{"title":"Best Sellers","description":"\u003cp\u003eThe fireplaces, stoves and inserts our customers buy again and again. Every one is picked by our hearth team for reliability, value and easy installation. Not sure which fits your home? Call (844) 545-7995 and talk to a real hearth expert.\u003c\/p\u003e","products":[{"product_id":"breckwell-blazer-pellet-stove-insert-sp24i","title":"Breckwell Blazer Pellet Stove Insert SP24I","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Breckwell SP24I Blazer is a pellet stove insert that turns an existing fireplace into an automatic pellet heater. Breckwell rates it for up to 50,000 BTUs and up to 2,200 sq. ft. It is approved for masonry fireplaces, listed factory-built (UL 127) fireplaces and standard residential built-ins, including in mobile homes.\u003c\/p\u003e\u003cp\u003eThe body is 29-1\/2\" wide at the fireplace opening, 22\" wide at the rear and 21\" high, and sits 16-3\/8\" deep in the fireplace. A medium (28\" x 44-1\/2\") or large (32\" x 48-1\/2\") flashing finishes the face, and the optional SA24IBK brick panel set dresses the firebox.\u003c\/p\u003e\u003cp\u003eA 60 lb. hopper feeds a removable stainless steel burn pot, lit by the Hot Rod igniter, with five heat settings on a one-touch digital control board. It is certified to the 2020 EPA particulate standard at 0.66 g\/h and 77% efficiency, with a tested output of 5,993 to 22,587 Btu\/h, and vents through 3\" or 4\" listed PL vent. It suits homeowners who want steady pellet heat from a fireplace they already have.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 50,000 BTUs: Providing comforting heat up to 2200 sq. ft. 5 heat settings.\u003c\/li\u003e\n\u003cli\u003eThe automatic fuel feed lets you burn up to 70 hours on each load with the 60 lb. hopper fuel capacity.\u003c\/li\u003e\n\u003cli\u003eHeavy steel construction provides long-term reliability and durability.\u003c\/li\u003e\n\u003cli\u003eOne touch digital technology control board with multiple safety checks and diagnostics; extends the life and efficiency of your stove.\u003c\/li\u003e\n\u003cli\u003eThe Hot Rod Automatic Fire Starter igniter ensures the stove lights quickly and safely. No messy starter gels needed.\u003c\/li\u003e\n\u003cli\u003eStainless steel burn pot. Removable for easy cleaning.\u003c\/li\u003e\n\u003cli\u003eSpecial air wash system helps keep glass clean.\u003c\/li\u003e\n\u003cli\u003eUp to 70 hours burn time.\u003c\/li\u003e\n\u003cli\u003eMobile Home Approved\u003c\/li\u003e\n\u003cli\u003eCertified to the 2020 EPA particulate standard: 0.66 g\/h, 77% efficiency, tested output 5,993 to 22,587 Btu\/h\u003c\/li\u003e\n\u003cli\u003eApproved for masonry fireplaces, listed factory-built (UL 127) fireplaces and standard residential built-ins\u003c\/li\u003e\n\u003cli\u003eRear horizontal exhaust that can be turned to vertical exhaust\u003c\/li\u003e\n\u003cli\u003eVents with 3\" or 4\" listed PL vent; Class A chimney not required\u003c\/li\u003e\n\u003cli\u003eOptional SA24IBK brick panel set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eSpecifications \u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 93.4662%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e29-1\/2\" W at the fireplace opening (22\" W at the rear) x 21\" H x 23-1\/2\" D overall (16-3\/8\" D in the fireplace). Flashing: medium 28\" x 44-1\/2\" or large 32\" x 48-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum fireplace opening\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer. The insert body needs room for 29-1\/2\" W at the opening, 22\" W at the rear, 21\" H and 16-3\/8\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eCombustible side wall 5\". Side facing 3\". Top facing 10\". Mantel 14\" minimum; where the mantel projects more than 6\" from the fireplace face, 15\" from the stove top to the bottom of the mantel. Floor protection: non-combustible floor protector rated R1 over a combustible floor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 64.4662%;\"\u003e250 lbs (insert); 13 lbs (flashing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003eHeating Capacity\u003c\/td\u003e\n\u003ctd style=\"width: 64.4662%;\"\u003e2,200 sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003eHopper Capacity\u003c\/td\u003e\n\u003ctd style=\"width: 64.4662%;\"\u003e60 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003eBurn Time\u003c\/td\u003e\n\u003ctd style=\"width: 64.4662%;\"\u003eup to 70 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003eBTUs\u003c\/td\u003e\n\u003ctd style=\"width: 64.4662%;\"\u003e50,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eListed Type PL vent, 3\" or 4\" diameter; Class A chimney not required\u003c\/li\u003e\n\u003cli\u003eVent extended to the top of the chimney: required in mobile homes and zero-clearance fireplaces, recommended in all fireplaces\u003c\/li\u003e\n\u003cli\u003eOne liner kit (choose length and diameter):\u003cul\u003e\n\u003cli\u003eDuraVent 3\" BestFlex SS Pellet Stove 20' Liner Kit L320IK-R6\u003c\/li\u003e\n\u003cli\u003eDuraVent 3\" BestFlex SS Pellet Stove 25' Liner Kit L325IK-R6\u003c\/li\u003e\n\u003cli\u003eDuraVent 3\" BestFlex SS Pellet Stove 35' Liner Kit L335IK-R6\u003c\/li\u003e\n\u003cli\u003eDuraVent 4\" BestFlex SS Pellet Stove 25' Liner Kit L425IK-R6\u003c\/li\u003e\n\u003cli\u003eDuraVent 4\" BestFlex SS Pellet Stove 35' Liner Kit L435IK-R6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eNon-combustible floor protector rated R1 over a combustible floor\u003c\/li\u003e\n\u003cli\u003eA 120V, 60 Hz grounded outlet and a power surge protector\u003c\/li\u003e\n\u003cli\u003eMobile homes only: a combustion air intake\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSA24IBK brick panel set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003e\u003ca style=\"color: #ff0000;\" title=\"Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/2129\/3073\/files\/854234---SP24iE_EN_FR.pdf?v=1769094517\" target=\"_blank\" rel=\"noopener\"\u003eOwners Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003e\u003ca style=\"color: #ff0000;\" title=\"Warranty\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/2129\/3073\/files\/Warranty.pdf?v=1769094502\" target=\"_blank\" rel=\"noopener\"\u003eWarranty\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects, and\/or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — SP24I\u003c\/h3\u003e\n\u003ch4\u003eWhat kind of fireplace can the SP24I go in?\u003c\/h4\u003e\u003cp\u003eA masonry fireplace, a listed factory-built (UL 127) fireplace or a standard residential built-in, including in a mobile home. The insert body is 29-1\/2\" wide at the opening, 22\" wide at the rear and 21\" high, and sits 16-3\/8\" deep in the fireplace.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use?\u003c\/h4\u003e\u003cp\u003eListed Type PL vent, 3\" or 4\" in diameter; a Class A chimney is not required. The vent must run to the top of the chimney in mobile homes and zero-clearance fireplaces, and Breckwell recommends it in all fireplaces. It must not share a flue with another appliance, and no flue damper may be fitted.\u003c\/p\u003e\n\u003ch4\u003eHow high must the mantel be?\u003c\/h4\u003e\u003cp\u003eAt least 14\". Where the mantel projects more than 6\" from the fireplace face, keep 15\" from the stove top to the bottom of the mantel. Keep 10\" to the top facing, 3\" to the side facing and 5\" to a combustible side wall.\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eNo. The SP24I will not run during a power outage. It plugs into a 120V, 60 Hz grounded outlet, and Breckwell requires a power surge protector.\u003c\/p\u003e\n\u003ch4\u003eHow much does it heat, and how big is the hopper?\u003c\/h4\u003e\u003cp\u003eBreckwell rates it for up to 50,000 BTUs and up to 2,200 sq. ft., with five heat settings. The hopper holds 60 lbs. of pellets, for up to 70 hours of burn time.\u003c\/p\u003e\n\u003ch4\u003eWhat's the warranty?\u003c\/h4\u003e\u003cp\u003eBreckwell limited lifetime warranty: lifetime on the firebox and heat exchanger, 3 years on the door and firepot, and 1 year on cabinets and trim, gaskets, ceramic glass and all electrical parts (blowers, auger motor, control board and switches).\u003c\/p\u003e","brand":"Breckwell","offers":[{"title":"Default Title","offer_id":50589531078818,"sku":"SP24I","price":3399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Breckwell-Blazer-Pellet-Stove-Insert-SP24I_6322__22567.1785133431.1280.1280.jpg?v=1792482817"},{"product_id":"monessen-48-artisan-vent-free-linear-fireplace-avfl48","title":"Monessen Artisan 48\" Vent-Free Gas Fireplace AVFL48","description":"\u003ch3\u003eIgnition \u0026amp; Controls\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eIntelliFire Touch 2.0 (electronic) — included.\u003c\/strong\u003e IntelliFire Touch 2.0 is the electronic ignition system supplied with this fireplace. Choose the correct fuel configuration; ignition is included rather than a separate add-on.\u003c\/p\u003e\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Monessen Artisan 48 (AVFL48) is a single-sided, vent-free linear gas fireplace and one of four single-sided Artisan widths (42, 48, 60 and 72 in.). It needs no chimney or vent pipe, and as a zero-clearance unit it can sit against, or be recessed into, any wall a gas line can reach, which suits remodels, condos and new builds.\u003c\/p\u003e\u003cp\u003eA 48\" x 17\" ribbon of flame rises through Diamond crushed fireglass, and black reflective glass panels multiply the flame picture. Multicolor LED hearth lighting glows in one color or cycles through colors, with or without the flame. Input is 39,000 BTU\/h on natural gas or 38,000 BTU\/h on propane, and Monessen rates it at 99.9% efficiency because the heat stays in the room. It is supplemental heat, not a primary heating system.\u003c\/p\u003e\u003cp\u003eIntelliFire Touch intermittent pilot ignition and the included IFT2-RC450 touchscreen remote handle flame height, lights, thermostat and timer, and battery backup keeps the fire running in a power outage. Finish it clean-face, or with the AVFL48TKI trim kit or a Veined Copper or Satin Black face, then swap the glass for Bronze, Onyx or Sapphire, or add the CDLS driftwood log set or STONEKIT.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVent-free, zero-clearance\u003c\/strong\u003e: no chimney or vent pipe; installs against or recessed into any wall with gas access, and can be finished clean-face with non-combustible materials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e99.9% efficiency\u003c\/strong\u003e: virtually all of the heat produced stays in the room (Monessen rating).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 39,000 BTU\/h natural gas \/ 38,000 BTU\/h propane maximum; 27,500 \/ 31,000 BTU\/h minimum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelliFire Touch ignition\u003c\/strong\u003e: intermittent pilot lights only when the fire is called for, and the system turns the fire off after nine hours of continuous operation without a command.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTouchscreen remote included\u003c\/strong\u003e: the IFT2-RC450 controls on\/off, flame height, lights, thermostat mode, timer and child lock, and shows room temperature; an optional Wi-Fi module adds IntelliFire app control and Amazon Alexa and Google Assistant voice control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery backup\u003c\/strong\u003e: four AA batteries (not included) keep the fire running during a power outage; lights and other 120 V functions do not run on battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulticolor LED hearth lighting\u003c\/strong\u003e: a high-contrast glow in a chosen color, or continuously cycling colors, with or without the flame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReflective panels and fireglass\u003c\/strong\u003e: black reflective glass interior panels multiply the flame, over 4 bags of included Diamond crushed glass laid in a single layer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory fuel models\u003c\/strong\u003e: natural gas (AVFL48NIF) or propane (AVFL48PIF); field conversion is not permitted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified\u003c\/strong\u003e: listed to ANSI Z21.11.2 for unvented room heaters.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eAVFL48NIF (natural gas) \/ AVFL48PIF (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eVent-free (unvented) linear gas fireplace, single-sided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e52-1\/8\" W x 39-1\/2\" H x 13-3\/8\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003e52-5\/8\" W x 39-3\/4\" H x 13-1\/8\" D (13-3\/4\" D with finishing Option 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e48\" W x 17\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eSides: 6\" minimum from the inside of the appliance to a combustible side wall; back: may sit against a combustible wall; ceiling: 36\" minimum from the appliance opening; front: 36\" to curtains, furniture and other combustibles; floor: may sit on wood, plywood or particle board, not on carpet, vinyl, tile or soft coverings, with a 14\" minimum hearth extension recommended where vinyl flooring runs to the wall; mantel: 22\" (combustible) or 20\" (non-combustible) minimum above the top of the appliance opening; TV: 28\" minimum TV height (manufacturer TV guideline, which does not cover every TV's temperature limit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAppliance weight\u003c\/th\u003e\n\u003ctd\u003e220 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum input\u003c\/th\u003e\n\u003ctd\u003e39,000 BTU\/h natural gas \/ 38,000 BTU\/h propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum input (BTU\/h)\u003c\/th\u003e\n\u003ctd\u003e27,500 NG \/ 31,000 LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e99.9% (Monessen rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eIntelliFire Touch intermittent pilot (IPI) with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003eUnswitched 110–120 VAC, 60 Hz to the junction box; 6 VDC control system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. NPT; manual shutoff inside the valve compartment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMedia included\u003c\/th\u003e\n\u003ctd\u003e4 bags Diamond crushed glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eANSI Z21.11.2 (unvented room heaters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with burner, IntelliFire Touch control system and safety screen\u003c\/li\u003e\n\u003cli\u003e7-1\/4 in. non-combustible facing board (must be installed)\u003c\/li\u003e\n\u003cli\u003eDeflector glass\u003c\/li\u003e\n\u003cli\u003e4 bags Diamond crushed-glass media\u003c\/li\u003e\n\u003cli\u003eTwo anchoring screws\u003c\/li\u003e\n\u003cli\u003eIntelliFire touchscreen remote (IFT2-RC450)\u003c\/li\u003e\n\u003cli\u003eMulticolor LED hearth lighting\u003c\/li\u003e\n\u003cli\u003eBlack reflective glass interior panels\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe correct factory fuel model: natural gas (NIF) or propane (PIF); field conversion is not permitted\u003c\/li\u003e\n\u003cli\u003eGas supply line with a listed manual shutoff valve (1\/2 in. NPT connection)\u003c\/li\u003e\n\u003cli\u003eExternal regulator on propane installations (supply no more than 13 in. w.c.)\u003c\/li\u003e\n\u003cli\u003eUnswitched 110–120 VAC, 60 Hz circuit to the junction box (GFCI where required)\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for battery backup (not included)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAVFL48TKI Satin Black inside-fit trim kit\u003c\/li\u003e\n\u003cli\u003eAVFL48CFVC Contemporary Veined Copper face\u003c\/li\u003e\n\u003cli\u003eAVFL48CFSB Contemporary Satin Black face\u003c\/li\u003e\n\u003cli\u003eCDLS contemporary driftwood log set (do not combine with stones)\u003c\/li\u003e\n\u003cli\u003eSTONEKIT decorative stone kit (do not combine with logs)\u003c\/li\u003e\n\u003cli\u003eReplacement or alternate fireglass: Diamond, Bronze, Onyx or Sapphire\u003c\/li\u003e\n\u003cli\u003eWi-Fi module for IntelliFire app and voice control\u003c\/li\u003e\n\u003cli\u003eWired wall switch with battery backup port, or wireless wall switch\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/4099_903_AVFL42-AVFL48-AVFL60_INSTALL.pdf\"\u003eArtisan series installation manual (4099-903 Rev D), covers AVFL42\/48\/60\/72 and AVFLST48\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/4099_902_AVFL42-AVFL48-AVFL60_OWNER.pdf\"\u003eArtisan series owner manual (4099-902 Rev G), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/brochures\/MON-1001U_ArtisanSeries.pdf\"\u003eArtisan series brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/brochures\/MON-1025_VentFreeGas_FP_ProductGuide.pdf\"\u003eMonessen vent-free gas fireplace product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003ePlease read before you buy:\u003c\/strong\u003e this is a gas appliance. If it is not installed, adjusted, operated and maintained exactly as the manufacturer describes, it can cause a fire or explosion, or produce carbon monoxide. Monessen requires installation and service by a qualified installer, service agency or the gas supplier (Artisan installation manual 4099-903 Rev D, cover and p.4). If you ever smell gas, do not try to light any appliance, do not use electrical switches or phones in the building, leave the building and call your gas supplier from a neighbor's phone.\u003c\/p\u003e\u003ch4\u003eProduct specific and safety information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eListed to ANSI Z21.11.2 for unvented room heaters; intended as supplemental or decorative heat, not a primary heat source (p.4).\u003c\/li\u003e\n\u003cli\u003eInput is rated at 0–2,000 ft. Above 2,000 ft, reduce input 4% for each 1,000 ft (pp.4, 8, 25).\u003c\/li\u003e\n\u003cli\u003eDo not install in a bedroom or bathroom. In Massachusetts, installation must be done by a licensed plumber or gas fitter (pp.1, 7).\u003c\/li\u003e\n\u003cli\u003eMay be installed in a permanently located manufactured (mobile) home where local codes allow (p.1).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGetting started: location and combustion air\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eThe room (plus any rooms connected by openings without doors) must provide at least 50 cubic feet of volume per 1,000 BTU\/h of total gas input; smaller \"confined\" spaces need additional ventilation air (p.6).\u003c\/li\u003e\n\u003cli\u003eKeep curtains, furniture, clothing and other combustibles at least 36 in. from the front of the fireplace, and avoid high-traffic, windy or drafty spots (p.6).\u003c\/li\u003e\n\u003cli\u003eZero-clearance unit: it may be installed against, or recessed into, any wall where a gas line can be run (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFraming and clearances\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFloor: may sit on wood, plywood or particle board, not directly on carpet, vinyl, tile or soft coverings. With vinyl flooring, a 14 in. minimum hearth extension is recommended (pp.16, 20).\u003c\/li\u003e\n\u003cli\u003eChase: insulate chase walls and ceiling; seal gaps and firestops with caulk rated for 300°F continuous exposure (p.20).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas: inlet 5.0–10.0 in. w.c. (7.0 recommended); manifold 3.5 in. w.c. (p.24).\u003c\/li\u003e\n\u003cli\u003ePropane: inlet 11.0–13.0 in. w.c. (12.0 recommended); manifold 10 in. w.c.; an external regulator is required (pp.4, 24).\u003c\/li\u003e\n\u003cli\u003ePressures above 1\/2 PSIG (14 in. w.c.) damage the valve; disconnect the appliance before pressure-testing the line (p.24).\u003c\/li\u003e\n\u003cli\u003eThe gas supply must match the rating plate. Field conversion between natural gas and propane is not permitted (pp.5, 23).\u003c\/li\u003e\n\u003cli\u003eGas line enters on the left side or right bottom through a 1\/2 in. NPT connection (pp.24–25).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eElectrical information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eRequires an unswitched 110–120 VAC, 60 Hz supply to the junction box; never wire 110–120 VAC to the valve or the wall switch (pp.26–27).\u003c\/li\u003e\n\u003cli\u003eGFCI protection is required where codes call for it, such as near sinks (p.4).\u003c\/li\u003e\n\u003cli\u003eBattery backup (four AA) is for emergency use only; lights and other 120 V functions do not run on battery (pp.27, 39).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinal installation: glass, media and logs\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall the deflection glass before any media; spread the crushed glass in a single layer only. Too much media restricts air and can cause sooting (p.30).\u003c\/li\u003e\n\u003cli\u003eUse only the CDLS driftwood logs or STONEKIT; logs and stones cannot be combined, and nothing else may be added to the firebox (pp.30–34).\u003c\/li\u003e\n\u003cli\u003eAny screen or guard removed for service must be replaced before operating (owner manual p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinishing\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eThe non-combustible board must be installed and may not be covered with drywall or other combustible material (p.36).\u003c\/li\u003e\n\u003cli\u003eSurrounding finishes must withstand 190°F; sealants must be rated for at least 300°F; finish thickness 1\/4 in. to 1 in. (pp.14–15, 36).\u003c\/li\u003e\n\u003cli\u003eUse 100% acrylic latex paint in eggshell, semi-gloss or gloss; flat paint is not recommended (pp.36–37).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: run on the highest setting for three to four hours with windows open; a temporary odor is normal (p.8).\u003c\/li\u003e\n\u003cli\u003eGlass and surrounding surfaces get hot. Supervise children and pets, and keep remotes out of reach (owner manual p.7).\u003c\/li\u003e\n\u003cli\u003eLearn the signs of carbon monoxide exposure (headache, dizziness, nausea); if they appear, get fresh air and have the heater serviced (p.8).\u003c\/li\u003e\n\u003cli\u003eHave the fireplace inspected annually by a qualified service technician (p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNFPA 54 \/ ANSI Z223.1 National Fuel Gas Code\u003c\/a\u003e (pp.4, 8).\u003c\/li\u003e\n\u003cli\u003eIn Canada: \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1 Natural Gas and Propane Installation Code\u003c\/a\u003e (Canada) and \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (Canada) (p.4).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Hearth \u0026amp; Home Technologies (HHT) Limited Lifetime Warranty, form 4021-645N (12\/23), printed in the Artisan series owner manual (4099-902 Rev G), pp.4–5. Monessen is an HHT brand.\u003c\/li\u003e\n\u003cli\u003eAll parts and material, including handles and external enameled components: 1 year parts and labor (subject to the warranty conditions and exclusions).\u003c\/li\u003e\n\u003cli\u003eElectrical components (modules, remotes and wall switches, valves, pilots, blowers, junction boxes, wire harnesses, transformers and lights, excluding bulbs): 2 years.\u003c\/li\u003e\n\u003cli\u003eCement refractory panels and glass liner panels: 2 years.\u003c\/li\u003e\n\u003cli\u003eVented and vent-free burners and logs: 5 years.\u003c\/li\u003e\n\u003cli\u003eBurners, logs and metal\/fiber refractory components of HHT-manufactured fireplaces: 10 years parts, 1 year labor.\u003c\/li\u003e\n\u003cli\u003eFirebox and heat exchanger: 20 years parts, 3 years labor.\u003c\/li\u003e\n\u003cli\u003ePurchased replacement parts and optional accessories: 1 year parts, no labor.\u003c\/li\u003e\n\u003cli\u003eWho is covered: products bought from an HHT authorized dealer or distributor. Coverage transfers to later owners while the product stays at its original installation site, but the period is not extended. Valid only in the country where the selling dealer is authorized.\u003c\/li\u003e\n\u003cli\u003eWhen coverage starts: on the date of installation (new construction: six months after the final sale invoice, and no later than 24 months after HHT ships the product).\u003c\/li\u003e\n\u003cli\u003eHow service works: warranty service is arranged through the installing dealer or distributor. Travel and parts-shipping charges are not covered.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: normal wear items (paint, gaskets, firebricks, grates, flame guides, batteries, glass discoloration), normal finish color changes and cosmetic damage, noise from normal expansion and contraction, and damage from improper installation, operation or maintenance, code violations, inadequate ventilation, unauthorized modifications or a fuel other than the one specified. HHT does not guarantee heating capacity for a given space.\u003c\/li\u003e\n\u003cli\u003eThe warranty is void if the product is over-fired, operated in a chemically contaminated atmosphere, or damaged by prolonged dampness, condensation or water.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — AVFL48\u003c\/h3\u003e\n\u003ch4\u003eWhat size framing does the AVFL48 need?\u003c\/h4\u003e\u003cp\u003eThe framed opening is 52-5\/8\" W × 39-3\/4\" H × 13-1\/8\" D, or 13-3\/4\" D when finishing with Option 2. The back may sit against a combustible wall; keep 6\" from the inside of the appliance to a combustible side wall and 36\" from the opening to the ceiling. The 7-1\/4\" non-combustible facing board supplied must be installed.\u003c\/p\u003e\n\u003ch4\u003eDoes it need a chimney or vent?\u003c\/h4\u003e\u003cp\u003eNo. It is a vent-free fireplace listed to ANSI Z21.11.2 for unvented room heaters. The room, plus any rooms joined to it by openings without doors, must provide at least 50 cubic feet per 1,000 BTU\/h of total gas input, which is 1,950 cubic feet for this fireplace alone at its maximum input. It may not be installed in a bedroom or bathroom.\u003c\/p\u003e\n\u003ch4\u003eCan it be converted between natural gas and propane?\u003c\/h4\u003e\u003cp\u003eNo. Natural gas (AVFL48NIF) and propane (AVFL48PIF) are separate factory models, and field conversion is not permitted, so order the model that matches your gas supply. Propane installations need an external regulator.\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Four AA batteries (not included) in the battery backup let the remote turn the fire on and off when the power is out. The LED lights and other 120 V functions do not run on battery, and the backup is for emergency use, not as a long-term power source.\u003c\/p\u003e\n\u003ch4\u003eIs a remote included?\u003c\/h4\u003e\u003cp\u003eYes. The IFT2-RC450 touchscreen remote ships with it and controls on\/off, flame height, lights, thermostat, timer and child lock. An optional Wi-Fi module adds IntelliFire app control and Amazon Alexa and Google Assistant voice control.\u003c\/p\u003e\n\u003ch4\u003eCan a TV go above it, and how high must the mantel be?\u003c\/h4\u003e\u003cp\u003eYes. A combustible mantel must be at least 22\" above the top of the appliance opening and a non-combustible mantel at least 20\". Monessen's TV guideline gives a 28\" minimum TV height. Surrounding finishes must withstand 190°F.\u003c\/p\u003e","brand":"Monessen","offers":[{"title":"Natural Gas","offer_id":50592560840866,"sku":"AVFL48NIF","price":4219.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50592560873634,"sku":"AVFL48PIF","price":4219.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/monessen-avfl48ni-1.jpg?v=1791653243"},{"product_id":"monessen-36-lo-rider-see-through-vent-free-firebox-lstf36-b","title":"Monessen 36\" Lo-Rider See-Through Vent-Free Firebox LSTF36-B","description":"\u003ch3\u003eIgnition \u0026amp; Controls\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eIgnition depends on the burner.\u003c\/strong\u003e This is a firebox enclosure. Fuel type, ignition and compatible controls are determined by the separately selected, approved burner and log set.\u003c\/p\u003e\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Monessen Lo-Rider See-Through 36 (LSTF36-B) is a vent-free, see-through firebox that brings the flush-hearth, tall-opening Lo-Rider look to two rooms at once. A 36 x 30-3\/4 in. viewing area on each side shares one fire between spaces.\u003c\/p\u003e\u003cp\u003eFactory-installed traditional concrete refractory panels give it a classic masonry look, and the clean-face front keeps the view open on both sides.\u003c\/p\u003e\u003cp\u003eIt is a firebox only: pair it with a listed see-through vent-free gas log set up to 40,000 BTU\/h, such as the Natural Blaze see-through system. Options include the BLOTDL forced air kit, the MONALST accent light kit and the AK22 combustion air kit.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSee-through design\u003c\/strong\u003e: viewable from both sides, 36 x 30-3\/4 in. each side.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlush-hearth, tall opening\u003c\/strong\u003e: the Lo-Rider wood-fire look.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTraditional concrete refractory panels\u003c\/strong\u003e: factory installed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean-face circulating front\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor listed unvented see-through log sets up to 40,000 BTU\/h\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional BLOTDL forced air kit\u003c\/strong\u003e and MONALST accent light kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAK22 combustion air kit\u003c\/strong\u003e with ID4 or UD4 duct (optional).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo canopies included\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified\u003c\/strong\u003e: CSA\/ANSI Z21.91-2020 ventless firebox enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLSTF36-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eVent-free see-through firebox, firebox only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e36 x 30-3\/4 in. each side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e46 x 37-1\/2 x 23 in. (brochure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum hearth\u003c\/th\u003e\n\u003ctd\u003e33-1\/2 in. wide, 27-3\/4 in. high, 19 in. deep (manual p.12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e185 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum log set input\u003c\/th\u003e\n\u003ctd\u003e40,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.91-2020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVent-free see-through firebox\u003c\/li\u003e\n\u003cli\u003eTwo canopies\u003c\/li\u003e\n\u003cli\u003eFactory-installed traditional concrete refractory panels\u003c\/li\u003e\n\u003cli\u003eInstallation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eA listed see-through vent-free gas log set with burner, 40,000 BTU\/h maximum (sold separately)\u003c\/li\u003e\n\u003cli\u003eGas supply with listed shutoff; external regulator for propane (13 in. w.c. max)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBLOTDL forced air kit\u003c\/li\u003e\n\u003cli\u003eMONALST accent light kit\u003c\/li\u003e\n\u003cli\u003eAK22 combustion air kit with ID4 or UD4 duct\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/LSTF36-B_Installation_Manual_4613-900.pdf\"\u003eLo-Rider See-Through LSTF36-B installation and operating manual (4613-900 Rev I), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/serviceParts\/LSTF36-B.pdf\"\u003eLo-Rider (LSTF36-B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/brochures\/MON-1005U_Broc_VF_Fireboxes.pdf\"\u003eVent Free Fireboxes\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/architectGuides\/MON_Lo-Rider_ST_LSTF36_Firebox_Architect_Guide.pdf\"\u003eLo-Rider ST LSTF36\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003ePlease read before you buy:\u003c\/strong\u003e this is a gas appliance. If it is not installed, adjusted, operated and maintained exactly as the manufacturer describes, it can cause a fire or explosion, or produce carbon monoxide. Monessen requires installation and service by a qualified installer, service agency or the gas supplier (Lo-Rider LSTF36-B installation manual 4613-900 Rev I, p.1). If you ever smell gas, do not try to light any appliance, do not use electrical switches or phones in the building, leave the building and call your gas supplier from a neighbor's phone.\u003c\/p\u003e\u003ch4\u003eImportant safety and operating information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eComplies with CSA\/ANSI Z21.91-2020; use only with a listed unvented heater not exceeding 40,000 BTU\/h (pp.1, 7).\u003c\/li\u003e\n\u003cli\u003eNot for a bathroom; bedroom installations are limited to heaters of 10,000 BTU\/h or less (p.7). Supplemental zone heat only (p.7).\u003c\/li\u003e\n\u003cli\u003eDo not build a wood fire or overfire; overfiring voids the warranty (p.1). Above 2,000 ft reduce input 4% per 1,000 ft (p.8). Never connect to a private gas well (p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eClearances\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSidewall at least 6 in. from the inside of the appliance; ceiling at least 42 in. from the top of the opening; a parallel wall at least 36 in. from the opening (p.13).\u003c\/li\u003e\n\u003cli\u003eMantel clearances for combustible and non-combustible material are shown in Figures 6.3–6.4 (p.13).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHearth and floor\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMinimum hearth 33-1\/2 x 27-3\/4 x 19 in. (p.12).\u003c\/li\u003e\n\u003cli\u003eInstall at least 1 in. above combustible flooring closer than 14 in. to the base, or use 14 in. of non-combustible material; with vinyl, a 14 in. hearth extension is recommended (p.14).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas connections and combustion air\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003ePropane requires an external regulator (13 in. w.c. maximum); natural gas must be regulated to 10.5 in. w.c. maximum (p.16).\u003c\/li\u003e\n\u003cli\u003eThe screen must have openings for combustion air unless other provisions exist; close the screen before operating (pp.8, 15).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eElectrical\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eField-wire main power only for models with the fan or accent light kit, by a qualified, licensed electrician (pp.10, 19).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eFinishing\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eNon-combustible finish must not extend past or interfere with the opening, and the black-painted face may not be overlaid with combustible material (p.14).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNFPA 54 \/ ANSI Z223.1 National Fuel Gas Code\u003c\/a\u003e (p.8).\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Hearth \u0026amp; Home Technologies (HHT) Limited Lifetime Warranty, form 4021-645N (12\/23), printed in the LSTF36-B installation manual (4613-900 Rev I), pp.5–6. Monessen is an HHT brand.\u003c\/li\u003e\n\u003cli\u003eAll parts and material, including handles and external enameled components: 1 year parts and labor (subject to the warranty conditions and exclusions).\u003c\/li\u003e\n\u003cli\u003eElectrical components (modules, remotes and wall switches, valves, pilots, blowers, junction boxes, wire harnesses, transformers and lights, excluding bulbs): 2 years.\u003c\/li\u003e\n\u003cli\u003eCement refractory panels and glass liner panels: 2 years.\u003c\/li\u003e\n\u003cli\u003eVented and vent-free burners and logs: 5 years.\u003c\/li\u003e\n\u003cli\u003eBurners, logs and metal\/fiber refractory components of HHT-manufactured fireplaces: 10 years parts, 1 year labor.\u003c\/li\u003e\n\u003cli\u003eFirebox and heat exchanger: 20 years parts, 3 years labor.\u003c\/li\u003e\n\u003cli\u003ePurchased replacement parts and optional accessories: 1 year parts, no labor.\u003c\/li\u003e\n\u003cli\u003eWho is covered: products bought from an HHT authorized dealer or distributor. Coverage transfers to later owners while the product stays at its original installation site, but the period is not extended. Valid only in the country where the selling dealer is authorized.\u003c\/li\u003e\n\u003cli\u003eWhen coverage starts: on the date of installation (new construction: six months after the final sale invoice, and no later than 24 months after HHT ships the product).\u003c\/li\u003e\n\u003cli\u003eHow service works: warranty service is arranged through the installing dealer or distributor. Travel and parts-shipping charges are not covered.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: normal wear items (paint, gaskets, firebricks, grates, flame guides, batteries, glass discoloration), normal finish color changes and cosmetic damage, noise from normal expansion and contraction, and damage from improper installation, operation or maintenance, code violations, inadequate ventilation, unauthorized modifications or a fuel other than the one specified. HHT does not guarantee heating capacity for a given space.\u003c\/li\u003e\n\u003cli\u003eThe warranty is void if the product is over-fired, operated in a chemically contaminated atmosphere, or damaged by prolonged dampness, condensation or water.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e","brand":"Monessen","offers":[{"title":"Default Title","offer_id":50592561266850,"sku":"LSTF36-B","price":1919.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/monessen-lstf36-b-3.jpg?v=1791817415"},{"product_id":"monessen-42-artisan-vent-free-linear-fireplace-avfl42","title":"Monessen Artisan 42\" Vent-Free Gas Fireplace AVFL42","description":"\u003ch3\u003eIgnition \u0026amp; Controls\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eIntelliFire Touch 2.0 (electronic) — included.\u003c\/strong\u003e IntelliFire Touch 2.0 is the electronic ignition system supplied with this fireplace. Choose the correct fuel configuration; ignition is included rather than a separate add-on.\u003c\/p\u003e\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Monessen Artisan 42 (AVFL42) is a single-sided, vent-free linear gas fireplace for homeowners who want a modern focal point without the cost and disruption of a chimney or vent pipe. It is built as a zero-clearance unit that can sit against, or be recessed into, any wall a gas line can reach, which makes it a strong choice for remodels, condos and new builds alike.\u003c\/p\u003e\u003cp\u003eThe look is clean and contemporary: a long, uninterrupted flame rises through shimmering Diamond fireglass. On the 42-inch model, the black reflective glass liner (AVFL42BGL) and multicolor LED hearth lighting (IFT2-AVFL42LED) are available as add-ons, so you can build it up to match the larger Artisan sizes.\u003c\/p\u003e\u003cp\u003eMonessen rates the Artisan at 99.9% efficiency, because a vent-free fireplace keeps its heat in the room. This model delivers Standard output (BU): 34,000 BTU\/h natural gas \/ 33,000 BTU\/h propane. Reduced output (RB): 24,500 \/ 24,000 BTU\/h. It is designed as supplemental heat for the room it is in, not as a primary heating system.\u003c\/p\u003e\u003cp\u003eControl is handled by the IntelliFire Touch intermittent pilot ignition system, so there is no standing pilot burning when the fire is off. Remote and wall controls, including the IntelliFire touchscreen remote, are optional on the 42-inch model, and battery backup lets the fire run during a power outage. An optional Wi-Fi module adds IntelliFire app control and works with Amazon Alexa and Google Assistant.\u003c\/p\u003e\u003cp\u003eFinish it your way: install it clean-face with the included non-combustible board, or add a Satin Black inside-fit trim kit or a Contemporary Veined Copper or Satin Black face. Swap the standard Diamond glass for Bronze, Onyx or Sapphire, or choose the optional driftwood log set or stone kit for a different look.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVent-free operation\u003c\/strong\u003e: no chimney or vent pipe is needed, which keeps installation simpler and lets the unit go on almost any wall with gas access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e99.9% efficiency\u003c\/strong\u003e: virtually all of the heat produced stays in the room (Monessen rating).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: Standard output (BU): 34,000 BTU\/h natural gas \/ 33,000 BTU\/h propane. Reduced output (RB): 24,500 \/ 24,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelliFire Touch ignition\u003c\/strong\u003e: intermittent pilot ignition lights the pilot only when the fire is called for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote ready\u003c\/strong\u003e: add the IntelliFire touchscreen remote, a wired wall switch or a wireless wall switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery backup\u003c\/strong\u003e: four AA batteries (not included) keep the fire running during a power outage; lights and other 120 V functions do not run on battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED lighting option\u003c\/strong\u003e: the IFT2-AVFL42LED kit adds multicolor hearth lighting to the 42-inch model.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlack glass liner option\u003c\/strong\u003e: the AVFL42BGL kit adds the reflective black glass interior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiamond fireglass\u003c\/strong\u003e: 4 bags of crushed glass media are included, installed in a single layer over the burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWi-Fi ready\u003c\/strong\u003e: the optional Wi-Fi module adds IntelliFire app control, remote monitoring and voice control with Amazon Alexa and Google Assistant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean-face design\u003c\/strong\u003e: finish right up to the opening with non-combustible materials, or add a trim kit or decorative face.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety shutdown\u003c\/strong\u003e: the system turns the fire off after nine hours of continuous operation without a command.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNatural gas or propane\u003c\/strong\u003e: built as separate factory fuel models; field conversion is not permitted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified\u003c\/strong\u003e: listed to ANSI Z21.11.2 for unvented room heaters.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eAVFL42NIF-BU, AVFL42PIF-BU, AVFL42NIF-RB, AVFL42PIF-RB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eVent-free (unvented) linear gas fireplace, single-sided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e46-1\/8 in. W x 40-1\/4 in. H x 13-3\/8 in. D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eFlat wall: 46-5\/8 in. W x 39-3\/4 in. H x 13-1\/8 in. D (13-3\/4 in. D with finishing Option 2). Corner: 47-7\/8 in. along each wall, 71-1\/4 in. across the front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e42 x 17 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eBack: 0 in. (may sit against a combustible back wall). Sides: 6 in. from the inside edge of the appliance to a combustible side wall. Ceiling: 36 in. from the appliance opening. Floor: may sit on a combustible floor or raised platform (not on carpet, vinyl, tile or soft coverings). Front: 36 in. to curtains, furniture and other combustibles. Mantel (12 in. deep, above the opening): combustible 22 in. (BU); non-combustible 20 in. (BU). RB mantel: 14 in. (manual TV-guideline table, pp.18–19) \/ 18 in. combustible, 16 in. non-combustible for a 12 in. mantel (manual mantel drawings, pp.16–17)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAppliance weight\u003c\/th\u003e\n\u003ctd\u003e195 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum input\u003c\/th\u003e\n\u003ctd\u003eStandard output (BU): 34,000 BTU\/h natural gas \/ 33,000 BTU\/h propane. Reduced output (RB): 24,500 \/ 24,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum input (BTU\/h)\u003c\/th\u003e\n\u003ctd\u003eBU: 23,500 NG \/ 26,000 LP; RB: 17,500 NG \/ 19,000 LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e99.9% (Monessen rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eIntelliFire Touch intermittent pilot (IPI) with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003eUnswitched 110–120 VAC, 60 Hz to the junction box; 6 VDC control system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. NPT; manual shutoff inside the valve compartment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMedia included\u003c\/th\u003e\n\u003ctd\u003e4 bags Diamond crushed glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eANSI Z21.11.2 (unvented room heaters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with burner, IntelliFire Touch control system and safety screen\u003c\/li\u003e\n\u003cli\u003e7-1\/4 in. non-combustible facing board (must be installed)\u003c\/li\u003e\n\u003cli\u003eDeflector glass\u003c\/li\u003e\n\u003cli\u003e4 bags Diamond crushed-glass media\u003c\/li\u003e\n\u003cli\u003eTwo anchoring screws\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe correct factory fuel model: natural gas (NIF) or propane (PIF); field conversion is not permitted\u003c\/li\u003e\n\u003cli\u003eGas supply line with a listed manual shutoff valve (1\/2 in. NPT connection)\u003c\/li\u003e\n\u003cli\u003eExternal regulator on propane installations (supply no more than 13 in. w.c.)\u003c\/li\u003e\n\u003cli\u003eUnswitched 110–120 VAC, 60 Hz circuit to the junction box (GFCI where required)\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for battery backup (not included)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIFT2-AVFL42LED multicolor LED light kit\u003c\/li\u003e\n\u003cli\u003eAVFL42BGL black reflective glass liner kit\u003c\/li\u003e\n\u003cli\u003eIntelliFire touchscreen remote (IFT2-RC450)\u003c\/li\u003e\n\u003cli\u003eAVFL42TKI-B Satin Black inside-fit trim kit\u003c\/li\u003e\n\u003cli\u003eAVFL42CFVC Contemporary Veined Copper face\u003c\/li\u003e\n\u003cli\u003eAVFL42CFSB Contemporary Satin Black face\u003c\/li\u003e\n\u003cli\u003eCDLS contemporary driftwood log set (do not combine with stones)\u003c\/li\u003e\n\u003cli\u003eSTONEKIT decorative stone kit (do not combine with logs)\u003c\/li\u003e\n\u003cli\u003eReplacement or alternate fireglass: Diamond, Bronze, Onyx or Sapphire\u003c\/li\u003e\n\u003cli\u003eWi-Fi module for IntelliFire app and voice control\u003c\/li\u003e\n\u003cli\u003eWired wall switch with battery backup port, or wireless wall switch\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/4099_903_AVFL42-AVFL48-AVFL60_INSTALL.pdf\"\u003eArtisan series installation manual (4099-903 Rev D), covers AVFL42\/48\/60\/72 and AVFLST48\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/4099_902_AVFL42-AVFL48-AVFL60_OWNER.pdf\"\u003eArtisan series owner manual (4099-902 Rev G), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/brochures\/MON-1001U_ArtisanSeries.pdf\"\u003eArtisan series brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/brochures\/MON-1025_VentFreeGas_FP_ProductGuide.pdf\"\u003eMonessen vent-free gas fireplace product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003ePlease read before you buy:\u003c\/strong\u003e this is a gas appliance. If it is not installed, adjusted, operated and maintained exactly as the manufacturer describes, it can cause a fire or explosion, or produce carbon monoxide. Monessen requires installation and service by a qualified installer, service agency or the gas supplier (Artisan installation manual 4099-903 Rev D, cover and p.4). If you ever smell gas, do not try to light any appliance, do not use electrical switches or phones in the building, leave the building and call your gas supplier from a neighbor's phone.\u003c\/p\u003e\u003ch4\u003eProduct specific and safety information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eListed to ANSI Z21.11.2 for unvented room heaters; intended as supplemental or decorative heat, not a primary heat source (p.4).\u003c\/li\u003e\n\u003cli\u003eInput is rated at 0–2,000 ft. Above 2,000 ft, reduce input 4% for each 1,000 ft; confirm orifice sizing with your gas utility (pp.4, 8, 25).\u003c\/li\u003e\n\u003cli\u003eDo not install in a bedroom or bathroom. In Massachusetts, installation must be done by a licensed plumber or gas fitter (pp.1, 7).\u003c\/li\u003e\n\u003cli\u003eMay be installed in a permanently located manufactured (mobile) home where local codes allow (p.1).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGetting started: location and combustion air\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eThe room (plus any rooms connected by openings without doors) must provide at least 50 cubic feet of volume per 1,000 BTU\/h of total gas input; smaller \"confined\" spaces need additional ventilation air (p.6).\u003c\/li\u003e\n\u003cli\u003eKeep curtains, furniture, clothing and other combustibles at least 36 in. from the front of the fireplace, and avoid high-traffic, windy or drafty spots (p.6).\u003c\/li\u003e\n\u003cli\u003eZero-clearance unit: it may be installed against, or recessed into, any wall where a gas line can be run (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFraming and clearances\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSidewall: at least 6 in. from the inside edge of the appliance to any combustible side wall (p.16).\u003c\/li\u003e\n\u003cli\u003eCeiling: at least 36 in. from the appliance opening (p.16). The back of the unit may sit against a combustible wall (p.16).\u003c\/li\u003e\n\u003cli\u003eMantel \/ TV good-faith guidance: Combustible mantel 22 in. (BU); non-combustible mantel 20 in. (BU). RB mantel: 14 in. (manual TV-guideline table, pp.18–19) \/ 18 in. combustible, 16 in. non-combustible for a 12 in. mantel (manual mantel drawings, pp.16–17). Minimum TV height 28 in. (BU) or 18 in. (RB) (pp.18–19). TV temperatures must be confirmed at installation against the TV maker's limits.\u003c\/li\u003e\n\u003cli\u003eFloor: may sit on wood, plywood or particle board, not directly on carpet, vinyl, tile or soft coverings. With vinyl flooring, a 14 in. minimum hearth extension is recommended (pp.16, 20).\u003c\/li\u003e\n\u003cli\u003eChase: insulate chase walls and ceiling; seal gaps and firestops with caulk rated for 300°F continuous exposure (p.20).\u003c\/li\u003e\n\u003cli\u003eFraming: 46-5\/8 in. wide x 39-3\/4 in. high; appliance weight 195 lb (pp.10–13).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas: inlet 5.0–10.0 in. w.c. (7.0 recommended); manifold 3.5 in. w.c. (p.24).\u003c\/li\u003e\n\u003cli\u003ePropane: inlet 11.0–13.0 in. w.c. (12.0 recommended); manifold 10 in. w.c.; an external regulator is required (pp.4, 24).\u003c\/li\u003e\n\u003cli\u003ePressures above 1\/2 PSIG (14 in. w.c.) damage the valve; disconnect the appliance before pressure-testing the line (p.24).\u003c\/li\u003e\n\u003cli\u003eThe gas supply must match the rating plate. Field conversion between natural gas and propane is not permitted (pp.5, 23).\u003c\/li\u003e\n\u003cli\u003eGas line enters on the left side or right bottom through a 1\/2 in. NPT connection (pp.24–25).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eElectrical information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eRequires an unswitched 110–120 VAC, 60 Hz supply to the junction box; never wire 110–120 VAC to the valve or the wall switch (pp.26–27).\u003c\/li\u003e\n\u003cli\u003eGFCI protection is required where codes call for it, such as near sinks (p.4).\u003c\/li\u003e\n\u003cli\u003eBattery backup (four AA) is for emergency use only; lights and other 120 V functions do not run on battery (pp.27, 39).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinal installation: glass, media and logs\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall the deflection glass before any media; spread the crushed glass in a single layer only. Too much media restricts air and can cause sooting (p.30).\u003c\/li\u003e\n\u003cli\u003eUse only the CDLS driftwood logs or STONEKIT; logs and stones cannot be combined, and nothing else may be added to the firebox (pp.30–34).\u003c\/li\u003e\n\u003cli\u003eAny screen or guard removed for service must be replaced before operating (owner manual p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinishing\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eThe non-combustible board must be installed and may not be covered with drywall or other combustible material (p.36).\u003c\/li\u003e\n\u003cli\u003eSurrounding finishes must withstand 190°F; sealants must be rated for at least 300°F; finish thickness 1\/4 in. to 1 in. (pp.14–15, 36).\u003c\/li\u003e\n\u003cli\u003eUse 100% acrylic latex paint in eggshell, semi-gloss or gloss; flat paint is not recommended (pp.36–37).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: run on the highest setting for three to four hours with windows open; a temporary odor is normal (p.8).