the glass get very hot. Only handle them when the fireplace is completely cool, and keep children and pets away from the glass.\u003c\/li\u003e\n\u003cli\u003eHave the logs, burner and pilot inspected and cleaned every year by a qualified service technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, or in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1\u003c\/a\u003e (39ZCV-MAN19-16 p.5-9).\u003c\/li\u003e\n\u003cli\u003eAny fan or light kit wiring: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1\u003c\/a\u003e in Canada.\u003c\/li\u003e\n\u003cli\u003eManufactured-home installations follow the \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, 24 CFR Part 3280\u003c\/a\u003e where the appliance is approved for them.\u003c\/li\u003e\n\u003cli\u003eMassachusetts: a licensed plumber or gas fitter must install the appliance, and CO detectors are required (\u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe log set \/ media is a Kingsman component of the fireplace it is installed in. Kingsman prints its Limited Lifetime Warranty in each appliance manual (39ZCV-MAN19-16 p.122).\u003c\/li\u003e\n\u003cli\u003eBasic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and are done by an authorized Kingsman dealer.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner, for an appliance that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada, installed and operated following the manual and local codes. Keep your installation records; without them coverage starts 30 days after the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eHow to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: accident, abuse, misuse or negligence, faulty installation, unauthorized alteration, lack of maintenance, corrosive atmospheres, installation or removal costs and incidental or consequential damages.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912194986146,"sku":"LOGF3","price":457.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/LOGF3-5-piece-Split-Oak-Log-Set.jpg?v=1795047800"},{"product_id":"kingsman-zcv39-glass-tray-zcv39gt","title":"Kingsman ZCV39 Glass Tray ZCV39GT","description":"\u003cp\u003eThe ZCV39GT glass tray converts the Kingsman ZCV39 or ZCV39H to a contemporary glass-media fire. It requires 15 lb of glass media (three 5 lb bags of Z5GC), sold separately; the ULK2 light kit can be added.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlass fire\u003c\/strong\u003e: holds decorative glass, cannonballs and other approved media in place of a log set\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKit\u003c\/strong\u003e: glass tray, pilot shield, glass retainer and 3 DT screws (39ZCV-MAN19-16 p.66)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: ZCV39GT\u003c\/li\u003e\n\u003cli\u003eKingsman price list description: Glass Tray for KFZCV39 - (Requires 15 lbs. of Glass Media)\u003c\/li\u003e\n\u003cli\u003eRequires: 15 lb glass media (3 x Z5GC)\u003c\/li\u003e\n\u003cli\u003eShipping weight: 8 lb\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv39-clean-view-direct-vent-gas-fireplace-zcv39\"\u003eKingsman ZCV39 fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Log Set, Rock Set, or Glass Set (One Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv39h-heater-rated-clean-view-fireplace-zcv39h\"\u003eKingsman ZCV39H heater-rated fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Log Set, Rock Set, or Glass Set (One Required for Each Unit))\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRequires 15 lb of glass media in the ZCV39 (price list; 39ZCV-MAN19-16 pp.75-77).\u003c\/li\u003e\n\u003cli\u003eDo not cover the pilot shield area with media and inspect the pilot shield monthly (p.66). RBCB1 cannonballs and the ULK2 light kit must be used with the glass tray (pp.67-68, 74).\u003c\/li\u003e\n\u003cli\u003eInstallation should be done by a qualified installer following the appliance installation manual. United Fireplaces recommends that every appliance and accessory be installed by a qualified professional installer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/39ZCV-MAN19-16.pdf\"\u003eZCV39 installation and operating manual (39ZCV-MAN19-16)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912195018914,"sku":"ZCV39GT","price":222.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/kingsman-zcv39gt-1.jpg?v=1795271565"},{"product_id":"kingsman-zcv42-glass-tray-zcv42gt","title":"Kingsman ZCV42 Glass Tray ZCV42GT","description":"\u003cp\u003eThe ZCV42GT glass tray converts the Kingsman ZCV42 or ZCV42H to a glass-media fire. It requires 20 lb of glass media (four 5 lb bags of Z5GC), sold separately; the ULK2 light kit can be added.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlass fire\u003c\/strong\u003e: holds decorative glass, cannonballs and other approved media in place of a log set\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKit\u003c\/strong\u003e: glass tray, pilot shield, glass retainer and 3 DT screws (39ZCV-MAN19-16 p.66)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: ZCV42GT\u003c\/li\u003e\n\u003cli\u003eKingsman price list description: Glass Tray for KFZCV42 - (Requires 20 lbs. of Glass Media)\u003c\/li\u003e\n\u003cli\u003eRequires: 20 lb glass media (4 x Z5GC)\u003c\/li\u003e\n\u003cli\u003eShipping weight: 8 lb\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv42-clean-view-direct-vent-gas-fireplace-zcv42\"\u003eKingsman ZCV42 fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Log Set, Rock Set, Or Glass Set (One Required for Each Unit))\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kingsman-zcv42h-heater-rated-clean-view-fireplace-zcv42h\"\u003eKingsman ZCV42H heater-rated fireplace\u003c\/a\u003e: one of the required media\/trim choices (Kingsman price list: Log Set, Rock Set, or Glass Set (One Required for Each Unit))\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRequires 20 lb of glass media in the ZCV42 (price list; 39ZCV-MAN19-16 pp.75-77).\u003c\/li\u003e\n\u003cli\u003eDo not cover the pilot shield area with media and inspect the pilot shield monthly (p.66). RBCB1 cannonballs and the ULK2 light kit must be used with the glass tray (pp.67-68, 74).\u003c\/li\u003e\n\u003cli\u003eInstallation should be done by a qualified installer following the appliance installation manual. United Fireplaces recommends that every appliance and accessory be installed by a qualified professional installer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/kingsmanind.com\/wp-content\/uploads\/2016\/07\/39ZCV-MAN19-16.pdf\"\u003eZCV42 installation and operating manual (39ZCV-MAN19-16)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":50912195051682,"sku":"ZCV42GT","price":233.05,"currency_code":"USD","in_stock":true}]}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/collections\/ZCVRB47-60-WEB-1_0881dfae-bed4-4a82-a218-f1042e1aadde.jpg?v=1795234889","url":"https:\/\/unitedfireplaces.com\/collections\/kingsman.oembed?page=3","provider":"United Fireplaces","version":"1.0","type":"link"}