\u003c\/li\u003e\n\u003cli\u003eGlass and surrounding surfaces get hot. Supervise children and pets, and keep remotes out of reach (owner manual p.7).\u003c\/li\u003e\n\u003cli\u003eLearn the signs of carbon monoxide exposure (headache, dizziness, nausea); if they appear, get fresh air and have the heater serviced (p.8).\u003c\/li\u003e\n\u003cli\u003eHave the fireplace inspected annually by a qualified service technician (p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNFPA 54 \/ ANSI Z223.1 National Fuel Gas Code\u003c\/a\u003e (pp.4, 8).\u003c\/li\u003e\n\u003cli\u003eIn Canada: \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1 Natural Gas and Propane Installation Code\u003c\/a\u003e (Canada) and \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (Canada) (p.4).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Hearth \u0026amp; Home Technologies (HHT) Limited Lifetime Warranty, form 4021-645N (12\/23), printed in the Artisan series owner manual (4099-902 Rev G), pp.4–5. Monessen is an HHT brand.\u003c\/li\u003e\n\u003cli\u003eAll parts and material, including handles and external enameled components: 1 year parts and labor (subject to the warranty conditions and exclusions).\u003c\/li\u003e\n\u003cli\u003eElectrical components (modules, remotes and wall switches, valves, pilots, blowers, junction boxes, wire harnesses, transformers and lights, excluding bulbs): 2 years.\u003c\/li\u003e\n\u003cli\u003eCement refractory panels and glass liner panels: 2 years.\u003c\/li\u003e\n\u003cli\u003eVented and vent-free burners and logs: 5 years.\u003c\/li\u003e\n\u003cli\u003eBurners, logs and metal\/fiber refractory components of HHT-manufactured fireplaces: 10 years parts, 1 year labor.\u003c\/li\u003e\n\u003cli\u003eFirebox and heat exchanger: 20 years parts, 3 years labor.\u003c\/li\u003e\n\u003cli\u003ePurchased replacement parts and optional accessories: 1 year parts, no labor.\u003c\/li\u003e\n\u003cli\u003eWho is covered: products bought from an HHT authorized dealer or distributor. Coverage transfers to later owners while the product stays at its original installation site, but the period is not extended. Valid only in the country where the selling dealer is authorized.\u003c\/li\u003e\n\u003cli\u003eWhen coverage starts: on the date of installation (new construction: six months after the final sale invoice, and no later than 24 months after HHT ships the product).\u003c\/li\u003e\n\u003cli\u003eHow service works: warranty service is arranged through the installing dealer or distributor. Travel and parts-shipping charges are not covered.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: normal wear items (paint, gaskets, firebricks, grates, flame guides, batteries, glass discoloration), normal finish color changes and cosmetic damage, noise from normal expansion and contraction, and damage from improper installation, operation or maintenance, code violations, inadequate ventilation, unauthorized modifications or a fuel other than the one specified. HHT does not guarantee heating capacity for a given space.\u003c\/li\u003e\n\u003cli\u003eThe warranty is void if the product is over-fired, operated in a chemically contaminated atmosphere, or damaged by prolonged dampness, condensation or water.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — AVFL42\u003c\/h3\u003e\u003ch4\u003eWhat size framing does the AVFL42 need?\u003c\/h4\u003e\u003cp\u003eFor a flat wall, frame an opening 46-5\/8 in. wide x 39-3\/4 in. high x 13-1\/8 in. deep, or 13-3\/4 in. deep if you finish with Option 2. For a corner, the framing runs 47-7\/8 in. along each wall and 71-1\/4 in. across the front. The fireplace weighs 195 lb.\u003c\/p\u003e\u003ch4\u003eDoes it need a chimney or vent pipe?\u003c\/h4\u003e\u003cp\u003eNo. The Artisan is vent-free, so it needs no chimney or vent pipe and can go against, or be recessed into, any wall a gas line can reach. The room (plus rooms open to it without doors) must have at least 50 cubic feet of volume per 1,000 BTU\/h of input, and it may not be installed in a bedroom or bathroom.\u003c\/p\u003e\u003ch4\u003eCan it be converted between natural gas and propane?\u003c\/h4\u003e\u003cp\u003eNo. Field conversion is not permitted. Order the natural gas model (NIF) or the propane model (PIF) to match your supply; propane installations also need an external regulator.\u003c\/p\u003e\u003ch4\u003eIs a remote included, and does it work in a power outage?\u003c\/h4\u003e\u003cp\u003eA remote is not included; the IntelliFire touchscreen remote (IFT2-RC450), a wired wall switch or a wireless wall switch are optional. The IntelliFire Touch system has battery backup on four AA batteries (not included), so the fire runs in a power outage; the lights and other 120 V functions do not.\u003c\/p\u003e\u003ch4\u003eHow high must a mantel or TV be?\u003c\/h4\u003e\u003cp\u003eWith a 12 in. deep mantel above the opening, a combustible mantel needs 22 in. (BU) and a non-combustible mantel 20 in. (BU). For the RB models the manual gives two figures: 14 in. in its TV-guideline table (pp.18–19), and 18 in. combustible or 16 in. non-combustible for a 12 in. mantel in its mantel drawings (pp.16–17). The ceiling must be at least 36 in. above the opening. Monessen's good-faith TV guideline gives a minimum TV height of 28 in. (BU) or 18 in. (RB).\u003c\/p\u003e\u003ch4\u003eWhat is the warranty?\u003c\/h4\u003e\u003cp\u003eIt is covered by the Hearth \u0026amp; Home Technologies Limited Lifetime Warranty: 1 year parts and labor on all parts, 2 years on electrical components, and 20 years parts with 3 years labor on the firebox and heat exchanger.\u003c\/p\u003e","brand":"Monessen","offers":[{"title":"Propane \/ Standard Output (BU)","offer_id":50592565526690,"sku":"AVFL42PIF-BU","price":2979.0,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Reduced Output (RB)","offer_id":50592565559458,"sku":"AVFL42PIF-RB","price":2969.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ Standard Output (BU)","offer_id":50592565592226,"sku":"AVFL42NIF-BU","price":2969.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ Reduced Output (RB)","offer_id":50592565624994,"sku":"AVFL42NIF-RB","price":2979.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/monessen-avfl42-1.jpg?v=1791653953"},{"product_id":"monessen-60-artisan-vent-free-linear-fireplace-avfl60","title":"Monessen Artisan 60\" Vent-Free Gas Fireplace AVFL60","description":"\u003ch3\u003eIgnition \u0026amp; Controls\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eIntelliFire Touch 2.0 (electronic) — included.\u003c\/strong\u003e IntelliFire Touch 2.0 is the electronic ignition system supplied with this fireplace. Choose the correct fuel configuration; ignition is included rather than a separate add-on.\u003c\/p\u003e\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Monessen Artisan 60 (AVFL60) is a single-sided, vent-free linear gas fireplace and one of four single-sided Artisan widths (42, 48, 60 and 72 in.). It needs no chimney or vent pipe, and as a zero-clearance unit it can sit against, or be recessed into, any wall a gas line can reach, which suits remodels, condos and new builds.\u003c\/p\u003e\u003cp\u003eA 60\" x 17\" ribbon of flame rises through Diamond crushed fireglass, and black reflective glass panels multiply the flame picture. Multicolor LED hearth lighting glows in one color or cycles through colors, with or without the flame. Input is 40,000 BTU\/h on natural gas or 39,000 BTU\/h on propane, and Monessen rates it at 99.9% efficiency because the heat stays in the room. It is supplemental heat, not a primary heating system.\u003c\/p\u003e\u003cp\u003eIntelliFire Touch intermittent pilot ignition and the included IFT2-RC450 touchscreen remote handle flame height, lights, thermostat and timer, and battery backup keeps the fire running in a power outage. Finish it clean-face, or with the AVFL60TKI-B trim kit or a Veined Copper or Satin Black face, then swap the glass for Bronze, Onyx or Sapphire, or add the CDLS driftwood log set or STONEKIT.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVent-free, zero-clearance\u003c\/strong\u003e: no chimney or vent pipe; installs against or recessed into any wall with gas access, and can be finished clean-face with non-combustible materials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e99.9% efficiency\u003c\/strong\u003e: virtually all of the heat produced stays in the room (Monessen rating).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat output\u003c\/strong\u003e: 40,000 BTU\/h natural gas \/ 39,000 BTU\/h propane maximum; 28,000 \/ 30,500 BTU\/h minimum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelliFire Touch ignition\u003c\/strong\u003e: intermittent pilot lights only when the fire is called for, and the system turns the fire off after nine hours of continuous operation without a command.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTouchscreen remote included\u003c\/strong\u003e: the IFT2-RC450 controls on\/off, flame height, lights, thermostat mode, timer and child lock, and shows room temperature; an optional Wi-Fi module adds IntelliFire app control and Amazon Alexa and Google Assistant voice control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery backup\u003c\/strong\u003e: four AA batteries (not included) keep the fire running during a power outage; lights and other 120 V functions do not run on battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulticolor LED hearth lighting\u003c\/strong\u003e: a high-contrast glow in a chosen color, or continuously cycling colors, with or without the flame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReflective panels and fireglass\u003c\/strong\u003e: black reflective glass interior panels multiply the flame, over 5 bags of included Diamond crushed glass laid in a single layer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory fuel models\u003c\/strong\u003e: natural gas (AVFL60NIF) or propane (AVFL60PIF); field conversion is not permitted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified\u003c\/strong\u003e: listed to ANSI Z21.11.2 for unvented room heaters.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eAVFL60NIF (natural gas) \/ AVFL60PIF (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eVent-free (unvented) linear gas fireplace, single-sided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e64-1\/8\" W x 39-1\/2\" H x 13-3\/8\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003e64-5\/8\" W x 39-3\/4\" H x 13-1\/8\" D (13-3\/4\" D with finishing Option 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e60\" W x 17\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eSides: 6\" minimum from the inside of the appliance to a combustible side wall; back: may sit against a combustible wall; ceiling: 36\" minimum from the appliance opening; front: 36\" to curtains, furniture and other combustibles; floor: may sit on wood, plywood or particle board, not on carpet, vinyl, tile or soft coverings, with a 14\" minimum hearth extension recommended where vinyl flooring runs to the wall; mantel: 22\" (combustible) or 20\" (non-combustible) minimum above the top of the appliance opening; TV: 28\" minimum TV height (manufacturer TV guideline, which does not cover every TV's temperature limit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAppliance weight\u003c\/th\u003e\n\u003ctd\u003e250 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum input\u003c\/th\u003e\n\u003ctd\u003e40,000 BTU\/h natural gas \/ 39,000 BTU\/h propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum input (BTU\/h)\u003c\/th\u003e\n\u003ctd\u003e28,000 NG \/ 30,500 LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e99.9% (Monessen rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eIntelliFire Touch intermittent pilot (IPI) with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003eUnswitched 110–120 VAC, 60 Hz to the junction box; 6 VDC control system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. NPT; manual shutoff inside the valve compartment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMedia included\u003c\/th\u003e\n\u003ctd\u003e5 bags Diamond crushed glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eANSI Z21.11.2 (unvented room heaters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with burner, IntelliFire Touch control system and safety screen\u003c\/li\u003e\n\u003cli\u003e7-1\/4 in. non-combustible facing board (must be installed)\u003c\/li\u003e\n\u003cli\u003eDeflector glass\u003c\/li\u003e\n\u003cli\u003e5 bags Diamond crushed-glass media\u003c\/li\u003e\n\u003cli\u003eTwo anchoring screws\u003c\/li\u003e\n\u003cli\u003eIntelliFire touchscreen remote (IFT2-RC450)\u003c\/li\u003e\n\u003cli\u003eMulticolor LED hearth lighting\u003c\/li\u003e\n\u003cli\u003eBlack reflective glass interior panels\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe correct factory fuel model: natural gas (NIF) or propane (PIF); field conversion is not permitted\u003c\/li\u003e\n\u003cli\u003eGas supply line with a listed manual shutoff valve (1\/2 in. NPT connection)\u003c\/li\u003e\n\u003cli\u003eExternal regulator on propane installations (supply no more than 13 in. w.c.)\u003c\/li\u003e\n\u003cli\u003eUnswitched 110–120 VAC, 60 Hz circuit to the junction box (GFCI where required)\u003c\/li\u003e\n\u003cli\u003eFour AA batteries for battery backup (not included)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAVFL60TKI-B Satin Black inside-fit trim kit\u003c\/li\u003e\n\u003cli\u003eAVFL60CFVC-B Contemporary Veined Copper face\u003c\/li\u003e\n\u003cli\u003eAVFL60CFSB Contemporary Satin Black face\u003c\/li\u003e\n\u003cli\u003eCDLS contemporary driftwood log set (do not combine with stones)\u003c\/li\u003e\n\u003cli\u003eSTONEKIT decorative stone kit (do not combine with logs)\u003c\/li\u003e\n\u003cli\u003eReplacement or alternate fireglass: Diamond, Bronze, Onyx or Sapphire\u003c\/li\u003e\n\u003cli\u003eWi-Fi module for IntelliFire app and voice control\u003c\/li\u003e\n\u003cli\u003eWired wall switch with battery backup port, or wireless wall switch\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/4099_903_AVFL42-AVFL48-AVFL60_INSTALL.pdf\"\u003eArtisan series installation manual (4099-903 Rev D), covers AVFL42\/48\/60\/72 and AVFLST48\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/4099_902_AVFL42-AVFL48-AVFL60_OWNER.pdf\"\u003eArtisan series owner manual (4099-902 Rev G), includes the warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/brochures\/MON-1001U_ArtisanSeries.pdf\"\u003eArtisan series brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/brochures\/MON-1025_VentFreeGas_FP_ProductGuide.pdf\"\u003eMonessen vent-free gas fireplace product guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003ePlease read before you buy:\u003c\/strong\u003e this is a gas appliance. If it is not installed, adjusted, operated and maintained exactly as the manufacturer describes, it can cause a fire or explosion, or produce carbon monoxide. Monessen requires installation and service by a qualified installer, service agency or the gas supplier (Artisan installation manual 4099-903 Rev D, cover and p.4). If you ever smell gas, do not try to light any appliance, do not use electrical switches or phones in the building, leave the building and call your gas supplier from a neighbor's phone.\u003c\/p\u003e\u003ch4\u003eProduct specific and safety information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eListed to ANSI Z21.11.2 for unvented room heaters; intended as supplemental or decorative heat, not a primary heat source (p.4).\u003c\/li\u003e\n\u003cli\u003eInput is rated at 0–2,000 ft. Above 2,000 ft, reduce input 4% for each 1,000 ft (pp.4, 8, 25).\u003c\/li\u003e\n\u003cli\u003eDo not install in a bedroom or bathroom. In Massachusetts, installation must be done by a licensed plumber or gas fitter (pp.1, 7).\u003c\/li\u003e\n\u003cli\u003eMay be installed in a permanently located manufactured (mobile) home where local codes allow (p.1).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGetting started: location and combustion air\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eThe room (plus any rooms connected by openings without doors) must provide at least 50 cubic feet of volume per 1,000 BTU\/h of total gas input; smaller \"confined\" spaces need additional ventilation air (p.6).\u003c\/li\u003e\n\u003cli\u003eKeep curtains, furniture, clothing and other combustibles at least 36 in. from the front of the fireplace, and avoid high-traffic, windy or drafty spots (p.6).\u003c\/li\u003e\n\u003cli\u003eZero-clearance unit: it may be installed against, or recessed into, any wall where a gas line can be run (p.7).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFraming and clearances\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFloor: may sit on wood, plywood or particle board, not directly on carpet, vinyl, tile or soft coverings. With vinyl flooring, a 14 in. minimum hearth extension is recommended (pp.16, 20).\u003c\/li\u003e\n\u003cli\u003eChase: insulate chase walls and ceiling; seal gaps and firestops with caulk rated for 300°F continuous exposure (p.20).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas: inlet 5.0–10.0 in. w.c. (7.0 recommended); manifold 3.5 in. w.c. (p.24).\u003c\/li\u003e\n\u003cli\u003ePropane: inlet 11.0–13.0 in. w.c. (12.0 recommended); manifold 10 in. w.c.; an external regulator is required (pp.4, 24).\u003c\/li\u003e\n\u003cli\u003ePressures above 1\/2 PSIG (14 in. w.c.) damage the valve; disconnect the appliance before pressure-testing the line (p.24).\u003c\/li\u003e\n\u003cli\u003eThe gas supply must match the rating plate. Field conversion between natural gas and propane is not permitted (pp.5, 23).\u003c\/li\u003e\n\u003cli\u003eGas line enters on the left side or right bottom through a 1\/2 in. NPT connection (pp.24–25).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eElectrical information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eRequires an unswitched 110–120 VAC, 60 Hz supply to the junction box; never wire 110–120 VAC to the valve or the wall switch (pp.26–27).\u003c\/li\u003e\n\u003cli\u003eGFCI protection is required where codes call for it, such as near sinks (p.4).\u003c\/li\u003e\n\u003cli\u003eBattery backup (four AA) is for emergency use only; lights and other 120 V functions do not run on battery (pp.27, 39).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinal installation: glass, media and logs\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall the deflection glass before any media; spread the crushed glass in a single layer only. Too much media restricts air and can cause sooting (p.30).\u003c\/li\u003e\n\u003cli\u003eUse only the CDLS driftwood logs or STONEKIT; logs and stones cannot be combined, and nothing else may be added to the firebox (pp.30–34).\u003c\/li\u003e\n\u003cli\u003eAny screen or guard removed for service must be replaced before operating (owner manual p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinishing\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eThe non-combustible board must be installed and may not be covered with drywall or other combustible material (p.36).\u003c\/li\u003e\n\u003cli\u003eSurrounding finishes must withstand 190°F; sealants must be rated for at least 300°F; finish thickness 1\/4 in. to 1 in. (pp.14–15, 36).\u003c\/li\u003e\n\u003cli\u003eUse 100% acrylic latex paint in eggshell, semi-gloss or gloss; flat paint is not recommended (pp.36–37).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire and everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: run on the highest setting for three to four hours with windows open; a temporary odor is normal (p.8).\u003c\/li\u003e\n\u003cli\u003eGlass and surrounding surfaces get hot. Supervise children and pets, and keep remotes out of reach (owner manual p.7).\u003c\/li\u003e\n\u003cli\u003eLearn the signs of carbon monoxide exposure (headache, dizziness, nausea); if they appear, get fresh air and have the heater serviced (p.8).\u003c\/li\u003e\n\u003cli\u003eHave the fireplace inspected annually by a qualified service technician (p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes; where none exist, follow the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNFPA 54 \/ ANSI Z223.1 National Fuel Gas Code\u003c\/a\u003e (pp.4, 8).\u003c\/li\u003e\n\u003cli\u003eIn Canada: \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1 Natural Gas and Propane Installation Code\u003c\/a\u003e (Canada) and \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (Canada) (p.4).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Hearth \u0026amp; Home Technologies (HHT) Limited Lifetime Warranty, form 4021-645N (12\/23), printed in the Artisan series owner manual (4099-902 Rev G), pp.4–5. Monessen is an HHT brand.\u003c\/li\u003e\n\u003cli\u003eAll parts and material, including handles and external enameled components: 1 year parts and labor (subject to the warranty conditions and exclusions).\u003c\/li\u003e\n\u003cli\u003eElectrical components (modules, remotes and wall switches, valves, pilots, blowers, junction boxes, wire harnesses, transformers and lights, excluding bulbs): 2 years.\u003c\/li\u003e\n\u003cli\u003eCement refractory panels and glass liner panels: 2 years.\u003c\/li\u003e\n\u003cli\u003eVented and vent-free burners and logs: 5 years.\u003c\/li\u003e\n\u003cli\u003eBurners, logs and metal\/fiber refractory components of HHT-manufactured fireplaces: 10 years parts, 1 year labor.\u003c\/li\u003e\n\u003cli\u003eFirebox and heat exchanger: 20 years parts, 3 years labor.\u003c\/li\u003e\n\u003cli\u003ePurchased replacement parts and optional accessories: 1 year parts, no labor.\u003c\/li\u003e\n\u003cli\u003eWho is covered: products bought from an HHT authorized dealer or distributor. Coverage transfers to later owners while the product stays at its original installation site, but the period is not extended. Valid only in the country where the selling dealer is authorized.\u003c\/li\u003e\n\u003cli\u003eWhen coverage starts: on the date of installation (new construction: six months after the final sale invoice, and no later than 24 months after HHT ships the product).\u003c\/li\u003e\n\u003cli\u003eHow service works: warranty service is arranged through the installing dealer or distributor. Travel and parts-shipping charges are not covered.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: normal wear items (paint, gaskets, firebricks, grates, flame guides, batteries, glass discoloration), normal finish color changes and cosmetic damage, noise from normal expansion and contraction, and damage from improper installation, operation or maintenance, code violations, inadequate ventilation, unauthorized modifications or a fuel other than the one specified. HHT does not guarantee heating capacity for a given space.\u003c\/li\u003e\n\u003cli\u003eThe warranty is void if the product is over-fired, operated in a chemically contaminated atmosphere, or damaged by prolonged dampness, condensation or water.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — AVFL60\u003c\/h3\u003e\n\u003ch4\u003eWhat size framing does the AVFL60 need?\u003c\/h4\u003e\u003cp\u003eThe framed opening is 64-5\/8\" W × 39-3\/4\" H × 13-1\/8\" D, or 13-3\/4\" D when finishing with Option 2. The back may sit against a combustible wall; keep 6\" from the inside of the appliance to a combustible side wall and 36\" from the opening to the ceiling. The 7-1\/4\" non-combustible facing board supplied must be installed.\u003c\/p\u003e\n\u003ch4\u003eDoes it need a chimney or vent?\u003c\/h4\u003e\u003cp\u003eNo. It is a vent-free fireplace listed to ANSI Z21.11.2 for unvented room heaters. The room, plus any rooms joined to it by openings without doors, must provide at least 50 cubic feet per 1,000 BTU\/h of total gas input, which is 2,000 cubic feet for this fireplace alone at its maximum input. It may not be installed in a bedroom or bathroom.\u003c\/p\u003e\n\u003ch4\u003eCan it be converted between natural gas and propane?\u003c\/h4\u003e\u003cp\u003eNo. Natural gas (AVFL60NIF) and propane (AVFL60PIF) are separate factory models, and field conversion is not permitted, so order the model that matches your gas supply. Propane installations need an external regulator.\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Four AA batteries (not included) in the battery backup let the remote turn the fire on and off when the power is out. The LED lights and other 120 V functions do not run on battery, and the backup is for emergency use, not as a long-term power source.\u003c\/p\u003e\n\u003ch4\u003eIs a remote included?\u003c\/h4\u003e\u003cp\u003eYes. The IFT2-RC450 touchscreen remote ships with it and controls on\/off, flame height, lights, thermostat, timer and child lock. An optional Wi-Fi module adds IntelliFire app control and Amazon Alexa and Google Assistant voice control.\u003c\/p\u003e\n\u003ch4\u003eCan a TV go above it, and how high must the mantel be?\u003c\/h4\u003e\u003cp\u003eYes. A combustible mantel must be at least 22\" above the top of the appliance opening and a non-combustible mantel at least 20\". Monessen's TV guideline gives a 28\" minimum TV height. Surrounding finishes must withstand 190°F.\u003c\/p\u003e","brand":"Monessen","offers":[{"title":"Natural Gas","offer_id":50592565756066,"sku":"AVFL60NIF","price":5399.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50592565788834,"sku":"AVFL60PIF","price":5399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Artisan-60-so-AVFL60NIF-AVFL60PIF.jpg?v=1795180033"},{"product_id":"superior-55-linear-direct-vent-clean-face-gas-fireplace-drl2055","title":"Superior 55\" Linear Direct Vent Gas Fireplace DRL2055","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Superior DRL2055 is the 55-inch model in the DRL2000 Series, a clean-face linear direct vent gas fireplace from Innovative Hearth Products with a low-profile, contemporary look for modern and transitional rooms. It is the value entry point to Superior's linear range: the same firebox, glass and venting as the DRL3500, with the blower, remote or wall controls added only if you want them. Step up to the DRL3500 for a blower, floor lighting and multi-function remote as standard.\u003c\/p\u003e\u003cp\u003eA sleek tempered-glass opening with a protective screen shows gently dancing flames rising through reflective black crushed glass over a black painted interior, in a durable textured powder-coat finish. Glass colors, river rock, driftwood, a porcelain liner and decorative surrounds personalize it, or tile can run right up to the integrated tile stops.\u003c\/p\u003e\u003cp\u003eIt runs from 23,000 to 19,000 BTU\/hr on natural gas and 21,000 to 17,000 BTU\/hr on propane through a manual high\/low valve, for comfortable zone heat. Four AA batteries keep the electronic ignition working in a power outage. It is approved for bedrooms and US manufactured homes, and vents horizontally or vertically up to 60 ft of total run with zero clearance to the framing spacers.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree linear widths\u003c\/strong\u003e: 35, 45 and 55-inch models (this is the 55-inch); choose by wall width and the room you want to heat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean-face design, durable textured powder-coat finish\u003c\/strong\u003e: integrated tile stops for easy finishing; black matte or stainless decorative surrounds complement drywall-finished installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard tempered glass and a protective screen\u003c\/strong\u003e: an exceptional view of the flames; meets ANSI Z21.88 barrier requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReflective black crushed glass included, black painted interior\u003c\/strong\u003e: reflective blue and platinum glass options, an optional black porcelain liner, and optional driftwood logs and river rock for a transitional design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic ignition with battery backup\u003c\/strong\u003e: SIT Proflame 1 intermittent pilot lights only when you call for fire and keeps working in a power outage (4 AA); the optional blower needs household power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutstanding heating efficiency\u003c\/strong\u003e: for increased comfort and lower operating costs (62.7% NG \/ 64.4% LP P.4.1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional blower, HeatFlo and controls\u003c\/strong\u003e: FBK-100\/200\/250 blowers (single or variable speed); HeatFlo kit HTFLO-DV55 directs heat out through a vent above the fireplace to protect art or a TV (45 and 55-inch only); on\/off, thermostat and timer remotes or wall controls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior SV4.5 \/ SF4.5 direct venting\u003c\/strong\u003e: rigid or flex 4-1\/2 x 7-1\/2 in. pipe, horizontal through a wall or vertical through the roof.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNatural gas or propane, approved locations\u003c\/strong\u003e: field-convertible with GCK-M-L2055NP \/ GCK-M-L2055PN; approved for bedrooms and manufactured homes (US) (manual pp.8, 12).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified, 20-year limited warranty\u003c\/strong\u003e: ANSI Z21.88\/CSA 2.33 and CAN\/CGA-2.17 vented gas fireplace heater; 20 years on the product body, firebox and barrier.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eDRL2055TEN (natural gas) \/ DRL2055TEP (propane), electronic ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eSuperior DRL2000 linear direct vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eClean-face linear direct vent gas fireplace, front view\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e55-1\/2\" W x 24-3\/4\" H x 17\" D (manual Table 11, p.18: E overall width, A overall height, J depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003e55-7\/8\" W x 29\" H x 18\" D, 2x4 or larger lumber (Superior; manual framing Table 10, p.18); flex-vent kits have their own framing requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e50\" W x 16-3\/4\" H glass viewing area (manual Table 11, p.18: D and C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eBack and sides 1\/2\" to the wrapper, 0\" to the spacers; top 0\" to the standoffs; floor 0\" (6\" with the optional surround); 52\" minimum from the fireplace base to the ceiling; front 36\" service clearance; vent 3\" above horizontal or inclined components, 1\" at the sides and bottom; shelf with top vent and one 90-degree elbow 62\" (Secure Vent) or 64\" (Secure Flex); combustible side walls 6\" minimum; combustible mantel 2\" deep at least 4\" above the hood, plus 2\" of height for each extra 2\" of depth, up to 12\" deep at 14\" above (Fig. 5); with the HeatFlo kit, 2\" deep at 2\" above up to 12\" deep at 12\" above (Fig. 5B); combustible mantel legs may project up to 3-1\/2\" from the face at the side edge of the fireplace, plus 1\" more for each inch farther out, to the 6\" side-wall line (Fig. 5C) (manual Tables 8-9, p.15; Figs. 5-5C, p.16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (high \/ low)\u003c\/th\u003e\n\u003ctd\u003e23,000 \/ 19,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (high \/ low)\u003c\/th\u003e\n\u003ctd\u003e21,000 \/ 17,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency (P.4.1)\u003c\/th\u003e\n\u003ctd\u003e62.7% NG \/ 64.4% LP (AFUE 69.4% \/ 64.8%) (Table 2, p.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eSIT Proflame 1 electronic intermittent pilot (IPI), manual high\/low valve, battery backup (4 AA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas supply\u003c\/th\u003e\n\u003ctd\u003eNG 5.0-10.5 in. WC; LP 11.0-13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManifold pressure\u003c\/th\u003e\n\u003ctd\u003eNG 3.5 in. WC; LP 10.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrifice (0-4,500 ft)\u003c\/th\u003e\n\u003ctd\u003e#47 (0.0785 in.) NG; #55 (0.052 in.) LP (Table 5, p.10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e120 VAC household power required (backup batteries for ignition only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eSuperior SV4.5 \/ SF4.5 4-1\/2 x 7-1\/2 in. direct vent (or Z-Flex Model GA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBlower\u003c\/th\u003e\n\u003ctd\u003eOptional: FBK-100 single speed, FBK-200 variable speed with wall switch, FBK-250 variable speed with thermal switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRemote \/ controls\u003c\/th\u003e\n\u003ctd\u003eOptional: RCKIT4001, RC-S-1, RC-S-STAT remotes; WS-S-TSTAT, WS-S-TMR, FWSK wall controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMedia included\u003c\/th\u003e\n\u003ctd\u003eReflective black crushed glass (7.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e133 lb (manual p.72)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eANSI Z21.88\/CSA 2.33, CAN\/CGA-2.17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e20-year limited (body, firebox and barrier)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace: 55-1\/2 in. wide x 24-3\/4 in. high x 17 in. deep; glass viewing area 50 in. wide x 16-3\/4 in. high (Table 11, p.18).\u003c\/li\u003e\n\u003cli\u003eFraming: 55-7\/8 in. wide x 29 in. high x 18 in. deep (Superior DRL2000 page; manual framing Table 10, p.18), framed with 2x4 or larger lumber. Framing values do not apply to flex-vent kits, which have their own requirements (p.18).\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: back and sides 1\/2 in. to the wrapper and 0 in. to the spacers; top 0 in. to the standoffs; floor 0 in. (6 in. with the optional surround); 52 in. minimum from the fireplace base to the ceiling; 36 in. front service clearance (Table 8, p.15).\u003c\/li\u003e\n\u003cli\u003eVent pipe: 3 in. above any horizontal or inclined vent component, 1 in. at the sides and bottom (Table 8, p.15).\u003c\/li\u003e\n\u003cli\u003eShelf height with a top vent and one 90-degree elbow: 62 in. with Secure Vent rigid, 64 in. with Secure Flex (Table 9, p.15).\u003c\/li\u003e\n\u003cli\u003eThe fireplace is approved for zero clearance to the spacers but cannot be recessed; a side wall flush with one side must not extend past the front edge (p.15).\u003c\/li\u003e\n\u003cli\u003eMantels: a combustible mantel 2 in. deep must be at least 4 in. above the hood, and each extra 2 in. of depth needs 2 in. more height, up to 12 in. deep at 14 in. above (Fig. 5); with the HeatFlo kit the chart starts at 2 in. deep at 2 in. above and runs to 12 in. deep at 12 in. above (Fig. 5B, p.16); non-combustible mantels may be at any height, but nothing may hang below the hood. Combustible side walls need 6 in. minimum side clearance; combustible mantel legs may stand beside the opening if they project no more than 3-1\/2 in. from the fireplace face at its side edge, plus 1 in. more for each inch farther out (a 45-degree line), up to the 6 in. side-wall line (Fig. 5C).\u003c\/li\u003e\n\u003cli\u003eTV above: flush wall - at least 12 in. above the opening, 3 in. below the vent opening, vent opening 4 in. below the ceiling; recessed pocket - 18 in. above the opening, 3-1\/2 in. maximum depth; follow the TV maker's temperature limits (Figs. 6\/6A, pp.19-20).\u003c\/li\u003e\n\u003cli\u003eHeatFlo installs: framed opening 55-7\/8 in. wide x 18 in. high above the fireplace, 3-1\/2 in. maximum recess (Table 12, p.19).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with burner, SIT Proflame 1 electronic ignition and manual high\/low valve\u003c\/li\u003e\n\u003cli\u003eTempered glass with protective barrier screen (F4250)\u003c\/li\u003e\n\u003cli\u003eReflective black crushed glass media (7.5 lb)\u003c\/li\u003e\n\u003cli\u003e2.75 in. non-combustible board with two side brackets and one center bracket (packaging list, p.8)\u003c\/li\u003e\n\u003cli\u003eTwo U-shaped vent restrictors and a minimal vent run baffle\u003c\/li\u003e\n\u003cli\u003eBattery holder for 4 AA backup batteries; 15 ft of two-conductor wire\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired (sold separately)\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSuperior SV4.5 \/ SF4.5 4-1\/2\"x7-1\/2\" direct vent system: a horizontal termination (SV4.5HT-2, SV4.5TK90HT2, small-square SV4.5 options, SF4.5HT-2 or an SFKIT flex kit) or a vertical termination (SV4.5GV-1 with roof flashing SV4.5F, SV4.5FA or SV4.5FB, or SFVT30\/SFVT45 for flex), plus pipe, elbows and firestops for the route\u003c\/li\u003e\n\u003cli\u003eAttic insulation shield where the vent passes blown or loose-fill insulation (manual H3907; store SV4.5RSA)\u003c\/li\u003e\n\u003cli\u003eWall heat shield extension kit F3694 for walls thicker than 12 in. (installer)\u003c\/li\u003e\n\u003cli\u003e120 VAC electrical supply and gas supply line (by the installer)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGas conversion kit: natural gas to propane GCK-M-L2055NP (F4466), propane to natural gas GCK-M-L2055PN (F4472) (Table 26, p.54)\u003c\/li\u003e\n\u003cli\u003eBlower kit: FBK-100 (80L84) single speed, FBK-200 (80L85) variable speed with wall switch, or FBK-250 (80L86) variable speed with thermal snap switch (pp.49, 65)\u003c\/li\u003e\n\u003cli\u003eControls: RCKIT4001 on\/off remote (F2236), RC-S-1 remote (H8860), RC-S-STAT remote with thermostat (H8861), WS-S-TSTAT wall thermostat (H8864), WS-S-TMR timer wall switch (H8863), FWSK on\/off wall switch kit (85L87), FRS rocker switch (80L41); VSWS variable speed wall switch (045571H, with FBK-100) (p.66)\u003c\/li\u003e\n\u003cli\u003eDecorative surround: black matte DS-BLK-RNCL55 (F4242) or stainless DS-SS-RNCL55 (F4243)\u003c\/li\u003e\n\u003cli\u003eBlack porcelain liner kit PLK-BLK-RNCL55 (F4246)\u003c\/li\u003e\n\u003cli\u003eDriftwood log set DWLS-RNCL55 (F4442)\u003c\/li\u003e\n\u003cli\u003eRiver rock, 25-piece kit RIVROCK-25PK (F3775)\u003c\/li\u003e\n\u003cli\u003eCrushed glass, 5 lb bags (two bags; use 7.5 lb): reflective black CRSHGL-RBLK, reflective blue CRSHGL-RBLU, platinum CRSHGL-P\u003c\/li\u003e\n\u003cli\u003eHeatFlo convection kit HTFLO-DV55 (F4453) and HeatFlo flex extension HTFLO-EK-4.5 (F4578, 60 in.)\u003c\/li\u003e\n\u003cli\u003eTermination guards: SV4.5HGS (deluxe) or SV4.5HGS-1 (small square)\u003c\/li\u003e\n\u003cli\u003eTouch-up paint: firebox interior SCITPSAB, powder-coat exterior SCTPSAB\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eProduct video\u003c\/h3\u003e\u003cp\u003eOfficial Superior videos for the DRL2000 Series:\u003c\/p\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/BOCST33TP18\" title=\"Superior DRL2055 Burn Video\" frameborder=\"0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/QZVRinrwwmE\" title=\"Superior DRL2000 Burn Video\" frameborder=\"0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/XpMTnAZ3M9Y\" title=\"Superior DRL2000 Facade Burn Video\" frameborder=\"0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/tTkbn0p1Pzk\" title=\"Superior DRL2000 Product Video\" frameborder=\"0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This fireplace must be installed and serviced by a qualified professional following the Superior installation manual (DRL2000\/DRL3500, P\/N 900994-00 Rev. N). If you ever smell gas, do not light any appliance or touch electrical switches; leave the building and call your gas supplier from outside.\u003c\/p\u003e\u003ch4\u003eSafety and your fireplace\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eListed by PFS TECO (report F19-008) to ANSI Z21.88\/CSA 2.33 and CAN\/CGA-2.17 as a vented gas fireplace heater (pp.6, 8).\u003c\/li\u003e\n\u003cli\u003eThe barrier screen (F4250) must be in place before operating; never run the fireplace with the glass removed, cracked or broken (p.6).\u003c\/li\u003e\n\u003cli\u003eNever connect to private wellhead gas; doing so voids the warranty (p.6).\u003c\/li\u003e\n\u003cli\u003eThe glass and surrounding surfaces get very hot: supervise children and pets and keep furniture and combustibles away from the front.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas pressure and high altitude\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInlet: NG 5.0-10.5 in. WC, LP 11.0-13.0 in. WC; manifold NG 3.5 in. WC, LP 10.0 in. WC; test ports on the valve (p.9).\u003c\/li\u003e\n\u003cli\u003eOrifices for 0-4,500 ft: NG #47 (0.0785 in.), LP #55 (0.052 in.) (Table 5, p.10). Above 4,500 ft derate per the gas supplier or local authority; flame size drops about 4% per 1,000 ft (p.10).\u003c\/li\u003e\n\u003cli\u003eDisconnect the fireplace from the gas line when pressure-testing above 1\/2 psi (p.10).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMassachusetts, cold climates and manufactured homes\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMassachusetts: 248 CMR 4.00-8.00 applies - licensed installer, 36 in. maximum flex connector, T-handle shutoff and extra CO detector rules for horizontal vents under 7 ft (p.11).\u003c\/li\u003e\n\u003cli\u003eCold climates: seal cracks around the fireplace with non-combustible material, insulate an outside chase between the studs and under a raised floor, and caulk gas-line holes or stuff them with unfaced fiberglass; do not use loose or blown-in insulation around the fireplace. On a cement slab, a plywood sheet or raised platform under the unit limits cold transfer (p.11).\u003c\/li\u003e\n\u003cli\u003eManufactured homes (US only, where local codes allow): ground the fireplace to the chassis and do not weaken structural members (p.12).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eLocation and vent termination clearances\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eTermination clearances (Table 7, p.14), for example: 12 in. above grade, decks or balconies; 9 in. from an opening window or door (10,000-50,000 BTU\/hr); 18 in. below a ventilated soffit; 36 in. horizontally from a gas meter or regulator; 84 in. above a public sidewalk or driveway.\u003c\/li\u003e\n\u003cli\u003eVertical terminations must clear the roof by the pitch table (Table 6, p.13): 1 ft up to 6\/12, rising to 8 ft at 21\/12.\u003c\/li\u003e\n\u003cli\u003eKeep terminations above the expected snow line, away from roof runoff, and fit a guard where people could touch them (pp.33-36).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMinimum clearances to combustibles\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBack and sides 1\/2 in. to the wrapper, 0 in. to spacers; top 0 in. to standoffs; floor 0 in. (6 in. with the optional surround); 52 in. base to ceiling; vent 3 in. above and 1 in. at the sides and bottom (Table 8, p.15).\u003c\/li\u003e\n\u003cli\u003eA fully supported base is required; combustible flooring other than wood needs a metal or wood panel under the fireplace (p.15).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWall finishes, surrounds and mantels\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCombustible wall finishes and surrounds may not encroach on the fireplace face; non-combustible trim up to 6 in. deep may overlap the face but must not cover the removable glass or block barrier removal (p.16).\u003c\/li\u003e\n\u003cli\u003eCombustible mantels: 4 in. above the hood at 2 in. deep, up to 14 in. above at 12 in. deep (2 in. to 12 in. with HeatFlo, Figs. 5-5B); paint the underside of a combustible mantel with paint rated 175°F or higher. Non-combustible mantels may be at any height (p.16).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation: framing, gas and electrical\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFrame the opening (55-7\/8 in. wide) with 2x4 or larger lumber and build a solid platform when the fireplace is raised (pp.17-18).\u003c\/li\u003e\n\u003cli\u003eFit the top spacers, the non-combustible front fireboard standoff and the header shield; route the gas line and rough in the electrical supply before placing and securing the fireplace (pp.21-23).\u003c\/li\u003e\n\u003cli\u003eRoute a 3-wire, 120 VAC, 60 Hz, single-phase supply to the fireplace junction box; ground per code (pp.8, 41).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVent system\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUse only Superior Secure Vent SV4.5, Secure Flex SF4.5 or Z-Flex Model GA 4-1\/2 x 7-1\/2 in. components (UL 1777 \/ ULC S635); do not mix brands (p.8).\u003c\/li\u003e\n\u003cli\u003eStraight vertical runs: 6 ft minimum, 60 ft maximum; with two 90-degree elbows up to 25 ft horizontal, with three elbows up to 20 ft horizontal (Tables 17-18, pp.31-32).\u003c\/li\u003e\n\u003cli\u003eInstall the U-shaped restrictor on any run with more than 6 ft of vertical rise, and the minimal vent run part listed for this model in Table 13 (pp.23-24).\u003c\/li\u003e\n\u003cli\u003e55-inch models need 1 ft of vertical rise directly off the fireplace before an elbow (p.15).\u003c\/li\u003e\n\u003cli\u003eWall terminations: walls up to 9-1\/4 in. with the termination kit alone, up to 20 in. with extra sections and a telescopic section (Table 19, p.36); the wall heat shield keeps 1-1\/4 in. clearance to the pipe (p.34).\u003c\/li\u003e\n\u003cli\u003eSupport vertical runs every 8 ft and horizontal runs every 5 ft; never join separate sections of concentric flex pipe (pp.29-31).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eControls, interior options and finishing\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOptional remotes and wall switches wire to the Proflame 1 ignition module (pp.41, 55); follow the instructions supplied with the control.\u003c\/li\u003e\n\u003cli\u003eSpread the reflective black glass media evenly (7.5 lb maximum for this size); install the optional porcelain liner panels before the media (pp.47, 58-59).\u003c\/li\u003e\n\u003cli\u003eReinstall the hood and barrier screen; finishing materials must keep the required clearances and must not block the glass or barrier (pp.49-50).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eOperation, burn-in and maintenance\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFollow the burn-in instructions for the first fires and ventilate the room while the finish cures (p.57).\u003c\/li\u003e\n\u003cli\u003eFour AA batteries keep the ignition working in a power outage; the optional blower needs household power (p.8).\u003c\/li\u003e\n\u003cli\u003eHave a qualified technician inspect the burner, controls, glass gasket and vent system at least once a year, following the maintenance schedule (pp.62-64).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAccessories named in the manual\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eSurrounds F4242\/F4243, porcelain liner F4246, driftwood logs F4442, glass media H8412\/H8424\/H8413, river rock F3775, touch-up paint F1881\/F1882, HeatFlo F4453 with extension F4578, termination guards H5820\/87L02\/17M52 (pp.52-53, 64-66).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes or, where none apply, the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eIn Canada: \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1 Natural Gas and Propane Installation Code\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eElectrical: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e in Canada.\u003c\/li\u003e\n\u003cli\u003ePropane tank sizing: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-58-standard-development\/58\"\u003eNFPA 58 Liquefied Petroleum Gas Code\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eVent listings: \u003ca href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL1777\"\u003eUL 1777\u003c\/a\u003e and ULC S635 (p.8).\u003c\/li\u003e\n\u003cli\u003eMassachusetts: 248 CMR 4.00-8.00, with CO detection to NFPA 720 \/ UL 2034 (pp.10-11).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage: Innovative Hearth Products Superior Brand Gas Fireplaces, Stoves and Inserts Limited Warranty (P\/N 900223-00 Rev. C), printed in the installation manual (manual p.75).\u003c\/li\u003e\n\u003cli\u003eProduct body, firebox and barrier: 20 years. Ceramic glass: 20 years against thermal breakage only.\u003c\/li\u003e\n\u003cli\u003eBurner, gas components and gaskets: 1 year. Tempered glass: 1 year. Logs: 1 year, thermal breakage only.\u003c\/li\u003e\n\u003cli\u003eOptional blowers and remote controls: 1 year. Optional glass doors: 90 days. Parts not otherwise listed: 90 days.\u003c\/li\u003e\n\u003cli\u003eLabor: paid at IHP's prevailing rates during each component's warranty period, up to five years.\u003c\/li\u003e\n\u003cli\u003eVent components, trim and paint are not covered by the 20-year term.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner only (not transferable); bought from an IHP-listed supplier, with proof of purchase.\u003c\/li\u003e\n\u003cli\u003eConditions: installed in the US or Canada by an IHP-approved licensed contractor to local codes, and operated and maintained per the instructions.\u003c\/li\u003e\n\u003cli\u003eExclusions: normal wear; accident, fire or flood; abuse, misuse or alteration; lack of maintenance; faulty installation; burning wood, coal or other solid fuel; draft problems caused by HVAC, the vent configuration or building conditions.\u003c\/li\u003e\n\u003cli\u003eClaims: contact the selling dealer; if that is not possible, notify IHP in writing within 90 days of the failure. Replacement parts are generally available for 10 years after the last manufacture date.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/10\/900994-00_N_SUP_DRL2000_DRL3500_35-45-55_TEN-TEP_DV_FP_SIT-PF1_PF2_IICO.pdf\"\u003eInstallation and Operation Manual (DRL2000\/DRL3500, P\/N 900994-00)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/900994-01_F_SUP_DRL2000_DRL3500_35-45-55_TEN-TEP_DV_FP_SIT-PF1_PF2_SPEC.pdf\"\u003eSpecification Sheet (DRL2000\/DRL3500, P\/N 900994-01)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/785726M_DRL2000-1026-WEB.pdf\"\u003eDRL2000 Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2022\/05\/785821M-DRL2000-Smart-Sheet-1026-WEB.pdf\"\u003eDRL2000 Smart Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/901068-00_B_IHP_HeatFlo_Kit_HTFLO-Compass_INSTR.pdf\"\u003eHeatFlo Kit Instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/901067-00_A_IHP_Heat-Flo_Extension_Kit_INSTR-1.pdf\"\u003eHeatFlo Extension Kit Instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including Carbon Black, which is known to the State of California to cause cancer, and Carbon Monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — DRL2055\u003c\/h3\u003e\u003ch4\u003eWhat size framing does the DRL2055 need?\u003c\/h4\u003e\u003cp\u003eFrame an opening 55-7\/8 in. wide x 29 in. high x 18 in. deep with 2x4 or larger lumber. The unit itself measures 55-1\/2 in. wide x 24-3\/4 in. high x 17 in. deep, with zero clearance to the spacers. Framing values do not apply to flex-vent kits, which have their own requirements.\u003c\/p\u003e\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eSuperior Secure Vent SV4.5 rigid or Secure Flex SF4.5 4-1\/2 x 7-1\/2 in. direct vent pipe (or Z-Flex Model GA), horizontally through a wall or vertically through the roof. Straight vertical runs are 6 ft minimum and 60 ft maximum; with two 90-degree elbows it can run up to 25 ft horizontally, with three elbows up to 20 ft. The 55-inch model needs 1 ft of vertical rise off the fireplace before an elbow.\u003c\/p\u003e\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. Four AA batteries keep the SIT Proflame 1 electronic ignition working, so the fire still lights. The optional blower needs household power.\u003c\/p\u003e\u003ch4\u003eIs a remote included?\u003c\/h4\u003e\u003cp\u003eNo. Remotes are optional: RCKIT4001 on\/off, RC-S-1, or RC-S-STAT with thermostat, or the WS-S-TSTAT wall thermostat, WS-S-TMR timer wall switch or FWSK on\/off wall switch.\u003c\/p\u003e\u003ch4\u003eCan a TV go above it?\u003c\/h4\u003e\u003cp\u003eYes. On a flush wall the TV must be at least 12 in. above the opening and 3 in. below the vent opening, with the vent opening 4 in. below the ceiling. In a recessed pocket it must be 18 in. above the opening, with a 3-1\/2 in. maximum pocket depth. Follow the TV maker's temperature limits as well.\u003c\/p\u003e\u003ch4\u003eCan it be converted between natural gas and propane?\u003c\/h4\u003e\u003cp\u003eYes. It ships as DRL2055TEN (natural gas) or DRL2055TEP (propane) and is field-convertible with kit GCK-M-L2055NP (natural gas to propane) or GCK-M-L2055PN (propane to natural gas).\u003c\/p\u003e","brand":"Superior","offers":[{"title":"Natural Gas \/ Electronic Ignition","offer_id":50593236549794,"sku":"DRL2055TEN","price":3849.0,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Electronic Ignition","offer_id":50593236582562,"sku":"DRL2055TEP","price":3849.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Superior-dvfp-drl2000_B_PD-1136x852-1_14d1ce21-ac96-4cc1-a506-218b5eaad9df.jpg?v=1793402838"},{"product_id":"superior-55-linear-vent-free-gas-fireplace-vrl3055","title":"Superior 55\" Vent-Free Gas Fireplace VRL3055","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Superior VRL3055 is the 55-inch, larger of the two VRL3000 Series linear vent-free gas fireplaces from Innovative Hearth Products, sharing its design and manual with the 45-inch model. Its modern, low-profile look suits contemporary and transitional rooms, and with no chimney or vent pipe it fits interior walls, condos, remodels and rooms where venting would be difficult. Compared with the direct vent DRL3500 Series, it gives the same linear look without any venting.\u003c\/p\u003e\u003cp\u003eFlames dance through platinum crushed glass over a black painted interior, framed by a standard black bezel with a protective barrier screen, while six-setting floor lighting glows through the media with or without a fire. Optional liners, glass colors, driftwood, river rocks and surrounds personalize it.\u003c\/p\u003e\u003cp\u003eAll of its heat stays in the room at 99.9% efficiency: 28,000 to 22,000 BTU\/hr on natural gas and 27,000 to 21,000 BTU\/hr on propane, in a space of about 1,400 cu ft or more on natural gas. Electronic ignition runs on household power with battery backup, so it still lights in a power outage, and an oxygen depletion sensor shuts it off if fresh air runs low. It is not for bedrooms or bathrooms.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo linear sizes\u003c\/strong\u003e: 45 and 55-inch models; this is the 55-inch model, a long ribbon of flame for great rooms and wide feature walls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVent-free, 99.9% efficient\u003c\/strong\u003e: no chimney, vent pipe or termination and no hearth extension required (p.15); all the heat stays in the room for exceptional heating and lower operating costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeatFlo kit or variable-speed blower options\u003c\/strong\u003e: fine-tune your heating with HTFLO-VF55, which sends warm air out through a vent above the fireplace so art or a TV can hang above it, or FBK-100; they may not be installed in the same appliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic ignition with battery backup\u003c\/strong\u003e: runs on household power, with continued operation in the event of a power outage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-function remote included\u003c\/strong\u003e: IPI\/CPI pilot mode, room thermostat, flame height, blower and lighting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen depletion sensor (ODS)\u003c\/strong\u003e: on the pilot, shuts the fireplace off if there is not enough fresh air (manual pp.5-6).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard black bezel and barrier screen, black painted interior\u003c\/strong\u003e: optional black porcelain liner available; black matte or stainless decorative surrounds complement drywall-finished applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatinum crushed glass media included\u003c\/strong\u003e: with several optional colors to customize the look, plus optional driftwood logs and river rocks, a perfect addition for a transitional design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloor lighting\u003c\/strong\u003e: mood-enhancing lighting with six distinctive settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified and manufactured-home approved, 20-year limited warranty\u003c\/strong\u003e: ANSI Z21.11.2 unvented gas-fired room heater listed by PFS TECO (report F21-664); for permanently located manufactured or mobile homes where local codes allow (p.13); 20 years on the product body, firebox and barrier.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eVRL3055ZEN natural gas \/ VRL3055ZEP propane, electronic ignition; catalog F4685 (ZEN) \/ F4686 (ZEP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eSuperior VRL3000 linear vent-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eClean-face linear vent-free gas fireplace, front view\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e55-1\/2\" W x 24-3\/4\" H x 17\" D overall; 52-7\/8\" wide at the base and 44-3\/4\" across the back (manual Table 8 drawing, p.17; mm 1410 \/ 629 \/ 432)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003e55-7\/8\" W x 29\" H x 18\" D (add 1\/8\" per side recommended; depth for flush framing); corner: 58-1\/2\" along each wall, 82-3\/4\" across the front, 41-3\/8\" from the corner to the front (manual Table 7, p.17). HeatFlo: 81-1\/2\" minimum from base to ceiling (Table 9, p.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eBack and sides 1\/2\" to the wrapper, 0\" to the spacers; top 0\" to the standoffs; floor 0\" (6\" with the optional surround); 52\" minimum from the base of the unit to the ceiling (81-1\/2\" with HeatFlo); 36\" front service clearance; combustible shelf at least 33\" above the base; side wall 6\" or more away may project any length; vertical clearance to a combustible mantel 18\" at 2\" deep, 20\" at 4\", 22\" at 6\", 24\" at 8\", 26\" at 10\" and 28\" at 12\" deep (4\" to 14\" for the same depths with HeatFlo); non-combustible mantels at any height (manual Table 5 p.14, Table 6 and Figs. 4-4B p.15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas (high \/ low)\u003c\/th\u003e\n\u003ctd\u003e28,000 \/ 22,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane (high \/ low)\u003c\/th\u003e\n\u003ctd\u003e27,000 \/ 21,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e99.9% (vent-free)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum room volume (NG high fire)\u003c\/th\u003e\n\u003ctd\u003eabout 1,400 cu ft (manual rule: volume x 20 = max BTU\/hr, pp.7-8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eSIT Proflame electronic, selectable IPI\/CPI, battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas supply\u003c\/th\u003e\n\u003ctd\u003eNG 5.0-10.5 in. WC; LP 11.0-13.0 in. WC; 3\/8 in. NPT valve inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManifold pressure\u003c\/th\u003e\n\u003ctd\u003eNG 3.5 in. WC; LP 10.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrifice (0-4,500 ft)\u003c\/th\u003e\n\u003ctd\u003e#40 (0.098 in.) NG; #53 (0.0595 in.) LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0-4,500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e120 VAC, 60 Hz, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eNone (vent-free)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBlower\u003c\/th\u003e\n\u003ctd\u003eOptional FBK-100 variable speed (not with HeatFlo)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLighting\u003c\/th\u003e\n\u003ctd\u003eFloor lighting, six settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRemote\u003c\/th\u003e\n\u003ctd\u003eMulti-function remote included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMedia included\u003c\/th\u003e\n\u003ctd\u003ePlatinum crushed glass; use 5 lb (the whole bag)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e170 lb (manual p.43)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eANSI Z21.11.2 (PFS TECO report F21-664)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e20-year limited (body, firebox and barrier)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace: 55-1\/2 in. wide at the top (52-7\/8 in. at the base, 44-3\/4 in. across the back) x 24-3\/4 in. high x 17 in. deep (Table 8, p.17).\u003c\/li\u003e\n\u003cli\u003eFraming: 55-7\/8 in. wide x 29 in. high x 18 in. deep, framed with 2x4 or larger lumber; an extra 1\/8 in. per side is recommended. Corner framing: 58-1\/2 in. along each wall, 82-3\/4 in. across the front and 41-3\/8 in. from the corner to the front (Table 7, p.17).\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: back and sides 1\/2 in. to the wrapper and 0 in. to the spacers; top 0 in. to the standoffs; floor 0 in. (6 in. with the optional surround); 52 in. from the bottom of the unit to the ceiling; 36 in. front service clearance (Table 5, p.14).\u003c\/li\u003e\n\u003cli\u003eKeep furniture, curtains and other combustibles at least 36 in. from the front and 42 in. from the top (p.11).\u003c\/li\u003e\n\u003cli\u003eShelf: a combustible shelf at least 33 in. above the base of the unit; do not insulate the space between the unit and the shelf (Table 6, p.15).\u003c\/li\u003e\n\u003cli\u003eSide walls: with one side flush to a wall, the other wall may not extend past the front edge; a combustible side wall 6 in. or more away can project any length (Fig. 4B, p.15).\u003c\/li\u003e\n\u003cli\u003eMantels: the vertical clearance to a combustible mantel rises with its depth: 18 in. for a 2 in. deep mantel, 20 in. for 4 in., 22 in. for 6 in., 24 in. for 8 in., 26 in. for 10 in. and 28 in. for 12 in. (Fig. 4, p.15); with the HeatFlo kit installed it is 4, 6, 8, 10, 12 and 14 in. for the same depths (Fig. 4A). Non-combustible mantels may be at any height, but nothing may hang below the hood.\u003c\/li\u003e\n\u003cli\u003eTV above (HeatFlo installs): flush wall - at least 18 in. above the opening, 3 in. below the vent opening, vent opening 6 in. below the ceiling; recessed pocket - 18 in. above the opening, 3-1\/2 in. maximum depth, 3 in. clearance on all sides; follow the TV maker's temperature limits (Figs. 5\/5A, pp.18-19).\u003c\/li\u003e\n\u003cli\u003eHeatFlo framing: 81-1\/2 in. minimum from the base to the ceiling, 5-1\/8 in. minimum from the framed opening to the ceiling, 3-1\/2 in. maximum recess (Table 9, p.18).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with burner, ODS pilot and SIT Proflame electronic controls\u003c\/li\u003e\n\u003cli\u003eStandard black barrier bezel with protective screen (replacement F4724)\u003c\/li\u003e\n\u003cli\u003ePlatinum crushed glass media, 5 lb bag\u003c\/li\u003e\n\u003cli\u003eMulti-function remote control (3 AAA in the transmitter, 4 AA in the receiver)\u003c\/li\u003e\n\u003cli\u003eBurner glass panel with mounting brackets and two-piece media tray\u003c\/li\u003e\n\u003cli\u003eFlexible gas connector with shutoff valve\u003c\/li\u003e\n\u003cli\u003e8 in. non-combustible board with two side brackets and one center bracket\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired (sold separately)\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGas supply line to the fireplace shutoff (by the installer); propane systems need a tank of at least 100 lb capacity located outdoors (p.13)\u003c\/li\u003e\n\u003cli\u003e120 VAC, 60 Hz single-phase electrical supply to the junction box (by the installer)\u003c\/li\u003e\n\u003cli\u003eA room large enough for the input: at least 50 cu ft per 1,000 BTU\/hr of all gas appliances in it (about 1,400 cu ft on natural gas), or, in a smaller space, two permanent ventilation openings, one within 12 in. of the ceiling and one within 12 in. of the floor, into an adjoining room or to the outdoors (pp.7-9)\u003c\/li\u003e\n\u003cli\u003eNo vent pipe, termination or hearth extension is required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDecorative surround: black matte DS-BLK-RNCL55 (F4242) or stainless DS-SS-RNCL55 (F4243)\u003c\/li\u003e\n\u003cli\u003eBlack porcelain liner kit PLK-BLK-RNCL55 (F4246)\u003c\/li\u003e\n\u003cli\u003eVariable-speed blower kit FBK-100 (not with HeatFlo)\u003c\/li\u003e\n\u003cli\u003eHeatFlo kit HTFLO-VF55 (F4761) with optional flex extension HTFLO-EK-4.5 (F4578, 60 in.) and coverplate kit F4579 (not with the blower)\u003c\/li\u003e\n\u003cli\u003eCrushed glass, 5 lb bags: reflective black CRSHGL-RBLK (H8412), reflective blue CRSHGL-RBLU (H8424), platinum CRSHGL-P (H8413)\u003c\/li\u003e\n\u003cli\u003eDriftwood log set DWLS-VFL55 (F4717)\u003c\/li\u003e\n\u003cli\u003eRiver rock 25-piece kit RIVROCK-25PK (F3775)\u003c\/li\u003e\n\u003cli\u003eTouch-up paint: firebox interior SCITPSAB (F1881), powder-coat exterior SCTPSAB (F1882)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eProduct video\u003c\/h3\u003e\u003cp\u003eOfficial Superior videos for the VRL3000 Series:\u003c\/p\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/Q8R6qFS36HU\" title=\"VRL3055 Burn Video\" frameborder=\"0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/QkK8iyzBuQc\" title=\"VRL3000 Product Video\" frameborder=\"0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This vent-free fireplace must be installed and serviced by a qualified professional following the Superior VRL3000 installation manual (P\/N 901149-00 Rev. F), in a room large enough for its input. If you ever smell gas, do not light any appliance or touch electrical switches; leave the building and call your gas supplier from outside.\u003c\/p\u003e\u003ch4\u003eGeneral information and safety\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eListed by PFS TECO (report F21-664) to ANSI Z21.11.2 as an unvented gas-fired room heater (pp.2, 12).\u003c\/li\u003e\n\u003cli\u003eNever install in a bedroom or bathroom, a recreational vehicle, a high-traffic, windy or drafty area, or where flammable vapors or heavy dust are present (pp.5, 11).\u003c\/li\u003e\n\u003cli\u003eThe barrier bezel must be installed before operating. Never burn wood, paper or other materials in it, and never direct fans at the fireplace, which can cause sooting (pp.2-6).\u003c\/li\u003e\n\u003cli\u003eDo not use the fireplace if any part has been under water; have a qualified technician inspect it (p.5).\u003c\/li\u003e\n\u003cli\u003eCarbon monoxide symptoms resemble the flu; if they appear, get fresh air and have the fireplace serviced (pp.2-6).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAir for combustion and ventilation\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eThe space must hold at least 50 cu ft per 1,000 BTU\/hr of all gas appliances in it; only adjoining rooms without doors (or with ventilation grills) count (pp.7-8).\u003c\/li\u003e\n\u003cli\u003eIf the space is too small, add permanent openings (one within 12 in. of the ceiling and one within 12 in. of the floor), connect more space, or choose a lower-BTU unit; very tight homes need extra fresh air (pp.8-9).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas pressure, orifices and altitude\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInlet: NG 5.0-10.5 in. WC, LP 11.0-13.0 in. WC; manifold NG 3.5 in. WC, LP 10.0 in. WC (Tables 2-3, p.12).\u003c\/li\u003e\n\u003cli\u003eFactory orifices for 0-4,500 ft: NG #40 (0.098 in.), LP #53 (0.0595 in.) (Table 4, p.13). Not approved above 4,500 ft - the pilot may go out.\u003c\/li\u003e\n\u003cli\u003eDisconnect the fireplace when pressure-testing above 1\/2 psi; leak-test with a bubble solution, never a flame (pp.13, 20).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMassachusetts and manufactured homes\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMassachusetts: 527 CMR 30 applies - licensed plumber or gas fitter, flexible connector no longer than 36 in., T-handle shutoff, no bedrooms or bathrooms, and a working smoke detector (p.13).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: permanently located homes only, where local codes allow; ground the fireplace to the chassis and do not cut or weaken cross members (pp.13-14).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eLocation, clearances, hearth and mantels\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBack and sides 1\/2 in. to the wrapper, 0 in. to spacers; top 0 in.; floor 0 in. (6 in. with the surround); 52 in. to the ceiling; 36 in. front service clearance (Table 5, p.14).\u003c\/li\u003e\n\u003cli\u003eNo hearth extension is required; the floor must be a solid, fully supported base, with a metal or wood panel over carpet or vinyl (p.15).\u003c\/li\u003e\n\u003cli\u003eCombustible shelves at least 33 in. above the base; combustible mantels need 18 in. of vertical clearance at 2 in. deep, rising 2 in. for every 2 in. of depth to 28 in. at 12 in. deep (Fig. 4, p.15).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation: framing, gas and electrical\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFrame the 55-7\/8 x 29 x 18 in. opening, fit the top spacers and the non-combustible front fireboard standoff, then route the gas line and rough in the electrical supply before placing and securing the fireplace (pp.16-21).\u003c\/li\u003e\n\u003cli\u003eRun a 3-wire, 120 VAC, 60 Hz, single-phase supply to the junction box and ground it per the National Electrical Code or local code (pp.21-23).\u003c\/li\u003e\n\u003cli\u003eAfter connecting the gas, purge the line - several restarts may be needed - and verify operation (pp.24-25).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinal installation: remote, media and options\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInitialize the remote to the receiver before first use (p.25).\u003c\/li\u003e\n\u003cli\u003eSpread the platinum glass evenly - 5 lb (the whole bag) - and never place glass on the burner (pp.12, 32).\u003c\/li\u003e\n\u003cli\u003eInstall optional porcelain liner panels and the driftwood logs as shown in the manual; let the burner run 5 minutes before adjusting the air shutter (pp.26-27, 33-35).\u003c\/li\u003e\n\u003cli\u003eReinstall the hood and the barrier bezel; install the optional FBK-100 blower per its section (blower and HeatFlo cannot be combined) (pp.28-29, 38).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eOperation, burn-in and maintenance\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eExpect odor and light haze from paint curing on the first burns; ventilate the room (smoke alarms may sound) and do not run the blower during break-in (pp.5, 31).\u003c\/li\u003e\n\u003cli\u003eThe flame may start blue and turn yellow-orange within about 5 minutes (p.31).\u003c\/li\u003e\n\u003cli\u003eInspect at least once a year following the maintenance schedule; shut off gas and power before cleaning, and turn the heater off before using furniture polish nearby (pp.36-38).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAccessories named in the manual\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eHeatFlo F4761 with extension F4578 and coverplate F4579, blower FBK-100, surrounds F4242\/F4243, porcelain liner F4246, driftwood F4717, glass media H8412\/H8424\/H8413, river rock F3775, touch-up paint F1881\/F1882, replacement bezel F4724 (pp.38-40).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes or, where none apply, the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e (or the International Fuel Gas Code where adopted).\u003c\/li\u003e\n\u003cli\u003eIn Canada: \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1 Natural Gas and Propane Installation Code\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eElectrical: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e, or \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e in Canada.\u003c\/li\u003e\n\u003cli\u003ePropane storage and piping: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-58-standard-development\/58\"\u003eNFPA 58 Liquefied Petroleum Gas Code\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eMassachusetts: 527 CMR 30 for unvented gas room heaters; see the \u003ca href=\"https:\/\/www.law.cornell.edu\/regulations\/massachusetts\/department-527-CMR\"\u003e527 CMR Board of Fire Prevention Regulations\u003c\/a\u003e (p.13).\u003c\/li\u003e\n\u003cli\u003eProduct listing: ANSI Z21.11.2 Gas-Fired Room Heaters, Unvented.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage: Innovative Hearth Products Superior brand limited warranty printed at the end of the installation manual (P\/N 901149-00 Rev. F).\u003c\/li\u003e\n\u003cli\u003eProduct body, firebox and barrier: 20 years from installation. Ceramic glass: 20 years against thermal breakage only.\u003c\/li\u003e\n\u003cli\u003eBurner, gas components and gaskets: 1 year. Tempered glass: 1 year. Logs: 1 year, thermal breakage only.\u003c\/li\u003e\n\u003cli\u003eOptional blowers and remote controls: 1 year. Optional glass doors: 90 days. Parts not otherwise listed: 90 days.\u003c\/li\u003e\n\u003cli\u003eLabor: paid at IHP's prevailing rates during each component's warranty period, up to five years.\u003c\/li\u003e\n\u003cli\u003eVent components, trim and paint are not covered by the 20-year term.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner only (not transferable); installed in the US or Canada. Coverage starts on the purchase date (for new construction, at first occupancy or six months after the dealer sale, whichever is earlier).\u003c\/li\u003e\n\u003cli\u003eConditions: installed and repaired by a licensed contractor approved by IHP, to local codes, and operated and maintained per the instructions.\u003c\/li\u003e\n\u003cli\u003eExclusions: normal wear; accident, fire or flood; abuse, misuse or alteration; burning wood, coal or other solid fuel; lack of maintenance; faulty installation; problems caused by HVAC, negative pressure or the environment; undersized propane tanks; extra utility bills.\u003c\/li\u003e\n\u003cli\u003eClaims: contact the selling dealer; if that is not possible, notify IHP in writing within 90 days of the failure. Replacement parts are generally available for 10 years after the last manufacture date.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/901149-00_F_SUP_VRL30_45-55_ZEN-ZEP_VF_FP_SIT_IICO.pdf\"\u003eInstallation and Operation Manual (VRL3045\/VRL3055, P\/N 901149-00)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/901150-01_A_SUP_VRL30_45-55_ZEN_ZEP_VF_FP_SIT_SPEC.pdf\"\u003eSpecification Sheet (VRL3000, P\/N 901150-01)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/Superior_785743M_VRL3000_06.18.21_WEB.pdf\"\u003eVRL3000 Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2022\/05\/785835M-VRL3000-Smart-Sheet-WEB-0322.pdf\"\u003eVRL3000 Smart Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/901155-00_B_IHP_HeatFlo_Kit_HTFLO-VF45_VF55_EpsilonLX_INSTR.pdf\"\u003eHeatFlo Kit Instructions (HTFLO-VF45\/VF55)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/901067-00_A_IHP_Heat-Flo_Extension_Kit_INSTR-1.pdf\"\u003eHeatFlo Extension Kit Instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon black, which is known to the State of California to cause cancer, and carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — VRL3055\u003c\/h3\u003e\u003ch4\u003eWhat size framing does the VRL3055 need?\u003c\/h4\u003e\u003cp\u003eFrame an opening 55-7\/8 in. wide x 29 in. high x 18 in. deep with 2x4 or larger lumber, adding 1\/8 in. per side as recommended. For a corner, the framing runs 58-1\/2 in. along each wall and 82-3\/4 in. across the front. The fireplace itself is 55-1\/2 in. wide, 24-3\/4 in. high and 17 in. deep, with zero clearance to the spacers and no hearth extension.\u003c\/p\u003e\u003ch4\u003eDoes it need a chimney or vent?\u003c\/h4\u003e\u003cp\u003eNo. It is a vent-free fireplace, so no vent pipe, termination or roof or wall penetration is needed. The room must be large enough for its input: about 1,400 cu ft on natural gas, or, in a smaller space, two permanent ventilation openings (one within 12 in. of the ceiling and one within 12 in. of the floor) into an adjoining room or to the outdoors. It may not go in a bedroom or bathroom.\u003c\/p\u003e\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. The electronic ignition runs on a 120 VAC supply with battery backup, so the fire still lights when the power is out. The remote uses 3 AAA batteries in the transmitter and 4 AA in the receiver.\u003c\/p\u003e\u003ch4\u003eCan a TV go above it?\u003c\/h4\u003e\u003cp\u003eYes, with the HeatFlo kit HTFLO-VF55. On a flush wall the TV must be at least 18 in. above the opening and 3 in. below the HeatFlo vent opening, which sits 6 in. below the ceiling; a recessed pocket may be up to 3-1\/2 in. deep with 3 in. clearance on all sides. HeatFlo needs 81-1\/2 in. from the base to the ceiling.\u003c\/p\u003e\u003ch4\u003eCan it be converted between natural gas and propane?\u003c\/h4\u003e\u003cp\u003eNo. It ships as a natural gas (VRL3055ZEN) or propane (VRL3055ZEP) model and is only for use with the gas on its rating plate. Order the model that matches your fuel; propane installations need a tank of at least 100 lb located outdoors.\u003c\/p\u003e\u003ch4\u003eWhat is the warranty?\u003c\/h4\u003e\u003cp\u003eA 20-year limited warranty on the product body, firebox and barrier, and 20 years on ceramic glass against thermal breakage; 1 year on the burner, gas components, gaskets, remote and optional blower. Labor is paid at IHP's rates within each component's period, up to five years, for the original owner.\u003c\/p\u003e","brand":"Superior","offers":[{"title":"Natural Gas","offer_id":50593237172386,"sku":"VRL3055ZEN","price":4399.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50593237205154,"sku":"VRL3055ZEP","price":4399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/superior-vrl3055-1.jpg?v=1793378844"},{"product_id":"superior-36-vent-free-gas-firebox-vrt3536","title":"Superior 36\" Vent Free Gas Firebox VRT3536","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Superior VRT3536 is the 36-inch model of the VRT3500 Series of louverless vent-free fireboxes from Innovative Hearth Products; a 42-inch model is also made. It is a factory-built enclosure for a separately purchased vent-free gas log set, so there is no chimney, which makes it a natural fit for renovations, remodels, apartments and condos.\u003c\/p\u003e\u003cp\u003eInside, white refractory panels in a stacked (WS) or herringbone (WH) pattern line a tall 28-inch, full-width opening, with mesh fire screens across the front and a clean, louver-free face in textured black powder coat. Marble, stone, tile or brick finishes it off, and a raised hearth may be added.\u003c\/p\u003e\u003cp\u003ePair it with any vent-free gas log heater listed to ANSI Z21.11.2 up to 40,000 BTU\/h. Options include the FC36 heat-deflection hood, FBK-100 or FBK-200 blowers, decorative screen panels and an outside air kit, and the firebox carries Superior's 20-year limited warranty.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo widths\u003c\/strong\u003e: 36 and 42 in. models; this is the 36 in., with a 35 in. interior front width.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTall, full-width opening\u003c\/strong\u003e: 28 in. high refractory opening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhite refractory panels\u003c\/strong\u003e: stacked VRT3536WS or herringbone VRT3536WH pattern.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMesh fire screens included\u003c\/strong\u003e: two screens on rods.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLouverless face\u003c\/strong\u003e: durable textured black powder-coat finish.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVent-free\u003c\/strong\u003e: no chimney or vent pipe; listed by PFS Corporation to ANSI Z21.91 as a ventless firebox enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas log choice\u003c\/strong\u003e: accepts ANSI Z21.11.2 vent-free gas log heaters up to 40,000 BTU\/h; sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional hood\u003c\/strong\u003e: FC36 heat-deflection hood (H1989); needed only to use the with-hood mantel clearances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional blower and outside air\u003c\/strong\u003e: FBK-100 single-speed or FBK-200 variable-speed blower, and the OAK-UVFRC outside air kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20-year limited warranty\u003c\/strong\u003e: product body, firebox and barrier, with IHP paying labor for up to five years.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eVRT3536WS (white stacked refractory, catalog F0298) and VRT3536WH (white herringbone refractory, catalog F0299)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eLouverless vent-free firebox enclosure for a separately purchased vent-free gas log heater, indoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003e42-1\/4\" W x 44-1\/4\" H x 20-1\/2\" D parallel framing (Superior VRT3536 specifications; manual 900238-01 Table 1); the depth is to the back wall of the chase or enclosure including finishing materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e28\" high, full-width refractory opening; interior front width 35\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eCeiling at least 40\" above the top of the firebox opening; side wall at least 16\" from the opening; no combustible material closer than 3\" to the opening; a combustible side projection of 5\" at least 6\" from the side of the opening; non-combustible material 3\" minimum above the appliance; top spacers must not be removed or modified, and a header may touch but not rest on them; mantel or trim projecting 4\" about 13\" or more above the opening with the hood (manual Fig. 4); projecting 7\" about 18\" or more above the opening without the hood (manual Fig. 5) or about 19\" or more (spec sheet 900668-01) - Superior prints both; floor: may sit on a combustible floor on a fully supported base covering its full width and depth; carpet or vinyl needs a metal or wood barrier; raised hearth 5-3\/4\" maximum from the base to the bottom of the opening, no carpet or vinyl; curtains, furniture and other flammables at least 42\" from the front (manual Figs. 2a, 4, 5; spec sheet 900668-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterior firebox\u003c\/th\u003e\n\u003ctd\u003e35\" front width, 23-1\/4\" rear width, 17-3\/8\" deep, 28\" high (manual and spec sheet 900668-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeater requirement\u003c\/th\u003e\n\u003ctd\u003eListed gas-fired unvented decorative room heater to ANSI Z21.11.2, not over 40,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListing\u003c\/th\u003e\n\u003ctd\u003ePFS Corporation, ANSI Z21.91 ventless firebox enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eGas only through the listed vent-free log heater; no wood or unapproved logs, embers or decorative materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eNone (vent-free); adequate combustion and ventilation air is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e200 lb, 22 cu. ft. (installation manual 900238-01) or 180 lb, 22.9 cu. ft. (spec sheet 900668-01) - Superior prints both; same for WS and WH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e20-year limited (see Warranty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVent-free gas firebox with white stacked (WS) or herringbone (WH) refractory panel set (F3528 \/ F3396)\u003c\/li\u003e\n\u003cli\u003eTwo mesh fire screens (H2694) on screen rods (H3919)\u003c\/li\u003e\n\u003cli\u003eInstallation and operation instructions with warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eListed vent-free decorative gas log heater to ANSI Z21.11.2, not over 40,000 BTU\/h (sold separately)\u003c\/li\u003e\n\u003cli\u003eApproved gas line, 1\/2 in. minimum to 1-1\/2 in. maximum inside diameter, connected before the firebox is enclosed, with a sediment trap upstream of the heater if the line has none (no galvanized or plastic pipe)\u003c\/li\u003e\n\u003cli\u003ePropane: an external regulator that limits supply pressure to 13 in. W.C., in addition to the heater's regulator\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing (marble, stone, tile or brick) wherever anything overlaps the black front face\u003c\/li\u003e\n\u003cli\u003eFor either blower: the JBK junction box kit (junction box H6048)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFC36 heat-deflection hood (H1989); must be in place to use the with-hood mantel clearances\u003c\/li\u003e\n\u003cli\u003eFBK-100 single-speed blower with ON\/OFF switch (80L84)\u003c\/li\u003e\n\u003cli\u003eFBK-200 variable-speed blower with wall control (80L85)\u003c\/li\u003e\n\u003cli\u003eFWSK ON\/OFF wall switch kit (85L87)\u003c\/li\u003e\n\u003cli\u003eOAK-UVFRC outside air gate and duct kit (H3991), right side\u003c\/li\u003e\n\u003cli\u003eDecorative screen door panel ASD3628-TI (H1960)\u003c\/li\u003e\n\u003cli\u003eRaised hearth extension (may be combustible, but not carpet or vinyl), 5-3\/4 in. maximum from the base to the bottom of the opening\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e A vent-free firebox and gas log heater that are installed or used incorrectly can cause fire, carbon-monoxide exposure or injury. Have a qualified installer set the firebox and connect the gas exactly as the Superior VRT3536\/VRT3542 installation and operation manual (P\/N 900238-01 Rev. F) and the log heater's own manual describe.\u003c\/p\u003e\u003ch4\u003eImportant safety information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNever burn wood, coal or other solid fuel, and never add unapproved logs, embers or decorative materials.\u003c\/li\u003e\n\u003cli\u003eNot for sleeping rooms, bathrooms, sleeping quarters or recreational vehicles.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003ePackaging list\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eThe carton holds the vent-free gas firebox and the installation and operation instructions; the hood, blower and decorative screen panels are separate options.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eCombustion and ventilation air\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eProvisions for adequate combustion and ventilation air must be made: a space is confined when it has less than 50 cu. ft. per 1,000 BTU\/h of input, and the worksheet multiplies room volume by 20 for the maximum BTU\/h the room supports.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eRequirements for the Commonwealth of Massachusetts\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eInstall to 527 CMR 30 by a licensed plumber or gas fitter; flexible connector 36 in. maximum; T-handle manual shut-off; no unvented appliance in bedrooms or bathrooms; a working smoke detector in the area; sellers give buyers a copy of 527 CMR 30.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eLocation of firebox and clearances\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eClearances: Ceiling at least 40\" above the top of the firebox opening; side wall at least 16\" from the opening; no combustible material closer than 3\" to the opening; a combustible side projection of 5\" at least 6\" from the side of the opening; non-combustible material 3\" minimum above the appliance; top spacers must not be removed or modified, and a header may touch but not rest on them; mantel or trim projecting 4\" about 13\" or more above the opening with the hood (manual Fig. 4); projecting 7\" about 18\" or more above the opening without the hood (manual Fig. 5) or about 19\" or more (spec sheet 900668-01) - Superior prints both; floor: may sit on a combustible floor on a fully supported base covering its full width and depth; carpet or vinyl needs a metal or wood barrier; raised hearth 5-3\/4\" maximum from the base to the bottom of the opening, no carpet or vinyl; curtains, furniture and other flammables at least 42\" from the front (manual Figs. 2a, 4, 5; spec sheet 900668-01).\u003c\/li\u003e\n\u003cli\u003eDo not use the appliance for structural support, obstruct its openings or fill clearance spaces with insulation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas line installation\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eApproved line 1\/2 in. to 1-1\/2 in. ID, never galvanized or plastic; sediment trap upstream of the heater; propane needs an external regulator to 13 in. W.C. maximum and internally tinned copper tubing; connect the line before the firebox is enclosed.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eFirebox framing and installation\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eParallel framing 42-1\/4 in. W x 44-1\/4 in. H x 20-1\/2 in. D (Table 1, Fig. 9); corner installation per Fig. 10.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eHood installation\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eThe FC36 hood (H1989) is optional, but it must be in place to use the with-hood clearances (Fig. 4); never substitute a hood supplied with an unrelated log heater.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eOptional equipment \/ blower kit installation\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eFBK-100 (single speed, ON\/OFF switch) or FBK-200 (variable speed, wall control); either blower needs the JBK junction box kit (H6048).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eFirebox finishes\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eOnly non-combustible materials such as marble, stone, tile or brick may overlap the black front facing; seal the joints with non-combustible caulk.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eReplacement parts\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eFire screen H2694 (2), screen rod H3919 (2), refractory panel set F3528 (WS) \/ F3396 (WH), hood H1989, junction box H6048.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eGas: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, the International Fuel Gas Code, and in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eElectrical: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e; in Canada the CSA C22.1 Canadian Electrical Code.\u003c\/li\u003e\n\u003cli\u003eMassachusetts: 527 CMR 30. Listings: ANSI Z21.91 (firebox) and ANSI Z21.11.2 (heater).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSuperior 20 Year Limited Warranty printed in the installation manual (warranty P\/N 900223-00).\u003c\/li\u003e\n\u003cli\u003eProduct body, firebox and barrier: 20 years. Ceramic glass: 20 years, thermal breakage only.\u003c\/li\u003e\n\u003cli\u003eBurner, gas components, gaskets, logs (thermal breakage only), optional blowers, remote controls and tempered glass: 1 year.\u003c\/li\u003e\n\u003cli\u003eOptional glass doors and parts not listed: 90 days.\u003c\/li\u003e\n\u003cli\u003eLabor: IHP pays its prevailing labor rates for covered repairs for up to five years.\u003c\/li\u003e\n\u003cli\u003eNot covered: vent components, trim components and paint.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/900238-01_F_SUP_VRT3536-42_VF_Fireboxes_IICO.pdf\"\u003eInstallation and Operation Manual (VRT3536\/VRT3542, P\/N 900238-01 Rev. F)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/900668-01_B_SUP_VRT3500_36-42_WS-WH_VF_Firebox_SPEC.pdf\"\u003eSpecification Sheet (P\/N 900668-01 Rev. B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/785450M_VRT3500_0725-WEB.pdf\"\u003eVRT3500 Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2022\/05\/785842M-VRT3500-Smart-Sheet-0725-WEB.pdf\"\u003eVRT3500 Smart Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/785692M_Superior-GasLogs-0926-WEB.pdf\"\u003eSuperior Gas Logs Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — VRT3536\u003c\/h3\u003e\u003ch4\u003eWhat size framing does the VRT3536 need?\u003c\/h4\u003e\u003cp\u003eFrame 42-1\/4 in. wide x 44-1\/4 in. high x 20-1\/2 in. deep for a flat-wall installation, measured to the back wall including finishing materials; keep the ceiling at least 40 in. above the top of the opening and side walls at least 16 in. away.\u003c\/p\u003e\u003ch4\u003eDoes it need a chimney or vent?\u003c\/h4\u003e\u003cp\u003eNo. It is a vent-free firebox enclosure listed to ANSI Z21.91, so no chimney or vent pipe is used, but the room needs enough combustion air: under 50 cu. ft. per 1,000 BTU\/h of input is a confined space.\u003c\/p\u003e\u003ch4\u003eWhat gas logs can I use?\u003c\/h4\u003e\u003cp\u003eAny listed vent-free decorative gas log heater to ANSI Z21.11.2 with an input of 40,000 BTU\/h or less; the logs are sold separately.\u003c\/p\u003e\u003ch4\u003eIs the hood required?\u003c\/h4\u003e\u003cp\u003eNo. The FC36 hood (H1989) is optional, but it must be installed to use the with-hood mantel clearances (a 4 in. mantel about 13 in. above the opening).\u003c\/p\u003e\u003ch4\u003eIs a blower available?\u003c\/h4\u003e\u003cp\u003eYes. The optional FBK-100 single-speed blower (80L84) or FBK-200 variable-speed blower (80L85); either one also needs the JBK junction box kit.\u003c\/p\u003e\u003ch4\u003eCan it go in a bedroom or bathroom?\u003c\/h4\u003e\u003cp\u003eNo. It may not be installed in sleeping rooms, bathrooms, sleeping quarters or recreational vehicles.\u003c\/p\u003e","brand":"Superior","offers":[{"title":"White Stacked Liner","offer_id":50593237860514,"sku":"VRT3536WS","price":999.0,"currency_code":"USD","in_stock":true},{"title":"White Herringbone Liner","offer_id":50593237893282,"sku":"VRT3536WH","price":1109.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Superior-36-Vent-Free-Gas-Firebox-VRT3536_3037__71641.1785139778.1280.1280.jpg?v=1792471239"},{"product_id":"superior-42-vent-free-gas-firebox-vrt3542","title":"Superior 42\" Vent Free Gas Firebox VRT3542","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Superior VRT3542 is the 42-inch model of the VRT3500 Series of louverless vent-free fireboxes from Innovative Hearth Products; a 36-inch model is also made. It is a factory-built enclosure for a separately purchased vent-free gas log set, so there is no chimney, which makes it a natural fit for renovations, remodels, apartments and condos.\u003c\/p\u003e\u003cp\u003eInside, white refractory panels in a stacked (WS) or herringbone (WH) pattern line a tall 28-inch, full-width opening, with mesh fire screens across the front and a clean, louver-free face in textured black powder coat. Marble, stone, tile or brick finishes it off, and a raised hearth may be added.\u003c\/p\u003e\u003cp\u003ePair it with any vent-free gas log heater listed to ANSI Z21.11.2 up to 40,000 BTU\/h. Options include the FC42 heat-deflection hood, FBK-100 or FBK-200 blowers, decorative screen panels and an outside air kit, and the firebox carries Superior's 20-year limited warranty.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo widths\u003c\/strong\u003e: 36 and 42 in. models; this is the 42 in., with a 41 in. interior front width.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTall, full-width opening\u003c\/strong\u003e: 28 in. high refractory opening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhite refractory panels\u003c\/strong\u003e: stacked VRT3542WS or herringbone VRT3542WH pattern.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMesh fire screens included\u003c\/strong\u003e: two screens on rods.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLouverless face\u003c\/strong\u003e: durable textured black powder-coat finish.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVent-free\u003c\/strong\u003e: no chimney or vent pipe; listed by PFS Corporation to ANSI Z21.91 as a ventless firebox enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas log choice\u003c\/strong\u003e: accepts ANSI Z21.11.2 vent-free gas log heaters up to 40,000 BTU\/h; sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional hood\u003c\/strong\u003e: FC42 heat-deflection hood (H1990); needed only to use the with-hood mantel clearances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional blower and outside air\u003c\/strong\u003e: FBK-100 single-speed or FBK-200 variable-speed blower, and the OAK-UVFRC outside air kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20-year limited warranty\u003c\/strong\u003e: product body, firebox and barrier, with IHP paying labor for up to five years.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eVRT3542WS (white stacked refractory, catalog F0300) and VRT3542WH (white herringbone refractory, catalog F0301)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eLouverless vent-free firebox enclosure for a separately purchased vent-free gas log heater, indoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003e48-1\/4\" W x 44-1\/4\" H x 20-1\/2\" D parallel framing (Superior VRT3542 specifications; manual 900238-01 Table 1); the depth is to the back wall of the chase or enclosure including finishing materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e28\" high, full-width refractory opening; interior front width 41\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eCeiling at least 40\" above the top of the firebox opening; side wall at least 16\" from the opening; no combustible material closer than 3\" to the opening; a combustible side projection of 5\" at least 6\" from the side of the opening; non-combustible material 3\" minimum above the appliance; top spacers must not be removed or modified, and a header may touch but not rest on them; mantel or trim projecting 4\" about 13\" or more above the opening with the hood (manual Fig. 4); projecting 7\" about 18\" or more above the opening without the hood (manual Fig. 5) or about 19\" or more (spec sheet 900668-01) - Superior prints both; floor: may sit on a combustible floor on a fully supported base covering its full width and depth; carpet or vinyl needs a metal or wood barrier; raised hearth 5-3\/4\" maximum from the base to the bottom of the opening, no carpet or vinyl; curtains, furniture and other flammables at least 42\" from the front (manual Figs. 2a, 4, 5; spec sheet 900668-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterior firebox\u003c\/th\u003e\n\u003ctd\u003e41\" front width, 29-1\/4\" rear width, 17-3\/8\" deep, 28\" high (manual and spec sheet 900668-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeater requirement\u003c\/th\u003e\n\u003ctd\u003eListed gas-fired unvented decorative room heater to ANSI Z21.11.2, not over 40,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListing\u003c\/th\u003e\n\u003ctd\u003ePFS Corporation, ANSI Z21.91 ventless firebox enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eGas only through the listed vent-free log heater; no wood or unapproved logs, embers or decorative materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eNone (vent-free); adequate combustion and ventilation air is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e230 lb, 26 cu. ft. (installation manual 900238-01) or 207 lb, 28.6 cu. ft. (spec sheet 900668-01) - Superior prints both; same for WS and WH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e20-year limited (see Warranty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVent-free gas firebox with white stacked (WS) or herringbone (WH) refractory panel set (F3529 \/ F3530)\u003c\/li\u003e\n\u003cli\u003eTwo mesh fire screens (H2699) on screen rods (H2700)\u003c\/li\u003e\n\u003cli\u003eInstallation and operation instructions with warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eListed vent-free decorative gas log heater to ANSI Z21.11.2, not over 40,000 BTU\/h (sold separately)\u003c\/li\u003e\n\u003cli\u003eApproved gas line, 1\/2 in. minimum to 1-1\/2 in. maximum inside diameter, connected before the firebox is enclosed, with a sediment trap upstream of the heater if the line has none (no galvanized or plastic pipe)\u003c\/li\u003e\n\u003cli\u003ePropane: an external regulator that limits supply pressure to 13 in. W.C., in addition to the heater's regulator\u003c\/li\u003e\n\u003cli\u003eNon-combustible facing (marble, stone, tile or brick) wherever anything overlaps the black front face\u003c\/li\u003e\n\u003cli\u003eFor either blower: the JBK junction box kit (junction box H6048)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFC42 heat-deflection hood (H1990); must be in place to use the with-hood mantel clearances\u003c\/li\u003e\n\u003cli\u003eFBK-100 single-speed blower with ON\/OFF switch (80L84)\u003c\/li\u003e\n\u003cli\u003eFBK-200 variable-speed blower with wall control (80L85)\u003c\/li\u003e\n\u003cli\u003eFWSK ON\/OFF wall switch kit (85L87)\u003c\/li\u003e\n\u003cli\u003eOAK-UVFRC outside air gate and duct kit (H3991), right side\u003c\/li\u003e\n\u003cli\u003eDecorative screen door panel ASD4228-TI (H1961)\u003c\/li\u003e\n\u003cli\u003eRaised hearth extension (may be combustible, but not carpet or vinyl), 5-3\/4 in. maximum from the base to the bottom of the opening\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e A vent-free firebox and gas log heater that are installed or used incorrectly can cause fire, carbon-monoxide exposure or injury. Have a qualified installer set the firebox and connect the gas exactly as the Superior VRT3536\/VRT3542 installation and operation manual (P\/N 900238-01 Rev. F) and the log heater's own manual describe.\u003c\/p\u003e\u003ch4\u003eImportant safety information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNever burn wood, coal or other solid fuel, and never add unapproved logs, embers or decorative materials.\u003c\/li\u003e\n\u003cli\u003eNot for sleeping rooms, bathrooms, sleeping quarters or recreational vehicles.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003ePackaging list\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eThe carton holds the vent-free gas firebox and the installation and operation instructions; the hood, blower and decorative screen panels are separate options.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eCombustion and ventilation air\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eProvisions for adequate combustion and ventilation air must be made: a space is confined when it has less than 50 cu. ft. per 1,000 BTU\/h of input, and the worksheet multiplies room volume by 20 for the maximum BTU\/h the room supports.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eRequirements for the Commonwealth of Massachusetts\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eInstall to 527 CMR 30 by a licensed plumber or gas fitter; flexible connector 36 in. maximum; T-handle manual shut-off; no unvented appliance in bedrooms or bathrooms; a working smoke detector in the area; sellers give buyers a copy of 527 CMR 30.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eLocation of firebox and clearances\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eClearances: Ceiling at least 40\" above the top of the firebox opening; side wall at least 16\" from the opening; no combustible material closer than 3\" to the opening; a combustible side projection of 5\" at least 6\" from the side of the opening; non-combustible material 3\" minimum above the appliance; top spacers must not be removed or modified, and a header may touch but not rest on them; mantel or trim projecting 4\" about 13\" or more above the opening with the hood (manual Fig. 4); projecting 7\" about 18\" or more above the opening without the hood (manual Fig. 5) or about 19\" or more (spec sheet 900668-01) - Superior prints both; floor: may sit on a combustible floor on a fully supported base covering its full width and depth; carpet or vinyl needs a metal or wood barrier; raised hearth 5-3\/4\" maximum from the base to the bottom of the opening, no carpet or vinyl; curtains, furniture and other flammables at least 42\" from the front (manual Figs. 2a, 4, 5; spec sheet 900668-01).\u003c\/li\u003e\n\u003cli\u003eDo not use the appliance for structural support, obstruct its openings or fill clearance spaces with insulation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas line installation\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eApproved line 1\/2 in. to 1-1\/2 in. ID, never galvanized or plastic; sediment trap upstream of the heater; propane needs an external regulator to 13 in. W.C. maximum and internally tinned copper tubing; connect the line before the firebox is enclosed.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eFirebox framing and installation\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eParallel framing 48-1\/4 in. W x 44-1\/4 in. H x 20-1\/2 in. D (Table 1, Fig. 9); corner installation per Fig. 10.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eHood installation\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eThe FC42 hood (H1990) is optional, but it must be in place to use the with-hood clearances (Fig. 4); never substitute a hood supplied with an unrelated log heater.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eOptional equipment \/ blower kit installation\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eFBK-100 (single speed, ON\/OFF switch) or FBK-200 (variable speed, wall control); either blower needs the JBK junction box kit (H6048).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eFirebox finishes\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eOnly non-combustible materials such as marble, stone, tile or brick may overlap the black front facing; seal the joints with non-combustible caulk.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eReplacement parts\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eFire screen H2699 (2), screen rod H2700 (2), refractory panel set F3529 (WS) \/ F3530 (WH), hood H1990, junction box H6048.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eGas: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, the International Fuel Gas Code, and in Canada \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eElectrical: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e; in Canada the CSA C22.1 Canadian Electrical Code.\u003c\/li\u003e\n\u003cli\u003eMassachusetts: 527 CMR 30. Listings: ANSI Z21.91 (firebox) and ANSI Z21.11.2 (heater).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSuperior 20 Year Limited Warranty printed in the installation manual (warranty P\/N 900223-00).\u003c\/li\u003e\n\u003cli\u003eProduct body, firebox and barrier: 20 years. Ceramic glass: 20 years, thermal breakage only.\u003c\/li\u003e\n\u003cli\u003eBurner, gas components, gaskets, logs (thermal breakage only), optional blowers, remote controls and tempered glass: 1 year.\u003c\/li\u003e\n\u003cli\u003eOptional glass doors and parts not listed: 90 days.\u003c\/li\u003e\n\u003cli\u003eLabor: IHP pays its prevailing labor rates for covered repairs for up to five years.\u003c\/li\u003e\n\u003cli\u003eNot covered: vent components, trim components and paint.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/900238-01_F_SUP_VRT3536-42_VF_Fireboxes_IICO.pdf\"\u003eInstallation and Operation Manual (VRT3536\/VRT3542, P\/N 900238-01 Rev. F)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/900668-01_B_SUP_VRT3500_36-42_WS-WH_VF_Firebox_SPEC.pdf\"\u003eSpecification Sheet (P\/N 900668-01 Rev. B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/785450M_VRT3500_0725-WEB.pdf\"\u003eVRT3500 Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2022\/05\/785842M-VRT3500-Smart-Sheet-0725-WEB.pdf\"\u003eVRT3500 Smart Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/785692M_Superior-GasLogs-0926-WEB.pdf\"\u003eSuperior Gas Logs Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — VRT3542\u003c\/h3\u003e\u003ch4\u003eWhat size framing does the VRT3542 need?\u003c\/h4\u003e\u003cp\u003eFrame 48-1\/4 in. wide x 44-1\/4 in. high x 20-1\/2 in. deep for a flat-wall installation, measured to the back wall including finishing materials; keep the ceiling at least 40 in. above the top of the opening and side walls at least 16 in. away.\u003c\/p\u003e\u003ch4\u003eDoes it need a chimney or vent?\u003c\/h4\u003e\u003cp\u003eNo. It is a vent-free firebox enclosure listed to ANSI Z21.91, so no chimney or vent pipe is used, but the room needs enough combustion air: under 50 cu. ft. per 1,000 BTU\/h of input is a confined space.\u003c\/p\u003e\u003ch4\u003eWhat gas logs can I use?\u003c\/h4\u003e\u003cp\u003eAny listed vent-free decorative gas log heater to ANSI Z21.11.2 with an input of 40,000 BTU\/h or less; the logs are sold separately.\u003c\/p\u003e\u003ch4\u003eIs the hood required?\u003c\/h4\u003e\u003cp\u003eNo. The FC42 hood (H1990) is optional, but it must be installed to use the with-hood mantel clearances (a 4 in. mantel about 13 in. above the opening).\u003c\/p\u003e\u003ch4\u003eIs a blower available?\u003c\/h4\u003e\u003cp\u003eYes. The optional FBK-100 single-speed blower (80L84) or FBK-200 variable-speed blower (80L85); either one also needs the JBK junction box kit.\u003c\/p\u003e\u003ch4\u003eCan it go in a bedroom or bathroom?\u003c\/h4\u003e\u003cp\u003eNo. It may not be installed in sleeping rooms, bathrooms, sleeping quarters or recreational vehicles.\u003c\/p\u003e","brand":"Superior","offers":[{"title":"White Stacked Liner","offer_id":50593237991586,"sku":"VRT3542WS","price":1219.0,"currency_code":"USD","in_stock":true},{"title":"White Herringbone Liner","offer_id":50593238024354,"sku":"VRT3542WH","price":1329.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Superior-42-Vent-Free-Gas-Firebox-VRT3542_3038__28756.1785139780.1280.1280.jpg?v=1792471254"},{"product_id":"superior-36-wood-burning-traditional-fireplace-wrt-wct2036","title":"Superior 36\" Wood-Burning Traditional Fireplace WRT\/WCT2036","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Superior WRT\/WCT2036 is the 36-inch model of the WRT\/WCT2000 Series, the value-priced entry into Superior's traditional wood-burning fireplaces. It is a factory-built, zero-clearance, open-hearth fireplace from Innovative Hearth Products that brings a real wood fire into a new home or remodel, framed with ordinary wood studs instead of site-built masonry.\u003c\/p\u003e\u003cp\u003eOne listing covers both front styles: the Radiant WRT has a clean, smooth face, while the Louvered WCT adds rolled louvers above and below the opening for heat circulation and accepts an optional fan kit. White stacked refractory panels give a traditional masonry look inside a textured powder-coat finish, and the fully insulated firebox helps in colder climates. Like every open-hearth wood fireplace, it is built for ambiance and supplemental heat.\u003c\/p\u003e\u003cp\u003eIt vents through the IHP 8 in. 8DM double-wall chimney (8HT stainless, required in Canada). Options include BDB36 bi-fold glass doors and AK4 \/ AK4F outside air kits, and it is approved for vented gas logs and, with the GA6050 hood, vent-free gas log heaters.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo sizes\u003c\/strong\u003e: 36 in. and 42 in. models; this is the 36 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiant or louvered front\u003c\/strong\u003e: smooth-faced WRT2036WSI or circulating rolled-louver WCT2036WSI, selectable on this listing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully insulated firebox\u003c\/strong\u003e: better performance in colder climates; firebox 34-3\/4 in. front width, 19-3\/8 in. rear, 14-1\/2 in. deep, 21-1\/2 in. high.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhite stacked refractory panels\u003c\/strong\u003e: traditional masonry look; refractory stain kits change the color.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLog grate and mesh fire screens included\u003c\/strong\u003e, with push\/pull damper control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutside air\u003c\/strong\u003e: barometric, adjustable outside air damper with optional AK4 (sidewall) or AK4F (floor\/crawl space) kits; gas line and outside air knockouts on the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas log ready\u003c\/strong\u003e: approved for vented gas logs (ANSI Z21.60 \/ Z21.84) and vent-free gas log heaters (ANSI Z21.11.2, GA6050 hood required).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit for the WCT\u003c\/strong\u003e: BK manual variable-speed fan kit (F1081) for the louvered model only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance installation\u003c\/strong\u003e: 3\/4 in. at the back and sides, 0 in. at the floor and top spacers; listed to UL 127 and CAN\/ULC-S610.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20-year limited warranty\u003c\/strong\u003e: Superior wood-burning fireplace warranty with labor paid up to five years.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eWRT2036WSI (radiant, smooth face) and WCT2036WSI (circulating, rolled louvers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eIndoor open-hearth, zero-clearance wood-burning fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003e38-1\/4\" W x 38-5\/8\" H x 22\" D (manual 126628-01 Figure 1 framing, p.5; spec sheet 900728-00 framing dimensions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eBack and sides 3\/4\" (not required at the nailing flanges); floor 0\"; top spacers 0\"; chimney outer pipe surface 1\"; perpendicular wall 14\" from the opening (spec sheet 900728-00 and manual p.5 clearance table), while manual Figure 5 is labeled 12\" from a perpendicular side wall - Superior prints both; no combustible trim or mantel within 9\" of the opening (6\" above the top louver), and combustibles projecting more than 1-1\/2\" at least 12\" above the top of the opening (manual p.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eSeasoned solid wood; approved for vented gas logs and vent-free gas log heaters (hood required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListing\u003c\/th\u003e\n\u003ctd\u003eUL 127 and CAN\/ULC-S610 factory-built fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox\u003c\/th\u003e\n\u003ctd\u003e34-3\/4 in. front width, 19-3\/8 in. rear width, 14-1\/2 in. deep, 21-1\/2 in. high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChimney\u003c\/th\u003e\n\u003ctd\u003eIHP 8DM double-wall, 8 in. ID \/ 12-3\/8 in. OD (8HT stainless in Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem height\u003c\/th\u003e\n\u003ctd\u003e14.5 ft minimum (straight or one elbow set), 22 ft minimum with two elbow sets, 50 ft maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHearth extension\u003c\/th\u003e\n\u003ctd\u003e16 in. in front and 8 in. past each side of the opening (52 x 16 in. extension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e150 lb (spec sheet 900728-00, WRT2036WSI and WCT2036WSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e20-year limited (see Warranty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFraming: 38-1\/4 in. W x 38-5\/8 in. H x 22 in. D (manual Figure 1, p.5; spec sheet 900728-00).\u003c\/li\u003e\n\u003cli\u003eFirebox: 34-3\/4 in. front width, 19-3\/8 in. rear width, 14-1\/2 in. deep, 21-1\/2 in. high (brochure).\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: back and sides 3\/4 in. (not needed at the nailing flanges), floor 0 in., top spacers 0 in., chimney outer pipe 1 in., perpendicular side wall 14 in. from the opening (p.5).\u003c\/li\u003e\n\u003cli\u003eNever pack the required air spaces with insulation or other material (p.5).\u003c\/li\u003e\n\u003cli\u003eHearth extension: non-combustible, at least 16 in. in front and 8 in. past each side of the opening (52 x 16 in. extension); a 1 in. layer needs k = 0.84 or less, and the gap to the fireplace is sealed with non-combustible material (pp.5-6).\u003c\/li\u003e\n\u003cli\u003eEmber protector: 28-gauge or heavier galvanized steel, extending at least 1-1\/2 in. under the front of the fireplace (p.5).\u003c\/li\u003e\n\u003cli\u003eMantels: no combustible trim or mantel within 9 in. of the opening (6 in. above the top louver); combustibles that project more than 1-1\/2 in. must be at least 12 in. above the top of the opening (p.6).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with white stacked refractory panels (radiant WRT or louvered WCT front, as selected)\u003c\/li\u003e\n\u003cli\u003eLog grate: the parts list (p.17) names J4001 Wood Burning Grate, and p.14 names IHP model 107001-01 as the replacement grate; Superior prints both numbers\u003c\/li\u003e\n\u003cli\u003eFire screens\u003c\/li\u003e\n\u003cli\u003eDamper and adjustable outside air damper\u003c\/li\u003e\n\u003cli\u003eInstallation and operation manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired (sold separately)\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIHP 8DM chimney (US) or 8HT chimney (required in Canada): pipe sections, termination cap, and the parts your route needs (pp.7-12).\u003c\/li\u003e\n\u003cli\u003eFirestop spacer 3600FS-8DM-1 at every floor or ceiling penetration, and a 38FST or FST30 firestop thimble where the chimney enters an attic (p.10).\u003c\/li\u003e\n\u003cli\u003eRoof flashing: choose one roof flashing to suit your roof pitch: V6F-8DM (0-6\/12 pitch) or V12F-8DM (6\/12-12\/12), with storm collar SC1 for round terminations (p.11); V6FS-8DM is the 24 in. base 0-6\/12 roof flashing for the same 8DM chimney.\u003c\/li\u003e\n\u003cli\u003eNon-combustible hearth extension (field-supplied) built to the manual (pp.5-6).\u003c\/li\u003e\n\u003cli\u003eGA6050 black fireplace hood (p.20): required only if a vent-free gas log set is installed (pp.1, 13, 20).\u003c\/li\u003e\n\u003cli\u003eCanada: 8HT stainless chimney parts and the CAK-8 cold air climate kit (p.15).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGlass doors: BDB36 (black), BDB36B (brushed brass) and BDB36P (platinum) bi-fold glass doors (p.19)\u003c\/li\u003e\n\u003cli\u003eOutside air kits: AK4 (F1091) for a sidewall run or AK4F (F1093) for a floor or vented crawl-space run (pp.7, 18-19)\u003c\/li\u003e\n\u003cli\u003eFan kit: BK fan kit for the circulating WCT model only, wired through the side cover plate with the three wire nuts supplied (pp.7, 20)\u003c\/li\u003e\n\u003cli\u003eGA6050 black fireplace hood (p.20) (wood burning)\u003c\/li\u003e\n\u003cli\u003eChimney offsets 30E-8DM \/ 30E-8HT and ceiling support 12S-8DM \/ 12S-8HT; anti-draft shield ADS-8DM for round tops (pp.8-11)\u003c\/li\u003e\n\u003cli\u003eRefractory stain kits BSK-CR Creamer (H8176), BSK-RT Rust (H8177) and BSK-CP Cappuccino (H8178) (p.18)\u003c\/li\u003e\n\u003cli\u003eVented gas log set listed to ANSI Z21.60\/CSA 2.26 or Z21.84, or vent-free gas log heater listed to ANSI Z21.11.2 (with the GA6050 hood)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e A wood fireplace that is installed, operated or maintained incorrectly can cause a house fire or carbon-monoxide exposure. This fireplace must be installed by a qualified professional following the Superior WRT\/WCT2036 installation manual (P\/N 126628-01 Rev. K), with only the listed IHP chimney components, and inspected by your local building official where required.\u003c\/p\u003e\u003ch4\u003eSafety\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eListed to UL 127 and CAN\/ULC-S610 as a factory-built fireplace for wood, vented gas logs and vent-free gas log heaters; never alter or modify the fireplace (p.1).\u003c\/li\u003e\n\u003cli\u003eBurn only dry, seasoned solid wood; never gasoline, lighter fluid, treated wood, trash, coal or charcoal. Overfiring can permanently damage the fireplace and is not covered by the warranty (pp.2-3).\u003c\/li\u003e\n\u003cli\u003eInspect the chimney at least twice a year and remove creosote at 1\/8 in.; keep ashes in a closed metal container on a non-combustible surface (p.3).\u003c\/li\u003e\n\u003cli\u003eKeep children and pets away from the hot opening; the fireplace is for supplemental heat only (pp.2-3).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eFraming 38-1\/4 in. W x 38-5\/8 in. H x 22 in. D (Figure 1, p.5; specification sheet P\/N 900728-00).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eFireplace installation: framing, clearances, hearth and mantel\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eClearances to combustibles: back and sides 3\/4 in. (not needed at the nailing flanges), floor 0 in., top spacers 0 in., chimney outer pipe 1 in., perpendicular side wall 14 in. from the opening (p.5).\u003c\/li\u003e\n\u003cli\u003eNever pack the required air spaces with insulation or other material (p.5).\u003c\/li\u003e\n\u003cli\u003eHearth extension: non-combustible, at least 16 in. in front and 8 in. past each side of the opening (52 x 16 in. extension); a 1 in. layer needs k = 0.84 or less, and the gap to the fireplace is sealed with non-combustible material (pp.5-6).\u003c\/li\u003e\n\u003cli\u003eEmber protector: 28-gauge or heavier galvanized steel, extending at least 1-1\/2 in. under the front of the fireplace (p.5).\u003c\/li\u003e\n\u003cli\u003eMantels: no combustible trim or mantel within 9 in. of the opening (6 in. above the top louver); combustibles that project more than 1-1\/2 in. must be at least 12 in. above the top of the opening (p.6).\u003c\/li\u003e\n\u003cli\u003eSet the fireplace square and plumb, shimming as needed so the optional glass doors align (p.1).\u003c\/li\u003e\n\u003cli\u003eFan kit: BK fan kit for the circulating WCT model only, wired through the side cover plate with the three wire nuts supplied (pp.7, 20); use only IHP fans.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting installation: chimney and outside air\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOutside air kits AK4\/AK4F go in during rough framing; never terminate the air inlet in an attic, and keep it no more than 3 ft below the flue gas outlet of the termination (p.7).\u003c\/li\u003e\n\u003cli\u003eUse only IHP 8DM (US) or 8HT stainless (Canada) chimney sections (12, 18, 24, 36 and 48 in. snap-lock); the installer applies label 900599-01 to every chimney pipe section except sections that stay visible after installation (p.7).\u003c\/li\u003e\n\u003cli\u003eSystem height: 14.5 ft minimum straight or with one elbow set, 22 ft minimum with two elbow sets, 6 ft maximum between elbows, 50 ft maximum; a chimney supported only by the fireplace may not exceed 20 ft (pp.5, 7-8).\u003c\/li\u003e\n\u003cli\u003eOffsets: 30E-8DM (30E-8HT) offset and return with 12S-8DM support; no more than 6 ft of angled run between supports and no more than two offsets; secure outer pipe joints with two screws and never pierce the inner pipe (pp.8-9).\u003c\/li\u003e\n\u003cli\u003eFirestop spacers 3600FS-8DM-1 at each floor or ceiling; a firestop thimble 38FST or FST30 where the chimney enters an attic (p.10).\u003c\/li\u003e\n\u003cli\u003eRoof: the pipe extends at least 30 in. above the roof cutout and the termination at least 36 in. above the roof; 10-foot rule: at least 3 ft above the roof penetration and 2 ft above any roof within 10 ft (pp.10-12).\u003c\/li\u003e\n\u003cli\u003eTerminations: round RT-8DM \/ RLT-8DM (RTT \/ RLTT with slip section) with flashing and storm collar, or square ET \/ ETO \/ ETL \/ ETLO for chases only; chase terminations at least 24 in. apart center to center and 18 in. offset vertically (pp.11-12).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eOptional gas line installation\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eRun a 1\/2 in. black iron gas line through the knockout, have a qualified person make the connection, and leak-test with soapy water, never a flame (p.13).\u003c\/li\u003e\n\u003cli\u003eVented gas logs must be listed to ANSI Z21.60\/CSA 2.26 or Z21.84; vent-free gas log heaters to ANSI Z21.11.2, and only with the GA6050 black fireplace hood installed (pp.1, 13, 20).\u003c\/li\u003e\n\u003cli\u003eWith vented gas logs, remove the damper or lock it fully open; never run an unvented log set with the chimney removed, and never cook in the fireplace (p.13).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eOperation and maintenance\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOpen the damper and the glass doors fully before lighting; operate doors only fully open or fully closed, warm the glass slowly, keep the fire away from it and never slam the doors (p.14).\u003c\/li\u003e\n\u003cli\u003eClean the glass with a non-abrasive cleaner, never cool water on hot glass; stop using the doors if the glass is damaged (p.14).\u003c\/li\u003e\n\u003cli\u003eReplace the grate only with IHP model 107001-01 (p.14); the parts list names J4001 Wood Burning Grate (p.17).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eReplacement parts, technical service and Canada\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOrder parts through an IHP dealer with the model, serial and part numbers (p.15).\u003c\/li\u003e\n\u003cli\u003eCanada: use 8HT stainless chimney parts and the cold air climate kit (also recommended in cold US regions), and check permit requirements with the local authority (pp.1, 15).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAccessories\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eListed accessories include the BDB36 glass doors, outside air kits AK4\/AK4F, fan kit, chimney sections, offsets, supports, firestops, flashings, storm collar, terminations, ADS-8DM, the hood and refractory stain kits (pp.18-20).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eAppendix A: draft and smoke guidelines\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eTarget draft is between 0.04 and 0.08 in. W.C.; negative house pressure (exhaust fans, tight homes) causes smoking, so provide make-up air (pp.21-22).\u003c\/li\u003e\n\u003cli\u003eWarm the flue before lighting; season softwood 6-18 months and hardwood 12-24 months to under 20% moisture; keep the chimney as straight as possible (p.22).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local building codes and the authority having jurisdiction (p.1).\u003c\/li\u003e\n\u003cli\u003eChimneys, fireplaces and draft: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-211-standard-development\/211\"\u003eNFPA 211 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances\u003c\/a\u003e (cited in the manual pp.6, 21).\u003c\/li\u003e\n\u003cli\u003eGas log connections: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e; in Canada, \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1 Natural Gas and Propane Installation Code\u003c\/a\u003e (p.13).\u003c\/li\u003e\n\u003cli\u003eFireplace listing: \u003ca href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL127\"\u003eUL 127 Factory-Built Fireplaces\u003c\/a\u003e and CAN\/ULC-S610 (Canada) (p.1).\u003c\/li\u003e\n\u003cli\u003eGas log listings: ANSI Z21.60 \/ Z21.84 (vented) and ANSI Z21.11.2 (vent-free gas log heaters) (p.1).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage: Superior Wood Burning Fireplace 20 Year Limited Warranty (P\/N 900224-00 Rev. B), printed in the installation manual (p.23).\u003c\/li\u003e\n\u003cli\u003eProduct body, firebox and ceramic glass: 20 years (ceramic glass against thermal breakage only).\u003c\/li\u003e\n\u003cli\u003eRefractory and screens: 2 years. Electrical components, cast iron and gaskets: 1 year. Optional glass doors and fuel grates: 90 days.\u003c\/li\u003e\n\u003cli\u003eLabor: paid at IHP's prevailing rates for up to five years.\u003c\/li\u003e\n\u003cli\u003eNot covered: vent components, trim, paint and applied stains.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner only; the warranty is not transferable.\u003c\/li\u003e\n\u003cli\u003eConditions: installed and repaired by an IHP-approved contractor following the manual and local codes, using only IHP components; modifications, non-IHP components and improper installation or maintenance void it.\u003c\/li\u003e\n\u003cli\u003eExclusions include overfiring and unapproved fuels (p.3).\u003c\/li\u003e\n\u003cli\u003eClaims: report the defect in writing within 90 days of the failure.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/126628-01_K_SUP_WRT2036_WCT2036_Series_Wood_Fireplace_IICO.pdf\"\u003eInstallation and Operation Manual (WRT\/WCT2036, P\/N 126628-01 Rev. K)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/900728-00_NC_SUP_WRT2036_WCT2036_Wood_Fireplace_SPEC.pdf\"\u003eSpecification Sheet (P\/N 900728-00)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/10\/785356M_WRTWCT2000_0725-WEB.pdf\"\u003eWRT\/WCT2000 Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2022\/04\/785847M-WRTWCT2000-Smart-Sheet-0725-WEB.pdf\"\u003eWRT\/WCT2000 Smart Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/127003-01_C_SUP_Wood_Homeowners_Guide_CO.pdf\"\u003eWood Fireplace Homeowner's Guide (P\/N 127003-01)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/785692M_Superior-GasLogs-0926-WEB.pdf\"\u003eSuperior Gas Logs Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including Carbon Black, which is known to the State of California to cause cancer, and Carbon Monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — WRT\/WCT2036\u003c\/h3\u003e\u003ch4\u003eWhat size framing does the WRT\/WCT2036 need?\u003c\/h4\u003e\u003cp\u003eThe framing dimensions are 38-1\/4 in. wide x 38-5\/8 in. high x 22 in. deep. Keep 3\/4 in. at the back and sides (not needed at the nailing flanges) and 0 in. at the floor and top spacers.\u003c\/p\u003e\u003ch4\u003eWhat chimney does it use, and how tall must it be?\u003c\/h4\u003e\u003cp\u003eOnly the IHP 8DM double-wall chimney, or the 8HT stainless chimney, which is required in Canada. The system needs 14.5 ft minimum straight or with one elbow set, 22 ft minimum with two elbow sets, and 50 ft maximum.\u003c\/p\u003e\u003ch4\u003eWhat is the difference between the WRT and WCT versions?\u003c\/h4\u003e\u003cp\u003eThe WRT2036WSI has a smooth radiant face. The WCT2036WSI has rolled louvers above and below the opening for heat circulation and is the only version that takes the BK fan kit (F1081).\u003c\/p\u003e\u003ch4\u003eCan I put gas logs in it?\u003c\/h4\u003e\u003cp\u003eYes. It is approved for vented decorative gas logs listed to ANSI Z21.60 or Z21.84, and for vent-free gas log heaters listed to ANSI Z21.11.2 only with the GA6050 black fireplace hood installed. With vented logs, the damper is removed or locked fully open.\u003c\/p\u003e\u003ch4\u003eDoes it need a hearth extension?\u003c\/h4\u003e\u003cp\u003eYes. A non-combustible hearth extension at least 16 in. in front and 8 in. past each side of the opening (52 x 16 in. on the manual's drawing); a 1 in. layer needs k = 0.84 or less.\u003c\/p\u003e\u003ch4\u003eAre glass doors available?\u003c\/h4\u003e\u003cp\u003eYes. The optional BDB36 black (F0972), BDB36B brushed brass (F0973) and BDB36P platinum (F0974) bi-fold glass doors fit this model.\u003c\/p\u003e","brand":"Superior","offers":[{"title":"Radiant","offer_id":50593238417570,"sku":"WRT2036WSI","price":1069.0,"currency_code":"USD","in_stock":true},{"title":"Louvered","offer_id":50593238450338,"sku":"WCT2036WSI","price":1129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/superior-2036-r16-00-main_pad.jpg?v=1795263511"},{"product_id":"superior-42-wood-burning-traditional-fireplace-wrt-wct2042","title":"Superior 42\" Wood-Burning Traditional Fireplace WRT\/WCT2042","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Superior WRT\/WCT2042 is the 42-inch model of the WRT\/WCT2000 Series, the value-priced entry into Superior's traditional wood-burning fireplaces. It is a factory-built, zero-clearance, open-hearth fireplace from Innovative Hearth Products that brings a real wood fire into a new home or remodel, framed with ordinary wood studs instead of site-built masonry.\u003c\/p\u003e\u003cp\u003eOne listing covers both front styles: the Radiant WRT has a clean, smooth face, while the Louvered WCT adds rolled louvers above and below the opening for heat circulation and accepts an optional fan kit. White stacked refractory panels give a traditional masonry look inside a textured powder-coat finish, and the fully insulated firebox helps in colder climates. Like every open-hearth wood fireplace, it is built for ambiance and supplemental heat.\u003c\/p\u003e\u003cp\u003eIt vents through the IHP 8 in. 8DM double-wall chimney (8HT stainless, required in Canada). Options include BDB42 bi-fold glass doors and AK4 \/ AK4F outside air kits, and it is approved for vented gas logs and, with the GA6050 hood, vent-free gas log heaters.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo sizes\u003c\/strong\u003e: 36 in. and 42 in. models; this is the 42 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiant or louvered front\u003c\/strong\u003e: smooth-faced WRT2042WSI or circulating rolled-louver WCT2042WSI, selectable on this listing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully insulated firebox\u003c\/strong\u003e: better performance in colder climates; firebox 38-7\/8 in. front width, 25-3\/8 in. rear, 14-1\/2 in. deep, 21-1\/2 in. high.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhite stacked refractory panels\u003c\/strong\u003e: traditional masonry look; refractory stain kits change the color.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLog grate and mesh fire screens included\u003c\/strong\u003e, with push\/pull damper control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutside air\u003c\/strong\u003e: barometric, adjustable outside air damper with optional AK4 (sidewall) or AK4F (floor\/crawl space) kits; gas line and outside air knockouts on the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas log ready\u003c\/strong\u003e: approved for vented gas logs (ANSI Z21.60 \/ Z21.84) and vent-free gas log heaters (ANSI Z21.11.2, GA6050 hood required).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit for the WCT\u003c\/strong\u003e: BK manual variable-speed fan kit (F1081) for the louvered model only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance installation\u003c\/strong\u003e: 3\/4 in. at the back and sides, 0 in. at the floor and top spacers; listed to UL 127 and CAN\/ULC-S610.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20-year limited warranty\u003c\/strong\u003e: Superior wood-burning fireplace warranty with labor paid up to five years.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eWRT2042WSI (radiant, smooth face) and WCT2042WSI (circulating, rolled louvers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eIndoor open-hearth, zero-clearance wood-burning fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003e44-1\/4\" W x 37-5\/8\" H x 22\" D (manual 126631-01 Figure 1 framing, p.5; spec sheet 900728-01 framing dimensions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eBack and sides 3\/4\" (not required at the nailing flanges); floor 0\"; top spacers 0\"; chimney outer pipe surface 1\"; perpendicular wall 12\" from the opening (spec sheet 900728-01; manual p.5); no combustible trim or mantel within 12\" of the opening (9\" above the top louver), and combustibles projecting more than 1-1\/2\" at least 12\" above the top of the opening (manual p.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eSeasoned solid wood; approved for vented gas logs and vent-free gas log heaters (hood required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListing\u003c\/th\u003e\n\u003ctd\u003eUL 127 and CAN\/ULC-S610 factory-built fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox\u003c\/th\u003e\n\u003ctd\u003e38-7\/8 in. front width, 25-3\/8 in. rear width, 14-1\/2 in. deep, 21-1\/2 in. high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChimney\u003c\/th\u003e\n\u003ctd\u003eIHP 8DM double-wall, 8 in. ID \/ 12-3\/8 in. OD (8HT stainless in Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem height\u003c\/th\u003e\n\u003ctd\u003e14.5 ft minimum (straight or one elbow set), 22 ft minimum with two elbow sets, 50 ft maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHearth extension\u003c\/th\u003e\n\u003ctd\u003e20 in. in front and 12 in. past each side of the opening (66 x 20 in. extension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e180 lb; 22.0 cu. ft. (spec sheet 900728-01, WRT2042WSI and WCT2042WSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e20-year limited (see Warranty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFraming: 44-1\/4 in. W x 37-5\/8 in. H x 22 in. D (manual Figure 1, p.5; spec sheet 900728-01).\u003c\/li\u003e\n\u003cli\u003eFirebox: 38-7\/8 in. front width, 25-3\/8 in. rear width, 14-1\/2 in. deep, 21-1\/2 in. high (brochure).\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: back and sides 3\/4 in. (not needed at the nailing flanges), floor 0 in., top spacers 0 in., chimney outer pipe 1 in., perpendicular side wall 12 in. from the opening (p.5).\u003c\/li\u003e\n\u003cli\u003eNever pack the required air spaces with insulation or other material (p.5).\u003c\/li\u003e\n\u003cli\u003eHearth extension: non-combustible, at least 20 in. in front and 12 in. past each side of the opening (66 x 20 in. extension); a 1 in. layer needs k = 0.84 or less, and the gap to the fireplace is sealed with non-combustible material (pp.5-6).\u003c\/li\u003e\n\u003cli\u003eEmber protector: 28-gauge or heavier galvanized steel, extending at least 1-1\/2 in. under the front of the fireplace (p.5).\u003c\/li\u003e\n\u003cli\u003eMantels: no combustible trim or mantel within 12 in. of the opening (9 in. above the top louver); combustibles that project more than 1-1\/2 in. must be at least 12 in. above the top of the opening (p.6).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with white stacked refractory panels (radiant WRT or louvered WCT front, as selected)\u003c\/li\u003e\n\u003cli\u003eLog grate: the parts list (p.17) names J4002 Wood Burning Grate, and p.14 names IHP model 107001-02 as the replacement grate; Superior prints both numbers\u003c\/li\u003e\n\u003cli\u003eFire screens\u003c\/li\u003e\n\u003cli\u003eDamper and adjustable outside air damper\u003c\/li\u003e\n\u003cli\u003eInstallation and operation manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired (sold separately)\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIHP 8DM chimney (US) or 8HT chimney (required in Canada): pipe sections, termination cap, and the parts your route needs (pp.7-12).\u003c\/li\u003e\n\u003cli\u003eFirestop spacer 3600FS-8DM-1 at every floor or ceiling penetration, and a 38FST or FST30 firestop thimble where the chimney enters an attic (p.10).\u003c\/li\u003e\n\u003cli\u003eRoof flashing: choose one roof flashing to suit your roof pitch: V6F-8DM (0-6\/12 pitch) or V12F-8DM (6\/12-12\/12), with storm collar SC1 for round terminations (p.11); V6FS-8DM is the 24 in. base 0-6\/12 roof flashing for the same 8DM chimney.\u003c\/li\u003e\n\u003cli\u003eNon-combustible hearth extension (field-supplied) built to the manual (pp.5-6).\u003c\/li\u003e\n\u003cli\u003eGA6050 black fireplace hood (p.20): required only if a vent-free gas log set is installed (pp.1, 13, 20).\u003c\/li\u003e\n\u003cli\u003eCanada: 8HT stainless chimney parts and the CAK-8 cold air climate kit (p.15).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGlass doors: BDB42 black (F0975), BDB42B brushed brass (F0976) and BDB42P platinum (F0977) bi-fold glass doors (p.19)\u003c\/li\u003e\n\u003cli\u003eOutside air kits: AK4 (F1091) for a sidewall run or AK4F (F1093) for a floor or vented crawl-space run (pp.7, 18-19)\u003c\/li\u003e\n\u003cli\u003eFan kit: BK manual variable-speed fan kit (F1081) for the circulating WCT model only, run from a rocker switch with a speed control knob (pp.7, 17, 19)\u003c\/li\u003e\n\u003cli\u003eGA6050 black fireplace hood (p.20) (wood burning)\u003c\/li\u003e\n\u003cli\u003eChimney offsets 30E-8DM \/ 30E-8HT and ceiling support 12S-8DM \/ 12S-8HT; anti-draft shield ADS-8DM for round tops (pp.8-11)\u003c\/li\u003e\n\u003cli\u003eRefractory stain kits BSK-CR Creamer (H8176), BSK-RT Rust (H8177) and BSK-CP Cappuccino (H8178) (p.18)\u003c\/li\u003e\n\u003cli\u003eVented gas log set listed to ANSI Z21.60\/CSA 2.26 or Z21.84, or vent-free gas log heater listed to ANSI Z21.11.2 (with the GA6050 hood)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e A wood fireplace that is installed, operated or maintained incorrectly can cause a house fire or carbon-monoxide exposure. This fireplace must be installed by a qualified professional following the Superior WRT\/WCT2042 installation manual (P\/N 126631-01 Rev. J), with only the listed IHP chimney components, and inspected by your local building official where required.\u003c\/p\u003e\u003ch4\u003eSafety\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eListed to UL 127 and CAN\/ULC-S610 as a factory-built fireplace for wood, vented gas logs and vent-free gas log heaters; never alter or modify the fireplace (p.1).\u003c\/li\u003e\n\u003cli\u003eBurn only dry, seasoned solid wood; never gasoline, lighter fluid, treated wood, trash, coal or charcoal. Overfiring can permanently damage the fireplace and is not covered by the warranty (pp.2-3).\u003c\/li\u003e\n\u003cli\u003eInspect the chimney at least twice a year and remove creosote at 1\/8 in.; keep ashes in a closed metal container on a non-combustible surface (p.3).\u003c\/li\u003e\n\u003cli\u003eKeep children and pets away from the hot opening; the fireplace is for supplemental heat only (pp.2-3).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eFraming 44-1\/4 in. W x 37-5\/8 in. H x 22 in. D (Figure 1, p.5; specification sheet P\/N 900728-01).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eFireplace installation: framing, clearances, hearth and mantel\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eClearances to combustibles: back and sides 3\/4 in. (not needed at the nailing flanges), floor 0 in., top spacers 0 in., chimney outer pipe 1 in., perpendicular side wall 12 in. from the opening (p.5).\u003c\/li\u003e\n\u003cli\u003eNever pack the required air spaces with insulation or other material (p.5).\u003c\/li\u003e\n\u003cli\u003eHearth extension: non-combustible, at least 20 in. in front and 12 in. past each side of the opening (66 x 20 in. extension); a 1 in. layer needs k = 0.84 or less, and the gap to the fireplace is sealed with non-combustible material (pp.5-6).\u003c\/li\u003e\n\u003cli\u003eEmber protector: 28-gauge or heavier galvanized steel, extending at least 1-1\/2 in. under the front of the fireplace (p.5).\u003c\/li\u003e\n\u003cli\u003eMantels: no combustible trim or mantel within 12 in. of the opening (9 in. above the top louver); combustibles that project more than 1-1\/2 in. must be at least 12 in. above the top of the opening (p.6).\u003c\/li\u003e\n\u003cli\u003eSet the fireplace square and plumb, shimming as needed so the optional glass doors align (p.1).\u003c\/li\u003e\n\u003cli\u003eFan kit: BK manual variable-speed fan kit (F1081) for the circulating WCT model only, run from a rocker switch with a speed control knob (pp.7, 17, 19); use only IHP fans.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting installation: chimney and outside air\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOutside air kits AK4\/AK4F go in during rough framing; never terminate the air inlet in an attic, and keep it no more than 3 ft below the flue gas outlet of the termination (p.7).\u003c\/li\u003e\n\u003cli\u003eUse only IHP 8DM (US) or 8HT stainless (Canada) chimney sections (12, 18, 24, 36 and 48 in. snap-lock); the installer applies label 900599-01 to every chimney pipe section except sections that stay visible after installation (p.7).\u003c\/li\u003e\n\u003cli\u003eSystem height: 14.5 ft minimum straight or with one elbow set, 22 ft minimum with two elbow sets, 6 ft maximum between elbows, 50 ft maximum; a chimney supported only by the fireplace may not exceed 20 ft (pp.5, 7-8).\u003c\/li\u003e\n\u003cli\u003eOffsets: 30E-8DM (30E-8HT) offset and return with 12S-8DM support; no more than 6 ft of angled run between supports and no more than two offsets; secure outer pipe joints with two screws and never pierce the inner pipe (pp.8-9).\u003c\/li\u003e\n\u003cli\u003eFirestop spacers 3600FS-8DM-1 at each floor or ceiling; a firestop thimble 38FST or FST30 where the chimney enters an attic (p.10).\u003c\/li\u003e\n\u003cli\u003eRoof: the pipe extends at least 30 in. above the roof cutout and the termination at least 36 in. above the roof; 10-foot rule: at least 3 ft above the roof penetration and 2 ft above any roof within 10 ft (pp.10-12).\u003c\/li\u003e\n\u003cli\u003eTerminations: round RT-8DM \/ RLT-8DM (RTT \/ RLTT with slip section) with flashing and storm collar, or square ET \/ ETO \/ ETL \/ ETLO for chases only; chase terminations at least 24 in. apart center to center and 18 in. offset vertically (pp.11-12).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eOptional gas line installation\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eRun a 1\/2 in. black iron gas line through the knockout, have a qualified person make the connection, and leak-test with soapy water, never a flame (p.13).\u003c\/li\u003e\n\u003cli\u003eVented gas logs must be listed to ANSI Z21.60\/CSA 2.26 or Z21.84; vent-free gas log heaters to ANSI Z21.11.2, and only with the GA6050 black fireplace hood installed (pp.1, 13, 20).\u003c\/li\u003e\n\u003cli\u003eWith vented gas logs, remove the damper or lock it fully open; never run an unvented log set with the chimney removed, and never cook in the fireplace (p.13).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eOperation and maintenance\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOpen the damper and the glass doors fully before lighting; operate doors only fully open or fully closed, warm the glass slowly, keep the fire away from it and never slam the doors (p.14).\u003c\/li\u003e\n\u003cli\u003eClean the glass with a non-abrasive cleaner, never cool water on hot glass; stop using the doors if the glass is damaged (p.14).\u003c\/li\u003e\n\u003cli\u003eReplace the grate only with IHP model 107001-02 (p.14); the parts list names J4002 Wood Burning Grate (p.17).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eReplacement parts, technical service and Canada\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOrder parts through an IHP dealer with the model, serial and part numbers (p.15).\u003c\/li\u003e\n\u003cli\u003eCanada: use 8HT stainless chimney parts and the cold air climate kit (also recommended in cold US regions), and check permit requirements with the local authority (pp.1, 15).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAccessories\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eListed accessories include the BDB42 glass doors, outside air kits AK4\/AK4F, fan kit, chimney sections, offsets, supports, firestops, flashings, storm collar, terminations, ADS-8DM, the hood and refractory stain kits (pp.18-20).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eAppendix A: draft and smoke guidelines\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eTarget draft is between 0.04 and 0.08 in. W.C.; negative house pressure (exhaust fans, tight homes) causes smoking, so provide make-up air (pp.21-22).\u003c\/li\u003e\n\u003cli\u003eWarm the flue before lighting; season softwood 6-18 months and hardwood 12-24 months to under 20% moisture; keep the chimney as straight as possible (p.22).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local building codes and the authority having jurisdiction (p.1).\u003c\/li\u003e\n\u003cli\u003eChimneys, fireplaces and draft: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-211-standard-development\/211\"\u003eNFPA 211 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances\u003c\/a\u003e (cited in the manual pp.6, 21).\u003c\/li\u003e\n\u003cli\u003eGas log connections: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e; in Canada, \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1 Natural Gas and Propane Installation Code\u003c\/a\u003e (p.13).\u003c\/li\u003e\n\u003cli\u003eFireplace listing: \u003ca href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL127\"\u003eUL 127 Factory-Built Fireplaces\u003c\/a\u003e and CAN\/ULC-S610 (Canada) (p.1).\u003c\/li\u003e\n\u003cli\u003eGas log listings: ANSI Z21.60 \/ Z21.84 (vented) and ANSI Z21.11.2 (vent-free gas log heaters) (p.1).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage: Superior Wood Burning Fireplace 20 Year Limited Warranty, printed in the installation manual (pp.23-24).\u003c\/li\u003e\n\u003cli\u003eProduct body, firebox and ceramic glass: 20 years (ceramic glass against thermal breakage only).\u003c\/li\u003e\n\u003cli\u003eRemovable air tubes: 7 years. Screens, refractory and side shields: 2 years (hairline cracks excluded).\u003c\/li\u003e\n\u003cli\u003eAir tubes, baffles, brick retainers, cast iron, electrical components and gaskets: 1 year. Fuel grates and optional glass doors: 90 days. Parts not listed: 90 days.\u003c\/li\u003e\n\u003cli\u003eLabor: paid at IHP's prevailing rates for up to five years.\u003c\/li\u003e\n\u003cli\u003eNot covered: vent components, trim and paint.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner only; not transferable. Coverage starts at purchase or, in new construction, at first occupancy or six months after sale, whichever is earlier, and no later than 24 months after shipment.\u003c\/li\u003e\n\u003cli\u003eConditions: installed by an IHP-approved licensed contractor following the manual and codes, using only IHP components.\u003c\/li\u003e\n\u003cli\u003eClaims: report the defect in writing within 90 days of the failure.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/126631-01_J_SUP_WRT2042_WCT2042_Series_Wood_Fireplace_IICO.pdf\"\u003eInstallation and Operation Manual (WRT\/WCT2042, P\/N 126631-01 Rev. J)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/900728-01_NC_SUP_WRT2042_WCT2042_Wood_Fireplace_SPEC.pdf\"\u003eSpecification Sheet (P\/N 900728-01)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/10\/785356M_WRTWCT2000_0725-WEB.pdf\"\u003eWRT\/WCT2000 Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2022\/04\/785847M-WRTWCT2000-Smart-Sheet-0725-WEB.pdf\"\u003eWRT\/WCT2000 Smart Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/127003-01_C_SUP_Wood_Homeowners_Guide_CO.pdf\"\u003eWood Fireplace Homeowner's Guide (P\/N 127003-01)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/785692M_Superior-GasLogs-0926-WEB.pdf\"\u003eSuperior Gas Logs Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including Carbon Black, which is known to the State of California to cause cancer, and Carbon Monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — WRT\/WCT2042\u003c\/h3\u003e\u003ch4\u003eWhat size framing does the WRT\/WCT2042 need?\u003c\/h4\u003e\u003cp\u003eThe framing dimensions are 44-1\/4 in. wide x 37-5\/8 in. high x 22 in. deep. Keep 3\/4 in. at the back and sides (not needed at the nailing flanges) and 0 in. at the floor and top spacers.\u003c\/p\u003e\u003ch4\u003eWhat chimney does it use, and how tall must it be?\u003c\/h4\u003e\u003cp\u003eOnly the IHP 8DM double-wall chimney, or the 8HT stainless chimney, which is required in Canada. The system needs 14.5 ft minimum straight or with one elbow set, 22 ft minimum with two elbow sets, and 50 ft maximum.\u003c\/p\u003e\u003ch4\u003eWhat is the difference between the WRT and WCT versions?\u003c\/h4\u003e\u003cp\u003eThe WRT2042WSI has a smooth radiant face. The WCT2042WSI has rolled louvers above and below the opening for heat circulation and is the only version that takes the BK fan kit (F1081).\u003c\/p\u003e\u003ch4\u003eCan I put gas logs in it?\u003c\/h4\u003e\u003cp\u003eYes. It is approved for vented decorative gas logs listed to ANSI Z21.60 or Z21.84, and for vent-free gas log heaters listed to ANSI Z21.11.2 only with the GA6050 black fireplace hood installed. With vented logs, the damper is removed or locked fully open.\u003c\/p\u003e\u003ch4\u003eDoes it need a hearth extension?\u003c\/h4\u003e\u003cp\u003eYes. A non-combustible hearth extension at least 20 in. in front and 12 in. past each side of the opening (66 x 20 in. on the manual's drawing); a 1 in. layer needs k = 0.84 or less.\u003c\/p\u003e\u003ch4\u003eAre glass doors available?\u003c\/h4\u003e\u003cp\u003eYes. The optional BDB42 black (F0975), BDB42B brushed brass (F0976) and BDB42P platinum (F0977) bi-fold glass doors fit this model.\u003c\/p\u003e","brand":"Superior","offers":[{"title":"Radiant","offer_id":50593238483106,"sku":"WRT2042WSI","price":1249.0,"currency_code":"USD","in_stock":true},{"title":"Louvered","offer_id":50593238515874,"sku":"WCT2042WSI","price":1299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/superior-2042-r16-01-main_pad.jpg?v=1795263511"},{"product_id":"superior-50-wood-burning-traditional-fireplace-wrt6050","title":"Superior 50\" Wood-Burning Traditional Fireplace WRT6050","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Superior WRT6050 is the 50-inch, largest of the three WRT6000 Series traditional open-hearth wood-burning fireplaces from Innovative Hearth Products, sharing its design and manual with the 36 and 42-inch models. It gives the crackle, smell and glow of a real wood fire with the look of site-built masonry, in a factory-built, zero-clearance unit that installs in ordinary wood framing without masonry's weight, cost and construction time, with the widest fire, for a great room or large custom space.\u003c\/p\u003e\u003cp\u003eMosaic Masonry kiln-fired firebrick (one set required, sold separately) lines the firebox in Ivory, Midnight, Slate Grey or Warm Red, in full or split stacked and herringbone patterns, under a massive smoke dome with no visible smoke shelf. The clean face and textured powder-coat exterior take the stone, tile or other non-combustible facing of your choice.\u003c\/p\u003e\u003cp\u003eLike any open hearth it is made for ambiance and supplemental heat rather than as a primary heater. Optional bi-fold glass doors add safety, and it is also approved for vented and vent-free gas logs. It vents through the IHP 12-inch 12DM chimney (12HT stainless in Canada), 16 to 50 ft tall. Choose the size by wall width and the scale of fire you want.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree sizes\u003c\/strong\u003e: 36, 42 and 50-inch models; this is the 50-inch model, with a 50 in. wide x 30 in. tall opening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMassive smoke dome\u003c\/strong\u003e: with no visible smoke shelf, for a dependable draft and reliable operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMosaic Masonry firebrick\u003c\/strong\u003e: Ivory, Midnight, Slate Grey or Warm Red in four patterns (one set required), with an integrated ash lip for a clean hearth edge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully insulated firebox\u003c\/strong\u003e: increased performance in colder climates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard equipment\u003c\/strong\u003e: heavy-duty steel grate with rugged forged andirons, mesh fire screens and an easy-access damper control at the top of the opening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional glass doors\u003c\/strong\u003e: Mosaic masonry bi-fold doors (F1020 ebony, F1021 pewter, F1022 oiled bronze) for improved safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional gas log sets\u003c\/strong\u003e: approved for vented (ANSI Z21.60\/Z21.84) and vent-free (ANSI Z21.11.2) gas logs, for the charm of a wood fire with the convenience of gas; Superior offers Granite Ridge, Silverstone Timber, Mossy Oak and Giant Timbers sets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual outside air kits available\u003c\/strong\u003e: left- and right-hand kits for maximum performance (two highly recommended).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean-face, zero-clearance design\u003c\/strong\u003e: durable textured powder-coat finish; installs in standard framing with 1-1\/2 in. back and side clearance and 0 in. at the top spacers and floor, with a non-combustible hearth extension in front; IHP 12DM chimney, or 12HT stainless required for Canada.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed, 20-year limited warranty\u003c\/strong\u003e: UL 127 and CAN\/ULC-S610 factory-built fireplace (PFS report F09-095); 20 years on the product body and firebox.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eWRT6050 fireplace box (catalog F4221); Mosaic firebrick ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eSuperior WRT6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eTraditional open-hearth wood-burning fireplace, front view, factory-built (zero clearance), clean face\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e59-1\/4\" W x 67\" H x 28-1\/2\" D overall (1505 x 1702 x 724 mm); 38-1\/2\" across the back (manual Fig. 3, p.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003e59-3\/4\" W x 67-1\/8\" H x 30-1\/8\" D (1518 x 1705 x 766 mm; manual Fig. 4, p.7; spec sheet 901007-01); corner: 71\" along each wall, 100\" across the front (Fig. 5, p.7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e50\" W x 30\" H fireplace opening (1270 x 762 mm), starting 7\" above the base (manual Fig. 3, p.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eBack and sides 1-1\/2\" (not required at the nailing flanges); top spacers 0\"; floor 0\"; ceiling 42\"; front 48\"; chimney outer pipe 2\"; perpendicular side wall 18\" from the opening; combustible trim or mantel 18\" from the opening, projections over 1-1\/2\" at least 21\" above the opening; mantel legs within the 33-degree safe zone: up to 11-1\/2\" projection at 18\" from the side of the opening, nothing combustible over the 4-1\/2\" metal front face (Fig. 7); non-combustible hearth extension 20\" in front and 12\" past each side (manual pp.7-8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHearth extension\u003c\/th\u003e\n\u003ctd\u003e74 x 20 in. minimum (manual pp.4-6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChimney\u003c\/th\u003e\n\u003ctd\u003eIHP 12 in. 12DM double-wall (US); 12HT stainless (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChimney height\u003c\/th\u003e\n\u003ctd\u003e16 ft minimum (22 ft with two offset sets); 50 ft maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eSolid seasoned wood; approved for vented and vent-free gas logs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded\u003c\/th\u003e\n\u003ctd\u003eSteel grate with andirons, mesh screens, damper, ember protector (firebrick sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e750 lb box (spec sheet 901007-01); Mosaic firebrick ships separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListing\u003c\/th\u003e\n\u003ctd\u003eUL 127 \/ CAN\/ULC-S610, PFS report F09-095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e20-year limited (body and firebox)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFraming: 67-1\/8 in. high x 59-3\/4 in. wide x 30-1\/8 in. deep (manual Fig. 4, p.7; spec sheet 901007-01).\u003c\/li\u003e\n\u003cli\u003eFireplace: 59-1\/4 in. wide x 67 in. high x 28-1\/2 in. deep, 38-1\/2 in. across the back; opening 50 in. wide x 30 in. high, 7 in. above the base (manual Fig. 3, p.6).\u003c\/li\u003e\n\u003cli\u003eCorner framing: 71 in. along each wall from the corner and 100 in. across the front between the walls (manual Fig. 5, p.7).\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: back and sides 1-1\/2 in. (not required at the nailing flanges); top spacers 0 in.; floor 0 in.; ceiling 42 in.; 48 in. in front of the fireplace; chimney outer pipe 2 in.; a perpendicular side wall 18 in. from the opening. Do not pack the air spaces with insulation (p.7).\u003c\/li\u003e\n\u003cli\u003eHearth extension: non-combustible, at least 20 in. in front of the opening and 12 in. beyond each side (74 x 20 in. for this size), with a thermal conductivity (k) of 0.84 BTU-in\/ft2-hr-°F or less at 1 in. thick; seal the gap to the fireplace with non-combustible material and use the supplied ember protector (pp.4-8).\u003c\/li\u003e\n\u003cli\u003eMantels and trim: combustible trim or a mantel projecting from the face must stay at least 18 in. from the opening; combustibles that project more than 1-1\/2 in. must be at least 21 in. above the top of the opening; mantel legs may project up to 11-1\/2 in. at 18 in. from the side of the opening, tapering along a 33-degree line toward it, and combustibles must not overlap the 4-1\/2 in. metal front face (Fig. 7, p.8).\u003c\/li\u003e\n\u003cli\u003eCombustible materials may reach the side edge of the black metal face but may not overlap the face; non-combustible facing may overlap if it blocks no openings, set with non-combustible mortar or adhesive only (pp.8, 15).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWRT6050 fireplace with fully insulated firebox and damper with easy-access control\u003c\/li\u003e\n\u003cli\u003eFirebox prepared for the Mosaic firebrick kit (see Required)\u003c\/li\u003e\n\u003cli\u003eHeavy-duty steel grate with forged andirons (J4345)\u003c\/li\u003e\n\u003cli\u003eMesh fire screens\u003c\/li\u003e\n\u003cli\u003eEmber protector J6906 (2 pieces) for the hearth extension joint\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired (sold separately)\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eChimney: IHP 12DM in the US (12HT stainless in Canada) - pipe sections for at least 16 ft (22 ft with two offset sets), a termination (round top RLT-12D, or square chase top STL-12D \/ STL-12DMP; Canada RLT-12HT), firestop spacers FS-10 at each floor or ceiling (with an FST10 thimble where the chimney enters an attic), and roof flashing V6F-10DM or V12F-10DM with storm collar SC2-1 when the chimney passes through a roof\u003c\/li\u003e\n\u003cli\u003eChimney support 12S-12DM (12S-12HT in Canada) when more than 20 ft of chimney would rest on the fireplace, and with offsets\u003c\/li\u003e\n\u003cli\u003eCanada: cold air collar kit CAK-12 (also recommended in cold US regions)\u003c\/li\u003e\n\u003cli\u003eOne Mosaic Masonry 50 in. firebrick kit (required): Ivory, Midnight, Slate Grey or Warm Red, full or split stacked or herringbone (Mosaic50... catalog F0334-F4544 range, spec sheet); plus non-combustible hearth extension material (by the installer)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e50 in. Mosaic masonry bi-fold glass doors: ebony F1020, pewter F1021, oiled bronze F1022\u003c\/li\u003e\n\u003cli\u003eOutside combustion air kits: AK4 (F1091, collars, hood and 3 ft flex), AK4F (F1093, for floor venting), AK4X (collar and hood only) - two kits highly recommended\u003c\/li\u003e\n\u003cli\u003e30-degree offset and return with adapter 30E-12DM-B (F5169; Canada 30E-12HT-B)\u003c\/li\u003e\n\u003cli\u003eUL127 chimney label pack F2659 (50)\u003c\/li\u003e\n\u003cli\u003eVented or vent-free gas log set listed for this fireplace (Superior Granite Ridge, Silverstone Timber, Mossy Oak or Giant Timbers)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eProduct video\u003c\/h3\u003e\u003cp\u003eOfficial Superior video for the WRT6000 Series (shown with an optional Mossy Oak gas log set):\u003c\/p\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/5ZG41o98_Nk\" title=\"Mossy Oak in WRT6000 Burn Video\" frameborder=\"0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e A wood fireplace that is installed, operated or maintained incorrectly can cause a house fire or carbon-monoxide exposure. This fireplace must be installed by a qualified professional following the Superior WRT6036\/42\/50 installation manual (P\/N 901007-00 Rev. F), with only the listed IHP chimney components, and inspected by your local building official where required.\u003c\/p\u003e\u003ch4\u003eSafety\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eListed to UL 127 and CAN\/ULC-S610 (report F09-095) as a factory-built fireplace for wood, vented gas logs and vent-free gas log heaters (p.1).\u003c\/li\u003e\n\u003cli\u003eNever alter or modify the fireplace or its components; overfiring (scrap lumber, pine branches, cardboard, trash, treated wood) can permanently damage it and is not covered by the warranty (pp.1, 3).\u003c\/li\u003e\n\u003cli\u003eInspect the chimney at least twice each heating season and remove creosote once it reaches 1\/8 in.; know the flu-like early signs of carbon monoxide (p.3).\u003c\/li\u003e\n\u003cli\u003eKeep children and pets away from the hot opening and screen; the fireplace is for supplemental heat only (p.2).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eFraming 67-1\/8 x 59-3\/4 x 30-1\/8 in.; hearth extension 74 x 20 in.; box shipping weight 750 lb (pp.4-7; spec sheet).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eFireplace installation: location, framing and clearances\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eClearances: back and sides 1-1\/2 in., top spacers and floor 0 in., ceiling 42 in., front 48 in., chimney 2 in., 18 in. to a perpendicular side wall (p.7).\u003c\/li\u003e\n\u003cli\u003eNon-combustible hearth extension at least 20 in. deep and 12 in. past each side of the opening; a raised platform needs a field-made Z-type ember protector of 28-gauge or heavier galvanized steel (p.8).\u003c\/li\u003e\n\u003cli\u003eMantels: combustible trim 18 in. from the opening; projections over 1-1\/2 in. at least 21 in. above the opening (p.8).\u003c\/li\u003e\n\u003cli\u003eManufactured homes: keep the floor, wall and ceiling\/roof structure intact, and never install in a sleeping room of a mobile home (p.10).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting installation: outside air and chimney\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eTwo outside air kits are highly recommended; never terminate the air duct in an attic, and keep the air inlet no more than 3 ft below the chimney flue outlet (p.9).\u003c\/li\u003e\n\u003cli\u003eUse only IHP 12DM (US) or 12HT stainless (Canada) chimney components; label visible sections with label 900599-01 (p.9).\u003c\/li\u003e\n\u003cli\u003eMinimum system height 16 ft straight or with one elbow set, 22 ft with two; 50 ft maximum; a chimney supported only by the fireplace may not exceed 20 ft (pp.7, 9-10).\u003c\/li\u003e\n\u003cli\u003eOffsets: 30-degree offset\/return, a maximum of two offsets, 6 ft maximum angled run between supports, at least one 12S-12DM (12S-12HT) support; secure offset joints with two screws in the outer pipe only (pp.10, 27-28).\u003c\/li\u003e\n\u003cli\u003eFirestop spacers at every floor penetration; a firestop and thimble where the chimney enters an attic to keep insulation away (p.11).\u003c\/li\u003e\n\u003cli\u003eAt the roof the chimney must extend at least 36 in. above the highest point where it passes through the roof and 30 in. above the roof cutout; use flashing V6F-10DM (0-6\/12) or V12F-10DM (6\/12-12\/12) with storm collar SC2-1 (pp.11-12, 25).\u003c\/li\u003e\n\u003cli\u003e10-foot rule: the top must be at least 3 ft above the roof penetration and 2 ft above any roof surface within 10 ft (p.13).\u003c\/li\u003e\n\u003cli\u003eChases: shortest vertical side at least 30 in., 19 in. minimum inside; square tops end within 6 in. of the chase top, round tops at least 6 in. above it; multiple terminations 24 in. apart and 18 in. offset vertically; never seal flashing ventilation openings (pp.13-14).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinishing the fireplace\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eCombustible materials may not overlap the face; non-combustible facing may overlap with non-combustible mortar or adhesive only (p.15).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eMosaic brick panel installation\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall the required Mosaic firebrick kit after the fireplace is in its permanent location, following the kit instructions (pp.16-17).\u003c\/li\u003e\n\u003cli\u003eUse only the IHP grate listed for this size (J4345) with its two retainers (p.22).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eOptional gas line installation\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVented gas logs must be listed to ANSI Z21.60 or Z21.84 and installed per NFPA 54; vent-free gas log heaters must be listed to ANSI Z21.11.2 (p.18).\u003c\/li\u003e\n\u003cli\u003eUse a 1\/2 in. black iron gas line and leak-test with soapy water, never a flame; clean the firebox and chimney of soot, creosote and ash before converting to gas (pp.18-19).\u003c\/li\u003e\n\u003cli\u003eWith vented gas logs the damper must be removed or locked fully open and the glass doors fully open; never run an unvented gas log with the chimney removed (pp.18-19).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eOperation and maintenance guidelines\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eLock the damper fully open and open the glass doors before lighting; operate the doors only fully open or fully closed, let the glass warm slowly and never clean hot glass with cool water (p.19).\u003c\/li\u003e\n\u003cli\u003eBurn only dry, seasoned solid wood under 20% moisture (softwood 6-18 months, hardwood 12-24 months); never gasoline, lighter fluid, treated wood or trash (pp.3-4).\u003c\/li\u003e\n\u003cli\u003eAppendix A gives draft and smoke guidelines: a draft reading of 0.04-0.08 in. W.C. and as few offsets as possible (pp.27-28).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAccessories\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eMosaic glass doors F1020\/F1021\/F1022, outside air kits AK4\/AK4F, chimney parts 12DM\/12HT, offsets 30E-12DM-B\/30E-12HT-B, supports 12S-12DM\/12S-12HT, firestop FS-10, thimble FST10, flashings V6F-10DM\/V12F-10DM, storm collar SC2-1, terminations RLT-12D\/RLT-12HT\/STL-12D\/STL-12DMP, Mosaic firebrick kits (pp.23-25).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eImportant notices for Canada\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eCheck with the authority having jurisdiction first; Canadian code requires a stainless chimney, so use the 12HT parts together with the CAK-12 cold air collar kit (AP-12HT anchor plate where called for) (pp.1, 9, 26).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local building codes and the authority having jurisdiction.\u003c\/li\u003e\n\u003cli\u003eChimneys, fireplaces and venting: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-211-standard-development\/211\"\u003eNFPA 211 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances\u003c\/a\u003e (mantels and draft, cited in the manual pp.8, 27).\u003c\/li\u003e\n\u003cli\u003eGas logs: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e (p.18).\u003c\/li\u003e\n\u003cli\u003eFireplace listing: \u003ca href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL127\"\u003eUL 127 Factory-Built Fireplaces\u003c\/a\u003e and CAN\/ULC-S610 (Canada).\u003c\/li\u003e\n\u003cli\u003eGas log listings: ANSI Z21.60 \/ Z21.84 (vented) and ANSI Z21.11.2 (vent-free gas log heaters).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage: Superior wood-burning fireplace 20 Year Limited Warranty (P\/N 900224-00 Rev. B), printed in the installation manual (P\/N 901007-00, p.29).\u003c\/li\u003e\n\u003cli\u003eProduct body and firebox: 20 years from installation. Ceramic glass: thermal breakage only.\u003c\/li\u003e\n\u003cli\u003eRemovable air tubes: 7 years. Refractory, side shields and screens: 2 years (hairline cracks excluded). Gold and nickel plating: 2 years (tarnishing excluded).\u003c\/li\u003e\n\u003cli\u003eAir tubes, baffles, brick retainers, cast-iron parts, gaskets and electrical components: 1 year. Optional glass doors: 90 days. Fuel grates: 90 days (defects only). Parts not listed: 90 days.\u003c\/li\u003e\n\u003cli\u003eVent components, trim, paint and applied stains are not covered by the 20-year term.\u003c\/li\u003e\n\u003cli\u003eLabor: paid at IHP's prevailing rates during each component's warranty period, up to five years.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner only (not transferable), bought from a listed IHP supplier with proof of purchase, installed in the US or Canada.\u003c\/li\u003e\n\u003cli\u003eConditions: installed and repaired by a licensed, IHP-approved contractor to codes, using only the chimney components specified in the manual, and operated and maintained per the instructions.\u003c\/li\u003e\n\u003cli\u003eExclusions: normal wear; accident, fire or flood; abuse, negligence or alteration; overfiring and unapproved fuels; lack of maintenance; faulty installation; draft or smoking problems from HVAC, chimney height, trees, buildings or wind; incidental damages.\u003c\/li\u003e\n\u003cli\u003eClaims: contact the selling dealer; if that is not possible, notify IHP in writing within 90 days of the failure.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/901007-00_F_SUP_WRT60364250_WB_Masonry_FP_IICO.pdf\"\u003eInstallation and Operation Manual (WRT6036\/42\/50, P\/N 901007-00)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/901007-01_A_SUP_WRT60_364250_ID_WB_Masonry_FP_SPEC.pdf\"\u003eSpecification Sheet (WRT6036\/42\/50, P\/N 901007-01)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/785352M_WRT6000_0326-WEB.pdf\"\u003eWRT6000 Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2022\/05\/785581M-WRT6000-Smart-Sheet-0326-WEB.pdf\"\u003eWRT6000 Smart Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/127003-01_C_SUP_Wood_Homeowners_Guide_CO.pdf\"\u003eWood Fireplace Homeowner's Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/785692M_Superior-GasLogs-0926-WEB.pdf\"\u003eSuperior Gas Logs Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including Carbon Black, which is known to the State of California to cause cancer, and Carbon Monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — WRT6050\u003c\/h3\u003e\u003ch4\u003eWhat size framing does the WRT6050 need?\u003c\/h4\u003e\u003cp\u003eFrame an opening 59-3\/4 in. wide x 67-1\/8 in. high x 30-1\/8 in. deep, keeping 1-1\/2 in. clearance at the back and sides (not needed at the nailing flanges). For a corner, the framing runs 71 in. along each wall and 100 in. across the front. The fireplace itself is 59-1\/4 in. wide, 67 in. high and 28-1\/2 in. deep.\u003c\/p\u003e\u003ch4\u003eWhat chimney does it use, and how tall must it be?\u003c\/h4\u003e\u003cp\u003eThe IHP 12-inch 12DM double-wall chimney in the US, or 12HT stainless in Canada. The system must be at least 16 ft tall (22 ft with two offset sets) and no more than 50 ft, and it must extend at least 3 ft above the roof penetration and 2 ft above any roof surface within 10 ft.\u003c\/p\u003e\u003ch4\u003eWhat hearth extension does it need?\u003c\/h4\u003e\u003cp\u003eA non-combustible hearth extension at least 20 in. in front of the opening and 12 in. beyond each side, 74 x 20 in. for this size, with a k value of 0.84 or less at 1 in. thick. The supplied ember protector seals the joint to the fireplace.\u003c\/p\u003e\u003ch4\u003eCan I burn gas logs in it?\u003c\/h4\u003e\u003cp\u003eYes. It is approved for vented decorative gas logs (ANSI Z21.60\/Z21.84) and vent-free gas log heaters (ANSI Z21.11.2). With vented logs the damper must be removed or locked fully open. Superior offers Granite Ridge, Silverstone Timber, Mossy Oak and Giant Timbers sets for the series.\u003c\/p\u003e\u003ch4\u003eHow high must a mantel be?\u003c\/h4\u003e\u003cp\u003eCombustible trim or a mantel must stay at least 18 in. from the opening, and anything projecting more than 1-1\/2 in. must be at least 21 in. above the top of the opening. Mantel legs may project up to 11-1\/2 in. at 18 in. from the side of the opening, tapering along a 33-degree line toward it, and combustibles must not overlap the metal front face. Non-combustible facing may overlap the face.\u003c\/p\u003e\u003ch4\u003eWhat is the warranty?\u003c\/h4\u003e\u003cp\u003eA 20-year limited warranty on the product body and firebox; 2 years on refractory, side shields and screens; 90 days on optional glass doors and fuel grates. Labor is paid at IHP's rates within each component's period, up to five years, for the original owner.\u003c\/p\u003e","brand":"Superior","offers":[{"title":"Default Title","offer_id":50593238909090,"sku":"WRT6050","price":4139.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/superior-6050-r16-06-main_pad.jpg?v=1795263511"},{"product_id":"superior-48-wood-burning-traditional-fireplace-wrt8048","title":"Superior 48\" Wood-Burning Traditional Fireplace WRT8048","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Superior WRT8048 is the premium traditional wood-burning fireplace in the Superior line from Innovative Hearth Products. It gives the scale and presence of a large site-built masonry fireplace without the weight, cost and construction time of real masonry, and its astounding 48-inch wide, 42-inch tall opening and low-profile, flush-to-hearth design make it a true focal point for great rooms, family rooms and other spaces with the height to show it off.\u003c\/p\u003e\u003cp\u003eThe look is classic masonry: kiln-fired Mosaic Masonry firebrick in a split herringbone pattern, a massive smoke dome with no visible smoke shelf, a heavy-duty grate with forged andirons and mesh fire screens behind a textured powder-coat face. It is an open-hearth, radiant fireplace built for the experience of a real wood fire, with a fully insulated firebox for colder climates.\u003c\/p\u003e\u003cp\u003eIt is sold as the fireplace box, so you choose the firebrick color, the optional glass door and the chimney route to suit your home. It installs in ordinary framing with small clearances and is also approved for listed vented gas logs and vent-free gas log heaters, so it can take gas later if you want the convenience.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTall opening, flush hearth\u003c\/strong\u003e: 48 in. wide x 42 in. tall opening for a large classic masonry fireplace look, with a low-profile hearth; hearth spacer HS48 required for combustible floor installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMassive smoke dome\u003c\/strong\u003e: no visible smoke shelf, for reliable operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully insulated firebox\u003c\/strong\u003e: increased performance in colder climates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMosaic Masonry firebrick\u003c\/strong\u003e: split herringbone pattern in Ivory, Midnight, Slate Grey or Warm Red (one required).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard equipment\u003c\/strong\u003e: heavy-duty steel grate with rugged forged andirons, mesh fire screens, easy-access damper control and a durable textured powder-coat finish.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional glass door\u003c\/strong\u003e: 48 in. masonry bi-fold ceramic glass door BDMO48EA in ebony (black) trim, for improved safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas log ready\u003c\/strong\u003e: approved for vented gas logs (ANSI Z21.60\/Z21.84) and vent-free gas log heaters (ANSI Z21.11.2).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual outside air kits available\u003c\/strong\u003e: left- and right-hand kits for maximum performance (two recommended); AK4F draws air from a vented crawl space, AK4 through a sidewall.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIHP 12DM chimney\u003c\/strong\u003e: or 12HT stainless, required for Canada.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed, 20-year limited warranty\u003c\/strong\u003e: UL 127 and CAN\/ULC-S610 factory-built fireplace (report F09-142); 20 years on the product body and firebox.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eWRT8048 (box only, catalog F4252)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eSuperior WRT8000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eTraditional open-hearth wood-burning fireplace, front view, factory-built (zero clearance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e60-5\/8\" W x 71-1\/2\" H x 30\" D (1540 x 1817 x 762 mm); 76-1\/4\" (1937 mm) high on the HS48 hearth spacer. Front face 65-3\/4\" high; back 42-3\/8\" wide (manual p.4).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003e60-7\/8\" W x 71-1\/2\" H x 31-5\/8\" D (1547 x 1817 x 804 mm); 76-3\/8\" (1940 mm) high with the HS48 hearth spacer (manual Fig. 1, p.5). Corner installation: 78-7\/8\" (2004 mm) along each wall and 107-3\/8\" (2728 mm) across the front (Fig. 2).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003eOpen fireplace opening 48\" W x 42\" H (1220 x 1067 mm); firebox 33-1\/2\" wide at the back and 24\" deep (manual p.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eBack and sides 1-1\/2\" airspace (not required at the nailing flanges); top spacers 0\"; floor 0\" (HS48 hearth spacer on any floor other than a concrete slab); chimney 2\"; front 48\"; perpendicular side wall 18\" from the opening; non-combustible hearth extension at least 20\" in front and 12\" beyond each side of the opening (72 x 20\"); combustible trim or mantel at least 12\" from the opening, and anything projecting more than 1-1\/2\" at least 15\" above the top of the opening; mantel legs and side trim within the safe zone (Fig. 4a): up to 11-3\/4\" (299 mm) projection at 18\" (458 mm) out from the side of the fireplace opening, tapering in a straight line toward the opening, with nothing combustible on the 6\" (153 mm) metal front face (manual pp.4-6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChimney\u003c\/th\u003e\n\u003ctd\u003eIHP 12 in. 12DM double-wall (US); 12HT stainless (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChimney height\u003c\/th\u003e\n\u003ctd\u003e16 ft minimum (22 ft with two offset sets); 50 ft maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLiner\u003c\/th\u003e\n\u003ctd\u003eMosaic Masonry 48 in. split herringbone firebrick panel set, required (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded\u003c\/th\u003e\n\u003ctd\u003eSteel grate with forged andirons, mesh screens, damper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas logs\u003c\/th\u003e\n\u003ctd\u003eVented (ANSI Z21.60\/Z21.84) and vent-free (ANSI Z21.11.2) gas log heaters approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e347 lb (manual p.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListing\u003c\/th\u003e\n\u003ctd\u003eUL 127 \/ CAN\/ULC-S610, report F09-142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e20-year limited (body and firebox)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace: 60-5\/8 in. wide x 71-1\/2 in. high x 30 in. deep (76-1\/4 in. high on the HS48 hearth spacer); opening 48 in. wide x 42 in. high (manual p.4).\u003c\/li\u003e\n\u003cli\u003eFraming: 60-7\/8 in. wide x 31-5\/8 in. deep; framing height 71-1\/2 in., or 76-3\/8 in. when the fireplace sits on the HS48 hearth spacer (manual Fig. 1, p.5). Corner: 78-7\/8 in. along each wall, 107-3\/8 in. across the front (Fig. 2).\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: back and sides 1-1\/2 in. (not required at the nailing flanges); top spacers 0 in.; floor 0 in. (hearth spacer required except on a concrete slab); chimney 2 in.; 48 in. in front of the opening; a perpendicular side wall 18 in. from the opening. Do not pack the air spaces with insulation (p.5).\u003c\/li\u003e\n\u003cli\u003eHearth extension: non-combustible, at least 20 in. in front of the opening and 12 in. beyond each side, with a thermal conductivity (k) of 0.84 BTU-in\/ft2-hr-°F or less per inch of thickness (pp.5-6).\u003c\/li\u003e\n\u003cli\u003eMantels and trim: combustible trim or a mantel must stay at least 12 in. from the opening; combustibles more than 12 in. above that project more than 1-1\/2 in. must stay at least 15 in. from the top of the opening; mantel legs and side trim may project up to 11-3\/4 in. at 18 in. out from the side of the opening, tapering in a straight line toward the opening, and may come up to but not onto the 6 in. metal front face (Fig. 4a); mantel legs at least 18 in. from a perpendicular side wall (p.6).\u003c\/li\u003e\n\u003cli\u003eCombustible wallboard may touch the sides and top but may not overlap the face; non-combustible facing may overlap the face if it blocks no openings (pp.6, 13).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWRT8048 fireplace (box) with fully insulated firebox and damper with easy-access control\u003c\/li\u003e\n\u003cli\u003eHeavy-duty steel grate with forged andirons\u003c\/li\u003e\n\u003cli\u003eMesh fire screens\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired (sold separately)\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMosaic Masonry 48 in. split herringbone firebrick panel set (choose one): Ivory MOSAIC48IVSH (F4254), Midnight MOSAIC48MISH (F4546), Slate Grey MOSAIC48SGSH (F4545) or Warm Red MOSAIC48WRSH (F4253)\u003c\/li\u003e\n\u003cli\u003eHearth spacer HS48 (F0971) for every installation except directly on a concrete slab\u003c\/li\u003e\n\u003cli\u003eChimney: IHP 12DM in the US (12HT stainless in Canada) - pipe sections for at least 16 ft, a termination (round top RLT-12D or square chase top STL-12D; Canada RLT-12HT), firestop spacers FS-10 at each floor or ceiling (FST10 thimble into an attic), and roof flashing V6F-10DM or V12F-10DM with storm collar SC2-1 when the chimney passes through a roof\u003c\/li\u003e\n\u003cli\u003eCanada: cold air collar kit CAK-12 (also recommended in cold US regions)\u003c\/li\u003e\n\u003cli\u003eNon-combustible hearth extension material (by the installer)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e48 in. masonry bi-fold ceramic glass door, ebony BDMO48EA (F1017)\u003c\/li\u003e\n\u003cli\u003eOutside combustion air kits AK4 (F1091) and AK4F (F1093); AK4X collar and hood only - two kits recommended\u003c\/li\u003e\n\u003cli\u003e30-degree offset and return 30E-12DM (store 30E-12DM-B; Canada 30E-12HT) and chimney supports 12S-12DM \/ 12S-12HT\u003c\/li\u003e\n\u003cli\u003eVented gas log set listed to ANSI Z21.60 or Z21.84, or vent-free gas log heater listed to ANSI Z21.11.2\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eNo official Superior video is published for the WRT8000; we will add one if Superior releases it.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e A wood fireplace that is installed, operated or maintained incorrectly can cause a house fire or carbon-monoxide exposure. This fireplace must be installed by a qualified professional following the Superior WRT8048 installation manual (P\/N 901014-00 Rev. G), with only the listed IHP chimney components, and inspected by your local building official where required.\u003c\/p\u003e\u003ch4\u003eSafety\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eListed to UL 127 and CAN\/ULC-S610 (report F09-142) as a factory-built fireplace for wood, vented gas logs and vent-free gas log heaters (cover, p.2).\u003c\/li\u003e\n\u003cli\u003eNever alter the fireplace or use parts that are not listed for it; keep children and pets away from the hot opening and screen (p.2).\u003c\/li\u003e\n\u003cli\u003eNever install it in a sleeping room of a mobile home; in a manufactured home keep the floor, wall and roof structure intact (pp.9, 24).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eShipping weight 347 lb; opening 48 in. wide; framing 60-7\/8 x 71-1\/2 (76-3\/8 with spacer) x 31-5\/8 in. (pp.4-5).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eInstallation: location, framing and clearances\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eClearances: back and sides 1-1\/2 in., top spacers and floor 0 in., chimney 2 in., 48 in. in front, 18 in. to a perpendicular side wall (p.5).\u003c\/li\u003e\n\u003cli\u003eInstall the HS48 hearth spacer on any floor other than a concrete slab (pp.2, 5).\u003c\/li\u003e\n\u003cli\u003eNon-combustible hearth extension at least 20 in. deep and 12 in. past each side of the opening, with gaps sealed by non-combustible material (pp.5-6).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation: outside air\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eTwo outside air kits are highly recommended. Never terminate the air intake in an attic; keep the air vent no more than 3 ft below the flue outlet; use a vent hood for wall installs (p.6). AK4F draws combustion air from a vented crawl space and AK4 through a sidewall (p.6).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eInstallation: chimney\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUse only IHP 12DM (US) or 12HT stainless (Canada) 12-inch double-wall chimney components (pp.5, 22-24).\u003c\/li\u003e\n\u003cli\u003eMinimum chimney height 16 ft straight or with one offset set, 22 ft with two; 50 ft maximum; no more than 6 ft between elbows; up to two offsets (pp.5, 7).\u003c\/li\u003e\n\u003cli\u003eA chimney supported only by the fireplace may not exceed 20 ft; use the 12S-12DM support above that (p.8).\u003c\/li\u003e\n\u003cli\u003eFirestop spacer FS-10 at each floor\/ceiling penetration with 2 in. clearance; FST10 firestop thimble where the chimney enters an attic (p.8).\u003c\/li\u003e\n\u003cli\u003eAt the roof: pipe at least 30 in. above the highest point of the roof cutout; flashing V6F-10DM (0-6\/12) or V12F-10DM (6\/12-12\/12) with storm collar SC2-1 (p.9).\u003c\/li\u003e\n\u003cli\u003eTermination: at least 3 ft above the roof penetration and 2 ft above any roof within 10 ft; round top RLT-12D or chase top STL-12D; chases at least 30 in. on the shortest side and 19 in. inside; multiple terminations 24 in. apart and 18 in. offset vertically (pp.10-13).\u003c\/li\u003e\n\u003cli\u003eLabel visible chimney sections with label 900599-01 (p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation: firebrick, facing and finishing\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall the complete Mosaic 48 in. split herringbone panel set; allow 72 hours after grouting before the first fire (p.14).\u003c\/li\u003e\n\u003cli\u003eCombustible trim and mantels: at least 12 in. from the opening, at least 15 in. above it if projecting more than 1-1\/2 in., and mantel legs no more than 11-3\/4 in. deep at 18 in. from the side of the opening (Figs. 4\/4a); non-combustible facing may overlap the face if it blocks no openings (pp.6, 13).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas logs and gas line\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVented gas logs must be listed to ANSI Z21.60 or Z21.84 and installed per NFPA 54; vent-free gas log heaters must be listed to ANSI Z21.11.2 (pp.16-17).\u003c\/li\u003e\n\u003cli\u003eRun a 1\/2 in. black iron gas line, installed and leak-tested by a qualified person (p.16).\u003c\/li\u003e\n\u003cli\u003eWith vented gas logs the damper must be removed or locked fully open and the doors fully open; never run an unvented gas log with the chimney removed (pp.17-19).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGlass doors\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eOperate the optional BDMO48EA bi-fold door only fully open or fully closed (pp.17-19).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eOperation and maintenance\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOpen the damper fully and lock it in place before lighting a fire (p.19).\u003c\/li\u003e\n\u003cli\u003eBurn only dry, seasoned solid wood (under 20% moisture; softwood 6-18 months, hardwood 12-24 months); never treated wood, charcoal, coal, trash, driftwood or plywood (pp.2-3, 25-26).\u003c\/li\u003e\n\u003cli\u003eHave the fireplace and chimney inspected and cleaned regularly; use only the IHP replacement grate J4345 (p.20).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eImportant notices for Canada\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eUse the stainless 12HT chimney and the CAK-12 cold air collar kit; follow the Canadian notices (p.24).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local building codes and the authority having jurisdiction.\u003c\/li\u003e\n\u003cli\u003eChimneys, fireplaces and venting: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-211-standard-development\/211\"\u003eNFPA 211 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances\u003c\/a\u003e (clearances and draft, cited in the manual).\u003c\/li\u003e\n\u003cli\u003eGas logs: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e (pp.16-17).\u003c\/li\u003e\n\u003cli\u003eFireplace listing: \u003ca href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL127\"\u003eUL 127 Factory-Built Fireplaces\u003c\/a\u003e and CAN\/ULC-S610 (Canada).\u003c\/li\u003e\n\u003cli\u003eGas log listings: ANSI Z21.60 \/ Z21.84 (vented) and ANSI Z21.11.2 (vent-free gas log heaters).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage: Superior wood-burning fireplace 20 Year Limited Warranty (P\/N 900224-00 Rev. B), printed in the installation manual (p.27).\u003c\/li\u003e\n\u003cli\u003eProduct body and firebox: 20 years from installation. Ceramic glass: thermal breakage only.\u003c\/li\u003e\n\u003cli\u003eRemovable air tubes: 7 years (IHP labor rates in years 1-5). Refractory, side shields and screens: 2 years (hairline cracks excluded). Gold and nickel plating: 2 years (tarnishing excluded).\u003c\/li\u003e\n\u003cli\u003eAir tubes, baffles, brick retainers, cast-iron parts, gaskets and electrical components: 1 year. Optional glass doors: 90 days. Fuel grates: 90 days. Parts not listed: 90 days.\u003c\/li\u003e\n\u003cli\u003eVent components, trim and paint are not covered by the 20-year term.\u003c\/li\u003e\n\u003cli\u003eLabor: paid at IHP's prevailing rates during each component's warranty period.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner only (not transferable), bought from a listed IHP supplier with proof of purchase, installed in the US or Canada.\u003c\/li\u003e\n\u003cli\u003eConditions: installed and repaired by a licensed, IHP-approved contractor to codes, using only the chimney components specified in the manual, and operated and maintained per the instructions.\u003c\/li\u003e\n\u003cli\u003eExclusions: normal wear; accident, fire or flood; abuse, negligence or alteration; unapproved fuels; lack of maintenance; faulty installation; draft or smoking problems from HVAC, chimney height, trees, buildings or wind; utility costs; incidental damages.\u003c\/li\u003e\n\u003cli\u003eClaims: contact the selling dealer; if that is not possible, notify IHP in writing within 90 days of the failure. Replacement parts are generally available for 10 years after the last manufacture date.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/901014-00_G_SUP_WRT8048_WB_Masonry_Box_FP_IICO.pdf\"\u003eInstallation and Operation Manual (WRT8048, P\/N 901014-00)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/901014-01_B_SUP_WRT8048_WB_Masonry_Box-FP_SPEC.pdf\"\u003eSpecification Sheet (WRT8048, P\/N 901014-01)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/785730M_WRT8000_0326-WEB.pdf\"\u003eWRT8000 Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2022\/05\/785852M-WRT8000-Smart-Sheet-0326-WEB.pdf\"\u003eWRT8000 Smart Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2022\/11\/901234-00_A_IHP_CITADEL48_WRT8048_Refractory_Kit_INSTR.pdf\"\u003eRefractory Kit Instructions (Citadel 48 \/ WRT8048)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/127003-01_C_SUP_Wood_Homeowners_Guide_CO.pdf\"\u003eWood Fireplace Homeowner's Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/785692M_Superior-GasLogs-0926-WEB.pdf\"\u003eSuperior Gas Logs Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon black, which is known to the State of California to cause cancer, and carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — WRT8048\u003c\/h3\u003e\u003ch4\u003eWhat size framing does the WRT8048 need?\u003c\/h4\u003e\u003cp\u003eA framed opening 60-7\/8 in. wide x 71-1\/2 in. high x 31-5\/8 in. deep, or 76-3\/8 in. high when the fireplace sits on the HS48 hearth spacer. A corner installation needs 78-7\/8 in. along each wall and 107-3\/8 in. across the front. The fireplace itself is 60-5\/8 in. wide, 71-1\/2 in. high and 30 in. deep.\u003c\/p\u003e\u003ch4\u003eWhat chimney does it use?\u003c\/h4\u003e\u003cp\u003eThe IHP 12-inch double-wall 12DM chimney in the US, or 12HT stainless in Canada. The system must be at least 16 ft tall with a straight flue or one offset set, 22 ft with two offset sets, and no more than 50 ft.\u003c\/p\u003e\u003ch4\u003eWhat else do I need to buy?\u003c\/h4\u003e\u003cp\u003eOne Mosaic Masonry 48 in. split herringbone firebrick set (Ivory, Midnight, Slate Grey or Warm Red), the HS48 hearth spacer for any floor other than a concrete slab, the IHP chimney components, and a non-combustible hearth extension at least 20 in. deep and 12 in. past each side of the opening.\u003c\/p\u003e\u003ch4\u003eCan I burn gas logs in it?\u003c\/h4\u003e\u003cp\u003eYes. It is approved for vented gas logs listed to ANSI Z21.60 or Z21.84 and vent-free gas log heaters listed to ANSI Z21.11.2, fed by a 1\/2 in. black iron gas line. With vented gas logs the damper must be removed or locked fully open.\u003c\/p\u003e\u003ch4\u003eHow close can a mantel be?\u003c\/h4\u003e\u003cp\u003eCombustible trim or a mantel must be at least 12 in. from the opening, and anything projecting more than 1-1\/2 in. must be at least 15 in. above the top of the opening. Mantel legs may project up to 11-3\/4 in. at 18 in. from the side of the opening, tapering toward the opening, but nothing combustible may go on the 6 in. metal front face.\u003c\/p\u003e\u003ch4\u003eWhat is the warranty?\u003c\/h4\u003e\u003cp\u003eA 20-year limited warranty on the product body and firebox for the original owner, with shorter terms on parts such as refractory and screens (2 years) and optional glass doors (90 days).\u003c\/p\u003e","brand":"Superior","offers":[{"title":"Default Title","offer_id":50593238941858,"sku":"WRT8048","price":4849.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/superior-8048-r16-11-main_new.jpg?v=1795263512"},{"product_id":"superior-wood-burning-high-efficiency-fireplace-wct6940ws","title":"Superior Catalytic EPA Wood-Burning Fireplace WCT6940WS","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Superior WCT6940 is a large, high-efficiency wood-burning fireplace from Innovative Hearth Products for homeowners who want a real wood fire that also heats the house. It pairs the look of a traditional masonry fireplace, with an arched steel facade, arched double doors and white stacked refractory panels, with the clean, controllable burn of an EPA-certified catalytic wood heater. It suits a main living space, great room or open-plan home where the fireplace is the centerpiece and a serious heat source at the same time.\u003c\/p\u003e\u003cp\u003eThe design is classic and handsome. A black smooth-steel facade and black arched steel double doors (both required, sold separately) frame two large ceramic glass panels, and the door handles stay cool to the touch. Inside, white textured stacked refractory panels with an integrated ash lip and a decorative cast-iron log retainer give the firebox a brick-lined look. An air-wash system sweeps the glass so the fire stays in view.\u003c\/p\u003e\u003cp\u003eThe spacious 4.0 cubic foot insulated firebox takes logs up to 30 inches long. Superior rates the WCT6940 at up to 80,000 BTU and up to 2,500 square feet, depending on the home, climate and wood; its EPA test rating is 11,500 to 40,000 BTU\/hr at 70% efficiency with emissions of just 1.3 grams per hour, certified to the 2020 EPA standard. A catalytic combustor burns off smoke for long, clean burns, and a bypass control opens extra airflow at start-up and reloading for faster ignition and no smoke spillage into the room.\u003c\/p\u003e\u003cp\u003eHeat moves into the room through the circulating design and an included heat-activated, variable-speed blower that switches on as the fireplace warms up. An insulated outside air kit is included and required, and an optional forced-air kit can duct warm air to another room (note that a fireplace fitted with the forced-air kit is no longer EPA certified, per the manual).\u003c\/p\u003e\u003cp\u003eThe WCT6940 installs as a zero-clearance fireplace in standard wood framing (0 in. at the back and sides from the standoffs) and vents through a 7-inch Superior\/IHP Snap-Pak chimney in the US (Security ASHT or S2100, or DuraVent DuraTech Canada, in Canada), with a 12 ft minimum system height. Compared with the smaller WCT4920 and WCT6920 in the same family, it has the largest firebox and the highest heat output, and it is the model to choose when the fireplace must heat a large space on its own.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCirculating design\u003c\/strong\u003e: facade, arched doors and ceramic glass for optimum heat transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEPA certified\u003c\/strong\u003e: variable-rate certified high-efficiency wood heater, 1.3 g\/hr to the 2020 EPA standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpacious 4.0 cu ft insulated firebox\u003c\/strong\u003e: accepts logs up to 30 in. long.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteel double doors\u003c\/strong\u003e: with heat-resistant handles that stay cool to the touch (doors required, sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStacked textured refractory panels\u003c\/strong\u003e: white, with an integrated ash lip and a decorative cast-iron log retainer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalytic combustor\u003c\/strong\u003e: for maximum performance and long, clean burns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBypass control\u003c\/strong\u003e: greater airflow at start-up for faster ignition and no smoke spillage when reloading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulated outside air kit included\u003c\/strong\u003e: required for use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh heat output\u003c\/strong\u003e: up to 80,000 BTU and up to 2,500 sq ft per Superior (approximate; depends on home design, insulation, climate and wood).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir-wash system\u003c\/strong\u003e: keeps the glass clean.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-activated variable-speed blower included\u003c\/strong\u003e: time-delayed heat distribution, with speed control.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDurable high-temperature paint finish.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional forced-air kit\u003c\/strong\u003e: ducts heated air to another space (BISFWK-1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed\u003c\/strong\u003e: UL 127 and ULC-S610 factory-built fireplace (report 16-150).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20-year limited warranty\u003c\/strong\u003e: on the product body and firebox.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eWCT6940WS (catalog F2846)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eEPA-certified catalytic wood-burning fireplace, front view, zero clearance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e46-1\/4 in. W x 49-3\/8 in. H x 27 in. D; 28-1\/4 in. total depth including the back standoff (manual pp.15, 36); 520 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003e47 in. W x 50 in. H x 28-1\/4 in. D (frame the 46-1\/4 in. front width to 47 in. before pushing the fireplace in); chimney centerline height 66-3\/8 in.; non-combustible base at least 1\/2 in. thick under the fireplace (manual pp.14-15; spec sheet 901005-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003eFirebox front opening 31 in. W x 14-1\/2 in. H (firebox 14 in. deep), behind arched double doors with two ceramic glass panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eBack and sides 0 in. from the standoffs; bottom 0 in. to a non-combustible floor; chimney 2 in. (50 mm); side wall 24 in. (457 mm); mantel 56 in. (1422 mm) above the fireplace base; ceiling 6 ft 8 in. (2032 mm) above the base; non-combustible hearth extension 1 in. thick, 24 in. in front and 6 in. beyond each side of the door opening (manual pp.14, 30; spec sheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat output\u003c\/th\u003e\n\u003ctd\u003eEPA test 11,500-40,000 BTU\/hr; up to 80,000 BTU peak per Superior\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e70% (manual p.27)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEmissions\u003c\/th\u003e\n\u003ctd\u003e1.3 g\/hr, EPA 2020 standard (40 CFR Part 60)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating area\u003c\/th\u003e\n\u003ctd\u003eUp to 2,500 sq ft (approximate, per Superior)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox volume\u003c\/th\u003e\n\u003ctd\u003e4.0 cu ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e31 x 14-1\/2 x 14 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum log length\u003c\/th\u003e\n\u003ctd\u003e30 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue\u003c\/th\u003e\n\u003ctd\u003e7 in. diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChimney\u003c\/th\u003e\n\u003ctd\u003eUS: Superior\/IHP 7 in. Snap-Pak; Canada: Security ASHT or S2100, or DuraVent DuraTech Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBlower\u003c\/th\u003e\n\u003ctd\u003eHeat-activated UZY5 variable-speed blower with VRUW speed control, included; 120 V, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit weight\u003c\/th\u003e\n\u003ctd\u003e520 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListing\u003c\/th\u003e\n\u003ctd\u003eUL 127 \/ ULC-S610, report 16-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e20-year limited (body and firebox)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUnit size, framing, viewing area and clearances are listed together in the Specifications table above (manual pp.14-15, 30, 36).\u003c\/li\u003e\n\u003cli\u003eThe spec sheet gives total depth as 27-1\/2 in. including the back spacer, less 1\/2 in. for drywall to sit flush with the facing.\u003c\/li\u003e\n\u003cli\u003eHearth extension: non-combustible, 1 in. thick, at least 24 in. in front of and 6 in. to each side of the door opening; a 1\/2 in. non-combustible base under the fireplace (manual p.14 and label).\u003c\/li\u003e\n\u003cli\u003eCeiling opening for the chimney: 13-7\/16 x 13-7\/16 in. (Table 3); wall opening 13-7\/16 x 14 in. (Table 4).\u003c\/li\u003e\n\u003cli\u003eOnly non-combustible material may project over the fireplace front; combustible facing must sit flush (manual p.14).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWCT6940WS fireplace with catalytic combustor and bypass control\u003c\/li\u003e\n\u003cli\u003eWhite textured stacked refractory panels with ash lip and cast-iron log retainer\u003c\/li\u003e\n\u003cli\u003eHeat-activated UZY5 blower with VRUW variable-speed control\u003c\/li\u003e\n\u003cli\u003eInsulated outside air kit (4 in. insulated flex, up to 10 ft, and fireplace adaptor)\u003c\/li\u003e\n\u003cli\u003eInstallation and operation manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired (sold separately)\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFacade: black smooth steel WCT6940-FAC-BLK\u003c\/li\u003e\n\u003cli\u003eDoors: black arched steel double doors WCT6940-DOOR-BLK\u003c\/li\u003e\n\u003cli\u003e7 in. Superior\/IHP Snap-Pak chimney, 12 ft minimum (15 ft with offsets): pipe lengths 7SPS24, 7SPS36, 7SPS48; ceiling firestop 7SPFS; roof flashing by pitch (7SPFF flat, 7SPF5 2\/12-5\/12, 7SPF10 6\/12-10\/12); storm collar 7SPSC; cap 7SPC (a rain cap is required)\u003c\/li\u003e\n\u003cli\u003eAttic insulation shield 7SPIS where the chimney passes through an insulated attic\u003c\/li\u003e\n\u003cli\u003eNon-combustible hearth extension material (by the installer)\u003c\/li\u003e\n\u003cli\u003e120 V electrical supply for the blower (by a qualified electrician)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eForced-air starter kit BISFWK-1 (5 in. duct, installed on the side of the fireplace) with 5 in. flex 5FLEX15 or 5FLEX25; not EPA certified when installed\u003c\/li\u003e\n\u003cli\u003eSnap-Pak supports and bands: adjustable support 7SPAS, support band 7SPSB (required at the upper elbow of each offset), wall band 7SPWB, roof brace 7SPRB, wall firestop 7SPWF\u003c\/li\u003e\n\u003cli\u003eExtra outside air duct UZI and adaptor UZIAD\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eNo official Superior video is published for the WCT6940; we will add one if Superior releases it.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e A wood fireplace that is installed, operated or maintained incorrectly can cause a house fire or carbon-monoxide exposure. This fireplace must be installed by a qualified professional following the Superior installation manual (WCT6940WS, P\/N 901005-00 Rev. A), with only the listed chimney components, and inspected by your local building official where required.\u003c\/p\u003e\u003ch4\u003eProduct and safety information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eListed to UL 127 and ULC-S610 (report 16-150) as a factory-built fireplace; EPA-certified to 40 CFR Part 60, 1.3 g\/hr (manual pp.2, 27).\u003c\/li\u003e\n\u003cli\u003eChimney: only the IHP 7 in. Snap-Pak chimney in the United States, or Security ASHT or S2100 or DuraVent DuraTech Canada (DTC) in Canada, where the Security ASHT adaptor 7IHP2 is required. Other chimney components, or any modification of the system, void the warranty, listings and approvals (pp.3, 32).\u003c\/li\u003e\n\u003cli\u003eInstall smoke detectors and a carbon-monoxide monitor in the home (p.8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFuel and operation\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBurn only dry, seasoned natural wood (ideally 15-20% moisture; hardwoods seasoned 12-24 months). Never burn trash, treated or painted wood, plywood, coal, charcoal, cardboard, salt-water driftwood or any flammable liquid (pp.4, 9).\u003c\/li\u003e\n\u003cli\u003eOpen the bypass to light and reload; close it once the catalytic combustor gauge reaches the active range (pp.4-6).\u003c\/li\u003e\n\u003cli\u003eBreak-in: make the first five or six fires small (30-60 minutes) to cure the refractory, and ventilate the room for the paint odor (p.6).\u003c\/li\u003e\n\u003cli\u003eKeep the doors closed while burning, except when lighting and reloading. Glass and surfaces get very hot: supervise children and pets.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCheck the catalytic combustor at least three times a season and clean it about once a year; it is designed for at least 10,000 hours (pp.8-10).\u003c\/li\u003e\n\u003cli\u003eHave the chimney inspected and cleaned regularly to prevent creosote build-up; know how to respond to a chimney fire (p.8).\u003c\/li\u003e\n\u003cli\u003eDispose of ashes in a metal container with a tight lid, away from combustibles (p.11).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFireplace installation and framing\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFrame the opening 47 in. wide, 50 in. high and 28-1\/4 in. deep; the fireplace sits on a non-combustible base at least 1\/2 in. thick (pp.14-15).\u003c\/li\u003e\n\u003cli\u003eKeep 80 in. clear above the fireplace base to the ceiling and keep only wood framing above the top (p.13).\u003c\/li\u003e\n\u003cli\u003eInstall the facade before finishing; it must stay removable (p.14).\u003c\/li\u003e\n\u003cli\u003eCold climates: chases on outside walls have their own cold-climate installation requirements (p.14).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHearth extension\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eNon-combustible hearth extension 1 in. thick, extending 24 in. in front and 6 in. beyond each side of the door opening (p.14 and label).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eBlower and electrical\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eThe UZY5 blower and VRUW speed control are wired to 120 V, 60 Hz through the supplied electrical box at the lower right, by a qualified electrician to local code (p.18).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eOutside air kit\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eThe outside air kit is mandatory. Use up to 20 ft of 4 in. insulated flex (up to 40 ft with 6 in. flex); the inlet must draw from outdoors, never from an attic, basement or garage, and sit no more than 10 ft above the fireplace base (p.18).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eChimney system\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUse only 7 in. Superior\/IHP Snap-Pak components in the US, or Security ASHT\/S2100 or DuraVent DuraTech Canada with adaptor 7IHP2 in Canada (pp.22, 28).\u003c\/li\u003e\n\u003cli\u003eMinimum chimney height 12 ft above the fireplace (15 ft with offsets); add 18 in. for every 2,000 ft of elevation (p.5).\u003c\/li\u003e\n\u003cli\u003eTermination: at least 3 ft above the roof penetration and 2 ft above any roof, wall or building within 10 ft; a rain cap is required (p.24).\u003c\/li\u003e\n\u003cli\u003eOffsets: no more than two, each up to 30 degrees (SPSE15\/SPSE30 elbows), with a support band at the upper elbow; offsets may not pass through a floor or ceiling (pp.19, 22).\u003c\/li\u003e\n\u003cli\u003eThe fireplace supports up to 9 ft of chimney; use supports above that, and brace the chimney above the roof when it extends more than 4 ft (pp.19, 25).\u003c\/li\u003e\n\u003cli\u003eKeep 2 in. clearance from the chimney to combustibles; use the ceiling firestop at every floor\/ceiling and the attic insulation shield in attics (pp.20-23).\u003c\/li\u003e\n\u003cli\u003eMasonry chimneys need a liner listed to UL 1777 (US) or ULC-S635\/S640 (Canada), rated 2100°F (p.25).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation accessories\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eForced-air kit BISFWK-1 with 5 in. flex; thermostat HCTW; outside air parts UZI and UZIAD (pp.26, 29).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to all local building codes (manual p.13).\u003c\/li\u003e\n\u003cli\u003eFireplace listing: \u003ca href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL127\"\u003eUL 127 Factory-Built Fireplaces\u003c\/a\u003e and ULC-S610 (Canada).\u003c\/li\u003e\n\u003cli\u003eEmissions: certified to \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-40\/chapter-I\/subchapter-C\/part-60\/subpart-AAA\"\u003eEPA 40 CFR Part 60, Subpart AAA (residential wood heaters)\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eMasonry chimney liners: \u003ca href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL1777\"\u003eUL 1777 Chimney Liners\u003c\/a\u003e (US) or ULC-S635\/S640 (Canada).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage: Superior Wood-Burning Fireplace 20 Year Limited Warranty (P\/N 901005-00 Rev. A, manual p.32); catalytic combustor under the separate IHP Limited Three Year Warranty (P\/N 900224-00 Rev. B, manual p.31).\u003c\/li\u003e\n\u003cli\u003eProduct body and firebox: 20 years. Ceramic glass: 20 years, thermal breakage only.\u003c\/li\u003e\n\u003cli\u003eRemovable air tubes: 7 years (IHP labor rates in years 1-5). Refractory, side shields and screens: 2 years (hairline cracks excluded). Gold and nickel plating: 2 years.\u003c\/li\u003e\n\u003cli\u003eAir tubes, baffles, brick retainers, cast-iron parts, gaskets and electrical components: 1 year. Optional glass doors: 90 days. Fuel grates: 90 days. Parts not listed: 90 days.\u003c\/li\u003e\n\u003cli\u003eCatalytic combustor: 3-year limited warranty from purchase.\u003c\/li\u003e\n\u003cli\u003eVent components, trim, paint and stains are not covered by the 20-year term.\u003c\/li\u003e\n\u003cli\u003eLabor: paid at IHP's prevailing rates during each component's warranty period, up to five years.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner only (not transferable), bought from a listed IHP supplier with proof of purchase, installed in the US or Canada and kept at the original site.\u003c\/li\u003e\n\u003cli\u003eConditions: installed by a licensed, IHP-approved contractor to codes, using only the specified chimney components, burning approved fuel, and maintained per the instructions.\u003c\/li\u003e\n\u003cli\u003eExclusions: normal wear; accident, fire or flood; abuse or alteration; abnormal fuels (driftwood, coal, plywood, binder-based products); lack of maintenance; faulty installation; draft or smoking problems from the building, HVAC, chimney height, trees or wind.\u003c\/li\u003e\n\u003cli\u003eClaims: contact the selling dealer; if that is not possible, notify IHP in writing within 90 days of the failure. Replacement parts are generally available for 10 years after the last manufacture date.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/901005-00_A_SUP_WCT6940WS_CAT_EPA_Wood_FPs_EN_IICO.pdf\"\u003eInstallation and Operation Manual (WCT6940WS, P\/N 901005-00)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/901005-01_NC_SUP_WCT6940WS_CAT_Trad_EPA_FPs_EN_SPEC.pdf\"\u003eSpecification Sheet (WCT6940WS, P\/N 901005-01)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/785680M_WCT6940Series_0923-WEB.pdf\"\u003eWCT6940 Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2022\/05\/785856M-WCT6940-Smart-Sheet-0923-WEB.pdf\"\u003eWCT6940 Smart Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/Snap-Pak_Smart_Sheet_0719.pdf\"\u003eSnap-Pak Chimney Smart Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/506019-77_F_IHP_Forced_Air_Heating_EN_INSTR.pdf\"\u003eForced Air Duct Instructions (EPA fireplaces)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon black and carbon monoxide, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — WCT6940WS\u003c\/h3\u003e\u003ch4\u003eWhat size framing does the WCT6940WS need?\u003c\/h4\u003e\u003cp\u003eA framed opening 47\" wide, 50\" high and 28-1\/4\" deep, with the fireplace on a non-combustible base at least 1\/2\" thick. Clearance is 0\" at the back and sides from the standoffs, so it frames into standard wood framing.\u003c\/p\u003e\u003ch4\u003eWhat chimney does it use?\u003c\/h4\u003e\u003cp\u003eA 7\" Superior\/IHP Snap-Pak chimney in the US, or Security ASHT\/S2100 or DuraVent DuraTech Canada with adaptor 7IHP2 in Canada. The chimney must be at least 12 ft tall (15 ft with offsets), end at least 3 ft above the roof penetration and 2 ft above anything within 10 ft, and have a rain cap.\u003c\/p\u003e\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. The wood fire needs no electricity. The included UZY5 blower runs on 120 V, so it stops until power returns.\u003c\/p\u003e\u003ch4\u003eHow high must the mantel be?\u003c\/h4\u003e\u003cp\u003eA combustible mantel must be at least 56\" above the base of the fireplace, and the ceiling at least 6 ft 8 in above the base.\u003c\/p\u003e\u003ch4\u003eHow much area does it heat?\u003c\/h4\u003e\u003cp\u003eSuperior rates it at up to 2,500 sq ft and up to 80,000 BTU, depending on the home's design, insulation, climate and wood. Its EPA test rating is 11,500 to 40,000 BTU\/hr at 70% efficiency.\u003c\/p\u003e\u003ch4\u003eWhat's the warranty?\u003c\/h4\u003e\u003cp\u003e20 years on the product body and firebox, and on the ceramic glass for thermal breakage. The catalytic combustor has its own 3-year limited warranty. Shorter terms apply to air tubes (7 years), refractory (2 years), and electrical and cast-iron parts (1 year).\u003c\/p\u003e","brand":"Superior","offers":[{"title":"Default Title","offer_id":50593239072930,"sku":"WCT6940WS","price":7469.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Superior-Wood-Burning-High-Efficiency-Fireplace-WCT6940WS_3246__62727.1785139205.1280.1280.jpg?v=1793378844"},{"product_id":"superior-wood-burning-1-6-cu-ft-freestanding-stove-wxs2016ws","title":"Superior 1.6 cu. ft. Freestanding Wood Stove WXS2016WS","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Superior WXS2016WS is the compact model of the WXS2000 Series freestanding wood stoves from Innovative Hearth Products. It is an EPA 2020 certified stove built from precision-cut heavy-gauge steel, sized for a single room, a cabin or a smaller home, and it is approved for manufactured (mobile) homes in the US.\u003c\/p\u003e\u003cp\u003eA large rectangular steel door with ceramic glass gives a wide view of the fire, and an integral air wash system keeps the glass clear. High-density firebrick and a baffle hold heat and burn the wood cleanly, and a single one-touch air control sets the burn. The black painted body sits on the included black pedestal base.\u003c\/p\u003e\u003cp\u003eSuperior rates it at up to 55,600 BTU\/hr with cord wood in its manual, for roughly 700 to 1,400 sq. ft. An optional 150 CFM blower with Dial-A-Temp speed control spreads the heat further. It vents through a 6 in. flue collar into a listed chimney.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEPA 2020 certified\u003c\/strong\u003e: 1.7 g\/hr particulate in the manual (smart sheet: 2.1 g\/hr).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 55,600 BTU\/hr\u003c\/strong\u003e: EPA test range 12,800 to 39,400 BTU\/hr; efficiency 72% HHV \/ 78% LHV (CSA B415.1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeats 700 to 1,400 sq. ft.\u003c\/strong\u003e: a compact stove for a room, cabin or small home.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge rectangular door\u003c\/strong\u003e: steel door with ceramic glass for strength and heat transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir wash system\u003c\/strong\u003e: keeps the glass clean for a clear view of the fire.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-gauge steel and firebrick\u003c\/strong\u003e: precision-cut steel body and high-density firebrick that retains heat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne-touch control\u003c\/strong\u003e: a single air control for easy operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlack pedestal base included\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional blower\u003c\/strong\u003e: 150 CFM blower with Dial-A-Temp speed control (H8873, BLWR-ES-S-150, 120 V, 1 A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMobile home approved, 20-year limited warranty\u003c\/strong\u003e: US manufactured-home installation with the outside air kit; 20-year limited coverage on the body, firebox and ceramic glass.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eWXS2016WS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eFreestanding EPA-certified wood-burning stove on a pedestal base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e24-3\/8\" W x 30-1\/4\" H x 19-3\/8\" D (WXS2000 smart sheet 785871M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eNone required (freestanding)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eAlcove: minimum width between combustibles 44\" with double-wall pipe and 48\" for all other installations (manual p.26). Non-combustible floor protector at least 3\/8\" thick (p.26): USA, at least 16\" in front of the door opening and 8\" to each side of the door opening; Canada, 450 mm (17-3\/4\") in front of the door opening, 200 mm (8\") to each side of the stove body and 200 mm to the rear or to the wall, whichever is smaller; it also covers the floor under the connector and at least 2\" to either side (manual p.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat output\u003c\/th\u003e\n\u003ctd\u003eManual p.8: up to 55,600 BTU\/hr with cord wood (EPA test range 12,800-39,400 BTU\/hr, p.4). Smart sheet 785871M: 55,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e72% HHV \/ 78% LHV, low burn rate, CSA B415.1 (manual p.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEmissions\u003c\/th\u003e\n\u003ctd\u003eManual p.4: 1.7 g\/hr particulate, CO 1.8 g\/min average. Smart sheet 785871M: 2.1 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox volume\u003c\/th\u003e\n\u003ctd\u003e1.52 cu. ft. (manual p.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum log length\u003c\/th\u003e\n\u003ctd\u003eManual p.8: 18\" (457 mm) maximum, 16\" (406 mm) recommended. Smart sheet 785871M: 16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurn time\u003c\/th\u003e\n\u003ctd\u003eManual p.8: 6 to 8 hours maximum. Smart sheet 785871M: 7 to 9 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating capacity\u003c\/th\u003e\n\u003ctd\u003e700 to 1,400 sq. ft. (manual p.8; smart sheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue collar\u003c\/th\u003e\n\u003ctd\u003e6\" (single-wall or double-wall connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e280 lb shipping (manual p.8; smart sheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eEPA certified (2020); approved for US manufactured (mobile) homes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e20-year limited (body, firebox, ceramic glass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eStove body with high-density firebrick and baffle\u003c\/li\u003e\n\u003cli\u003eSteel door with ceramic glass\u003c\/li\u003e\n\u003cli\u003eBlack pedestal base\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cspan\u003eDownloads\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli class=\"fusion-li-item product-downloads\"\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003e\u003ca class=\"product-downloads-custom\" style=\"color: #ff0000;\" href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/785728M_WXS2000_0526-WEB.pdf\" target=\"_blank\" rel=\"noopener\" download=\"\"\u003eWXS2000\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"fusion-li-item product-downloads\"\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003e\u003ca class=\"product-downloads-custom\" style=\"color: #ff0000;\" href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2022\/04\/785871M-WXS2000-Smart-Sheet-0526-WEB.pdf\" target=\"_blank\" rel=\"noopener\" download=\"\"\u003eSS, WXS2000\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"fusion-li-item product-downloads\"\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003e\u003ca class=\"product-downloads-custom\" style=\"color: #ff0000;\" href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/900917-00_D_SUP_WXS2016_Woodstove_EN_IICO.pdf\" target=\"_blank\" rel=\"noopener\" download=\"\"\u003eIICO, SUP WXS2016 Wood Stove EN\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"fusion-li-item product-downloads\"\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003e\u003ca class=\"product-downloads-custom\" style=\"color: #ff0000;\" href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2022\/11\/900917-01_D_SUP_-WXS2016_Woodstove_FR_IICO.pdf\" target=\"_blank\" rel=\"noopener\" download=\"\"\u003eIICO, SUP WXS2016 Woodstove FR\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"fusion-li-item product-downloads\"\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003e\u003ca class=\"product-downloads-custom\" style=\"color: #ff0000;\" href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/900180-00_D_SUP_EPA_Certified_List_SPEC.pdf\" target=\"_blank\" rel=\"noopener\" download=\"\"\u003eSPEC, Solid Fuel EPA List\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"fusion-li-item product-downloads\"\u003e\n\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003e\u003ca class=\"product-downloads-custom\" style=\"color: #ff0000;\" href=\"https:\/\/ihp.us.com\/wp-content\/uploads\/2021\/09\/900917-02_A_SUP_WXS2016_Woodstove_SPEC.pdf\" target=\"_blank\" rel=\"noopener\" download=\"\"\u003eSPEC, SUP WXS2016 Wood Stove EN\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eVenting\u003c\/h3\u003e\u003cp\u003eThe WXS2016 has a 6-inch flue collar and vents into a UL 103 HT (2100°F) Class A factory-built chimney, or a code-approved masonry chimney with a flue liner, through a 6-inch single-wall (24-gauge minimum black steel) or double-wall stove connector, all of one brand. The chimney must rise at least 3 ft above the roof penetration and 2 ft higher than any roof surface within 10 ft, and the stove needs about 12 ft of effective draw; each 90° change of direction costs about 5 ft. The connector may not pass through an attic, closet, floor or ceiling; a wall pass-through follows one of the four NFPA 211 systems in the manual (12, 9, 6 or 2 in. clearance). Superior has not tested a horizontal connection (manual pp.4-11).\u003c\/p\u003e\n\u003ch3\u003eRequired components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStove connector: DuraVent DVL 6 in. double-wall black stove pipe, starting with stove adaptor 6DVL-AD (lengths 6DVL-06 to 6DVL-48, adjustable 6DVL-6ADJ \/ 6DVL-12ADJ, elbows 6DVL-E45 \/ 6DVL-E90)\u003c\/li\u003e\n\u003cli\u003eChimney pipe: DuraVent DuraTech 6 in. Class A chimney sections (6DT-06 to 6DT-60CF galvanized, or 6DT-06SS to 6DT-60SSCF stainless)\u003c\/li\u003e\n\u003cli\u003eCeiling support where the chimney starts: 6DT-RCS-2 round or 6DT-FCS-2 flat ceiling support box, or support box 6DT-CS11-2 \/ 6DT-CS24-2 \/ 6DT-CS36-2 (attic-shield versions 6DT-CS24IS-2, 6DT-CS24RIS-2, 6DT-CS36IS-2)\u003c\/li\u003e\n\u003cli\u003eFirestop at each further floor or ceiling: 6DT-FRS firestop radiation shield; 6DT-IS attic insulation shield where the chimney passes an insulated attic\u003c\/li\u003e\n\u003cli\u003eRoof flashing by roof pitch: 6DT-FF flat, 6DT-F6 (0\/12-6\/12), 6DT-F12 (7\/12-12\/12), 6DT-F18 (13\/12-18\/12), 6DT-F24 (19\/12-24\/12); 6DT-CTF for a chase top\u003c\/li\u003e\n\u003cli\u003eStorm collar: 5DT-SC (fits 5 and 6 in. DuraTech)\u003c\/li\u003e\n\u003cli\u003eChimney cap: 6DT-VC; a cap with spark arrestor (add 5DT-SA) is required in a mobile home\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBlower kit H8873 (BLWR-ES-S-150), 150 CFM with Dial-A-Temp speed control, 120 V, 60 Hz, 1 A (manual pp.25-26)\u003c\/li\u003e\n\u003cli\u003eOutside air kit (required in a mobile home): UZIAD outside air coupler kit, UZI outside air ducting kit and F4062 outside air panel and air channel kit (manual pp.12, 25)\u003c\/li\u003e\n\u003cli\u003eTouch-up paint F5035 (TSPK-B), satin black, 12 oz. aerosol\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e A wood stove that is installed, operated or maintained incorrectly can cause a house fire or carbon-monoxide exposure. Install it exactly as the Superior WXS2016 installation manual (P\/N 900917-00 Rev. D) describes, with a listed chimney, and have it inspected by your local building official where required.\u003c\/p\u003e\u003ch4\u003eSafety\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBurn only dry, seasoned wood; keep combustibles away from the hot stove, and keep children and pets away from hot surfaces.\u003c\/li\u003e\n\u003cli\u003eAlcove installations need at least 44 in. between combustibles with double-wall pipe, or 48 in. otherwise (p.26).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFloor protection\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNon-combustible floor protector at least 3\/8 in. thick: USA 16 in. in front of and 8 in. to each side of the door opening; Canada 450 mm in front, 200 mm to each side of the body and 200 mm to the rear or the wall; also under the connector and 2 in. to either side (pp.6, 26).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eManufactured (mobile) homes\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eApproved for US manufactured homes with an outside air kit, the stove secured to the floor and grounded to the chassis, and a spark arrestor at the chimney termination; never in a sleeping room (pp.4, 10, 26).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eChimneys and solid-fuel appliances: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-211-standard-development\/211\"\u003eNFPA 211 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances\u003c\/a\u003e; in Canada, CSA B365.\u003c\/li\u003e\n\u003cli\u003eChimney listing: UL 103HT factory-built chimney.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSuperior 20-year limited warranty (manual p.27): product body, firebox and ceramic glass (thermal breakage only) for 20 years. The same page lists removable air tubes both under the 20-year term and as repair or replacement for five years.\u003c\/li\u003e\n\u003cli\u003eRefractory and screens: 2 years. Cast iron parts, electrical components and gaskets: 1 year. Parts not otherwise listed: 90 days (all from installation).\u003c\/li\u003e\n\u003cli\u003eLabor: IHP pays prevailing rates for each component's warranty period; for the 20-year coverage, labor is paid for up to one year.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including Carbon Black, which is known to the State of California to cause cancer, and Carbon Monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — WXS2016WS\u003c\/h3\u003e\u003ch4\u003eHow much area does the WXS2016WS heat?\u003c\/h4\u003e\u003cp\u003eSuperior rates it at 700 to 1,400 sq. ft., with up to 55,600 BTU\/hr from cord wood in the manual (55,000 BTU\/hr on the smart sheet).\u003c\/p\u003e\u003ch4\u003eHow long can the logs be?\u003c\/h4\u003e\u003cp\u003eThe manual gives 18 in. maximum with 16 in. recommended; the smart sheet lists 16 in.\u003c\/p\u003e\u003ch4\u003eWhat chimney does it need?\u003c\/h4\u003e\u003cp\u003eA 6 in. connector, single-wall 24-gauge black steel or double-wall, to a UL 103HT (2100°F) Class A chimney or a lined masonry chimney. The chimney must rise at least 3 ft above the roof penetration and 2 ft above any roof within 10 ft.\u003c\/p\u003e\u003ch4\u003eWhat floor protection does it need?\u003c\/h4\u003e\u003cp\u003eA non-combustible floor protector at least 3\/8 in. thick, extending 16 in. in front of the door opening and 8 in. to each side of it in the USA, and under the connector with 2 in. to either side.\u003c\/p\u003e\u003ch4\u003eCan it go in a mobile home?\u003c\/h4\u003e\u003cp\u003eYes, in the US, with the outside air kit, the stove secured to the floor and grounded to the chassis, and a spark arrestor on the chimney, but never in a sleeping room.\u003c\/p\u003e\u003ch4\u003eIs a blower available?\u003c\/h4\u003e\u003cp\u003eYes. The optional H8873 (BLWR-ES-S-150) 150 CFM blower with Dial-A-Temp speed control runs on 120 V, 1 A.\u003c\/p\u003e","brand":"Superior","offers":[{"title":"Default Title","offer_id":50593240907938,"sku":"WXS2016WS","price":1949.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Superior-Wood-Burning-16-cuft-Freestanding-Stove-WXS2016WS_11147__47132.1785139950.1280.1280.jpg?v=1792472687"},{"product_id":"majestic-products-42-see-thru-radiant-designer-series-wood-fireplace-dsr42","title":"Majestic Designer 42\" See-Through Wood Fireplace DSR42","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Majestic Designer Series DSR42 is a 42 in. see-through wood-burning fireplace: one real wood fire, open to two rooms. Set into a dividing wall between a living room and a dining room, kitchen or den, it gives both spaces the sight, sound and warmth of a crackling fire.\u003c\/p\u003e\u003cp\u003eThe firebox comes finished with refractory, an integral grate, a firescreen, a flue damper and a smoke shield. DM1242 bi-fold glass doors (black or stainless trim) can be added to close it off when the fire dies down.\u003c\/p\u003e\u003cp\u003eAs a wood fireplace its role is ambiance and radiant warmth close to the fire. An optional outside air kit brings combustion air from outdoors.\u003c\/p\u003e\u003cp\u003eIt is a UL 127 \/ ULC-S610 factory-built fireplace with close clearances (1\/2 in. back and sides, 0 in. top standoffs to header) and an SL11 11 in. chimney that can run from 14 ft up to 90 ft. Finish both faces with any non-combustible material; a combustible mantel can sit 12 in. above the opening.\u003c\/p\u003e\u003cp\u003eGas log sets, gas log lighters and gas inserts can be used if installed to the manual (up to 100,000 BTU\/h, damper locked open). It has been in Majestic's line since 1992, a proven choice for a two-sided wood fire.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSee-through wood fire\u003c\/strong\u003e: Two-sided 42 in. opening (owner's manual service parts: 42 in. see-thru woodburning fireplace); solid wood fuel only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL listed\u003c\/strong\u003e: Tested and listed to UL 127 and ULC-S610 as a factory-built fireplace (manual p.4).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefractory, grate and screen included\u003c\/strong\u003e: Refractory, firescreen, grate, outside-air inlet hood and plate, attic insulation shield and four hearth strips ship with the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterior\u003c\/strong\u003e: Refractory-lined firebox with integral grate, flue damper and smoke shield.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional glass doors\u003c\/strong\u003e: DM1242 (black trim) or DM1242S (stainless trim) bi-fold glass doors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance framing\u003c\/strong\u003e: 1\/2 in. back and sides, 0 in. top standoffs to header.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed chimney system\u003c\/strong\u003e: SL11 11 in. chimney: 14 ft minimum straight (16.5 ft with an offset), 90 ft maximum; listed cap.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutside air\u003c\/strong\u003e: Optional outside air: 4 in. duct up to 20 ft or 6 in. up to 40 ft (UL 181 Class 0\/1, P-trap).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas log provision\u003c\/strong\u003e: Knockouts for 1\/2 in. gas pipe; certified gas logs up to 100,000 BTU\/h with the damper locked open.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSleeping rooms\u003c\/strong\u003e: May be installed in sleeping rooms; not approved for manufactured housing.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eDSR42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eWood-burning factory-built fireplace (see-through)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eSeasoned firewood only (gas log provision up to 100,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOpening\u003c\/th\u003e\n\u003ctd\u003e42 in. see-through opening; fireplace 47 in. wide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRough framing\u003c\/th\u003e\n\u003ctd\u003esee Fig. 3.5 (48 in. high framing; load-bearing header, if needed, at 60 in. above the base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. back and sides, 0 in. top standoffs to header\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChimney\u003c\/th\u003e\n\u003ctd\u003eSL11 11 in. chimney: 14 ft minimum straight (16.5 ft with an offset), 90 ft maximum; listed cap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListing\u003c\/th\u003e\n\u003ctd\u003eUL 127 and ULC-S610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRough framing: see Fig. 3.5 (48 in. high framing; load-bearing header, if needed, at 60 in. above the base).\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 1\/2 in. back and sides, 0 in. top standoffs to header; chimney 2 in. air space at all levels; door opening at least 24 in. from a sidewall; combustible sidewalls 24 in. from the opening.\u003c\/li\u003e\n\u003cli\u003eMantel: combustible mantel up to 12 in. deep at least 12 in. above the opening; combustible trim may project up to 1-1\/2 in. no closer than 6 in. to the top of the decorative front.\u003c\/li\u003e\n\u003cli\u003eHearth extension (required): R-1.03 insulated, non-combustible, 20 in. in front and 12 in. to each side of the opening (HX4 is 66 in. long); see sect. 7 for the finished-hearth height limit.\u003c\/li\u003e\n\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace with refractory, firescreen and grate\u003c\/li\u003e\n\u003cli\u003eOutside-air inlet hood and plate\u003c\/li\u003e\n\u003cli\u003eAttic insulation shield\u003c\/li\u003e\n\u003cli\u003eFour protective metal hearth strips\u003c\/li\u003e\n\u003cli\u003eInstallation and owner's manuals\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUnit is complete — no required options needed.\u003c\/li\u003e\n\u003cli\u003eDesigner 42 requires an SL1100 chimney venting system, not included with purchase.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDM1242 (black trim) or DM1242S (stainless trim) bi-fold glass doors\u003c\/li\u003e\n\u003cli\u003eDecorative shrouds LDS33, LDS46, LDS-BV and LDSCP-M corner post kit\u003c\/li\u003e\n\u003cli\u003eDecorative caps DTO134\/146, DTS134\/146\u003c\/li\u003e\n\u003cli\u003eHX3 \/ HX4 hearth extension panels\u003c\/li\u003e\n\u003cli\u003eCAK5A chimney air kit (required in Canada)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/4012_134.pdf\"\u003eDesigner Series DSR42 install manual 4012-134, Rev J 10\/24\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/4012-135A_DSR42_Owners_Manual_02-20-15.pdf\"\u003eDesigner Series DSR42 owner's manual 4012-135, Rev P 6\/25 with warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a wood-burning fireplace. Improper installation, venting or use can cause a house fire or carbon-monoxide exposure. Majestic requires installation by a qualified installer following the installation manual and local building codes (install manual 4012-134, Rev J 10\/24, p.1), and the chimney should be inspected regularly. Burn only dry, seasoned wood, never use flammable liquids to start or freshen a fire, and keep children and furniture away from hot surfaces.\u003c\/p\u003e\u003ch4\u003eProduct \u0026amp; safety information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eListed to UL 127 and ULC-S610; solid wood fuel only; over-firing voids the warranty (p.4).\u003c\/li\u003e\n\u003cli\u003eUse only Hearth \u0026amp; Home approved parts; modifications void the listing. Installation by a qualified installer (HHT factory-trained or NFI certified recommended).\u003c\/li\u003e\n\u003cli\u003eNot approved for manufactured housing; may be installed in sleeping rooms.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGetting started\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003ePlan location, chase and chimney route; avoid basements (pp.5-8).\u003c\/li\u003e\n\u003cli\u003eOutside-air kits and some components must be installed with the fireplace.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFraming \u0026amp; clearances\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eRough framing see Fig. 3.5 (48 in. high framing; load-bearing header, if needed, at 60 in. above the base); clearances 1\/2 in. back and sides, 0 in. top standoffs to header (pp.9-14).\u003c\/li\u003e\n\u003cli\u003eThe fireplace sits 1\/2 in. in front of the framing face; framing across the top sits above the top standoffs; never notch the header.\u003c\/li\u003e\n\u003cli\u003eInstall the four protective hearth strips on combustible floors. Optional outside air: 4 in. duct up to 20 ft or 6 in. up to 40 ft (UL 181 Class 0\/1, P-trap); never draw air from attics, garages or wall cavities.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eChimney \u0026amp; termination\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSL11 11 in. chimney: 14 ft minimum straight (16.5 ft with an offset), 90 ft maximum; listed cap (pp.15-17).\u003c\/li\u003e\n\u003cli\u003eCap bottom at least 3 ft above the roof and 2 ft above anything within 10 ft; at most two offset\/return pairs of no more than 30 degrees.\u003c\/li\u003e\n\u003cli\u003eKeep a 2 in. air space around the chimney; firestop at every floor or every 10 ft of chase.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eShrouds\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eField-built shrouds must be non-combustible sheet metal sized to the manual tables; decorative LDS shrouds are available.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eFinishing\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNon-combustible facing only on the metal face; seal top and side gaps with 300 F non-combustible sealant; let mortar cure 72 hours (pp.27-33).\u003c\/li\u003e\n\u003cli\u003eHearth extension: R-1.03 insulated, non-combustible, 20 in. in front and 12 in. to each side of the opening (HX4 is 66 in. long); see sect. 7 for the finished-hearth height limit.\u003c\/li\u003e\n\u003cli\u003eMantel: combustible mantel up to 12 in. deep at least 12 in. above the opening.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFireplace setup\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eGas logs: up to 100,000 BTU\/h, damper locked fully open; unvented sets only with ANSI Z211.11.2 approval, an automatic shutoff and doors fully open (p.34).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eEveryday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFirst three or four fires should be moderate in size to cure paints and binders; some odor is normal (owner's manual).\u003c\/li\u003e\n\u003cli\u003eKeep the firescreen closed while burning; operate glass doors fully open or fully closed; hot glass and handles cause burns, so supervise children.\u003c\/li\u003e\n\u003cli\u003eInspect the chimney at least annually, or every two months during heavy use, and clean creosote as needed; HHT recommends an NFPA 211 Level 2 inspection by an NFI or CSIA professional.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFollow local, regional, state and national building codes; chimney inspection practice per \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-211-standard-development\/211\"\u003eNFPA 211\u003c\/a\u003e (cited in the owner's manual)\u003c\/li\u003e\n\u003cli\u003eGas log option: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e, CAN\/CGA-B149.1\/.2 in Canada; decorative gas appliances to ANSI Z21.60\/CSA 2.26\u003c\/li\u003e\n\u003cli\u003eNon-combustible materials are defined by ASTM E136 (published by ASTM International)\u003c\/li\u003e\n\u003cli\u003eOutside-air ducting must be UL 181 Class 0 or Class 1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Hearth \u0026amp; Home Technologies (HHT) limited warranty, form 4021-645N (12\/23), printed in the owner's manual 4012-135, Rev P 6\/25. Majestic is an HHT brand.\u003c\/li\u003e\n\u003cli\u003eFirebox and heat exchanger: 20 years parts, 3 years labor.\u003c\/li\u003e\n\u003cli\u003eCastings, medallions and baffles, manifolds, and HHT chimney and terminations: 10 years parts, 3 years labor.\u003c\/li\u003e\n\u003cli\u003eElectrical components (fans, wiring, switches, junction box): 2 years.\u003c\/li\u003e\n\u003cli\u003eCement refractory and glass liner panels: 2 years.\u003c\/li\u003e\n\u003cli\u003eAll parts and material, including handles and external enameled components: 1 year parts and labor (subject to the conditions and exclusions).\u003c\/li\u003e\n\u003cli\u003ePurchased replacement parts and optional accessories: 1 year parts, no labor.\u003c\/li\u003e\n\u003cli\u003eWho is covered: products bought from an HHT authorized dealer or distributor. Coverage transfers to later owners while the fireplace stays at its original installation site, but the period is not extended. Valid only in the country where the selling dealer is authorized.\u003c\/li\u003e\n\u003cli\u003eWhen coverage starts: on the date of installation (new construction: six months after the final sale invoice, and no later than 24 months after HHT ships the product).\u003c\/li\u003e\n\u003cli\u003eHow service works: through the installing dealer or distributor; travel and parts-shipping charges are not covered.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: normal wear items (paint, gaskets, firebricks, grates, flame guides, batteries, glass discoloration), normal finish color changes, damage from improper installation, operation or maintenance, non-HHT components, unauthorized modifications, fuels other than seasoned wood, and power fluctuations. HHT does not guarantee heating capacity for a given space.\u003c\/li\u003e\n\u003cli\u003eThe warranty is void if the fireplace is over-fired (signs include a warped air tube, damaged baffle or deteriorated refractory retainers), exposed to chlorine or other damaging chemicals, or damaged by prolonged dampness, condensation or water from an improper chimney installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including soot and carbon monoxide, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e","brand":"Majestic","offers":[{"title":"Default Title","offer_id":50593312112802,"sku":"DSR42","price":4039.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Screenshot_2026-08-23_163101__35626.1787518505.1280.1280.jpg?v=1791682203"},{"product_id":"majestic-sovereign-36-wood-fireplace-sa36","title":"Majestic Sovereign 36\" Wood Burning Fireplace SA36","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Majestic Sovereign 36\" (SA36) is a traditional wood-burning fireplace with an authentic masonry look, offered in two versions: the SA36R radiant model, which warms the room passively with no fan, and the SA36C heat-circulating model, which moves warm air into the room and accepts the optional FK23 fan kit. It suits homeowners who want a classic, full-size wood fire built into a wall or chase.\u003c\/p\u003e\u003cp\u003eTraditional brick-pattern refractory panels line the firebox, and the firescreen and grate are included. Front choices on the Majestic site include bi-fold glass doors, gasketed cabinet-style glass doors and the Grand Vista mesh front, in black or brushed stainless steel; the circulating owner's manual lists DM1736 bi-fold doors, GGD36BK gasketed doors and GV36BK Grand Vista mesh doors. Majestic's mantels, shelves and stone facings finish the look.\u003c\/p\u003e\u003cp\u003eAs an open wood-burning fireplace, its role is ambiance and warmth near the fire. Choose the radiant SA36R for simple, fan-free radiant heat, or the circulating SA36C if you want the fireplace to push more warm air into the room with the FK23 variable-speed fan kit.\u003c\/p\u003e\u003cp\u003eIt frames in with 3\/4 in. clearance at the back and sides and 0 in. at the top standoffs, and vents through the listed SL300 Series 8 in. chimney from 16.5 ft up to 90 ft. Outside air can be ducted in with 4 in. or 6 in. duct (a CAK4A chimney air kit is required in Canada).\u003c\/p\u003e\u003cp\u003eCompared with the Royalton, the Sovereign is the larger, more versatile wood fireplace: a taller unit, a heat-circulating option with fan, and more door styles. It can also be fitted later with a certified gas log set or log lighter up to 100,000 BTU\/h.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo versions\u003c\/strong\u003e: SA36R radiant (no fan needed) or SA36C heat-circulating (FK23 fan kit optional).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTraditional brick interior\u003c\/strong\u003e: Brick-pattern refractory panels, included (install manual p.8).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirescreen and grate included\u003c\/strong\u003e: Keep the firescreen closed while burning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoor and front choices\u003c\/strong\u003e: Bi-fold glass doors (DM1736), gasketed cabinet-style glass doors (GGD36BK) and Grand Vista mesh doors (GV36BK); black or brushed stainless (circulating owner's manual; majesticproducts.com).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional fan (circulating)\u003c\/strong\u003e: FK23 fan kit with variable-speed control; JK9 junction box included on the circulating model (install manual 4010-262 p.8).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance installation\u003c\/strong\u003e: 3\/4 in. to the back and sides (1\/2 in. at nailing flanges), 0 in. top standoffs (p.10).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSL300 chimney\u003c\/strong\u003e: Listed 8 in. SL300 Series; 16.5 ft minimum, 90 ft maximum (p.15).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutside air option\u003c\/strong\u003e: 4 in. duct up to 20 ft or 6 in. up to 40 ft (ID4\/ID6, UD4\/UD6); CAK4A chimney air kit required in Canada (p.14).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas log provision\u003c\/strong\u003e: Knockouts for 1\/2 in. gas pipe; certified gas logs or a log lighter up to 100,000 BTU\/h (p.34).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinishing options\u003c\/strong\u003e: Majestic wood mantels, cement and wood shelves and natural stone facings (majesticproducts.com).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSleeping rooms\u003c\/strong\u003e: May be installed in sleeping rooms; not approved for manufactured homes (p.4).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed\u003c\/strong\u003e: UL 127 and ULC-S610.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eSA36R (radiant) \/ SA36C (heat-circulating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eWood-burning factory-built (zero-clearance) fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eSeasoned firewood only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOpening width \/ overall width\u003c\/th\u003e\n\u003ctd\u003e36 in. \/ 42 in. (Fig. 3.1, p.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRough framing\u003c\/th\u003e\n\u003ctd\u003e43 in. wide x 41-1\/2 in. high, 23 in. finished cavity depth (Fig. 3.5, p.12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAppliance weight\u003c\/th\u003e\n\u003ctd\u003e175 lb, both versions (p.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChimney\u003c\/th\u003e\n\u003ctd\u003eSL300 Series 8 in.; 16.5 ft minimum (straight or one offset), 20 ft with two offsets, 90 ft maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances\u003c\/th\u003e\n\u003ctd\u003e3\/4 in. back and sides, 0 in. top standoffs, 2 in. around the chimney\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical (circulating fan)\u003c\/th\u003e\n\u003ctd\u003e110-120 VAC, GFCI in damp locations (4010-262 p.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListing\u003c\/th\u003e\n\u003ctd\u003eUL 127 \/ ULC-S610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOpening width 36 in.; overall width 42 in.; weight 175 lb (install manuals p.9).\u003c\/li\u003e\n\u003cli\u003eRough framing 43 in. W x 41-1\/2 in. H; finished cavity depth at least 23 in.; allow 8 in. extra for the outside air connection (p.12).\u003c\/li\u003e\n\u003cli\u003eClearances: 3\/4 in. back and sides (1\/2 in. at nailing flanges), 0 in. top standoffs to header, 2 in. around the chimney; door opening at least 12 in. from a sidewall (p.10).\u003c\/li\u003e\n\u003cli\u003eMantel: combustible, up to 12 in. deep, at least 12 in. above the opening and no lower than 43-1\/2 in. from the fireplace base; trim up to 1-1\/2 in. no closer than 6 in. to the top of the front (pp.32-33).\u003c\/li\u003e\n\u003cli\u003eHearth extension (required): 52 x 16 in. (HX3; 8 in. beyond each side), R-1.03 insulated with a non-combustible surface; non-combustible flooring 16 in. in front and 8 in. at each side. Maximum finished hearth height: 8-1\/16 in. above the floor under the fireplace for the radiant model, 2 in. for the circulating model (pp.28-29).\u003c\/li\u003e\n\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSovereign fireplace with traditional brick refractory panels\u003c\/li\u003e\n\u003cli\u003eFirescreen\u003c\/li\u003e\n\u003cli\u003eGrate\u003c\/li\u003e\n\u003cli\u003eTwo protective metal hearth strips\u003c\/li\u003e\n\u003cli\u003eAttic insulation shield\u003c\/li\u003e\n\u003cli\u003eJK9 junction box (circulating model)\u003c\/li\u003e\n\u003cli\u003eInstallation and owner's manuals\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUnit is complete — no required options needed.\u003c\/li\u003e\n\u003cli\u003eSovereign 36 requires an SL300 chimney venting system, not included with purchase.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDM1736 bi-fold glass doors\u003c\/li\u003e\n\u003cli\u003eGGD36BK gasketed cabinet-style glass doors\u003c\/li\u003e\n\u003cli\u003eGV36BK Grand Vista mesh doors\u003c\/li\u003e\n\u003cli\u003eFK23 fan kit with variable-speed control (circulating model only)\u003c\/li\u003e\n\u003cli\u003eOutside air duct ID4\/ID6 or UD4\/UD6\u003c\/li\u003e\n\u003cli\u003eDecorative shrouds and DTO\/DTS caps\u003c\/li\u003e\n\u003cli\u003eMajestic mantels, shelves and stone facings\u003c\/li\u003e\n\u003cli\u003eCertified gas log set or log lighter (up to 100,000 BTU\/h)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/4010_259.pdf\"\u003eSovereign SA36R\/SA42R (radiant) installation manual 4010-259, Rev P 8\/26\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/4010_262.pdf\"\u003eSovereign SA36C\/SA42C (circulating) installation manual 4010-262, Rev Q 8\/26\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installmanuals\/4010-263A_SA36-42C_Owners_Manual_2-18-15.pdf\"\u003eSovereign SA36C\/SA42C owner's manual 4010-263, Rev U 12\/25, with warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installmanuals\/4010-260A_SA36-42R_Owners_Manual_02-09-15.pdf\"\u003eSovereign SA36R\/SA42R owner's manual 4010-260\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/brochures\/MAJ-1048_WoodBurningFireplace_ProductGuide.pdf\"\u003eMajestic wood-burning fireplace product guide MAJ-1048\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/brochures\/FSF-1016U_Mantels.pdf\"\u003eMantels, shelves and surrounds brochure FSF-1016U\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a wood-burning fireplace. Improper installation, venting or use can cause a house fire or carbon-monoxide exposure. Majestic requires installation by a qualified installer following the installation manual and local building codes (installation manuals 4010-259 and 4010-262), and the chimney should be inspected regularly. Burn only dry, seasoned wood, never use flammable liquids to start or freshen a fire, and keep children and furniture away from hot surfaces.\u003c\/p\u003e\u003ch4\u003eSite and installation requirements\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eIn Canada, the CAK4A chimney air kit is required.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eProduct \u0026amp; safety information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eListed to UL 127 and ULC-S610 for the SL300 chimney; solid wood only; over-firing voids the warranty (pp.4-5, 1).\u003c\/li\u003e\n\u003cli\u003eUse only HHT-approved parts; do not modify the fireplace.\u003c\/li\u003e\n\u003cli\u003eMay be installed in sleeping rooms; not approved for manufactured homes.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGetting started\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eDecide on the radiant or circulating model, the location, chase and chimney route, and whether you want a fan, wall switch or remote (plan the wiring) (pp.5-8).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eFraming \u0026amp; clearances\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eRough framing 43 x 41-1\/2 in., 23 in. cavity depth; the unit sits 1\/2 in. in front of the framing face; never notch the header (pp.9-14).\u003c\/li\u003e\n\u003cli\u003eInstall the two protective hearth strips (about 26 x 4 in.) 2 in. under the front.\u003c\/li\u003e\n\u003cli\u003eOutside air: UL 181 Class 0\/1 duct, 4 in. up to 20 ft or 6 in. up to 40 ft, with a P-trap; never from attics, garages or wall cavities (p.14).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eChimney \u0026amp; termination\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSL300 Series 8 in. chimney (SL306, SL312, SL318, SL324, SL336, SL348 sections; SL315\/SL330 offsets; SL3 stabilizer; FS338\/FS339\/FS340 firestops; AS8 attic shield, CAS8 in Canada; RF370\/RF371 roof flashing) (pp.15-17).\u003c\/li\u003e\n\u003cli\u003e16.5 ft minimum (straight or one offset\/return), 20 ft with two, 90 ft maximum; at most two offset pairs of 30 degrees or less, no more than 20 ft between an offset and its return.\u003c\/li\u003e\n\u003cli\u003eCap bottom at least 3 ft above the roof and 2 ft above anything within 10 ft; listed cap: TR344, TR342-B, ST375, TS345\/TS345P, TCT375 or TR-TVK (p.17).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eChimney installation\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eFirestop at each floor or every 10 ft of chase; CAS8 attic shield required in Canada; seal only where the chimney leaves the warm envelope, with 600 F sealant (pp.18-24).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eShrouds\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eField-built shrouds must follow the manual tables; decorative shrouds and DTO\/DTS caps are available (pp.25-26).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eFinishing\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNon-combustible facing only on the metal face; seal gaps with 300 F non-combustible sealant (pp.27-33).\u003c\/li\u003e\n\u003cli\u003eHearth extension 52 x 16 in. (HX3; 8 in. beyond each side); flooring 16 in. in front and 8 in. at each side; 48 in. hearth depth recommended in front of vinyl floors.\u003c\/li\u003e\n\u003cli\u003eCombustible sidewalls at least 12 in. (circulating manual) \/ 24 in. (radiant manual) from the opening.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eElectrical (circulating model)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eWire and ground the optional FK23 fan to local codes or NFPA 70 \/ CSA C22.1; 110-120 VAC, GFCI-protected in damp locations (4010-262 p.4).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eFireplace setup\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eGas logs or log lighter up to 100,000 BTU\/h with the damper locked open and a gas shutoff. Vented sets: ANSI Z21.60\/CSA 2.26. Unvented sets: ANSI Z21.11.2 with automatic shutoff, glass doors fully open, chimney left in place (p.34).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eEveryday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFirst three or four fires moderate in size so paints and binders cure (owner's manual).\u003c\/li\u003e\n\u003cli\u003eDry, split wood only (about 20% moisture); no gasoline, lighter fluid, trash or scrap lumber; keep the firescreen closed and run glass doors fully open or fully closed.\u003c\/li\u003e\n\u003cli\u003eHave the chimney inspected at least yearly and cleaned as needed.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFollow all local, regional, state and national building codes (installation manual p.6). For chimney inspection HHT recommends at least an NFPA 211 Level 2 inspection by an NFI or CSIA certified professional (owner's manual); see \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-211-standard-development\/211\"\u003eNFPA 211\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eElectrical (circulating fan): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e or CSA C22.1\u003c\/li\u003e\n\u003cli\u003eGas log or log lighter option: \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e in the U.S., CAN\/CGA-B149.1 (natural gas) and B149.2 (propane) in Canada; decorative gas appliances certified to ANSI Z21.60\/CSA 2.26\u003c\/li\u003e\n\u003cli\u003eNon-combustible materials are defined by ASTM E136 (published by ASTM International)\u003c\/li\u003e\n\u003cli\u003eOutside-air ducting must be UL 181 Class 0 or Class 1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Hearth \u0026amp; Home Technologies (HHT) limited warranty, form 4021-645N (12\/23), printed in the Sovereign circulating owner's manual 4010-263, pp.4-5. Majestic is an HHT brand.\u003c\/li\u003e\n\u003cli\u003eFirebox and heat exchanger: 20 years parts, 3 years labor.\u003c\/li\u003e\n\u003cli\u003eCastings, medallions and baffles, manifolds, and HHT chimney and terminations: 10 years parts, 3 years labor.\u003c\/li\u003e\n\u003cli\u003eBurners, logs and metal\/fiber refractory components: 10 years parts, 1 year labor.\u003c\/li\u003e\n\u003cli\u003eElectrical components (fans, wiring, switches, junction box): 2 years.\u003c\/li\u003e\n\u003cli\u003eCement refractory and glass liner panels: 2 years.\u003c\/li\u003e\n\u003cli\u003eAll parts and material, including handles and external enameled components: 1 year parts and labor (subject to the conditions and exclusions).\u003c\/li\u003e\n\u003cli\u003ePurchased replacement parts and optional accessories: 1 year parts, no labor.\u003c\/li\u003e\n\u003cli\u003eWho is covered: products bought from an HHT authorized dealer or distributor. Coverage transfers to later owners while the fireplace stays at its original installation site, but the period is not extended. Valid only in the country where the selling dealer is authorized.\u003c\/li\u003e\n\u003cli\u003eWhen coverage starts: on the date of installation (new construction: six months after the final sale invoice, and no later than 24 months after HHT ships the product).\u003c\/li\u003e\n\u003cli\u003eHow service works: through the installing dealer or distributor; travel and parts-shipping charges are not covered.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: normal wear items (paint, gaskets, firebricks, grates, flame guides, batteries, glass discoloration), normal finish color changes, damage from improper installation, operation or maintenance, non-HHT components, unauthorized modifications, fuels other than seasoned wood, and power fluctuations. HHT does not guarantee heating capacity for a given space.\u003c\/li\u003e\n\u003cli\u003eThe warranty is void if the fireplace is over-fired (signs include a warped air tube, damaged baffle or deteriorated refractory retainers), exposed to chlorine or other damaging chemicals, or damaged by prolonged dampness, condensation or water from an improper chimney installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon black and carbon monoxide, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e","brand":"Majestic","offers":[{"title":"Heat Circulating","offer_id":50593312276642,"sku":"SA36C","price":1619.0,"currency_code":"USD","in_stock":true},{"title":"Radiant","offer_id":50593312309410,"sku":"SA36R","price":1619.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Screenshot_2026-08-23_152202__04389.1787515946.1280.1280.jpg?v=1791682209"},{"product_id":"majestic-lanai-60-outdoor-linear-fireplace-with-intellifire-ignition-system-odlanaig-60","title":"Majestic Lanai 60\" Outdoor Linear Gas Fireplace ODLANAIG-60","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Majestic Lanai 60\" (ODLANAIG-60) is an outdoor linear gas fireplace for covered patios, outdoor kitchens and lanais. A long ribbon of flame dances over clear crystal glass behind a rust-resistant stainless steel front, giving an outdoor room the clean, modern look of an indoor linear fireplace.\u003c\/p\u003e\u003cp\u003eMulticolor LED lighting glows through the glass bed and can stay on with the flame off, so the Lanai doubles as accent lighting on summer nights. Swap the standard crystal glass for Amber, Cobalt, Ebony or Red glass, or finish the fire bed with the CDLS driftwood log set or the STONEKIT stone kit (one or the other, not both).\u003c\/p\u003e\u003cp\u003eIt burns 65,000 BTU\/h on natural gas, or on propane with the LPK-ODLANAIG60 conversion kit. As an outdoor decorative appliance it needs no chimney or vent pipe: it is built into a non-combustible enclosure in an outdoor space and burns in the open air.\u003c\/p\u003e\u003cp\u003eThe IntelliFire electronic ignition monitors the flame for safe operation and saves gas, and the fireplace runs from a wall switch that can be mounted up to 14 ft away. A framed screen barrier, a clean-face trim kit and a drain pan for wet locations are available.\u003c\/p\u003e\u003cp\u003eThe Lanai comes in 48 and 60 in. widths and as a see-through model, so you can match the fire to the size of the space.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor linear design\u003c\/strong\u003e: Ribbon flame over crushed glass behind a stainless steel front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulticolor LED lighting\u003c\/strong\u003e: Outdoor LED lighting under the glass bed, with or without the flame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrystal glass media included\u003c\/strong\u003e: Clear crystal media and deflection glass ship with the unit; a media template is supplied (manual p.25).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedia options\u003c\/strong\u003e: MEDIA-AMBER-48, MEDIA-COBALT-48, MEDIA-EBONY-48 and MEDIA-RED-48 glass (used on both the 48 and 60), CDLS driftwood logs or STONEKIT (not combined) (p.26).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelliFire ignition\u003c\/strong\u003e: Electronic ignition that monitors the flame continuously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall switch control\u003c\/strong\u003e: Wall switch assembly; supplied wire allows mounting up to 14 ft from the appliance (p.20).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo venting needed\u003c\/strong\u003e: Outdoor decorative appliance; no chimney or vent pipe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional screen and trim\u003c\/strong\u003e: ODLANAIG-60SCN framed screen barrier and ODLANAIG-60CFT clean-face trim (p.26).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrain pan option\u003c\/strong\u003e: ODLANAIG-60DP drain pan for wet installations (p.15).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePropane convertible\u003c\/strong\u003e: Factory natural gas; LPK-ODLANAIG60 conversion kit (p.26).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-altitude listed\u003c\/strong\u003e: Listed for high-altitude use (p.4).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: Listed by UL to ANSI Z21.97-2017 \/ CSA 2.41-2017, outdoor decorative gas appliance (p.4).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eODLANAIG-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eOutdoor linear gas fireplace (single-sided)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e64-1\/8\" W x 39-1\/2\" H x 13-3\/8\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003e64-3\/4\" W x 39-3\/4\" H x 13-3\/8\" D, inside a non-combustible enclosure; the header must not sit below the top of the top standoffs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e60\" W x 17\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eCeiling, soffit, veranda or deck above: 39\" minimum from the top of the firebox opening, 60\" below a vinyl soffit or electrical service, 72\" under a vinyl or composite overhang; front: 36\" to combustible objects; side wall: 4\" minimum, one side only; outside corner 9\"; inside corner 4\" (non-vinyl, one side), 8\" (alcove) or 48\" (vinyl siding and windows); windows and doors 12\" (non-vinyl) or 24\" (vinyl); electrical service 24\" to the sides and 12\" above; back and sides: 1\/2\" air space inside the non-combustible enclosure, with non-combustible sheathing above the unit (12\" cement board supplied); floor: 0\" above grade, deck or balcony, on a continuous flat wood, composite or non-combustible base the full width and depth, no hearth extension required; mantel: combustible 18\" to 24\", non-combustible 0\" to 6\" (Fig. 7.1 minimum vertical and maximum horizontal mantel table; its reference points are not published by the manufacturer as labeled values)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e65,000 BTU\/h, natural gas or propane (0-2,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eIntelliFire electronic ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003ctd\u003eWall switch (up to 14 ft of wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLighting\u003c\/th\u003e\n\u003ctd\u003eMulticolor LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eNone (outdoor use only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e110-120 VAC, 60 Hz, under 12 A, GFCI protected, unswitched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. T-handle manual shutoff supplied at the valve inlet; gas access on the left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAppliance weight\u003c\/th\u003e\n\u003ctd\u003e245 lb (manual pp.7-8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eANSI Z21.97-2017 \/ CSA 2.41-2017 outdoor decorative appliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLanai firebox with stainless steel front\u003c\/li\u003e\n\u003cli\u003eClear crystal glass media and deflection glass\u003c\/li\u003e\n\u003cli\u003eMedia template\u003c\/li\u003e\n\u003cli\u003eMulticolor LED lighting\u003c\/li\u003e\n\u003cli\u003eIntelliFire ignition with wall switch assembly\u003c\/li\u003e\n\u003cli\u003e12 in. cement board for minimum-height installs\u003c\/li\u003e\n\u003cli\u003e1\/2 in. T-handle manual gas shutoff\u003c\/li\u003e\n\u003cli\u003eInstallation and owner's manuals\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUnit is complete — no required options needed.\u003c\/li\u003e\n\u003cli\u003ePropane only: the LP conversion kit (the unit ships set up for natural gas).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLPK-ODLANAIG60 propane conversion kit\u003c\/li\u003e\n\u003cli\u003eODLANAIG-60SCN framed screen barrier\u003c\/li\u003e\n\u003cli\u003eODLANAIG-60CFT clean-face trim kit\u003c\/li\u003e\n\u003cli\u003eODLANAIG-60DP drain pan\u003c\/li\u003e\n\u003cli\u003eGlass media MEDIA-AMBER-48, MEDIA-COBALT-48, MEDIA-EBONY-48, MEDIA-RED-48\u003c\/li\u003e\n\u003cli\u003eCDLS driftwood log set or STONEKIT stone kit (one or the other, not both)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/ODLANAIG-48-60_Install_4111-901.pdf\"\u003eLanai 48\/60\/72 installation manual 4111-901, Rev J 12\/25 (English)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/International\/ODLANAIG-48-60_FR_Owners_Manual_4111-900.pdf\"\u003eLanai 48\/60 owner's manual and warranty 4111-900 (French edition; English owner's edition not published online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/Addendums\/ODLANAIG_Conversion_Kit_install_4111-905.pdf\"\u003eLanai propane conversion kit instructions 4111-905\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/Addendums\/ODLANAIG_Overlay_Install_4111-916.pdf\"\u003eLanai overlay instructions 4111-916\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Majestic requires installation and service by a qualified installer, service agency or gas supplier, following the installation manual and local codes (installation manual 4111-901, p.1). If you ever smell gas, do not light any appliance, do not use electrical switches or phones in the building, leave the building and call your gas supplier from a neighbor's phone.\u003c\/p\u003e\u003ch4\u003eSite and installation requirements\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNon-combustible enclosure built to the manual (pp.9-16).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eProduct \u0026amp; safety information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFor outdoor use only; listed by UL as an outdoor decorative gas appliance, ANSI Z21.97-2017 \/ CSA 2.41-2017 (p.4).\u003c\/li\u003e\n\u003cli\u003eDo not install glass doors on this appliance (p.1). Do not burn solid fuel (p.4).\u003c\/li\u003e\n\u003cli\u003eHigh altitude: in the U.S. reduce input 4% per 1,000 ft above 2,000 ft; in Canada no reduction up to 4,500 ft (pp.4, 22).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGetting started\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOutdoor space means: walls with no overhead cover; overhead cover with no more than two side walls; or three side walls with at least 30% of the horizontal perimeter permanently open (p.5; worked example p.27).\u003c\/li\u003e\n\u003cli\u003eOnly 14x18 or 16x18 insect screen; no solar or no-see-um screen (p.5).\u003c\/li\u003e\n\u003cli\u003eThe unit needs a continuous flat base the full width and depth (p.5).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFraming \u0026amp; clearances\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFraming 64-3\/4 in. wide x 39-3\/4 in. high x 13-3\/8 in. deep (p.11).\u003c\/li\u003e\n\u003cli\u003e39 in. overhead; 36 in. to combustibles; 4 in. side wall on one side; corner, window, soffit and electrical-service clearances on p.13.\u003c\/li\u003e\n\u003cli\u003e1\/2 in. air space at back and sides; the header must not sit below the top of the top standoffs (p.14).\u003c\/li\u003e\n\u003cli\u003eAppliance weight 245 lb (pp.7-8).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAppliance preparation\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eLevel side to side and front to back, shimming with non-combustible material (p.16).\u003c\/li\u003e\n\u003cli\u003eSlope chase platforms and hearths 1\/8-1\/4 in. per foot away from the structure; with the drain pan, 1\/4 in. per foot toward the drain ports (pp.15-16).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eElectrical\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e110-120 VAC, 60 Hz, under 12 A, on a GFCI-protected breaker; wire the junction box to unswitched power (p.17).\u003c\/li\u003e\n\u003cli\u003eThe junction box is on the right side and cannot be moved to the left; low and line voltage may not share a wall box (p.17).\u003c\/li\u003e\n\u003cli\u003eWall switch up to 14 ft from the appliance (p.20).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNatural gas inlet 5.0-10.5 in. w.c. (7.0 recommended), manifold 3.5; propane inlet 11-13 in. w.c. (12.0 recommended), manifold 10 (p.21).\u003c\/li\u003e\n\u003cli\u003eA regulator is needed upstream above 1\/2 psi; connect to the supplied 1\/2 in. T-handle shutoff; gas access is on the left (pp.7, 21-22).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinishing\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMantels: combustible 18-24 in., non-combustible 0-6 in. (p.23).\u003c\/li\u003e\n\u003cli\u003eTVs: measure actual TV temperatures at installation; a non-combustible mantel is required (p.24).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAppliance setup\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eRemove the plastic coating and packing; set the deflection glass in its bracket; pour the crystal media evenly over the hearth pan, burner and pilot cover using the media template (p.25).\u003c\/li\u003e\n\u003cli\u003eCDLS and STONEKIT cannot be used together (p.26).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eEveryday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eWind can push the flame forward; keep furniture, cushions and debris clear.\u003c\/li\u003e\n\u003cli\u003eGlass and front get hot; supervise children and pets.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eGas installation: follow local codes or, where none apply, the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e (U.S.) or the \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1 Natural Gas and Propane Installation Code\u003c\/a\u003e (Canada)\u003c\/li\u003e\n\u003cli\u003eElectrical: wire and ground to local codes or, where none apply, the \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e (U.S.) or the \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (Canada)\u003c\/li\u003e\n\u003cli\u003eNon-combustible materials are defined by ASTM E136 (published by ASTM International)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Hearth \u0026amp; Home Technologies limited warranty, form 2108-975C (6\/5\/2019), printed in the Lanai owner's manual 4111-900, pp.4-5. Majestic is an HHT brand.\u003c\/li\u003e\n\u003cli\u003eProduct body, metal firebox and heat exchanger: limited lifetime, from the date of installation.\u003c\/li\u003e\n\u003cli\u003eGas and electrical components and fittings: 1 year from installation.\u003c\/li\u003e\n\u003cli\u003eNickel-plated materials: 1 year (tarnishing excluded).\u003c\/li\u003e\n\u003cli\u003eGlass breakage, and logs, refractory or glass panels that break from thermal shock: 1 year.\u003c\/li\u003e\n\u003cli\u003eVenting, optional accessories and optional glass doors: 1 year.\u003c\/li\u003e\n\u003cli\u003eLabor for warranty service work: 1 year from installation.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original owner and later owners, while the fireplace stays at its original installation site. It must be bought from an authorized HHT dealer.\u003c\/li\u003e\n\u003cli\u003eWhen coverage starts: the latest of the invoice date; for new construction, first occupancy or six months after the dealer sale, whichever comes first; or no later than 24 months after HHT ships the product.\u003c\/li\u003e\n\u003cli\u003eHow service works: warranty service is arranged through the installing dealer (or the nearest authorized HHT dealer). Travel and parts-shipping costs are not covered.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: normal wear items (paint, refractory, grates, flame guards, glass discoloration), normal finish color changes and cosmetic damage, expansion and contraction noise, damage from improper installation or operation, non-HHT parts, unauthorized modifications, power interruptions, and weather or water damage (hail, snow, flooding), prolonged moisture, condensation, ice or snow, and chlorine or fluorine in the air. HHT does not guarantee heating capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — ODLANAIG-60\u003c\/h3\u003e\n\u003ch4\u003eWhat size framing does the ODLANAIG-60 need?\u003c\/h4\u003e\u003cp\u003eThe framed opening is 64-3\/4\" W × 39-3\/4\" H × 13-3\/8\" D, built as a non-combustible enclosure with a 1\/2\" air space at the back and sides and non-combustible sheathing above the unit; a 12\" cement board is supplied. The fireplace sits on a continuous flat wood, composite or non-combustible base that runs its full width and depth.\u003c\/p\u003e\n\u003ch4\u003eDoes it need a chimney or vent pipe?\u003c\/h4\u003e\u003cp\u003eNo. It is an outdoor decorative gas appliance (ANSI Z21.97-2017 \/ CSA 2.41-2017) and burns in the open air. It must go in an outdoor space: walls with no overhead cover, overhead cover with no more than two side walls, or three side walls with at least 30% of the horizontal perimeter permanently open. Keep 39\" from the top of the opening to any ceiling or overhang, or 72\" under vinyl or composite.\u003c\/p\u003e\n\u003ch4\u003eCan the ODLANAIG-60 run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It ships for natural gas and converts with the LPK-ODLANAIG60 kit, installed by a qualified service agency. Input is 65,000 BTU\/h on either gas.\u003c\/p\u003e\n\u003ch4\u003eIs a remote included?\u003c\/h4\u003e\u003cp\u003eNo. It runs from a wired wall switch that ships with it and mounts within 14 ft: the top button cycles ON, HI, MED, LO and OFF, and the bottom button changes the colour of the two 12V outdoor LED light strips. No remote is listed among its accessories.\u003c\/p\u003e\n\u003ch4\u003eCan it get wet?\u003c\/h4\u003e\u003cp\u003eIt sheds moderate amounts of water but is not waterproof, so it must be enclosed or covered with non-combustible finish and all joints sealed. The base has built-in drain holes and the structure must let water drain out; the optional ODLANAIG-60DP drain pan, sloped 1\/4\" per foot toward its drain ports, is recommended. Do not run it if any part has been under water or if snow or debris covers the media.\u003c\/p\u003e\n\u003ch4\u003eWhat's the warranty?\u003c\/h4\u003e\u003cp\u003eThe Hearth \u0026amp; Home Technologies limited warranty covers the product body, metal firebox and heat exchanger for life, gas and electrical components for 1 year, glass breakage for 1 year and warranty labour for 1 year from installation. It covers the original and later owners while the fireplace stays at its first installation site.\u003c\/p\u003e","brand":"Majestic","offers":[{"title":"Default Title","offer_id":50593312833698,"sku":"ODLANAIG-60","price":5009.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Screenshot_2026-08-12_191755__08995.1786578045.1280.1280.jpg?v=1791682221"},{"product_id":"majestic-twilight-traditional-indoor-outdoor-see-through-fireplace-twilight-ift","title":"Majestic Twilight See-Through Gas Fireplace TWILIGHT-IFT","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Majestic Twilight (TWILIGHT-IFT) is an indoor\/outdoor see-through gas fireplace: one side faces the room, the other faces the patio, and the same fire is enjoyed from both. It needs no chimney or vent pipe, because the outdoor face of the fireplace is the termination; it draws combustion air from outside and exhausts outside directly.\u003c\/p\u003e\u003cp\u003eThe fire burns over a six-piece LOGS-MSR log set over lava rock and glowing embers, giving a classic wood-fire look. Majestic built it with the thermal characteristics of a high-quality window system, so the wall stays sealed while the fire connects indoor and outdoor living.\u003c\/p\u003e\u003cp\u003eIt is a decorative appliance (38,000 BTU\/h natural gas, 36,000 BTU\/h propane) certified to ANSI Z21.50-2019 \/ CSA 2.22-2019 and approved for bedrooms. It is not intended as a heat source.\u003c\/p\u003e\u003cp\u003eIntelliFire Touch intermittent pilot ignition controls the fire, with an optional RC400 touchscreen remote, IntelliFire Wi-Fi module, wireless wall switch and battery-backup wall switch kit. An optional fan kit (GFK-160T) is available with the firescreen front.\u003c\/p\u003e\u003cp\u003eInside you finish it with the FS-TWI black firescreen front (floor or raised hearth) or the TWI-MOD black modern front (unit raised at least 3\/4 in.); outside, a non-combustible surround and hood finish the patio side.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor\/outdoor see-through\u003c\/strong\u003e: One fire viewed from the room and the patio.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo vent pipe\u003c\/strong\u003e: The outdoor face is the vent termination; no chimney needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire bed\u003c\/strong\u003e: A six-piece LOGS-MSR log set over lava rock and glowing embers (included).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWindow-grade thermal design\u003c\/strong\u003e: Sealed like a high-quality window system (manual p.8).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelliFire Touch ignition\u003c\/strong\u003e: Intermittent pilot ignition; 6 V system with optional 4 AA battery backup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional RC400 touchscreen remote\u003c\/strong\u003e: Remote on\/off and flame control (IFT-RC400, optional accessory).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart home ready\u003c\/strong\u003e: Optional IFT-WFM Wi-Fi module, IFT-ACM auxiliary module, IFT-RC150 wall switch, BATTERY-WSK.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional fan kit\u003c\/strong\u003e: GFK-160T (not with the TWI-MOD front).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo interior fronts\u003c\/strong\u003e: FS-TWI-BK firescreen or TWI-MOD-BK modern front (one required).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBedroom approved\u003c\/strong\u003e: Decorative appliance, ANSI Z21.50-2019 \/ CSA 2.22-2019.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePropane convertible\u003c\/strong\u003e: LPK-TWI-IFT conversion kit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eTWILIGHT-IFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eIndoor\/outdoor see-through decorative gas fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003eNot published by the manufacturer as labeled values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003e44\" W x 47-5\/8\" H x 23\" D framed opening, interior and exterior; the outdoor face may protrude but must not be recessed into the framing (manual 2668-970 pp.12-13)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e35-5\/8\" W x 21-1\/2\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eCombustible floor 0\", on hard metal or wood the full width and depth of the unit, with combustible flooring no more than 1\" above the base; interior ceiling 35-3\/4\" from the top of the hood; standoffs 9-1\/2\" inside and outside; exterior overhang or soffit 35-5\/16\" (non-vinyl) or 64-5\/16\" (vinyl or composite); 12\" to opening windows and doors, 54\" above public walkways, 3 ft from gas meters; under a deck or porch only with 36\" clearance and open on at least two sides (pp.12-14, 28); side and mantel distances are drawn in Fig. 3.2 and 8.1-8.4 but not published as labeled values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e38,000 BTU\/h natural gas; 36,000 BTU\/h propane (0–2,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eIntelliFire Touch IPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eNone required: terminates through its own outdoor face\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003eUnswitched 110–120 VAC, 14-2 AWG with ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eDecorative gas appliance, ANSI Z21.50-2019 \/ CSA 2.22-2019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eTV above the fireplace\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTV above: Good Faith guidance A 2.5 in., B 2–3 in., C 18 in. (Fig. 2.6, p.9).\u003c\/li\u003e\n\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTwilight firebox with interior and exterior glass\u003c\/li\u003e\n\u003cli\u003eLOGS-MSR six-piece log set, lava rock and glowing embers\u003c\/li\u003e\n\u003cli\u003eIntelliFire Touch ignition\u003c\/li\u003e\n\u003cli\u003eInstallation and owner's manuals\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInterior front: Black Firescreen Front or Black Contemporary (Modern) front; the modern front needs the unit raised 3\/4 in. and cannot be used with the fan kit\u003c\/li\u003e\n\u003cli\u003ePropane only: the LP conversion kit (the unit ships set up for natural gas).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLPK-TWI-IFT propane conversion kit\u003c\/li\u003e\n\u003cli\u003eGFK-160T fan kit\u003c\/li\u003e\n\u003cli\u003eIFT-RC400 remote, IFT-RC150 wall switch, BATTERY-WSK, IFT-WFM Wi-Fi module, IFT-ACM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/2668_970_TWILIGHT-IFT_INSTALL.pdf\"\u003eTWILIGHT-IFT installation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/2668_971_TWILIGHT-IFT_OWNER.pdf\"\u003eTWILIGHT-IFT owner's manual (warranty pp.4–6)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Majestic requires installation and service by a qualified installer, service agency or gas supplier, following the installation manual and local codes (installation manual 2668-970, p.4). If you ever smell gas, do not light any appliance, do not use electrical switches or phones in the building, leave the building and call your gas supplier from a neighbor's phone.\u003c\/p\u003e\u003ch4\u003eProduct \u0026amp; safety information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDecorative gas appliance, ANSI Z21.50-2019 \/ CSA 2.22-2019; not a heat source; bedroom approved (p.4).\u003c\/li\u003e\n\u003cli\u003eU.S.: reduce input 4% per 1,000 ft above 2,000 ft (p.5).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGetting started: outdoor space\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eThe outdoor side must face an outdoor space: no roof, or a roof with no more than two walls, or three\/four walls with at least 30% of the perimeter permanently open (p.7).\u003c\/li\u003e\n\u003cli\u003eOnly 14x18 or 16x18 mesh screening on open sides; no solar or no-see-um screen (p.7).\u003c\/li\u003e\n\u003cli\u003eWall-temperature and TV guidance on pp.8–9.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFraming \u0026amp; clearances\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eFramed opening 44 x 47-5\/8 x 23 in. (p.12); floor protection p.13.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eTermination clearances\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eOutdoor face clearances to soffits, windows, corners, meters and walkways per Fig. 4.1 (p.14).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eAppliance preparation\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eFlash and seal the exterior with 300°F silicone; materials near the top and sides rated 225°F; non-combustible exterior facing with a hood (pp.15–18).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eElectrical\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUnswitched 110–120 VAC, 14-2 AWG with ground; GFCI where required (pp.19–21).\u003c\/li\u003e\n\u003cli\u003e6 V transformer for normal use; 4 AA battery pack for emergencies only (p.21).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eNG inlet 5.0–10.0 in. w.c., manifold 3.5; propane inlet 11.0–13.0, manifold 10.0 (p.22).\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eFinishing\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eMantel and projection limits Fig. 8.1–8.4 (p.24); fronts pp.25–27; facing pp.28–31.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eAppliance setup\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCover the pan with lava rock, place glowing embers and the LOGS-MSR logs as shown (pp.33–35).\u003c\/li\u003e\n\u003cli\u003eStartup p.36.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFirst fire \u0026amp; everyday use\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBreak-in: run on high 3–4 hours, cool, clean the glass, repeat if odor persists (owner's manual).\u003c\/li\u003e\n\u003cli\u003eBoth glass faces get hot; keep the front installed and children supervised.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eGas installation: follow local codes or, where none apply, the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e (U.S.) or the \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1 Natural Gas and Propane Installation Code\u003c\/a\u003e (Canada)\u003c\/li\u003e\n\u003cli\u003eElectrical: wire and ground to local codes or, where none apply, the \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e (U.S.) or the \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (Canada)\u003c\/li\u003e\n\u003cli\u003eManufactured (mobile) homes: OEM installation to the \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\"\u003eManufactured Home Construction and Safety Standard, Title 24 CFR Part 3280\u003c\/a\u003e (U.S.) or \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/2703320\/\"\u003eCAN\/CSA Z240 MH Series\u003c\/a\u003e (Canada)\u003c\/li\u003e\n\u003cli\u003eMassachusetts: installation by a licensed plumber or gas fitter under the \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003eMassachusetts fuel gas code (248 CMR)\u003c\/a\u003e; side-wall vents under 7 ft need a hard-wired CO detector with battery backup meeting \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034\u003c\/li\u003e\n\u003cli\u003eNon-combustible materials are defined by ASTM E136 (published by ASTM International)\u003c\/li\u003e\n\u003cli\u003eAttic insulation shield where the vent passes an insulated attic, per the International Fuel Gas Code (ICC)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCoverage is the Hearth \u0026amp; Home Technologies limited warranty, form 2108-975C (6\/5\/2019), printed in the TWILIGHT-IFT owner's manual 2668-971 Rev G, pp.4–6.\u003c\/li\u003e\n\u003cli\u003eProduct body, metal firebox and heat exchanger: limited lifetime, from the date of installation.\u003c\/li\u003e\n\u003cli\u003eGas and electrical components and gaskets: 1 year from installation.\u003c\/li\u003e\n\u003cli\u003eGlass breakage, and logs, refractory or glass panels that break from thermal shock: 1 year (hairline cracks, scratches and slight color change excluded).\u003c\/li\u003e\n\u003cli\u003eVenting, optional accessories and optional glass doors: 1 year.\u003c\/li\u003e\n\u003cli\u003eLabor for warranty service work: 1 year from installation.\u003c\/li\u003e\n\u003cli\u003eCoverage starts on the date of installation (new construction: occupancy or six months after the dealer sale, and no later than 24 months after HHT ships the product). Products must be bought from an authorized HHT dealer and stay at the original installation site.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: improper installation, operation or maintenance; damage from weather or water; use of non-HHT parts or venting; normal wear and finish changes; installation or removal costs. Warranty service is arranged through the installing dealer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — TWILIGHT-IFT\u003c\/h3\u003e\n\u003ch4\u003eWhat size framing does the TWILIGHT-IFT need?\u003c\/h4\u003e\u003cp\u003eThe framed opening is 44\" W × 47-5\/8\" H × 23\" D, the same on the interior and exterior. The unit sits on hard metal or wood that runs its full width and depth, never directly on carpet, vinyl or tile. The outdoor face may stick out past the wall but must not be recessed into the framing.\u003c\/p\u003e\n\u003ch4\u003eDoes it need a chimney or vent pipe?\u003c\/h4\u003e\u003cp\u003eNo. The outdoor face is the vent termination, so it draws combustion air from outside and exhausts outside directly. Outside, keep 35-5\/16\" below a non-vinyl soffit or 64-5\/16\" below vinyl, 12\" from opening windows and doors and 3 ft from gas meters. Under a deck or porch it needs 36\" of clearance and at least two open sides, and a covered patio with three or four walls must keep 30% of its perimeter permanently open.\u003c\/p\u003e\n\u003ch4\u003eDoes it heat the room?\u003c\/h4\u003e\u003cp\u003eIt is certified as a decorative gas appliance (ANSI Z21.50 \/ CSA 2.22), so it is built for the view rather than as a heat source. Input is 38,000 BTU\/h on natural gas and 36,000 BTU\/h on propane up to 2,000 ft.\u003c\/p\u003e\n\u003ch4\u003eCan the TWILIGHT-IFT run on propane?\u003c\/h4\u003e\u003cp\u003eYes. It converts with the LPK-TWI-IFT propane conversion kit, installed by a qualified service technician.\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes, for emergencies. With four AA batteries (not included) in the battery pack, the IntelliFire Touch ignition keeps the fire running; the fan and lights need household power and stay off until it returns. Normal operation runs on an unswitched 110-120 VAC circuit.\u003c\/p\u003e\n\u003ch4\u003eIs a remote included?\u003c\/h4\u003e\u003cp\u003eNo, a remote is optional. Choices are the IFT-RC400 touchscreen remote, the IFT-RC150 control, a wired wall switch, and the IFT-WFM Wi-Fi module for app control.\u003c\/p\u003e","brand":"Majestic","offers":[{"title":"Default Title","offer_id":50593312932002,"sku":"TWILIGHT-IFT","price":7729.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Majestic-Twilight-Traditional-IndoorOutdoor-See-Through-Fireplace-TWILIGHT-IFT_2186__70427.1785129477.1280.1280.jpg?v=1791682223"},{"product_id":"breckwell-vent-free-gas-stove-bh32vfp","title":"Breckwell Vent-Free Gas Stove BH32VF","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eClassic cast iron styling makes this beautiful stove the perfect heating appliance for your living space. The BH32VF gas stove delivers 31,000 BTUs of heat. Because it does not require a vent, it is 99 percent efficient- so you get your moneys worth every time you use this stove. Friends and family alike will be drawn to the classic design of this antique style stove and are guaranteed to enjoy the warmth it provides. The log set is included with this stove to give you a very realistic fire look. In addition, this stove does not need electricity to operate, meaning it is the perfect stove to own if the power is out. Standard operation is simple, just turn the switch on, select your heat output and enjoy the warmth. This stove can be hooked up to any standard millivolt thermostat allowing it to cycle on and off as needed. complete with logs and liner.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFeatures \u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeats up to 1200 square feet\u003c\/li\u003e\n\u003cli\u003e31,000 BTUs\u003c\/li\u003e\n\u003cli\u003eHeight: 28.75\"\u003c\/li\u003e\n\u003cli\u003eWidth: 26.5\"\u003c\/li\u003e\n\u003cli\u003eDepth: 25.5\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIncludes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLogs\u003c\/li\u003e\n\u003cli\u003eLiner\u003c\/li\u003e\n\u003cli\u003eOptional Accessory: B150 Blower\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003ca style=\"color: #ff0000;\" title=\"Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/2129\/3073\/files\/853753---BH32VF.pdf?v=1769094524\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eOwners Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003e\u003ca style=\"color: #ff0000;\" title=\"Warranty\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/2129\/3073\/files\/Warranty.pdf?v=1769094502\" target=\"_blank\" rel=\"noopener\"\u003eWarranty\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Breckwell","offers":[{"title":"Propane","offer_id":50594678145186,"sku":"BH32VFP","price":2599.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas","offer_id":50594678177954,"sku":"BH32VFN","price":2599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Breckwell-Vent-Free-Gas-Stove-BH32VF_6286__11560.1785133329.1280.1280.jpg?v=1791732070"},{"product_id":"modern-flames-redstone-36-traditional-electric-fireplace-rs-3626","title":"Modern Flames Redstone 36\" Electric Fireplace RS-3626","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Modern Flames Redstone 36\" (RS-3626) is a traditional-format electric firebox that works two ways: slide it into an existing wood-burning fireplace as an insert, or frame it into a wall for a flush built-in look. As an insert it simply plugs into an outlet inside the old firebox; as a built-in it is hardwired by an electrician into a framed opening about 10 in. deep.\u003c\/p\u003e\u003cp\u003eModern Flames' Hybrid-FX flame technology maximizes flame height in an enlarged vertical viewing area, so the Redstone reads like a real fire rather than a thin strip of light. Flames, ember bed and downlight are available in ten independently controlled colors plus a fade mode, with four flame speeds and five brightness levels, over a glowing driftwood log set and glacier crystals.\u003c\/p\u003e\u003cp\u003eThe fan-forced heater gives 5,000 BTU (1,465 W) of supplemental zone heat, with low (733 W) and high settings, adjustable temperature control and a 30 minute to 8 hour timer. Modern Flames rates the Redstone insert for supplemental heat in spaces up to about 500 sq ft. The heater only runs with the flame on, and the flame can run on its own all year.\u003c\/p\u003e\u003cp\u003eEverything is controlled from the touch panel at the upper right or the included remote. Two trims come in the box: a 5\/8 in. trim fitted at the factory and a wider 1-5\/8 in. trim for openings that need more coverage; optional extra-wide surrounds (TK-RS36-4128 small, TK-RS36-4530 large) and a TruWood timber kit are available.\u003c\/p\u003e\u003cp\u003eWithin the Modern Flames range, the Redstone is the plug-in-or-hardwire traditional firebox: a straightforward way to convert an existing fireplace to electric, or to build a realistic traditional fire into a new wall.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsert or built-in\u003c\/strong\u003e: plugs into an outlet inside an existing fireplace (held by gravity and friction, no screws), or hardwires into a framed wall opening (manual pp.8-15).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHybrid-FX flame technology\u003c\/strong\u003e: maximizes flame height in an enlarged vertical viewing area (Modern Flames product page).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTen flame colors\u003c\/strong\u003e: ten colors plus a fade mode, with memory of the last setting (pp.16-19).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmber bed lighting\u003c\/strong\u003e: ten colors plus a fade mode, brightness L5 to off, independent of the flame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDownlight\u003c\/strong\u003e: ten colors plus fade, or off (remote).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame speed and brightness\u003c\/strong\u003e: four flame speeds; flame brightness F5 to off; logs can be switched off with a 5-second press.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlowing log set and glacier crystals\u003c\/strong\u003e: driftwood logs and small glacier crystals are included (p.4).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupplemental heat\u003c\/strong\u003e: 5,000 BTU (1,465 W); H1 low 733 W, H2 high 1,465 W; fan runs 8-10 seconds before and after heating; up to about 500 sq ft (Modern Flames insert literature).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature control\u003c\/strong\u003e: adjustable setting 0-10 on the display, switchable between F and C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeater lock\u003c\/strong\u003e: hold 5 seconds to lock the heater and thermostat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTimer\u003c\/strong\u003e: 30 minutes to 8 hours (default 0.5 h).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHome button\u003c\/strong\u003e: returns all settings to factory defaults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTouch panel and remote\u003c\/strong\u003e: upper-right touch control panel plus a remote with CR2025 battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo trims included\u003c\/strong\u003e: 5\/8 in. (16 mm) trim fitted, 1-5\/8 in. (41 mm) trim in the box; extra-wide surrounds sold separately for the 26, 30 and 36 in. models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero clearance sides, back and bottom\u003c\/strong\u003e: 0 in. to combustibles at the sides, back and bottom; 11.8 in. above the glass to a mantel or ceiling (p.7).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature limiting control\u003c\/strong\u003e: shuts the heater off automatically if it overheats (p.20).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame without heat\u003c\/strong\u003e: the flame display runs with the heater off.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eModern Flames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eRS-3626\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRedstone (traditional built-in or insert)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit with 5\/8 in. trim (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e33-3\/4 x 24 x 9-7\/8 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit with 1-5\/8 in. trim (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e35-3\/4 x 26 x 9-7\/8 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area (approx. W x H)\u003c\/th\u003e\n\u003ctd\u003e32-3\/8 x 20-1\/2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBuilt-in opening (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e32-5\/8 x 23-7\/8 x 10 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e120 V AC, 60 Hz, 1,465 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat output\u003c\/th\u003e\n\u003ctd\u003e5,000 BTU; low 733 W \/ high 1,465 W; up to about 500 sq ft supplemental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCircuit\u003c\/th\u003e\n\u003ctd\u003eDedicated 15 A (or larger); plug-in for insert, hardwired for built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlame and lighting\u003c\/th\u003e\n\u003ctd\u003e10 colors plus fade for flame, ember bed and downlight; 4 flame speeds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControls\u003c\/th\u003e\n\u003ctd\u003eUpper-right touch panel and remote (CR2025)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTimer\u003c\/th\u003e\n\u003ctd\u003e30 minutes to 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eNot published by Modern Flames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cp\u003eFigures below are from the Redstone built-in (or insert) owner's manual, REV 2023.05.04.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUnit with the fitted 5\/8 in. (16 mm) trim: 33-3\/4 x 24 x 9-7\/8 in. W x H x D (manual p.5).\u003c\/li\u003e\n\u003cli\u003eUnit with the 1-5\/8 in. (41 mm) trim: 35-3\/4 x 26 x 9-7\/8 in. W x H x D (manual p.6: the wider trim adds 2 in. to width and height).\u003c\/li\u003e\n\u003cli\u003eViewing area: about 32-3\/8 x 20-1\/2 in. W x H (manual p.5 drawing).\u003c\/li\u003e\n\u003cli\u003eBuilt-in finished opening: 32-5\/8 x 23-7\/8 x 10 in. W x H x D (p.8).\u003c\/li\u003e\n\u003cli\u003eClearances from the glass front: 0 in. bottom, sides and back; 11.8 in. (300 mm) to a mantel and to the ceiling (p.7).\u003c\/li\u003e\n\u003cli\u003eInsert installation: the unit rests in the existing firebox by gravity and friction; check the dimensional drawing against your opening (p.13).\u003c\/li\u003e\n\u003cli\u003eWeight: not published by Modern Flames.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRedstone fireplace with front glass and factory-fitted 5\/8 in. (16 mm) trim\u003c\/li\u003e\n\u003cli\u003e1-5\/8 in. (41 mm) trim kit\u003c\/li\u003e\n\u003cli\u003eDriftwood log set\u003c\/li\u003e\n\u003cli\u003eSmall glacier crystals\u003c\/li\u003e\n\u003cli\u003eRemote control with CR2025 battery\u003c\/li\u003e\n\u003cli\u003eScrews, screw covers and hardware kit\u003c\/li\u003e\n\u003cli\u003eInstruction manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eA dedicated circuit with a 15 A (or larger) breaker, not shared with other appliances (manual p.7)\u003c\/li\u003e\n\u003cli\u003eInsert installation: a grounded 110-120 V, 15 A outlet installed by an electrician at the rear or side of the existing firebox (p.13)\u003c\/li\u003e\n\u003cli\u003eBuilt-in installation: hardwiring by a qualified electrician, with a cover plate and box connector (pp.8-9)\u003c\/li\u003e\n\u003cli\u003eBuilt-in installation: a framed opening sized to the table below\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTruWood Timber Kit\u003c\/strong\u003e: Modern Flames 36\", TRUWOOD PREMIUM TIMBER KIT, LARGE TWL-36-SP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurround\u003c\/strong\u003e: Modern Flames Redstone 36-Inch Small Surround TK-RS36-4128; Modern Flames Redstone 36-Inch Large Surround TK-RS36-4530\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is an electric heater. Incorrect wiring, framing or use can cause fire, electric shock or injury. Any hardwired connection must be made by a qualified electrician, and the fireplace must be installed exactly as the Modern Flames manual describes. Keep furniture, curtains, bedding and other combustibles at least 3 ft (0.9 m) from the front, never block the air inlets or heater outlet, and remember the glass and heater outlet get hot.\u003c\/p\u003e\u003ch4\u003eImportant safety information (manual pp.2-3)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSupplemental heat only; indoor use only. Never use an extension cord or power strip, and never use it in bathrooms, laundry rooms or anywhere it could get wet.\u003c\/li\u003e\n\u003cli\u003eDo not operate after a malfunction; disconnect power and have a qualified electrician inspect it. If the alarm sounds, turn it off and clear the blockage before reuse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003ePreparation and parts (pp.3-4)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eCheck the parts list. Tools: Phillips screwdriver, stud finder, level, tape measure, drill with 1\/4 in. bit and hammer.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eSpecifications and dimensions (pp.5-6)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eRated 120 V AC, 60 Hz, 1,465 W (5,000 BTU). Dimensions with each trim are listed under Dimensions and clearances above.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003ePower, location and clearances (p.7)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUse a dedicated 15 A (or larger) circuit. Clearances measured from the glass front: 0 in. at the bottom, sides and back; 11.8 in. (300 mm) to a mantel and to the ceiling.\u003c\/li\u003e\n\u003cli\u003eLocate the unit at least 36 in. from drapes, furniture, bedding and paper; a mantel finish must be heat-resistant paint or lacquer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilt-in installation (pp.8-12)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eFrame the finished opening to the table above, have the unit hardwired by a qualified electrician, then secure it with four screws through the side holes and fit the screw covers. Install the logs, then the glacier crystals, then the glass.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eInsert installation (pp.13-15)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eClean the existing firebox, have an electrician install a grounded outlet at its rear or side, plug in and slide the unit in; it rests in place without screws. Consult a local builder and follow local codes before installing.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eOperation (pp.16-19)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eTouch panel at the upper right or the remote; heater runs only with the flame on. A slight odor on first use is normal.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eTemperature limiting control and battery (p.20)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eIf the heater shuts off, unplug for 5 minutes, clear the vents and restore power; if it repeats, have the outlet and wiring inspected. The remote uses one CR2025 battery.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eCare and maintenance (p.21)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eUnplug before cleaning; never spray or immerse. Glass cleaner on a cloth, soft soapy cloth for the trim (no brass polish), vacuum the vents regularly.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eOptional extra-wide trim (pp.22-23)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eExtra-wide surrounds for the 26, 30 and 36 in. models attach as shown in the manual and the extra-wide trim instructions.\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eHardwiring must follow the \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNFPA 70 \/ ANSI National Electrical Code (NEC)\u003c\/a\u003e in the USA or the \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e in Canada, and local codes (manual pp.7, 9, 13).\u003c\/li\u003e\n\u003cli\u003eConsult a local builder and follow local codes before installing (manual p.13).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSource: Modern Flames LLC Limited Warranty (\u003ca href=\"https:\/\/www.modernflames.com\/wp-content\/uploads\/2024\/10\/MODERN-FLAMES-warranty-2022-2023.pdf\"\u003ewarranty statement\u003c\/a\u003e); the installation manuals contain no separate warranty terms.\u003c\/li\u003e\n\u003cli\u003eStandard limited warranty: 2 years from the date of purchase.\u003c\/li\u003e\n\u003cli\u003eExtended warranty: 5 years from the date of purchase when the product is registered at modernflames.com.\u003c\/li\u003e\n\u003cli\u003eIntegrated LCD screens: 1 year from the date of purchase.\u003c\/li\u003e\n\u003cli\u003eLabor: a one-time service credit of up to $100 during the first year (trip or driving fees are not covered); contact Modern Flames before any service is performed.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original purchaser of a product bought from an authorized Modern Flames dealer or distributor on or after 9\/1\/2021. The warranty is not transferable.\u003c\/li\u003e\n\u003cli\u003eHow claims work: contact Modern Flames first with the serial number, purchase date, selling dealer and a description of the issue (photos or video for any visible damage). Parts must be Modern Flames parts, and a return authorization is needed before anything is shipped back. Modern Flames may repair, replace or refund at its discretion, up to the purchase price.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: consumable parts and normal wear; acts of nature, power outages and power surges; installation or use that does not follow the instructions or local codes; damage from removal or reinstallation, poor maintenance, unauthorized modifications, aftermarket parts or rewiring; prolonged dampness or condensation; outdoor installation of a product (or arrangement) not approved for outdoor use; and switching off or disconnecting power during Wi-Fi pairing or software updates.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eManufacturer manuals and downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.modernflames.com\/wp-content\/uploads\/2024\/10\/Redstone-36-3626-with-16mm-trim.pdf\"\u003eRS-3626 dimensional drawing with 5\/8 in. trim\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.modernflames.com\/wp-content\/uploads\/2026\/05\/Redstone-36-RS-3626-with-dims-with-41mm-trim-1.pdf\"\u003eRS-3626 dimensional drawing with 1-5\/8 in. trim\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.modernflames.com\/wp-content\/uploads\/2024\/10\/Redstone-USA-owners-manual.pdf\"\u003eRedstone owner's and installation manual (English, May 2023)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.modernflames.com\/wp-content\/uploads\/2024\/10\/Manuel-Redstone-Fireplace-Fr-Can-2023.pdf\"\u003eRedstone owner's manual (French Canadian)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.modernflames.com\/wp-content\/uploads\/2024\/10\/REDSTONE-INSERT-FLYER-2021_LR.pdf\"\u003eRedstone insert flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.modernflames.com\/wp-content\/uploads\/2024\/10\/REDSTONE-BUILT-IN-FLYER-2021_LR.pdf\"\u003eRedstone built-in flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/modernflames.com\/wp-content\/uploads\/2024\/08\/Redstone-Series-COMBO-2022-web.pdf\"\u003eRedstone series brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.modernflames.com\/wp-content\/uploads\/2024\/10\/REDSTONE-SERIES-TRIM-OPTIONS-12.2020.pdf\"\u003eRedstone surround options and dimensions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.modernflames.com\/wp-content\/uploads\/2024\/10\/MF-RedStone-Extra-Wide-Trim-Instructions-9.2020-copy.pdf\"\u003eExtra-wide trim installation instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.modernflames.com\/wp-content\/uploads\/2024\/10\/MF-Remote-guide-REDSTONE.pdf\"\u003eRedstone remote control guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.modernflames.com\/wp-content\/uploads\/2024\/10\/MODERN-FLAMES-warranty-2022-2023.pdf\"\u003eModern Flames limited warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions — RS-3626\u003c\/h3\u003e\u003ch4\u003eWhat is the built-in opening for RS-3626?\u003c\/h4\u003e\u003cp\u003eThe finished opening is 32 5\/8\" W × 23 7\/8\" H × 10\" D (829 × 607 × 254 mm).\u003c\/p\u003e\u003ch4\u003eAre both standard trims included?\u003c\/h4\u003e\u003cp\u003eYes. The 5\/8\" (16 mm) trim is preinstalled and the 1 5\/8\" (41 mm) trim is supplied in the box. Extra-wide surrounds are separate accessories.\u003c\/p\u003e\u003ch4\u003eCan the flame display run without heat?\u003c\/h4\u003e\u003cp\u003eYes. The heater-off setting leaves the decorative flame display available.\u003c\/p\u003e\u003ch4\u003eDoes an insert installation require hardwiring?\u003c\/h4\u003e\u003cp\u003eThe insert method uses the supplied cord and a dedicated grounded receptacle in the existing fireplace. A new built-in installation uses a hardwired connection.\u003c\/p\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e","brand":"Modern Flames","offers":[{"title":"Default Title","offer_id":50622198382754,"sku":"RS-3626","price":1499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Modern-Flames-Redstone-36-Traditional-Electric-Fireplace-RS-3626_2324__02818.1785133220.1280.1280.jpg?v=1791992045"},{"product_id":"osburn-stratford-ii-zero-clearance-wood-fireplace-insert-ob04007","title":"Osburn Stratford II Zero-Clearance Wood Fireplace OB04007","description":"\u003ch2\u003eOsburn Stratford II Zero Clearance Wood Fireplace Insert\u003c\/h2\u003e\n\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Osburn Stratford II OB04007 is a zero-clearance wood-burning fireplace that is framed into a wall or chase, for living rooms, family rooms and homes of 750 to 2,200 sq. ft. that want a real wood fire that also heats. It sits with 0\" clearance to the enclosure at the back, sides and floor and vents straight up through a 6\" UL 103 HT chimney.\u003c\/p\u003e\u003cp\u003eDouble doors with cast iron frames and ceramic glass give a 22-1\/4\" x 12-1\/2\" view of the fire over cast iron andirons and moulded refractory brick. It is finished with a traditional (OA10255) or modern (OA10256) faceplate and a black (OA10610) or brushed nickel (OA10612) door overlay, and the optional AC01275 fire screen lets you enjoy it with the doors open.\u003c\/p\u003e\u003cp\u003eThe 2.5 cu. ft. non-catalytic firebox takes logs up to 20\" and burns up to 8 hours, with an output of 12,700 to 60,700 BTU\/h and up to 80,000 BTU\/h. It meets the EPA 2020 standard at 1.2 g\/h. A 176 CFM blower is included, and optional gravity or forced air kits can carry heat to other rooms. It is not approved for mobile or manufactured homes.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-catalytic combustion technology.\u003c\/li\u003e\n\u003cli\u003eHigh-efficiency certified appliance: Yes, EPA 2020 approved.\u003c\/li\u003e\n\u003cli\u003eStainless-steel secondary-air system for cleaner secondary combustion.\u003c\/li\u003e\n\u003cli\u003eGlass air-wash system to help keep the view of the fire clear.\u003c\/li\u003e\n\u003cli\u003eMoulded refractory bricks.\u003c\/li\u003e\n\u003cli\u003eCast iron andirons.\u003c\/li\u003e\n\u003cli\u003eDoor: Double, glass with cast iron frame; ceramic glass.\u003c\/li\u003e\n\u003cli\u003eBlower included (176 CFM).\u003c\/li\u003e\n\u003cli\u003eBaffle: C-Cast or equivalent.\u003c\/li\u003e\n\u003cli\u003eZero clearance to the enclosure at the back, sides and floor; 2\" around the chimney\u003c\/li\u003e\n\u003cli\u003e2.5 cu. ft. firebox (1.94 cu. ft. EPA loading volume); 16\" logs recommended, 20\" maximum, loaded east-west\u003c\/li\u003e\n\u003cli\u003eUp to 8 hours of burn time; 12,700 to 60,700 BTU\/h output, 80,000 BTU\/h maximum\u003c\/li\u003e\n\u003cli\u003eBlower runs automatically when the fireplace warms up or manually, with variable speed\u003c\/li\u003e\n\u003cli\u003eOptional AC01375 traditional or AC01389 modern gravity kit, or AC01374 forced air kit, to send heat to other rooms\u003c\/li\u003e\n\u003cli\u003eFresh air intake ready (4\" opening on the right side or underneath)\u003c\/li\u003e\n\u003cli\u003eListed to UL 127\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHeating Performance and Efficiency\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended heating area\u003c\/th\u003e\n\u003ctd\u003e750 - 2,200 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum heat output\u003c\/th\u003e\n\u003ctd\u003e80,000 BTU\/h (23.4 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall heat output rate\u003c\/th\u003e\n\u003ctd\u003e12,700 BTU\/h (3.72 kW) to 60,700 BTU\/h (17.79 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum burn time\u003c\/th\u003e\n\u003ctd\u003e8 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall firebox volume\u003c\/th\u003e\n\u003ctd\u003e2.5 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEPA loading volume\u003c\/th\u003e\n\u003ctd\u003e1.94 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAverage overall efficiency\u003c\/th\u003e\n\u003ctd\u003e64% (HHV) \/ 68% (LHV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptimum overall efficiency\u003c\/th\u003e\n\u003ctd\u003e70%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptimum heat transfer efficiency\u003c\/th\u003e\n\u003ctd\u003e68%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAverage particulate emissions\u003c\/th\u003e\n\u003ctd\u003e1.2 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAverage CO\u003c\/th\u003e\n\u003ctd\u003e98 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eValues are as measured per the test method, except the recommended heating area, firebox volume, maximum burn time and maximum heat output, which are manufacturer estimates. Location in the home, chimney draft, heat loss, climate and fuel all affect actual performance.\u003c\/p\u003e\n\u003ch3\u003eDimensions and Firebox Details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e36-3\/4\" W x 40-5\/8\" H x 29-3\/4\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eFraming 37-3\/4\" W x 41-5\/8\" H to the first header x 24-7\/8\" D, with 80\" total height and the space above the fireplace left empty to 80\" from the base; framing 60-3\/4\" wide with the fresh air intake, 72-3\/4\" wide with the forced air kit; add the thickness of any finish inside the enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003eGlass 22-1\/4\" W x 12-1\/2\" H (two cast iron framed doors); door opening 25-3\/8\" W x 10-1\/2\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eEnclosure back, sides and floor 0\"; chimney 2\"; ceiling 80\" above the base of the fireplace; side wall 13\" from the door opening; side mantel no deeper than 3\" and at least 8\" from the door opening; wall in front of the fireplace 36\" (USA). Combustible shelf above, measured from the base: 6\" deep at 58\", 8\" at 60\", 10\" at 62\", 12\" at 64\" (with the AC01223 heat shield: 50\" to 56\"; non-combustible shelf at least 48\"). Floor protection: continuous non-combustible, 16\" in front and 8\" past each side of the door opening (41-1\/2\" wide), R 1.00 when the fireplace sits on the floor or is raised 4\" or less; no R value when raised more than 4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox dimensions\u003c\/th\u003e\n\u003ctd\u003e12 1\/8\" H × 20 3\/8\" W × 12 7\/8\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum log length\u003c\/th\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLog positioning\u003c\/th\u003e\n\u003ctd\u003eLoading over width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue outlet diameter\u003c\/th\u003e\n\u003ctd\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e468 lb (212 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eStratford II fireplace with double cast iron framed doors and ceramic glass\u003c\/li\u003e\n\u003cli\u003e44122 double cage blower, 176 CFM\u003c\/li\u003e\n\u003cli\u003eC-Cast baffle, stainless secondary air tubes, moulded refractory brick and cast iron andirons\u003c\/li\u003e\n\u003cli\u003eFraming standoffs\u003c\/li\u003e\n\u003cli\u003eFresh air kit: 4\" adapter, air intake plate and four screws\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne faceplate (not included in the base price): OA10255 traditional or OA10256 modern\u003c\/li\u003e\n\u003cli\u003eOne door overlay (not included in the base price): OA10610 black or OA10612 brushed nickel\u003c\/li\u003e\n\u003cli\u003eA 6\" chimney listed to UL 103 HT from Osburn's approved list, at least 15 ft from the base of the fireplace to the cap (17 ft with four elbows). DuraVent DuraTech is approved; the store carries DuraTech 6\" lengths 6DT-06, 6DT-09, 6DT-12, 6DT-18, 6DT-24, 6DT-36, 6DT-48 (6DT-06SS to 6DT-48SS stainless; 6DT-06B to 6DT-12B black)\u003c\/li\u003e\n\u003cli\u003eDuraTech 6\" offsets, where needed: 6DT-E30K or 6DT-E30KSS 30° elbow kit, with 6DT-ES elbow strap (a support is required when the offset has two or more chimney sections)\u003c\/li\u003e\n\u003cli\u003eDuraTech 6\" ceiling and attic parts: 6DT-FS firestop or 6DT-FRS firestop radiation shield; 6DT-IS attic insulation shield\u003c\/li\u003e\n\u003cli\u003eRoof flashing: choose one roof flashing to suit your roof pitch: 6DT-FF flat roof flashing; 6DT-F6 adjustable roof flashing (0\/12 to 6\/12); 6DT-F6L large-base adjustable roof flashing (0\/12 to 6\/12); 6DT-F12 adjustable roof flashing (7\/12 to 12\/12); 6DT-F12L large-base adjustable roof flashing (7\/12 to 12\/12); 6DT-F18 adjustable roof flashing (13\/12 to 18\/12); 6DT-F24 adjustable roof flashing (19\/12 to 24\/12); 6DT-F6DSA or 6DT-F12DSA DSA roof flashing; or 6DT-CTF chase top flashing where the chimney ends in a chase\u003c\/li\u003e\n\u003cli\u003eRain cap: 6DT-VC chimney cap\u003c\/li\u003e\n\u003cli\u003eRoof brace when the chimney rises more than 5 ft above the roof: 6DT-ARS adjustable roof support or 6DT-XRS extended roof bracket\u003c\/li\u003e\n\u003cli\u003eNon-combustible floor protection, 16\" in front and 8\" past each side of the door opening (R 1.00 at floor level or raised 4\" or less)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAC01275 fire screen door\u003c\/li\u003e\n\u003cli\u003eAC01223 heat shield for a combustible shelf (lowers the shelf to 50\"-56\")\u003c\/li\u003e\n\u003cli\u003eAC01375 traditional gravity kit or AC01389 modern gravity kit with adjustable pipes (two outlets; 8\" rigid 26 ga ducting not included)\u003c\/li\u003e\n\u003cli\u003eAC01374 forced air kit, with AC01350 6\" x 25' insulated flex pipe\u003c\/li\u003e\n\u003cli\u003eAC01347 4\" fresh air intake register with airtight damper\u003c\/li\u003e\n\u003cli\u003eAC02091 4\" x 10' or AC01359 4\" x 25' insulated flex pipe for fresh air\u003c\/li\u003e\n\u003cli\u003eAC09200 fireplace carrying handles\u003c\/li\u003e\n\u003cli\u003eAC02760 tempered glass hearth pad, 18\" x 50\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation, Clearances and Safety\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType of chimney\u003c\/th\u003e\n\u003ctd\u003eCAN\/ULC S629, UL 103 HT (2100 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChimney diameter\u003c\/th\u003e\n\u003ctd\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum chimney height\u003c\/th\u003e\n\u003ctd\u003e15 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproved for a mobile home installation\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUSA safety standard\u003c\/th\u003e\n\u003ctd\u003eUL 127\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUSA emissions standard\u003c\/th\u003e\n\u003ctd\u003eEPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTesting\u003c\/th\u003e\n\u003ctd\u003eBy an accredited laboratory (CAN\/USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eChimney: a 6\" chimney listed to UL 103 HT from Osburn's approved brands (Olympia \/ SBI Ventis, Nexvent, Champion; Rockford Rock-Vent; Selkirk CF Sentinel, Super Pro 2100, Super Vent 2100; Security Chimney S-2100; DuraVent Dura Tech, Dura Tech Premium, Dura Plus; Metal Fab Temp Guard; American Metal HS \/ HSS). It must be at least 15 ft from the base of the fireplace to the cap (17 ft with four elbows), run at least 18\" straight up before the first offset, keep 2\" to combustibles, end at least 3 ft above the roof and 2 ft higher than anything within 10 ft, and have a rain cap. A roof brace is needed when it rises more than 5 ft above the roof. A wall thimble is required where an offset passes through a wall. The chimney may not serve any other appliance. The fireplace and chimney must be enclosed up to the attic, and the fireplace is not approved for mobile or manufactured homes. The certification label on the appliance overrides any other published figure.\u003c\/p\u003e\n\u003ch3\u003eFuel, Operation and Care\u003c\/h3\u003e\n\u003cp\u003eBurn only dry cordwood (16\" recommended). Keep the door closed during normal operation, let ashes cool completely before disposal, and have the chimney and appliance inspected and cleaned regularly.\u003c\/p\u003e\n\u003ch3\u003eManufacturer Warranty Information\u003c\/h3\u003e\u003cp\u003eOsburn limited lifetime warranty (parts \/ labour):\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCombustion chamber (welds only) and cast iron door frame: lifetime \/ 5 years\u003c\/li\u003e\n\u003cli\u003eCeramic glass, plating (manufacturing defect) and convector air-mate: lifetime\u003c\/li\u003e\n\u003cli\u003eSurrounds, heat shields, trims, C-Cast baffle, secondary air tubes and stainless combustion chamber parts: 7 years\u003c\/li\u003e\n\u003cli\u003eHandle assembly, glass retainers and air control mechanism: 5 years \/ 3 years\u003c\/li\u003e\n\u003cli\u003eRemovable carbon steel combustion chamber parts: 5 years\u003c\/li\u003e\n\u003cli\u003eBlower, heat sensors, switches, rheostat, wiring and electronics: 2 years \/ 1 year\u003c\/li\u003e\n\u003cli\u003ePaint (peeling), gaskets, insulation, refractory bricks and other options: 1 year\u003c\/li\u003e\n\u003cli\u003eParts replaced under warranty: 90 days\u003c\/li\u003e\n\u003cli\u003eInstallation must be done by an authorized qualified technician; the warranty is void if anything other than cordwood is burned\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eManufacturer Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7612\/46104a_2024-12-18.pdf\"\u003eStratford II wood fireplace install \u0026amp; owner's manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5240\/ob04007-osburn-stratford-ii.pdf\"\u003eStratford II dimensions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5238\/stratford-ii_en_quick-install-reference-guide.pdf\"\u003eStratford II wood fireplace quick install reference guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7334\/46337af_2024-01-15.pdf\"\u003eInstallation instructions for faceplates OA10255 and OA10256\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5241\/ob04007-fa%C3%A7ade-contemporaine.dwg\"\u003e2D diagram (DWG)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5244\/ob04007-fa%C3%A7ade-traditionnelle.dwg\"\u003e2D diagram (DWG)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5242\/ob04007-fa%C3%A7ade-contemporaine.dxf\"\u003e2D diagram (DXF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5245\/ob04007-fa%C3%A7ade-traditionnelle.dxf\"\u003e2D diagram (DXF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eInformation is summarized from Osburn's published specifications and manuals. Always follow the complete installation manual; this page does not replace its safety diagrams or site-specific installation requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — OB04007\u003c\/h3\u003e\n\u003ch4\u003eWhat size framing does the OB04007 need?\u003c\/h4\u003e\u003cp\u003eFrame an opening 37-3\/4\" wide, 41-5\/8\" high to the first header and 24-7\/8\" deep, with 80\" total height and nothing in the space above the fireplace up to 80\" from its base. Allow 60-3\/4\" of width with the fresh air intake or 72-3\/4\" with the forced air kit. Clearance to the enclosure is 0\" at the back, sides and floor.\u003c\/p\u003e\n\u003ch4\u003eHow high must the mantel or shelf be?\u003c\/h4\u003e\u003cp\u003eA 6\" deep combustible shelf can sit 58\" above the base of the fireplace; allow 60\" for 8\", 62\" for 10\" and 64\" for 12\". The optional AC01223 heat shield lowers that to 50\" to 56\". A side mantel can be no deeper than 3\" and at least 8\" from the door opening, and a side wall must be 13\" away.\u003c\/p\u003e\n\u003ch4\u003eWhat chimney does it use?\u003c\/h4\u003e\u003cp\u003eA 6\" chimney listed to UL 103 HT from Osburn's approved brands, including DuraVent DuraTech. It must be at least 15 ft from the base to the cap (17 ft with four elbows) and end at least 3 ft above the roof and 2 ft higher than anything within 10 ft. We carry DuraTech 6\" parts (6DT-*).\u003c\/p\u003e\n\u003ch4\u003eHow much area does it heat?\u003c\/h4\u003e\u003cp\u003eOsburn rates it for 750 to 2,200 sq. ft., with an output of 12,700 to 60,700 BTU\/h, up to 80,000 BTU\/h maximum and up to 8 hours of burn time. The included 176 CFM blower moves the heat into the room.\u003c\/p\u003e\n\u003ch4\u003eWhich parts do I have to choose?\u003c\/h4\u003e\u003cp\u003eOne faceplate, OA10255 traditional or OA10256 modern, and one door overlay, OA10610 black or OA10612 brushed nickel. The blower is already included.\u003c\/p\u003e\n\u003ch4\u003eWhat's the warranty?\u003c\/h4\u003e\u003cp\u003eOsburn gives a limited lifetime warranty: lifetime on the combustion chamber welds and cast iron door frame (5 years labour) and on the ceramic glass, 7 years on surrounds, baffle and air tubes, and 2 years parts \/ 1 year labour on the blower and electrical parts. An authorized qualified technician must install it.\u003c\/p\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":50680694177954,"sku":"OB04007","price":4499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Osburn-Stratford-II-Zero-Clearance-Wood-Fireplace-Insert-OB04007_434__97049.1785141992.1280.1280.jpg?v=1793125065"},{"product_id":"osburn-2000-wood-insert-ob02016","title":"Osburn 2000 Wood Insert OB02016","description":"\u003ch2\u003eOsburn 2000 Wood Insert\u003c\/h2\u003e\n\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Osburn 2000 OB02016 is a large wood insert that turns an existing masonry fireplace into a primary heat source for homes of 500 to 2,100 sq. ft. It needs a masonry opening of at least 23-3\/8\" high, 28-7\/8\" wide and 15-3\/4\" deep. It is made for masonry fireplaces only: it is not for factory-built fireplaces, mobile homes or alcoves.\u003c\/p\u003e\u003cp\u003eA cast-iron door with an arched ceramic glass gives a 17-1\/8\" wide view of the fire, and an air-wash system helps keep the glass clear. You finish the front with a black (OA10237) or brushed nickel (OA10238) door overlay and a faceplate, regular 29\" x 44\", large 32\" x 50\" or cuttable 32\" x 50\", with matching trims.\u003c\/p\u003e\u003cp\u003eThe non-catalytic, refractory-lined firebox (2.4 cu. ft.) takes logs up to 20\" and burns up to 8 hours, with an output of 14,200 to 44,500 BTU\/h and up to 75,000 BTU\/h. It meets the EPA 2020 standard at 2.3 g\/h with 72% (HHV) average efficiency, and a 144 CFM blower is included to move the heat into the room.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-catalytic combustion technology.\u003c\/li\u003e\n\u003cli\u003eHigh-efficiency certified appliance: Yes, EPA 2020 approved.\u003c\/li\u003e\n\u003cli\u003eFirebox lined with refractory bricks for better heat distribution.\u003c\/li\u003e\n\u003cli\u003eStainless-steel secondary-air system for cleaner secondary combustion.\u003c\/li\u003e\n\u003cli\u003eGlass air-wash system to help keep the view of the fire clear.\u003c\/li\u003e\n\u003cli\u003eBlower included.\u003c\/li\u003e\n\u003cli\u003eBaffle: C-Cast or equivalent.\u003c\/li\u003e\n\u003cli\u003e2.4 cu. ft. firebox (1.95 cu. ft. EPA loading volume); logs up to 20\" (16\" recommended), loaded side to side\u003c\/li\u003e\n\u003cli\u003eUp to 8 hours of burn time; 14,200 to 44,500 BTU\/h output, 75,000 BTU\/h maximum\u003c\/li\u003e\n\u003cli\u003e72% (HHV) \/ 77% (LHV) average efficiency, 79% optimum; 2.3 g\/h particulate emissions\u003c\/li\u003e\n\u003cli\u003e144 CFM blower (115 V, 60 Hz, 1.1 A) included, with thermodisc and 96\" power cord\u003c\/li\u003e\n\u003cli\u003eSingle cast-iron door with arched ceramic glass, 17-1\/8\" W x 10-1\/4\" H\u003c\/li\u003e\n\u003cli\u003eFaceplates cover a masonry fireplace face up to 32\" high and 50\" wide\u003c\/li\u003e\n\u003cli\u003e3\/16\" steel body, 5\/16\" steel top, adjustable threaded legs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHeating Performance and Efficiency\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended heating area\u003c\/th\u003e\n\u003ctd\u003e500 - 2,100 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum burn time\u003c\/th\u003e\n\u003ctd\u003e8 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall firebox volume\u003c\/th\u003e\n\u003ctd\u003e2.4 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAverage particulate emissions\u003c\/th\u003e\n\u003ctd\u003e2.3 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eValues are as measured per the test method, except the recommended heating area, firebox volume and maximum burn time, which are manufacturer estimates. Location in the home, chimney draft, heat loss, climate and fuel all affect actual performance.\u003c\/p\u003e\n\u003ch3\u003eDimensions and Firebox Details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e28-5\/8\" W x 23-1\/8\" H x 26-3\/8\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eMinimum fireplace opening (masonry): 23-3\/8\" H x 28-7\/8\" W x 15-3\/4\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003eGlass 17-1\/8\" W x 10-1\/4\" H; door opening 17-1\/2\" W x 9\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eSide wall 16\"; combustible side surround 9\"; combustible top surround 27\"; combustible mantel shelf 27\" above the insert (shelf no deeper than 12\"); with the AC01317 heat shield the top surround and mantel clearances drop to 21\"; ceiling 84\" from the floor the insert stands on. Floor protection (USA): non-combustible, 16\" in front of the door and 8\" to the sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum log length\u003c\/th\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue outlet diameter\u003c\/th\u003e\n\u003ctd\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e434 lb (197 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOsburn 2000 insert with SE24285 cast-iron door and SE65025 arched ceramic glass\u003c\/li\u003e\n\u003cli\u003eSE74172 blower assembly: 44089 144 CFM blower (115 V, 60 Hz, 1.1 A), 44028 thermodisc and 60013 96\" power cord\u003c\/li\u003e\n\u003cli\u003e21389 C-Cast baffle and PL65514 secondary air tubes\u003c\/li\u003e\n\u003cli\u003eRefractory brick lining\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne door overlay (not included in the base price): OA10237 black or OA10238 brushed nickel\u003c\/li\u003e\n\u003cli\u003eOne faceplate (not included in the base price): AC03410 regular 29\" x 44\" with OA10122 black or OA10123 brushed nickel trims; AC03411 large 32\" x 50\" with OA10128 black or OA10129 brushed nickel trims; or AC01357 32\" x 50\" cuttable faceplate (18 ga), which uses no trim kit\u003c\/li\u003e\n\u003cli\u003eA 6\" chimney liner listed to UL 1777 from the insert to the top of the masonry chimney, at least 12 ft tall, ending at least 3 ft above the roof\u003c\/li\u003e\n\u003cli\u003eNon-combustible floor protection, 16\" in front of the door and 8\" to the sides (USA)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAC01315 rigid fire screen\u003c\/li\u003e\n\u003cli\u003eAC01317 7-3\/16\" x 26\" heat shield for surround\/shelf (cuts the top surround and mantel clearance to 21\")\u003c\/li\u003e\n\u003cli\u003eAC02006 liner hook-up system\u003c\/li\u003e\n\u003cli\u003eAC01214 offset liner adapter\u003c\/li\u003e\n\u003cli\u003eAC01298 5\" fresh air intake kit\u003c\/li\u003e\n\u003cli\u003eAC01349 5\" fresh air intake register with airtight damper\u003c\/li\u003e\n\u003cli\u003eAC02090 5\" x 4' insulated flex pipe for fresh air intake\u003c\/li\u003e\n\u003cli\u003eAC02760 tempered glass hearth pad 18\" x 50\" (10 mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation, Clearances and Safety\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType of chimney\u003c\/th\u003e\n\u003ctd\u003eLiner - ULC-S635, CAN\/ULC-S640, UL1777\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChimney diameter\u003c\/th\u003e\n\u003ctd\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproved for a mobile home installation\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum chimney height\u003c\/th\u003e\n\u003ctd\u003e12 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproved for an alcove installation\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproved for a factory-built (zero-clearance) fireplace\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUSA safety standard\u003c\/th\u003e\n\u003ctd\u003eUL 1482, UL 737\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTesting\u003c\/th\u003e\n\u003ctd\u003eBy an accredited laboratory (CAN\/USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eVenting: a 6\" chimney liner listed to UL 1777 runs from the insert to the top of the masonry chimney. The chimney must be at least 12 ft tall and end at least 3 ft above the roof. Installing the Osburn 2000 insert in a factory-built fireplace is forbidden, and it is not approved for mobile homes or alcoves. The certification label on the appliance overrides any other published figure.\u003c\/p\u003e\n\u003ch3\u003eFuel, Operation and Care\u003c\/h3\u003e\n\u003cp\u003eBurn only dry cordwood (16\" recommended). Keep the door closed during normal operation, let ashes cool completely before disposal, and have the chimney and appliance inspected and cleaned regularly.\u003c\/p\u003e\n\u003ch3\u003eManufacturer Warranty Information\u003c\/h3\u003e\u003cp\u003eOsburn limited lifetime warranty (parts \/ labour):\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCombustion chamber (welds only) and cast iron door frame: lifetime \/ 5 years\u003c\/li\u003e\n\u003cli\u003eCeramic glass, plating (manufacturing defect) and convector air-mate: lifetime\u003c\/li\u003e\n\u003cli\u003eSurrounds, heat shields, trims, C-Cast baffle, secondary air tubes and removable stainless combustion chamber parts: 7 years\u003c\/li\u003e\n\u003cli\u003eHandle assembly, glass retainers and air control mechanism: 5 years \/ 3 years\u003c\/li\u003e\n\u003cli\u003eRemovable carbon steel combustion chamber parts: 5 years\u003c\/li\u003e\n\u003cli\u003eBlower, heat sensors, switches, rheostat, wiring and electronics: 2 years \/ 1 year\u003c\/li\u003e\n\u003cli\u003ePaint (peeling), gaskets, insulation and other options: 1 year\u003c\/li\u003e\n\u003cli\u003eParts replaced under warranty: 90 days\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eManufacturer Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7891\/45927a_2026-02-13.pdf\"\u003eOsburn 2000 wood insert install \u0026amp; owner's manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/4710\/45939a_14-11-2018.pdf\"\u003eFaceplates Installation Instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eInformation is summarized from Osburn's published specifications and manuals. Always follow the complete installation manual; this page does not replace its safety diagrams or site-specific installation requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — OB02016\u003c\/h3\u003e\n\u003ch4\u003eWhat size fireplace opening does the OB02016 need?\u003c\/h4\u003e\u003cp\u003eA masonry opening at least 23-3\/8\" high, 28-7\/8\" wide and 15-3\/4\" deep. Overall, the insert is 28-5\/8\" wide, 23-1\/8\" high and 26-3\/8\" deep.\u003c\/p\u003e\n\u003ch4\u003eCan it go in a factory-built (zero-clearance) fireplace?\u003c\/h4\u003e\u003cp\u003eNo. Osburn forbids installing it in a factory-built fireplace, and it is not approved for mobile homes or alcoves. It is made for masonry fireplaces.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it need?\u003c\/h4\u003e\u003cp\u003eA 6\" chimney liner listed to UL 1777 from the insert to the top of the masonry chimney. The chimney must be at least 12 ft tall and end at least 3 ft above the roof.\u003c\/p\u003e\n\u003ch4\u003eHow close can a wood mantel or trim be?\u003c\/h4\u003e\u003cp\u003eA combustible side surround needs 9\" and a top surround 27\". A mantel shelf up to 12\" deep needs 27\" above the insert. With the AC01317 heat shield, the top surround and mantel clearances drop to 21\". Keep 16\" to a side wall and 84\" to the ceiling from the floor the insert stands on.\u003c\/p\u003e\n\u003ch4\u003eIs the blower included, and which parts do I have to choose?\u003c\/h4\u003e\u003cp\u003eYes, the 144 CFM blower (115 V) with thermodisc and a 96\" power cord comes with the insert. You choose one door overlay (OA10237 black or OA10238 brushed nickel) and one faceplate: regular 29\" x 44\" or large 32\" x 50\" with matching trims, or the 32\" x 50\" cuttable faceplate.\u003c\/p\u003e\n\u003ch4\u003eWhat's the warranty?\u003c\/h4\u003e\u003cp\u003eOsburn gives a limited lifetime warranty: lifetime on the combustion chamber welds and cast iron door frame (5 years labour) and on the ceramic glass, 7 years on surrounds, trims, baffle and air tubes, and 2 years parts \/ 1 year labour on the blower and electrical parts.\u003c\/p\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":50680699322530,"sku":"OB02016","price":3129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Osburn-2000-Wood-Insert-OB02016_473__26325.1785142155.1280.1280.jpg?v=1792461507"},{"product_id":"osburn-3500-wood-insert-ob03510","title":"Osburn 3500 Wood Insert OB03510","description":"\u003ch2\u003eOsburn 3500 Wood Insert\u003c\/h2\u003e\n\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Osburn 3500 OB03510 is a large wood insert that turns an existing masonry fireplace into a primary heat source for big, open homes of 1,000 to 2,700 sq. ft. It fits a masonry opening of at least 31\" wide, 26-1\/4\" high and 18-3\/8\" deep. It is not approved for factory-built fireplaces or mobile homes.\u003c\/p\u003e\u003cp\u003eA single cast iron framed door with ceramic glass gives a 19\" x 11-3\/4\" view of the fire across a 3.5 cu. ft. firebox lined with refractory brick, which takes logs up to 22\". You finish the front with a door overlay and a medium (32\" x 44\") or large (32\" x 50\") faceplate with matching trims.\u003c\/p\u003e\u003cp\u003eThe non-catalytic firebox burns up to 10 hours, with an output of 17,200 to 57,800 BTU\/h and up to 110,000 BTU\/h. It meets the EPA 2020 standard at 1.6 g\/h with 71% (HHV) average efficiency. A blower of up to 144 CFM is included, and the insert vents through a continuous 6\" stainless steel liner.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-catalytic combustion technology.\u003c\/li\u003e\n\u003cli\u003eHigh-efficiency certified appliance: Yes, EPA 2020 approved.\u003c\/li\u003e\n\u003cli\u003eFirebox lined with refractory bricks for better heat distribution.\u003c\/li\u003e\n\u003cli\u003eStainless-steel secondary-air system for cleaner secondary combustion.\u003c\/li\u003e\n\u003cli\u003eGlass air-wash system to help keep the view of the fire clear.\u003c\/li\u003e\n\u003cli\u003eDoor: Single, glass with cast iron frame; ceramic glass.\u003c\/li\u003e\n\u003cli\u003eBlower included (144 CFM).\u003c\/li\u003e\n\u003cli\u003eBaffle: C-Cast or equivalent.\u003c\/li\u003e\n\u003cli\u003e3.5 cu. ft. firebox (2.88 cu. ft. EPA loading volume); 16\" logs recommended, 22\" maximum, loaded east-west\u003c\/li\u003e\n\u003cli\u003eUp to 10 hours of burn time; 17,200 to 57,800 BTU\/h output, 110,000 BTU\/h maximum\u003c\/li\u003e\n\u003cli\u003e71% (HHV) \/ 76% (LHV) average efficiency, 77% optimum; 1.6 g\/h particulate emissions\u003c\/li\u003e\n\u003cli\u003e44089 double cage blower, up to 144 CFM (115 V, 60 Hz, 1.1 A), with rheostat speed control and heat sensor\u003c\/li\u003e\n\u003cli\u003e19\" x 11-3\/4\" fire view through a single cast iron framed door\u003c\/li\u003e\n\u003cli\u003e3\/16\" steel body, 5\/16\" steel top\u003c\/li\u003e\n\u003cli\u003eFor masonry fireplaces only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHeating Performance and Efficiency\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended heating area\u003c\/th\u003e\n\u003ctd\u003e1,000 - 2,700 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum heat output\u003c\/th\u003e\n\u003ctd\u003e110,000 BTU\/h (32.2 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall heat output rate\u003c\/th\u003e\n\u003ctd\u003e17,200 BTU\/h (5.0 kW) to 57,800 BTU\/h (16.9 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum burn time\u003c\/th\u003e\n\u003ctd\u003e10 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall firebox volume\u003c\/th\u003e\n\u003ctd\u003e3.5 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEPA loading volume\u003c\/th\u003e\n\u003ctd\u003e2.88 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAverage overall efficiency\u003c\/th\u003e\n\u003ctd\u003e71 % (HHV) \/ 76 % (LHV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptimum overall efficiency\u003c\/th\u003e\n\u003ctd\u003e77 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptimum heat transfer efficiency\u003c\/th\u003e\n\u003ctd\u003e75 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAverage particulate emissions\u003c\/th\u003e\n\u003ctd\u003e1.6 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAverage CO\u003c\/th\u003e\n\u003ctd\u003e73 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eValues are as measured per the test method, except the recommended heating area, firebox volume, maximum burn time and maximum heat output, which are manufacturer estimates. Location in the home, chimney draft, heat loss, climate and fuel all affect actual performance.\u003c\/p\u003e\n\u003ch3\u003eDimensions and Firebox Details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e30-3\/8\" W x 24-7\/8\" H x 29\" D (insert body, without faceplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eMinimum fireplace opening (masonry only): 26-1\/4\" H x 31\" W x 18-3\/8\" D. Add at least 4\" to the width if a fresh air intake is used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e19\" W x 11-3\/4\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eAdjacent side wall 19\" from the insert; combustible side surround 9\" (maximum 5\" thick); combustible top surround 27\" above the insert; combustible mantel shelf 27\" above the insert (maximum 12\" deep); ceiling 84\" measured from the platform the insert is installed on. Floor protection (USA): non-combustible, 16\" in front and 8\" to each side; a masonry hearth extension that is long enough counts toward it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox dimensions\u003c\/th\u003e\n\u003ctd\u003e12 7\/8\" H × 22 7\/8\" W × 20 1\/8\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDoor opening\u003c\/th\u003e\n\u003ctd\u003e9 7\/8\" H × 19\" W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum log length\u003c\/th\u003e\n\u003ctd\u003e22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLog positioning\u003c\/th\u003e\n\u003ctd\u003eEast-west (loaded across the width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue outlet diameter\u003c\/th\u003e\n\u003ctd\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSteel thickness, body \/ top\u003c\/th\u003e\n\u003ctd\u003e3\/16\" \/ 5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e540 lb (245 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3500 insert with single cast iron framed door and ceramic glass\u003c\/li\u003e\n\u003cli\u003eSE18286 blower assembly: 44089 double cage blower, up to 144 CFM, with 44080 rheostat, 44028 thermodisc and 60013 power cord (96\")\u003c\/li\u003e\n\u003cli\u003e21565 C-Cast baffle with 21564 insulation top, and PL70864 stainless secondary air tubes (4)\u003c\/li\u003e\n\u003cli\u003eRefractory brick lining\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne door overlay (not included in the base price): OA10163 black or OA10164 brushed nickel\u003c\/li\u003e\n\u003cli\u003eOne faceplate (not included in the base price): OA10032 medium, 32\" x 44\", or OA10033 large, 32\" x 50\"\u003c\/li\u003e\n\u003cli\u003eOne faceplate trim kit sized to the faceplate (not included in the base price): OA10125 black for the 32\" x 44\" faceplate or OA10128 black for the 32\" x 50\" faceplate; OA10126 and OA10129 are also offered\u003c\/li\u003e\n\u003cli\u003eA continuous 6\" stainless steel liner listed to UL 1777 (ULC S635 \/ CAN\/ULC-S640) from the insert to the top of the chimney; the chimney must be at least 12 ft tall, end at least 3 ft above the roof and 2 ft higher than anything within 10 ft\u003c\/li\u003e\n\u003cli\u003eAn existing masonry fireplace with an opening of at least 31\" W x 26-1\/4\" H x 18-3\/8\" D\u003c\/li\u003e\n\u003cli\u003eNon-combustible floor protection, 16\" in front and 8\" to each side (USA)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAC01298 5\" fresh air intake kit\u003c\/li\u003e\n\u003cli\u003eAC02090 5\" x 4' insulated flex pipe for fresh air intake\u003c\/li\u003e\n\u003cli\u003eAC02006 liner hook-up system\u003c\/li\u003e\n\u003cli\u003eAC01214 offset liner adapter\u003c\/li\u003e\n\u003cli\u003eAC01281 rigid firescreen\u003c\/li\u003e\n\u003cli\u003eAC02760 tempered glass hearth pad, 10 mm, 18\" x 50\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation, Clearances and Safety\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType of chimney\u003c\/th\u003e\n\u003ctd\u003eLiner - ULC-S635, CAN\/ULC-S640, UL1777\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChimney diameter\u003c\/th\u003e\n\u003ctd\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum chimney height\u003c\/th\u003e\n\u003ctd\u003e12 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproved for a mobile home installation\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUSA safety standard\u003c\/th\u003e\n\u003ctd\u003eUL 1482, UL 737\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUSA emissions standard\u003c\/th\u003e\n\u003ctd\u003eEPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTesting\u003c\/th\u003e\n\u003ctd\u003eBy an accredited laboratory (CAN\/USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eInstall only in an existing masonry fireplace; Osburn forbids installing this insert in a factory-built fireplace, and it is not approved for mobile homes. Venting is a continuous 6\" stainless steel liner listed to UL 1777 (Class 3) running from the insert to the top of the chimney. The chimney must be at least 12 ft tall, end at least 3 ft above the roof and 2 ft higher than anything within 10 ft. A mesh chimney cap must be cleanable, or the mesh removed. The certification label on the appliance overrides any other published figure.\u003c\/p\u003e\n\u003ch3\u003eFuel, Operation and Care\u003c\/h3\u003e\n\u003cp\u003eBurn only dry cordwood (16\" recommended). Keep the door closed during normal operation, let ashes cool completely before disposal, and have the chimney and appliance inspected and cleaned regularly.\u003c\/p\u003e\n\u003ch3\u003eManufacturer Warranty Information\u003c\/h3\u003e\u003cp\u003eOsburn limited lifetime warranty (parts \/ labour):\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCombustion chamber (welds only) and cast iron door frame: lifetime \/ 5 years\u003c\/li\u003e\n\u003cli\u003eCeramic glass, plating (manufacturing defect) and convector air-mate: lifetime\u003c\/li\u003e\n\u003cli\u003eSurrounds, heat shields, trims, C-Cast baffle, secondary air tubes and stainless combustion chamber parts: 7 years\u003c\/li\u003e\n\u003cli\u003eHandle assembly, glass retainers and air control mechanism: 5 years \/ 3 years\u003c\/li\u003e\n\u003cli\u003eRemovable carbon steel combustion chamber parts: 5 years\u003c\/li\u003e\n\u003cli\u003eBlower, heat sensors, switches, rheostat, wiring and electronics: 2 years \/ 1 year\u003c\/li\u003e\n\u003cli\u003ePaint (peeling), gaskets, insulation and other options: 1 year\u003c\/li\u003e\n\u003cli\u003eParts replaced under warranty: 90 days\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eManufacturer Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7017\/46180a_2023-08-25.pdf\"\u003eOsburn 3500-I wood insert install \u0026amp; owner's manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5672\/ob03510-osburn-35-i.pdf\"\u003eOsburn 3500-I dimensions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5968\/ob03510.dwg\"\u003e2D diagram (DWG)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5969\/ob03510.dxf\"\u003e2D diagram (DXF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eInformation is summarized from Osburn's published specifications and manuals. Always follow the complete installation manual; this page does not replace its safety diagrams or site-specific installation requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions — OB03510\u003c\/h3\u003e\n\u003ch4\u003eWhat size fireplace opening does the OB03510 need?\u003c\/h4\u003e\u003cp\u003eA masonry fireplace opening of at least 31\" wide, 26-1\/4\" high and 18-3\/8\" deep. If you add a fresh air intake, allow at least 4\" more width. The insert body measures 30-3\/8\" W x 24-7\/8\" H x 29\" D.\u003c\/p\u003e\n\u003ch4\u003eCan it go in a factory-built (zero-clearance) fireplace?\u003c\/h4\u003e\u003cp\u003eNo. Osburn forbids installing the 3500 insert in a factory-built fireplace, and it is not approved for mobile homes. It is for existing masonry fireplaces only.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it need?\u003c\/h4\u003e\u003cp\u003eA continuous 6\" stainless steel liner listed to UL 1777 from the insert to the top of the chimney. The chimney must be at least 12 ft tall, end 3 ft above the roof and 2 ft higher than anything within 10 ft.\u003c\/p\u003e\n\u003ch4\u003eHow close can a wood mantel or trim be?\u003c\/h4\u003e\u003cp\u003eA combustible mantel shelf must be 27\" above the insert and no more than 12\" deep. A combustible top surround needs 27\", a side surround 9\" (no more than 5\" thick), and an adjacent side wall 19\".\u003c\/p\u003e\n\u003ch4\u003eHow much area does it heat?\u003c\/h4\u003e\u003cp\u003eOsburn rates it for 1,000 to 2,700 sq. ft., with an output of 17,200 to 57,800 BTU\/h, up to 110,000 BTU\/h maximum and up to 10 hours of burn time. It takes logs up to 22\".\u003c\/p\u003e\n\u003ch4\u003eWhat's the warranty?\u003c\/h4\u003e\u003cp\u003eOsburn gives a limited lifetime warranty: lifetime on the combustion chamber welds and cast iron door frame (5 years labour) and on the ceramic glass, 7 years on surrounds, trims, baffle and air tubes, and 2 years parts \/ 1 year labour on the blower and electrical parts.\u003c\/p\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":50680724848802,"sku":"OB03510","price":3819.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Osburn-3500-Wood-Insert-OB03510_506__57776.1785142275.1280.1280.jpg?v=1793125400"},{"product_id":"buck-stove-townsend-ii-vent-free-gas-stove-nv-s-townsend","title":"Buck Stove Townsend II Vent Free Gas Stove NV S-TOWNSEND","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Buck Stove Townsend II is a steel vent-free gas stove with the proportions of a traditional wood stove, finished in black, gray or vintage copper. It frames a five-piece DX18 ceramic log fire with an ember strip for a cozy, cabin-style look.\u003c\/p\u003e\u003cp\u003eIt is rated 22,400 to 32,000 BTU\/hr and sits right on the hearth or floor panel with no chimney, so it is an easy way to add heat and atmosphere to a living room, sunroom or addition.\u003c\/p\u003e\u003cp\u003eA millivolt valve with piezo ignition and an ODS safety pilot runs without electricity, and the stove accepts Buck's wall thermostat or thermostatic remotes. The MA CVF714 blower is an option for faster heat circulation.\u003c\/p\u003e\u003cp\u003eNatural gas or propane models in three colors. Approved for aftermarket manufactured homes. Made by Buck Stove.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e22,400-32,000 BTU\/hr\u003c\/strong\u003e (manual p.11).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDX18 ceramic log set\u003c\/strong\u003e with ember strip included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteel body\u003c\/strong\u003e in Black, Gray or Vintage Copper.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMillivolt valve\u003c\/strong\u003e with Hi\/Lo control; works without electricity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote and wall-thermostat compatible\u003c\/strong\u003e (FDC-504, PE 400142).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePiezo ignition\u003c\/strong\u003e and \u003cstrong\u003eODS pilot\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional blower\u003c\/strong\u003e MA CVF714 (motor\/blower not included).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNatural gas or propane\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAftermarket manufactured-home approved\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed to ANSI Z21.11.2-2016\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eNV S-TOWNSEND BLK \/ GY \/ VC, -NG or -LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e22,400-32,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e26-1\/2\" W x 26-1\/4\" H x 16-1\/2\" D (Buck)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eValve\u003c\/th\u003e\n\u003ctd\u003eSIT millivolt, Hi\/Lo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas pressures\u003c\/th\u003e\n\u003ctd\u003eNG inlet 4.5-10.5\" W.C., manifold 3.5\"; LP inlet 10.5-13.0\" W.C., manifold 10.0\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLogs\u003c\/th\u003e\n\u003ctd\u003eDX18 (PO18DXLOG), 5 logs + ember strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBlower\u003c\/th\u003e\n\u003ctd\u003eOptional MA CVF714\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearances\u003c\/th\u003e\n\u003ctd\u003e4\" side and back walls; 48\" stove top to ceiling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHigh altitude\u003c\/th\u003e\n\u003ctd\u003eAbove 4,500 ft may cause pilot outage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eANSI Z21.11.2-2016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTownsend II steel vent-free stove\u003c\/li\u003e\n\u003cli\u003eDX18 ceramic log set with ember strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired (sold separately)\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGas supply line of the fuel ordered, with an accessible shutoff valve and sediment trap\u003c\/li\u003e\n\u003cli\u003ePropane: external regulator limiting tank pressure to 13\" W.C.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMA CVF714 blower motor (Townsend II only)\u003c\/li\u003e\n\u003cli\u003ePO FDC504-S SkyTech thermostatic remote, dark gray (millivolt)\u003c\/li\u003e\n\u003cli\u003ePO FDC504-A Acumen thermostatic remote, black (millivolt)\u003c\/li\u003e\n\u003cli\u003ePE 400142 white wall thermostat (millivolt)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMaterials and components: two years from first purchase, original purchaser (manual p.28).\u003c\/li\u003e\n\u003cli\u003eElectrical motor, wiring, switches and optional accessories: one year.\u003c\/li\u003e\n\u003cli\u003eOriginal factory parts and a qualified installer required; liability limited to purchase price.\u003c\/li\u003e\n\u003cli\u003eMail the registration within 30 days of installation.\u003c\/li\u003e\n\u003cli\u003eSource: Buck Townsend II manual, May 2019, page 28.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/buckstove.com\/wp-content\/uploads\/2024\/10\/Buck-Stove-Townsend-II-Hepplewhite-Steel-Manual-May-2019.pdf\"\u003eTownsend II \/ Hepplewhite steel stove manual (May 2019)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation and safety\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e Improper installation, adjustment, alteration, service or maintenance can cause fire, explosion, property damage, injury or carbon-monoxide poisoning. This vent-free gas appliance must be installed and serviced by a qualified professional following the manufacturer's manual and your local codes. If you ever smell gas, do not light anything or touch electrical switches; leave and call your gas supplier.\u003c\/p\u003e\u003ch4\u003eSafety information (manual pp.1-3)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNot for bedrooms, bathrooms, RVs, or drafty, high-traffic areas; supplemental heat except in power outages.\u003c\/li\u003e\n\u003cli\u003eDo not add logs or decorations, cook on it, or run it with a broken log.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eRoom size and fresh air (manual pp.4-6)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eThe room must be an unconfined space: at least 50 cubic feet per 1,000 BTU\/hr of all gas appliances in the space (some areas require 70).\u003c\/li\u003e\n\u003cli\u003eExample from the manual: a 20 x 16 x 8 ft room (2,560 cu. ft.) supports up to 51,200 BTU\/hr.\u003c\/li\u003e\n\u003cli\u003eIn tighter spaces, add two permanent openings to an adjoining room or outdoors (one within 12\" of the ceiling, one within 12\" of the floor, each at least 1 sq. in. per 1,000 BTU\/hr and 100 sq. in. minimum).\u003c\/li\u003e\n\u003cli\u003eVent-free heaters add moisture to the room; poor ventilation can cause mildew.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eClearances and location (manual p.9)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e4\" from the stove top's outermost point to side and back walls (including corners); 48\" to the ceiling.\u003c\/li\u003e\n\u003cli\u003eKeep furniture and curtains 48\" from the front, top and sides; set on a metal or wood panel, not carpet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas connection (manual pp.9-11)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e3\/8\" NPT inlet, 1\/2\" or larger supply; CSA\/AGA-certified shutoff valve.\u003c\/li\u003e\n\u003cli\u003eNot convertible between gases.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eLogs and operation (manual pp.12-17)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003ePlace the DX18 logs exactly per Figure 13; a paper-burning smell fades within hours.\u003c\/li\u003e\n\u003cli\u003eWait five minutes before relighting a pilot that went out.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBlower and maintenance (manual pp.8, 19-20, 24)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUse only the MA CVF714 blower; grounded three-prong plug.\u003c\/li\u003e\n\u003cli\u003eClean burner and pilot before each season; inspect yearly.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall to local codes or, where none apply, the \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e (manual pp.3-5, 11).\u003c\/li\u003e\n\u003cli\u003eAlso cited: the \u003ca href=\"https:\/\/www.iccsafe.org\/\"\u003eInternational Fuel Gas Code (International Code Council)\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eInstall and operate this appliance exactly as the manufacturer's instructions and local codes require. Improper installation, adjustment or maintenance can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide and benzene, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.p65warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e","brand":"Buck Stove","offers":[{"title":"Natural Gas \/ Black","offer_id":50681050824866,"sku":"NV S-TOWNSEND BLK-NG","price":1899.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ Vintage Copper","offer_id":50681050857634,"sku":"NV S-TOWNSEND VC-NG","price":1899.0,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Black","offer_id":50681050890402,"sku":"NV S-TOWNSEND BLK-LP","price":1899.0,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Vintage Copper","offer_id":50681050923170,"sku":"NV S-TOWNSEND VC-LP","price":1899.0,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Gray","offer_id":50714532020386,"sku":"NV S-TOWNSEND GY-LP","price":1899.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ Gray","offer_id":50714532053154,"sku":"NV S-TOWNSEND GY-NG","price":1899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/NV_S-TOWNSEND_BLK_White_Background.jpg?v=1795132689"},{"product_id":"breckwell-sw500-wood-stove-sw500","title":"Breckwell Wood Stove SW500","description":"\u003cul\u003e\n\u003cli\u003eHeats up to 750 sq. ft.; up to 26,000 BTU\u003c\/li\u003e\n\u003cli\u003eAccepts logs up to 11 in.\u003c\/li\u003e\n\u003cli\u003e6 in. flue; 1.7 g\/hr EPA emissions\u003c\/li\u003e\n\u003cli\u003eMobile home \/ transportable building approved (US and Canada)\u003c\/li\u003e\n\u003cli\u003eDimensions: 33.5\" H x 16.4\" W x 13\" D\u003c\/li\u003e\n\u003cli\u003eOptional B36T blower kit and 4FAK outside air kit sold separately\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/2129\/3073\/files\/853952---SW500_EN_FR.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOwner's manual\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Breckwell","offers":[{"title":"Default Title","offer_id":50714593788066,"sku":"SW500","price":1399.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/SW500front.jpg?v=1792875404"}],"url":"https:\/\/unitedfireplaces.com\/collections\/best-sellers.oembed","provider":"United Fireplaces","version":"1.0","type":"link"}